Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹4.8 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹5.4 Cr+₹59.2 L (12.3%)Rejected-Finance | ₹5.4 Cr+₹59.2 L (12.3%) | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹5.5 Cr+₹69.6 L (14.5%)Rejected-Finance | ₹5.5 Cr+₹69.6 L (14.5%) | L3 | Rejected-Finance Being other than lowest bidder |
| 4 | L4₹5.6 Cr+₹77.4 L (16.1%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹5.6 Cr+₹77.4 L (16.1%) | L4 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
25 May 2023, 6:00 pmClosed
CE HQ CE BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
CONSTRUCTION OF OFFICE ACCOMODATION FOR PAO ORs JAT REGIMENTAL CENTRE AT BAREILLY
2023_MES_586277_1
NIT NO CEBZ/BLY/T-33 of 2022-23
Open Tender
Civil Works
Lump-sum
365 days
BAREILLY
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Yes
Bareilly
₹5.9 L
Yes
22 Jun 2023
18 Mar 2023
1 Jun 2023
18 Mar 2023
25 May 2023
9 May 2023
Amount
Total amount of Sch 'A' Part I (Building Work) (For details see Sch 'A' Part-I A in PDF folder)
Total amount of Sch 'A' Part IIA (Internal Water Supply) (For details see Sch 'A' Part-II A in PDF folder)
SCHEDULE 'A' PART IIB (INTERNAL WATER SUPPLY)
S&F Bib tab, cast copper alloy, Fancy type, chromium plated with cruth or butterfly handle screw down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket, having maximum flow rate of water 6 LPM @ 45 PSI or 3.1 Bar pressure, complete all as specified and directed.
S&F 15mm bore pillar tap, cast copper alloy, with capstain head, chromium plated,screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, fancy type, screwed for iron pipe, having maximum flow rate of water 6 LPM @ 45 PSI or 3.1 Bar pressure, complete all as specified and directed.
Total amount of Sch 'A' Part III-A (INTERNAL ELECTRIFICATION) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
M&L for point wiring (concealed) complete using 1.5 Sqmm cross sectional area, single core FRLS PVC insulated unsheathed copper conductor, stranded cable upto and incl working voltage 1100 volts grade, PVC conduit not less than 20mm dia 'medium grade' ISI marked with fittings such as bend, tee, junction boxes elbows etc including pressed steel terminal sunken boxes of 1.2 mm thickness with 3mm thick plastic laminated sheet ISI marked top cover fixed with brass screws, cup washers and unsheathed copper conductor cable earth continuity wire connetctd to DBs/sunken boxes/fittings of size 1.5 Sqmm cross sectional area conductor and all other metal parts with earth dolly, complete all as specified and directed for the following:-
(a) One light point point controlled by one-one way switch 5/6 Amp.
(b) One Ceiling fan point controlled by one-one way switch 5/6 Amp through regulator
(c) One Exhaust fan point controlled by one-one way switch
(d) One three pin 5 Amp socket on independent board
(e) One bell/buzzer point one independent board controlled by one way switch 5/6 Amps.
All as per item No 8 above but one 3 pin socket outlet 15 Amp independent, with copper conductor cable 2.5 Sq mm size, with earth continuity cable copper coductor of size 2.5 Sq mm complete all as specified and directed.
S&F sheet metal enclosure with socket plug top and MCBs Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 240 V and 20 Amps complete all as specified and directed.
S&F new sheet metal enclosure DB TPN, 415 volt with 200 amps rated copper bus bar for double door 8 way IP-43 DBs IK-09 suitable for one MCCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB TPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-43 DBs IK-09 suitable for one MCB TPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB SPN, 240 volt with 200 amps rated copper bus bar for double door 12 way IP-43 DBs IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB SPN, 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43 DBs IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB SPN, 240 volt with 100 amps rated copper bus bar for double door 4 way IP-43 DBs IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S&F MCB Single Pole 6 to 32 Amps, 240 volts, 'B' curve breaking capacity 10 KA, complete all as specified and directed.
S&F MCB Single Pole & Neutral 6 to 40 Amps, 240 volts, 'C' curve breaking capacity 10 KA, complete all as specified and directed.
S&F MCB Single Pole & Neutral 63 Amps, 240 volts, 'C' curve breaking capacity 16 KA, complete all as specified and directed.
S&F 63/100 Amp MCCB three pole & neutral with thermal over load as well as magnetic short circuit tripping device suitable for three phase 415 volts, breaking capacity 16 KA, complete all as specified and directed.
Supply and fixing LED light fitting 40 watt, 230 volts, surface/wall mounting with integrated electronic driver with transcluent frosted diffuser, bipin holders, connector block etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable wire of suitable size, complete all as specified and directed.
Supply and fixing LUMILINE 20 watt LED light fitting high lumen with efficiency of 100 lumens, 230 volts, surface/wall mounting with integrated electronic driver with transcluent frosted diffuser, bipin holders, connector block etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable wire of suitable size, complete all as specified and directed.
Supply and fixing LED light fitting 9/10 watt, 2 feet long, 230 volts, surface and wall mounting with integrated electronic driver, high transcluent frosted diffuser, bipin holders, connector block etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable wire of suitable size, complete all as specified and directed.
Supply and fixing LED lamp 10 watt suitable for 230 volts, complete all as specified and directed. (Note:-Lamp holder shall be measured under Sch 'A' Part-IIIA)
Supply and fixing ENDURA NEO DL Porch light fitting 15 watt surface mounted LED downlighter with white powder coated aluminium housing with integrated electronic driver round shape including lamp complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor 1.5 sqmm cable wire, complete all as specified and directed.
Supply and fixing LED linear mirror light aeshthetically designed provided with high out put PMMA diffuser for glare free light 9/10 watt 300 mm, complete with all accessories and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
Supply & fixing energy efficeint environmental freindly long life LED street light fitting 45 Watt with high lumen output ready to use high voltage protection upto 440 volts with pressure die cast aluminium housing, heat resistant toughened glass, IP-65 protection and impact resistance of IK07 with 10 KV buit in surge protection device, better optics distribution with integrated electronic driver including connection up with three core copper conduct0r 1.5 sqmm wire from ceiling rose to connector of street light including wall/pole mounting GI pipe 'light grade' bracket of size 40 mm bore, 1.20 mtr long bent to shape including GI clamp of FI 50x4 mm with nut, bolt & washer, complete all as specified and directed.
S&F exhaust fan energy saving 3 star rated, single phase 240 volts, 300 mm sweep plastic body with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make- Havells, Model:Ventil Air DS / Crompton Greaves Model: Dritair 3 blade / Oreint Model: 300mm Air flow)
S&F ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230V, 1200 mm sweep, min air delivery 210 CFM with service valve 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make:-Crompton/Havells/Bajaj/Usha
S&F ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230V, 1500 mm sweep, min air delivery 210 CFM with service valve 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make:-Crompton/Havells/Bajaj/Usha
M&L for sub main wiring with two run single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 2.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings with chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 2.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 2.5 Sqmm cable and one run of 2.5 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
M&L for sub main wiring with two run single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 4 Sqmm as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 4 Sqmm cable and one run of 4 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
M&L for sub main wiring with two run single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 6.0 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 6 Sqmm as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 6 Sqmm cable and one run of 6 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
S&F blanking plate complete all as specifed and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth wire 4 mm dia (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 20mm dia and GI pipe 15 mm bore, medium grade for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 50 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : The unit rate includes for 20mm light grade protecton pipe and GI earth wire 4 mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode complete all as specified and directed.
S&F three phase change over switch ON LOAD type in enclosure sheet of capacity 100 KVA outdoor type with IP-66 protection complete all as specifed and directed.
Total amount of Sch 'A' Part IV (Site clearance and Earth work) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part V A (Road, Path, Culvert & Hard-stinding) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' Part V B (Road, Path, Culvert & Hard-standing)
M&L for Providing precast cement concrete type B1 1:2:4 20mm graded stone aggregate in kerb stone of size 300 x 150 x 300 (LXWXD), window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham?fers, weatherings, throat- ing etc. and se in cement mortar 1:6 complete with joints to match complete all as specified and directed.
M&L for laying 20mm graded stone aggregate as in base, 75mm compacted thickness with hand hold compactor machine, complete all as specified and directed.
M&L for laying 12.5mm graded stone aggregate, 75mm compacted thickness with hand hold compactor machine, complete all as specified and directed.
M&L for providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks glossy finish, 60mm thickness having compressive strength 40 MPa and of colour as approved by the GE, the top layer of paver blocks shall not be less than 6 to 8mm thick and should have Anti skid groove finish (vermicular finish), Joints shall be filled with sand complete all as specified & directed. Note:- The sand shall be free from clay and alkaline particles and conform to relevant IS. The edges of the paver block shall be neatly trimmed to fit within kerbs along the peri-pheri of the paved area. The unit rates quoted shall be inclusive of laying of paver block of different colour for making the Anchor pattern of size 4x6m and other pattern as directed by the GE/Engineer-in-Charge.
M&L Non woven Geotextile nominal weight 210GMS - polypropylene, Colour - GREY, Roll Size - 1M (WIDTH), complete all as specified and directed.
Total amount of Sch 'A' Part VI 'A' (Sewage Disposal) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VI-B (Sewage Disposal)
M&L for 150mm bore, HDPE DWC drain pipes (grade SN-8) conforming to IS:16098, laid in trenches and jointed with necessary fitings complete all as specified and directed.
M&L for construction of Septic Tank for 150 users excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole covers having 6mm plate embeded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as shown in drawings & specified. (Refer TD-217)
M&L for construction of Soakage Well of size 3.60 mtr dia and 4.50 mtr effective depth, excavation in any type soil, foundation in PCC 1:3:6, brick work in walls of Honey combed and solid using sub class 'B' bricks in cement mortar 1:4, including RCC cover slab in M-25 and filling with brick bats, complete all as shown in drawing & specified. (Refer TD-309)
Total amount of Sch 'A' Part VII (Area Drainage) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part VIII A (Compound Wall & Gate) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VIII-B (Compound Wall & Gate)
M&L steel gate including necessary excavation and earth work in soft/loose soil, RCC pillar, PCC coping bed block/ bed plate, wheel track, rendering in cement mortar & cement base paint on plastered surface and synthetic enamel paint on steel surface of gate complete all as specified and directed. (Reference TD No. BZ/Bly/203 Sheet No. 17 R/21)
Total amount of Sch 'A' Part IX A (External Water Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART IX-B (External Water Supply)
Cutting to existing CI/DI pipe line in position 100 mm bore for insertion of and including tee 100x100x80mm, branch, collar including jointing material etc. complete all as specified and directed.
Supply, Install and testing sluice valve 100 mm dia cast iron double flanged with drilled stainless steel spindle and CI wheel head IS-14846 sluice valve class PN-1.6 with and including drilled flanges fibre sheet packing mild steel nuts, bolts & washers, complete all as specified and directed.
Supply, Install and testing sluice valve 80 mm dia cast iron double flanged with drilled stainless steel spindle and CI wheel head IS-14846 sluice valve class PN-1 with and including drilled flanges fibre sheet packing mild steel nuts, bolts & washers, complete all as specified and directed.
M&L for construction of brick masonry valve pit (900 x 900 x 900) mm (outer dimension) with sub class 'B' bricks old size built in CM 1:4, PCC 1:2:4 type B-1 as in foundation concrete, bed/ floors, coping and 15 mm thick rendering in CM 1:4 on internal surface and exposed external surfaces plastered upto 15 cm below GL mixed with water proofing compound @ 2% by weight of cement including 40X40X6 mm angle iron frame & 3.15 mm thick MS sheet cover with locking arrangements and one 50 mm size 4 lever mild steel lock with key in duplicate including necessary earthwork in any type soil, painting steel surface with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
Total amount of Sch 'A' Part X A (External Electric Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART X-B (External Electric Supply)
Supply, installation, Testing and Commissioning of 11 kV, 630 A, 21 KA, for 3 Sec, SF6 insulated Ring Main Unit (RMU) consist of motorized 3 load break switch and VCB of capacity 630 Amps repalceable bushings complete in all respects as per specifications ( CCCV) :STANDARD: IEC 62 271-200 C RMU TYPE: 11kV,630A,21KA/3SEC, SafeLink CB ,CVC OUTDOOR MANUAL RMU RATED VOLTAGE: 11 KV RATED BUSBAR CURRENT :630A RATED FREQUENCY:50Hz POWER FREQUENCY WITHSTAND VOLTAGE / BIL:38KV / 95KVp D RATED SHORT CIRCUIT CURRENT:21KA D (Contd....)
RATED SHORT CIRCUIT CURRENT DURATION: 3s DEGREE OF PROTECTION-TANK: IP67 DEGREE OF PROTECTION-SWITCHGEAR : IP54 BUS BAR MATERIAL: CU AMBIENT TEMPERATURE: -25 - 40 Degree Celcius RMU FRONT COVER PAINT SHADE: RAL 7035 E RMU ENCLOSURE PAINT SHADE:DA GREY 632 OF IS5 ALTITUDE: <1500m BUSBAR INSULATING GAS:SF6 NOMINAL OPERATING GAS PRESSURE ;1.2 BAR @20 Deg C GAS LEAKAGE/ANNUM: 0.1% (Note:- Foundation for the VCB constructed as per manufacturer's recommendation and cost will be included in quoted rate)
Supply, instalation , testing and commissioning transformer of capacity 100 KVA copper wound, step down outdoor type HT 11 KV 3 phase, LT 433 volts,3 phase 4 wire, double wound oil immersed naturally cooled with external cooling tubes /radiator, core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dy-II (Vector Group) with neutral brought on secondary side (LV) and , with and having tapping (+)/(-)2.5%, (+)/(-) 5% and (+)/(-) 7.5% to be changed by means of hand operated off load tap changing gear the maximum temoerature rise should not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temperature of 40 degree of 40 degree centigrade and including with construction of open platform with mild steel rails resting for transformer as per recommendation of OEM with chain link fencing and steel gate etc. transformer conforming to IS-1180 (Part-I) 2014 including intial oil filling to appropriate level with desired dielectric strength and connected with the electric system including jointing materials, complete with standard fittings and accessories as under :- (a) Cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side . (b) Arrangement for connecting busbar trunking with neutral brought out as earthing terminal . (c) Off load changer +/- 7.5% @ 2.5% (d) Bi-directional roller. (e) Oil conservator with filter type drain valve and oil level gauge (Contd....)
(f) earthing terminals 02 Nos of the body of transformer . (g) Double diaphragm explosion vent. (h) Radiator with top & bottom shut off valve . (j) first filling of oil including make up fill. (k) Silica gel breather with oil seal . (l) Rating and diagram plate . (m) Air release plug. (n) Winding temprature indicator.(WTI) (o) Oil temperture indicator. (p) Magnetic oil level gauge. (q) Marshalling Box
Supply and fix AC three phase prepaid electric smart energy meter of accuracy class 1.0, 240 volts, 50 Hz, with backlit LCD display of rating 0-630 Amps (suitable for measurement of KWH only) complete all as specified and directed.
Supply, install, testing and commissioning LT panel, outdoor type cubical panel board, made out of 3.15 mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators comprising of the following:- INCOMER i) MCCB 4 pole 200A, incomer, 415V, 50Hz, 25 KA - 01 No. OUTGOING i) MCCB 4 Pole 100 A, 415V, 16KA - 01 No. ii) MCCB 4P 63 Amp , 16 kA - 2 Nos. ii) MCB SPN 20A, 10 kA - 2 No. BUSBAR 200 A rated aluminium bus bar with colour coded heat shrinkable sleeve (Contd....)
Supply fabrication installation testing & commissioning (CPRI approved) 440V AC APFC, Panel compartmentalized & modular type outdoor type factory made out of 3.15 mm CRCA sheet of appropriate size, front operate able single door front & back operate only, dust & vermin proof, cable entry through 2cm CRCA gland plates –top & bottom only. powder coated after & tank pre-treatment process segments grey space on body/doors & orange shade on mounting gland plates + Incomer Doors. 3 phase HS sleeved coat coded aluminium main busbar of 700A (70 x 10mm for 3 phase) with transparent polycarbonate covers & on SMB/DMC insulators. 25 x 6mm aluminum earth busbar running across the whole length of the LT panel with studs at both the side –ends, fifting arrangement /hooks at the top, wiring with appropriate size of copper Industrial cable, black paint on base frame made out of 40x40x5 mm angle section. cables glades brass chromium plated of different sizes suitable for incoming & outgoing MCCB's are fitted with following specified items. (Contd....)
(A) Rating -60 KVAR With 2 Steps (2X30) APFC Panel Incoming MCCB Microprocessor based release with overload & short –circuit protections Rating 160A FP 25 KA (lcs = 100 Icu Contacts 7 Rotary Handle mechanics -01 Nos (Schneider /ABB/C&S Make)
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 40mm dia and GI pipe light grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : (i) The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode complete all as specified and directed.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and with lumen efficeincy 120 watt including bracket made out of GI pipe light grade 1.2 mtr length of suitable size bent to shape fixed with necessary calmps, nuts & bolts etc. complete all as specified and directed.
Supply, transporting, erecting and fixing steel tubular, swaged pole of over all 9 mtr long, type 410 SP -31 single swan neck complete with cast iron base plate, pole cap/finial taper plug, bolts, nuts washers, including painting with two coats of aluminium paint one coat over a red oxide primer and 03 Nos band/straps with flourescent red post office box-colour (300mm wide each) in alternative strips from plinth block and marking pole numbers with black synthetic paint writing in 2.5 cm height including bituminous painting on embeded portion of pole in concrete, complete all as specified and directed.
Supply, transporting, erecting and fixing steel tubular, swaged pole of over all 11 mtr long, type 410 SP-55 complete with cast iron base plate, pole cap/finial taper plug, bolts, nuts washers, including painting with two coats of aluminium paint one coat over a red oxide primer and 03 Nos band/straps with flourescent red post office box-colour (300mm wide each) in alternative strips from plinth block and marking pole numbers with black synthetic paint writing in 2.5 cm height including bituminous painting on embeded portion of pole in concrete, complete all as specified and directed.
Cutting into existing road of bitiminous macadam / concrete road to the required width / depth of LT cables for passing GI pipes/cables and making good to match with existing surfaces complete all as specified and directed.
SCHEDULE 'A' PART XI (COOLING APPLIANCES)
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum five star rating and EER 3.2.of capacity 2 TR incl stand for outdoor unit, floor/wall mounted, copper tubing and necessary drain pipe complete all as specified and directed.
Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed.
Supply, installation, commissioning of Water Cooler 5 star stainless steel, electric driven single phase having approx storage capacity 80 litre and nominal cooling capacity 40 litre per hour, complete all as specified and directed.
Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 120 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 1 KVA complete all as specified and directed.
SCHEDULE 'A' PART XII (FIRE FIGHTING SYSTEM)
Supply and Install Booster pumps for 440 V, 3 Phase, 50 Hz, 30 mtr head 450 LPM discharge capacity confirming to IS- 12469 :1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and directed.
Supply, laying & jointing Mild Steel ERW flanged pipe 100 mm bore heavy duty conforming to IS:1239 including all fittings i.e. reducer, elbows, tees, flanges etc. duly painted with synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply, Install and testing sluice valve cast iron body with double flanged and drilled end non rising type, HT bronze spindle with nut and wheel, Class PN-1.6 suitable for 100 mm bore conforming to IS-14846 ISI marked including all joints with rubber or fibre sheet packing and mild steel nuts, bolts & washers complete all as specified and directed.
M&L for Hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet set painted fire red out side and brilliant white inside yard complete all as specified and directed.
M&L for fire alarm control panel complying with BSEN 54 single loop panel Capacity from 99 detectors & 99 modules upto of 200 detector and modules complete all as specified and directed.
M&L for fire alarm sounders/sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 measured at 1.5 Mtr with sound output variation of 5 DB 1000 mtr range complete all as specified and directed.
S & F 63 mm dia, 15 mtr long rubberised fabric reinforced rubber lined hose including gun metal male & female instataneous coupling, hose confirming to IS : 636 type II and coupling confirming to IS 903-1975 complete all as specified and directed.
Supply, fixing, testing and commissioning of fire fighting hose reel conforming to IS:1969-2 (swinging type) with 30 mtr long and 20mm internal dia ruber lined hose reel tubing, 32 mm dia hand liver operated ball valve, connecting directly from the riser through 32 mm dia GI pipe with socket , 5 mm dia shut off nozzle of sufficient length at one end of this hose and leaded tin, bronze rings and adopter to get into the instantaneous female coupling with suitable drawn brackets, hub etc. complete all as specified and directed. (The hose reel shall conform to IS 884-1969-2)
Supply and fix Gun metal one way/single headed fire hydrant landing valves of size 63 mm dia, complete with instantaneous coupling, all as specified and directed.
Supply and fix 63 mm dia gun metal branch pipe with 15 mm nozzle conforming to IS 903 complete all as specified and directed.
Supply, laying and testing ISI Marked 2 core x 1.5 mm2, Multistrand Copper, FRLS Armoured cable (red in Colour), laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling complete all as specified and directed.
Supply, installing, testing and commissioning of addressable dual action manual pull stations including providing MS box of suitable size for concealing the manual call point (MCP) in the wall and with mounting accessories, complete all as specified and directed.
S&F fire extinguisher dry chemical powder (ABC) type 5 Kg complete all as specified and directed.
S&F fire extinguisher CO2 type 4.5 Kg complete all as specified and directed.
S&F fire extinguisher mechanical foam type 25 Kg alongwith trolly of suitable size for smooth operation complete all as specified and directed.
SCHEDULE 'A' PART XIII (MISC ITEMS)
M&L for Rigid non-metallic PVC conduit of size 25 mm dia inclusive of boxes (junction/ terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for passing of telephone of / LAN wiring, complete all as specified & directed.
Supply & fixing Venetian blinds of coded free-hanging design, with horizontal metal slats adjustable to various angles and to different heights, used in windows covering when it is desired to simultaneously control the degrees of light, privacy, view, heat and ventilation, blinds over 120 inch (3.048 Mtr) in width or length, or requiring a maximum pull force over 45 lbf (200 N) to raise completely (as determined by ANSI/WCMA A101.1-2008 pull force testing), require special mechanisms, complete all as specified & directed.
Supplying & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles fully perforated of size 595x595mm and 10mm thickness of approved texture, design and pattern having mosture content less than 2% humidity resistance of 99%, NRC 0.50 to 0.75 as per IS:8225-1987, non combustible as per BS 476 (Part-4)-1970 and light relectance of 85% (minimum) to be laid in true horizontal level, suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (Galvanizing @ 120 gram per Sqm on both sides) comprising of main T-runners of size 24x38 mm of length 3000 mm, cross-T of size 24x28 mm of length 1200 mm and secondary intermediate cross-T of size 24x28 mm of length 600 mm to form grid module of size 600x600 mm, suspended from ceiling using galvanized mild steel items (Galvanizing @ 80 gram per Sqm) i.e 50mm long, 8 mm outer diameter M-6 dash fastners , 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm galvanized iron perimeter wall angle of size 24x24 mm and thickness 0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs @ 450 mm C/C and 40mm long dry wall wood screws, complete all as specified & directed.
Supplying & fixing false ceiling Knauf Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400mm made of mosture resistant fibre board substrate with a laminated as per approved shade (Portland, Maple, Sea Beech, Siam Wood & Mystique Walnut, interior white) and a malamine balancing layer on the reverse side, the board have a special perforation pattern where the reverse surface has a "Heimholtz" fluted perforation with consecutive 3mm wide grooves followed by 6/13/21 of visible pane, the edges of panel shall be "tongue-and-grooved" to fix special clips for installation and seamless visual, the back of perforated panel shall have sound absorbing non-woven accoustical fleece hot pressed to achieve NRC upto 0.6 (Average value of absorption Co-efficient reading taken at 250 Hz, 1000 Hz and 2000 Hz) as per ASTM C-423 and humidity resistance (RH) of 70% with camber limit less than 1 mm/1000mm and bow less than 1mm/300mm, the panels shall be mounted on special aluminium splines (keel) using inside clips provided by manufacturer's and approved by the Architect, complete all as specified & directed.
Properties of Tiles
Base Material: Moisture Resistant Medium Density Fibre Board
Panel Dimensions: 2400mmx192mmx15mm (Thickness)
Panel Weight: 8.5 Kg Per Sqm
Perforation Details: "Helmholtz" flued perforation reverse side with consecutive of 3mm wide groove followed by 5/12/21 mm of visible pane.
Panel Finish: laminate (Portland, Maple, Sea Beech, Siam Wood & Mystique Walnut, interior white) finish
Noise Reduction 0.6 Co-efficient: ASTM C-423 (Average Value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz)
Humidity Resistance: RH 70%
Dimensional Tolerances: (+) or (-) 5 mm
The panel shall be mounted by tongue and groove mechanism using inside clip on Knauf aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L)x24(H)x15.5(W). The keel shall also be used for transition of the butt end of adjacent panel at every 7.2 mtr.
Installation System Details (Aluminium Keel / Transition Profile)
Base Material: Extruded Aluminium Grade 6063-T5
Construction Method: Aluminium Extrusion
Dimensions: 3000(L)x24(H)x15.5(W) mm
Accessoies: Inside Clip
Note : Tenderers may note that amount of credit Rs 00.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
JALAKASH
VEE SONS BUILDERS PVT LTD
M/s Arihant Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .