Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹43.1 L+₹3.1 L (7.67%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹43.8 L+₹3.8 L (9.57%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹45.3 L+₹5.3 L (13.2%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹46.9 L+₹6.9 L (17.3%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | SARJIT SINGH AND CO. L1 | KRISHNA CONSTRUCTION COMPANY L3 | M/s Sati Jasnath Enterprises L7 | D DEV COMPANY L5 | M/S SOLANKI GENERAL SUPPLIERS L4 | JANGID BUILDERS L6 | MAHINDRA WORLD L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for cleaning and Racking out of old expansion joint of any length, 20 mm to 30 mm wide and 45 mm to 55 mm deep of existing sealant compound, back up rod and filler board of the existing joints by special tools like chisel, hammer, L type hook, racker/cutting blades/machines, widening of joints by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant thereafter filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified, over it filled with closed cell medium density, cross linked polyethylene foam backup rod of 30 mm to 40mm dia for complete length of the joint. Finally filled with pitch free grey polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor MAF of +/- 30% minimum depth of sealent above de bonding strip shall be 10-15mm and applying masking tap on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed. | 700 | Ten RM | 1,341 ₹9,38,700 | 1,482 ₹10,37,400 | 1,000 ₹7,00,000 Lowest | 1,800 ₹12,60,000 | 1,247 ₹8,72,900 | 1,600 ₹11,20,000 | 1,295 ₹9,06,500 |
| 2.00 | M&L for cleaning and Racking out of old dummy joints of any length, 8 to 10 mm wide and 26 to 31 mm deep of existing sealant compound and back up rod of the existing joints by special tools like chisel, hammer, L type hook, cutting blades/machines, widening of joints by using joint cutting blades of appropriate size straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Thereafter filled with closed cell, medium density, cross linked polyethylene foam backup rod of 10 to 12 mm dia fo complete length of the joint, over it to be filled with pitch free gray polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-1418752003 with minimum movement accommodation factor (MAF) of+/- 30% minimum depth of sealent above de bonding strip shall be 10-15mm and applying masking tap on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed. | 2,000 | Ten RM | 810 ₹16,20,000 | 862 ₹17,24,000 | 1,150 ₹23,00,000 | 700 ₹14,00,000 Lowest | 947 ₹18,94,000 | 950 ₹19,00,000 | 900 ₹18,00,000 |
| 3.00 | M&L for cleaning and Racking out of old construction joints of any length, 12 to 18 mm wide and 31 to 45 mm deep of existing sealant compound and back up rod of the existing joints by special tools like chisel, hammer, L type hook, cutting blades/machines, widening of joints by using joint cutting blades of appropriate size straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris . Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before pouring the sealant Thereafter filled with closed cell medium density, cross linked polyethylene foam backup rod of 15 to 20 mm dia for complete length of the joint, over it to be filled with itch free gray polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+!- 30% minimum depth of sealent above de-bonding strip shall be 10- 15mm) and applying masking tap on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed. | 1,276 | Ten RM | 900 ₹11,48,400 Lowest | 982 ₹12,53,032 | 1,050 ₹13,39,800 | 1,200 ₹15,31,200 | 1,057 ₹13,48,732 | 1,020 ₹13,01,520 | 950 ₹12,12,200 |
| 4.00 | M&L for Cutting existing loose patches/spalled edges, widening of existing cracks of concrete pavement in true geometrical shapes to average depth of 20 mm to 25 mm using diamond cutters operated with gen sets, cleaning the surface dry and free from dust/dirt with air compressor in order to achieve proper bond between elastomeric concrete and cement concrete surface and applying polyurethane based elastomeric concrete over a coat of approved primer as per manufacturer's instructions including supply and fixing masking tape on pavement surface to prevent accidental spillage of elastomeric concrete and removing the masking tape and cleaning the area of application after the application is over complete all as specified and directed.
Note :- No claim shall be made by contractor for above Sr Item No 1 to 4 for Site availability as per User's /site requirement and stoppage of work due to any aircraft coming and stoppage of work in a day. The rates shall be deemed to be included in the respective items. work to be execute at Runway 05 & 23 End, North loop, North dispersal, 05 & 23 ORP. | 25 | Sqm | 11,700 ₹2,92,500 Lowest | 14,722 ₹3,68,050 | 15,500 ₹3,87,500 | 20,000 ₹5,00,000 | 16,547 ₹4,13,675 | 15,399.23 ₹3,84,980.75 | 15,500 ₹3,87,500 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
9 Jun 2025, 6:00 pmClosed
CWE (AF) Jodhpur
HQ CWE AF JODHPUR Opp Mosam Vibhag Airforce Chauraha , Ratanada Jodhpur (Raj)-342011
REPAIR TO JOINT FILLING INCLUDING REPAIR TO CONCRETE PAVEMENTS AND CRACKS WITH ELASTOMERIC CONCRETE AT RUNWAY, LOOP, ORPS AND CONNECTED DISPERSAL IN TECH AREA AT AFS PHALODI
2025_MES_707130_1
89060/E8
Open Tender
Civil Works - Roads
Item Rate
180 days
GE (AF) Phalodi
as per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Phalodi
₹1 L
Yes
22 Aug 2025
8 May 2025
11 Jun 2025
8 May 2025
9 Jun 2025
26 May 2025
Amount
M&L for cleaning and Racking out of old expansion joint of any length, 20 mm to 30 mm wide and 45 mm to 55 mm deep of existing sealant compound, back up rod and filler board of the existing joints by special tools like chisel, hammer, L type hook, racker/cutting blades/machines, widening of joints by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant thereafter filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified, over it filled with closed cell medium density, cross linked polyethylene foam backup rod of 30 mm to 40mm dia for complete length of the joint. Finally filled with pitch free grey polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor MAF of +/- 30% minimum depth of sealent above de bonding strip shall be 10-15mm and applying masking tap on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed.
M&L for cleaning and Racking out of old dummy joints of any length, 8 to 10 mm wide and 26 to 31 mm deep of existing sealant compound and back up rod of the existing joints by special tools like chisel, hammer, L type hook, cutting blades/machines, widening of joints by using joint cutting blades of appropriate size straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Thereafter filled with closed cell, medium density, cross linked polyethylene foam backup rod of 10 to 12 mm dia fo complete length of the joint, over it to be filled with pitch free gray polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-1418752003 with minimum movement accommodation factor (MAF) of+/- 30% minimum depth of sealent above de bonding strip shall be 10-15mm and applying masking tap on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed.
M&L for cleaning and Racking out of old construction joints of any length, 12 to 18 mm wide and 31 to 45 mm deep of existing sealant compound and back up rod of the existing joints by special tools like chisel, hammer, L type hook, cutting blades/machines, widening of joints by using joint cutting blades of appropriate size straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris . Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before pouring the sealant Thereafter filled with closed cell medium density, cross linked polyethylene foam backup rod of 15 to 20 mm dia for complete length of the joint, over it to be filled with itch free gray polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+!- 30% minimum depth of sealent above de-bonding strip shall be 10- 15mm) and applying masking tap on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed.
M&L for Cutting existing loose patches/spalled edges, widening of existing cracks of concrete pavement in true geometrical shapes to average depth of 20 mm to 25 mm using diamond cutters operated with gen sets, cleaning the surface dry and free from dust/dirt with air compressor in order to achieve proper bond between elastomeric concrete and cement concrete surface and applying polyurethane based elastomeric concrete over a coat of approved primer as per manufacturer's instructions including supply and fixing masking tape on pavement surface to prevent accidental spillage of elastomeric concrete and removing the masking tape and cleaning the area of application after the application is over complete all as specified and directed. Note :- No claim shall be made by contractor for above Sr Item No 1 to 4 for Site availability as per User's /site requirement and stoppage of work due to any aircraft coming and stoppage of work in a day. The rates shall be deemed to be included in the respective items. work to be execute at Runway 05 & 23 End, North loop, North dispersal, 05 & 23 ORP.
MAHINDRA WORLD (BID ID -3311009)
KRISHNA CONSTRUCTION COMPANY (BID ID -3306826)
M/S SOLANKI GENERAL SUPPLIERS (BID ID -3316125)
D DEV COMPANY (BID ID -3310872)
JANGID BUILDERS (BID ID -3311515)
M/s Sati Jasnath Enterprises (BID ID -3310442)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .