Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC KRISHNAKRIPA KOTTARAKARA | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | Rejected-Technical Only B Class License |
Tender Value
₹25.8 L
EMD Value
₹50,000
Closing Date
5 Jul 2024, 3:00 pmClosed
Executive Engineer
PWD Electrical Division Third Floor Civil Station Alappuzha PIN-688001
DEPOSIT-Thaluk Head Quarters Hospital, Kadakkal-Providing HT Connection- General Electrical Work
2024_PWD_661539_3
PWD/BLDG/TR/104453/2021_6
Open Tender
Electrical Works
Item Rate
150 days
THQH Kadakkal-Kollam Dist
Please refer Tender documents.
13 documents required · 13 mandatory
₹2,760
₹50,000
23 Sept 2024
25 Jun 2024
8 Jul 2024
25 Jun 2024
5 Jul 2024
25 Jun 2024
Amount
Electrification
OD19666/2022-2023:Supply, conveyance, installation, testing and commissioning of 315K.V.A Indoor unitized substation comprising of H.T. panel trunked with cast resin Transformer with load break switch/ Air break switch and manually operated on H.T. side, with bottom entry cable box, M.C.C.B with NCT and relay on L.T. side as per technical details furnished below. 1. H.T. Portion consists of .1 No 11K.V, 630A, 350M.V.A Air break/Load break switch suitable for 3 phase,3wire,50 Hz system with suitable H.R.C. fuses of appropriate rating with earth inter lock with main switch and mechanical ON/OFF indication, shunt trip coil for the remote operation of the load break switch, 2. TOD Metering Facilities consists of 3Nos ---/5A (or suggested by K.S.E.B) 15VA, 0.2 Class accuracy Cast resin C.Ts. 1No 3Phase 3Limb 11KV/110V, 10VA, 0.2 Class accuracy Cast resin P.Ts. with protective fuses. 1No TOD meter 1No TOD meter test terminal block, (TOD meter and CTs, PTs unit compartment shall be so fabricated. So as to enable the K.S.E.B authorities to seal it) and including arranging testing and installation of the same with K.S.E.B. Testing Division. 3. Transformer portion consists of 315 K.V.A, 11 K.V/433V, 50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish. Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap position of 2.5% x 4 .The transformer shall confirm to IEC 726 and IS 11171/1985 reaffirmed in IS2026/ 1991. 4. The LT portion consists of 1No 4Pole 630A 50KA isolation duty type MCCB with microprocessor based release with overload setting of 50 - 100% with inbuilt earth fault relay, suitable size NCT, MC12 relay, shunt trip coil in existing MCCB for additional earth fault protection and All inter connection from HT load break switch to transformer and to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contacts including, all internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall comply with IP standards for indoor use as per IS and shall be powder coated over after seven tank processing and phosphating. The USS shall be installed as per the directions of Engineer in charge at site.
OD24928/2022-2023:Supply and fixing Emergency Push Button with MS Box and giving connection etc as required.
OD34086/2022-2023:Supply installation testing and commissioning of TOD Meter, 3 Ph 4 Wire, 0.2S Class accuracy both for active and reractive power.
OD243840/2022-2023:Supply and providing SIntex or equivalent Thermoplastic Box of size not less than 400x300x190 with provision to fix Neutral CT etc complete with necesssary clamps(GS-JB-4030)
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD124183/2021-2022:Supply and Fixing of Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia
OD124184/2021-2022:Supply and Fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia
OD124115/2021-2022:Suply & fixing the following multi-function meters in the panel assembly. Three phase multifunction meters to read V, A and F, accuracy class 0.5
OD124360/2021-2022:Supply & fixing 2 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
OD124359/2021-2022:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
OD124122/2021-2022:Supply, conveyance, installation, testing and commissioning of the Panel temperature controlled fan 100x100mm size 24V DC /240V AC with thermostat and giving connection as required.
90.14.11.4:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 630A to 800A with CBCT.
OD124125/2021-2022:Supply and fixing the following legend plates in the panel assembly. Enameled Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
OD124126/2021-2022:Supply and Fixing of Auto - Manual, 40 x 25 mm with 15 m hole aluminium anodised legend plates
OD94511/2022-2023:Providing and fixing following 400/5 A, 5 VA, accuracy class .5, Resin Cast Metering CT in existing panel and giving connection complete
OD94512/2022-2023:Providing and fixing following 600/5 A, 15 VA, accuracy class 1, Resin Cast Metering CT in existing panel and giving connection complete
OD94453/2022-2023:Providing and fixing following 250/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT in existing panel and giving connection complete
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.13:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.16:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
OD28005/2022-2023:Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating upto 630 A (8 pcs) cat no. CM92004OOOO / Equivalent make
OD28000/2022-2023:Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating upto 250 A (8 pcs) Cat No 92007OOOO/Equivalent make
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
OD152189/2021-2022:Supplying and fixing 40-63A rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD124116/2021-2022:Supply & fixing the following accessories in positon and giving connection. 8 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
90.14.24.51:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.25 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.
90.14.24.36:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.47:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.
OD124402/2021-2022:Providing and fixing following capacitor duty contactor 3P 25 KVAR existing panel and giving connection complete
OD235157/2022-2023:Providing and fixing following capacitor duty contactor 11-15 KVAR existing panel and giving connection complete
OD124123/2021-2022:Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'OFF', (Contact - 1 NC) and giving connection etc as required.
OD124124/2021-2022:Supply and Fixing of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact - 1 NC) and giving connection etc as required.
90.14.11.9:MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to 630 A.
90.12.6.34:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm
9.4.24:Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2X 185 sq. mm
OD24178/2022-2023:Supply of PVC insulated and PVC sheathed XLPE armoured aluminium power cable, 11 KV grade of the following sizes , making good the damages , colour washing etc. as required.3 core 300 sq mm
8.4.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
90.12.6.35:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm
90.12.6.36:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 300 sq mm
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
OD27701/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 16.00 sq mm single run with required sockets.
OD27702/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10.00 sq mm single run with required sockets.
OD24917/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 6.00 sq mm single run with required sockets.
OD124189/2021-2022:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
OD124460/2021-2022:Supply and providing plate earthing with 1200x1200x12 mm GI/CI earth plate, 50mm GI watering pipe, GI funnel with weld mesh, 25 x5mm GI clamps, charcoal,salt etc., including providing brick work masonry enclosure at the top (450 x 450 x 450 mm inside) with Gully trap with covering box in CI (450x450x10mm)but excluding earth continuity conductor, test joint
OD42511/2022-2023:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 6 mm tinned copper strip
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
OD243838/2022-2023:Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in hard soil). 25 x 3mm copper strip tinned at the points of contacts
OD124501/2021-2022:Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.
OD124503/2021-2022:Steel work in MS Channels (in single section) cutting, hoisting and fixing in position including painting with 2 coats of enamel paint over a coat of zinc chromate primer.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD24268/2022-2023:STEEL REINFORCEMENT- Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level.
OD24387/2022-2023:Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
OD124493/2021-2022:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. as per IS 2546
OD218525/2023-2024:Supply and providing 2mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength and the mat should be permanently pasted with the help of suitable adhesive /resin etc. as required.
OD124502/2021-2022:Supply and providing 6 Kg. ABC Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD124498/2021-2022:Supply of Electrical safety hand Glows 2.9mm minimum thickness,withstanding 26 KV protection made by Natural Latex, off white colour ( Certification shall be attached) .
OD124500/2021-2022:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
OD34089/2022-2023:Charges towards the preparation of necessary plan, scheme and other related papers for submission.
OD34090/2022-2023:Charges towards the preparation of necessary plan, scheme and other related papers for additional sheet.
OD124499/2021-2022:Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required
OD34088/2022-2023:Amount to be deposited with K.S.E.L.B for scheme approval and energisation sanction.(Actual amount will be reimbursed on production of original documents)
POZITIVE POWER INDIA PVT LTD
Bidder Name
K K Associates
POZITIVE POWER INDIA PVT LTD
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1053670.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .