| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical DISTT BALOTRA | BALOTRA | RAJASTHAN | - | - | Rejected-Technical Not Qualified |
| Sl No | Description | Qty | Unit | Eskave Engineering and Hospitality Services Pvt.Ltd L3 | BINOY R L1 | BT INTEGRATED SOLUTIONS PVT LTD L2 |
|---|---|---|---|---|---|---|
| 1.00Civil Renovation Works | ||||||
| 1.01 | Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge | 240.32 | sqm | 325 ₹78,104 | 100 ₹24,032 | 143 ₹34,365.76 |
| 1.02 | Dismantling PVC/WPC wall panelling and its frame work including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge | 140 | sqm | 300 ₹42,000 | 100 ₹14,000 | 143 ₹20,020 |
| 1.03 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | 0.17 | cum | 28,765 ₹4,890.05 | 3,000 ₹510 | 10,495 ₹1,784.15 |
| 1.04 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 12.81 | cum | 2,800 ₹35,868 | 2,500 ₹32,025 | 6,997 ₹89,631.57 |
| 1.05 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 5.25 | sqm | 550 ₹2,887.5 | 100 ₹525 | 1,400 ₹7,350 |
| 1.06 | Taking out doors, windows and clerestory window shutters and glazing (Aluminium Work) including stacking within 50 metres lead: Of area beyond 3 sq. metres | 11 | each | 750 ₹8,250 | 350 ₹3,850 | 650 ₹7,150 |
| 1.07 | Dismantling elevated platform for minimum 100mm to 450 mm height, made of wood/steel/aluminium frame and panels all complete including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge. Note:-Only plan area of platform will be considered for making payment. | 9.99 | sqm | 785 ₹7,842.15 | 100 ₹999 | 700 ₹6,993 |
| 1.08 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). | 20.84 | cum | 13,500 ₹2,81,340 | 11,000 ₹2,29,240 | 10,777 ₹2,24,592.68 |
| 1.09 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand) | 6.04 | cum | 7,500 ₹45,300 | 12,000 ₹72,480 | 17,483 ₹1,05,597.32 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
16 Feb 2026, 3:00 pmClosed
Deputy Vice President (Projects)
Projects Division, HLL Lifecare Ltd, HLL Bhavan Poojappura
Civil and MEP works
2026_HLL_262969_1
HLL/CHO/PROJ/PFT/JNCMWC/CONF/R
Open Tender
Civil Works - Buildings
84 days
HLL Lifecare Ltd., Peroorkada
Please refer Tender documents.
10 documents required · 10 mandatory
₹5,900
HLL Lifecare Ltd
₹1 L
19 Feb 2026
14 Jan 2026
17 Feb 2026
14 Jan 2026
16 Feb 2026
14 Jan 2026
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Dismantling PVC/WPC wall panelling and its frame work including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Taking out doors, windows and clerestory window shutters and glazing (Aluminium Work) including stacking within 50 metres lead: Of area beyond 3 sq. metres
Dismantling elevated platform for minimum 100mm to 450 mm height, made of wood/steel/aluminium frame and panels all complete including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge. Note:-Only plan area of platform will be considered for making payment.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.One coat
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
Providing and laying Matt finish interior Vitrified tiles in floors and skirting with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1200x600 mm
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square
Extra for additional labour for circular works, such as in frames of fan light:Second class teak wood
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)
Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete.
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge.
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with:Second class teak wood
Varnishing with varnish of approved brand and manufacture :Two or more coats glue sizing with spar varnish or an under coat of flatting varnish
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal dia pipes
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer;s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing and fixing flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete includin frame work and providing decorative lamination on the exposed surface including coving and light provision and curving etc complete as per approved Architectural drawing etc complete:12 mm thick
Providing and fixing Carpet vinyl flooring of min 6mm thick with necessary fixing arrangement etc complete . Mat shall be of the required pattern and colour approved by the engineer in charge.
Providing and Installing acoustical treatment on the existing plastered vertical wall surface including frameworks using Aluminium section of sectional dimensions of 50mm x 25mm x 1.6mm thickness formed to a 600mm x 600mm grid, and placing/packing acoustical insulation in full (rockwool) having density of 48 g/cum and 50mm thick fully wrapped in black kora cloth, above which 4 mm thick perforated BWR ply board with a frame of 18 mm thick BWR ply is installed and finished with dual tone 12 mm thick acoustical PET panel boards pasted using approved/ required adhesive with approved colour combinations and approved architectural patterns and design. The PET panel should be lightweight, durable, impact-resistant, moisture/humidity resistant, insect/fungi resistant, non-irritating and it should have High Sound Absorption (NRC 0.8-0.9), Class A rated for fire resistance (ASTM E-84) and low VOCs. The rate shall be inclusive of installation on the framework arrangements, necessary scaffolding, staging at all levels, material and hire charges, conveyance and labour etc. complete
Providing and fixing of Fire Rated double door total size 1800x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification. Frame: Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant. Shutter: Double Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test. Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches. Door Hardware: Stainless steel Ball bearing Hinges 6 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar in each door shutter.
Providing and fixing in wall lining medium density fibre board IS: 14587: 1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete.18mm thick.
Providing and fixing decorative wall paneling work with Pre-laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, with necessary fixing arrangement for self-standing or backing or studding with screws etc. complete as per architectural design including provisions for strip lighting work etc. complete using 50mm thick board.
Zebra black out Blinds: Providing and Fixing designer Zebra blacout blinds for windows with approved colours as per Indian standards suitable for auditorium or seminar halls with following Specification Head Rail, Bottom Rail: Made of extruded aluminium powder-coated with high mechanical strength, UV-resistant, and anti- fogging polyester powders, it is expressly made for accessories to set inside IG units. Ladder tape and cords are provided with 100% polyester, excellent dimensional stability, and high mechanical & UV resistance. Modular and durable chain for vertical movement.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing, supplying, installing, testing and commissioning top-supported sliding folding acoustic partition system, consisting of 85 mm thick factory-manufactured acoustic panels with internal sound-absorbing infill to achieve minimum sound reduction rating Rw 35 dB up to 52 dB, supported on heavy-duty overhead aluminium track system fixed to RCC / steel beam, without any floor load bearing, complete with high-load capacity rollers (end / eccentric / centre type) designed to carry full panel weight, ensuring smooth, silent operation. The system shall include acoustic bulb seals with additional foam insert at vertical joints, retractable top and bottom seals where required, SAA finished aluminium profiles (M85), head track finished in RAL 9010 white, floor guide / SAA threshold only for alignment, 65 mm wide wall jambs finished in RAL 9016 white, suitable for panel heights up to 4000 mm and widths from 450 mm to 900 mm, arranged in single, double or bi-parting configuration, inclusive of all fixing accessories, suspension brackets, structural connections, stacking arrangement, alignment, testing, and making good, complete in all respects as per manufacturer’s recommendations, approved drawings and directions of Engineer-in-Charge.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge.
Providing and fixing bright finished brass handles with screws etc. complete:350 mm
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm
Furniture
Supply and installation of non-revolving Breathable Mesh Ergonomic Office Chair, Medium Back, comfortable seating space, Mesh Back with high back support with fixed supports made of 304 Stainless Steel/powder coated MS of approved colour or shade as per the instruction of the engineer in charge/Architecture in charge.
Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , 2 - Dimensional armrest providing natural resting for arms with automatic weight sensing mechanism. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery : Heavy duty rubber backed fabric in BLACK.
Providing curved stage table of required size (Minimum width 600 mm and seating height of 750 mm and total length of 7000 mm ) made up of 18 mm thick BWR ply wood finished with 1mm thick laminate of approved shade and colour on both sides with 3 Nos Flip box for power and data arrangement having min 3 Nos sockets and Ethernet port finished with channels handles, hinges, lock and all other fittings and arrangements all complete as per approved design of Engineer in charge/Architect. Only Front Elevation area will be measured for making payment.
Supply and fixing Lightweight and weather-resistant designer larger/taller pots made out of fiberglass Suitable for indoor and outdoor use including any of the artificial good quality Large indoor Plant include Palm/Alocasia/Rubber Plant/Fiddle Leaf Fig/Aralia/China Doll. The minimum height of pot should be 450 mm and maximum height should be 750 mm. Plat and pot should be as approved by Architecture in charge. In pots optional add-ons should be available for placing original plants.
Backlit Acrilic Board with projected letters: Supply, installation, testing and commissioning of weatherproof backlit acrilic board with projected letters made upof 20mm thick acrilic board and having box depth of min 100mm in approved size and design with reqired LED strips for high glow light. The board shall be fabricated and fixed over suitable welded and painted 25X25X3mm MS angle frame in suitable location and in proper line and level with all necessary fastners, supports etc. Electrical works likes electrical wirings, connections, fittings, externaly fixed weather proof 2/3 pin plug points and sockets including boxes etc. to be complete properly. All fabrication and fixing should be done as per approved design and instructions of Engineer in Charge. (Note: Only front elevation will be measured.)
Aluminium partition work
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness
Wiring
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
Supply, laying, testing, and commissioning of CAT 6A U/UTP cable suitable for 10G Ethernet applications, including termination at both ends with suitable connectors as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Fixtures
SITC of commercial integrated surface/recess LED down light fitting having color temperature having not less than 5700K, system lumen output not less than 1800 and system wattage not less than 18 - 24 W, CRI not less than 80, high transmittance diffuser, inbuilt electronic driver with surge protection not less than 2kV etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
SITC of 36W surface/Recess mounted LED panel light of size 60x60cm, housing made of powder-coated die-cast aluminium/extruded aluminium with white finish, operating on 220/240V AC, 50Hz with integrated high-efficiency LED module, CCT 5700K (cool daylight), CRI ;80, power factor 0.90, luminous efficacy 100 lm/W (minimum 3600 lumens), wide beam distribution, with inbuilt constant current electronic driver having surge and short-circuit protection, ingress protection minimum IP20, operating temperature ?10°C to +45°C, complete with all accessories as required, conforming to IS/IEC standards and with minimum 2 years warranty.
Supply, installation, testing, and commissioning of indoor LED strip light of high brightness SMD type with minimum 120 LEDs per meter, operating at 24V DC. The strip shall be flexible, linear type with high CRI (minimum CRI >80), and a minimum luminous efficacy of 90 lumens per watt. The strip shall be of IP20 rating suitable for indoor concealed or cove lighting applications and should have a lifespan of at least 30,000 hours. The strip shall be mounted inside an anodized aluminum profile channel with a translucent diffuser cover and proper end caps. Each strip light shall be powered through a suitable constant voltage LED driver (SMPS type) with short circuit and overload protection, and power factor & 0.95. The entire installation shall be completed with necessary connectors, mounting accessories, and wiring as required, as per site conditions and as directed by the Engineer-in-Charge.
DB and Switchgear
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 Way (4+12) Double door
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 100 Amp, 30 KA 4 Pole
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 40 amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
Supply and fixing following in the MCCB/MCB DB complete with connections, testing and commissioning etc, as required. 40 Amp TP MCB
10 KVA UPS
Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with inbuilt isolation transformer, 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase : Three Phase with ground b)Votage range 190 VAC 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range 200VAC 240 VAC ) Frequency range 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range 200VAC 240 VAC i)Frequency range 50/60 Hz j)Voltage distortion linear load <= 2% k)Voltage distortion nonlinear load <= 5% l)Output waveform pure sinewave m) Crest Factor 3:1 Minimum Back up time : Continuous 1 Hr at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand
Supply and Installation of 25 metre HDMI cable (2.0 or better). Make: Honeywell, Belkin, Manhattan
Supply, installation, testing and commissioning of Digital Podium with floor-mounted sturdy body, integrated minimum 21.5 Full HD touch display, in-built PC (Intel i5 or equivalent, 8 GB RAM, 256 GB SSD) and licensed OS. The podium shall include in- built audio amplifier and speakers, gooseneck microphone, and provision for wired/wireless microphones. It shall support HDMI, VGA, USB, LAN, Wi-Fi and Bluetooth connectivity and be compatible with projectors, interactive panels and video conferencing platforms. Complete with all required cables, accessories and software.
Supply, Installation, Testing and Commissioning of minimum 98 inch LED display, premium large-format 4K Smart TV not less than 98 with direct backlight technology (Mini-LED/Neo QLED/QNED), 3840×2160 resolution, high dynamic range support (including Dolby Vision or HDR10+), advanced image processing for natural color and motion clarity, wide viewing angles, and a robust smart platform; the unit shall include integrated high-quality speakers with support for immersive audio formats (e.g., Dolby Atmos), multiple HDMI 2.1/2.0 and USB inputs, network connectivity (Wi-Fi/LAN), and low latency for AV integration. The display shall be suitable for conference, presentation, and multimedia applications, with uniform brightness appropriate for ambient light conditions, a user-friendly OS (Google TV, webOS, or Tizen), and 3 year warranty support from the original manufacturer, each providing comparable picture quality, durability, and connectivity for shared seminar halls. Make: (Sony BRAVIA) or (LG evo AI QNED86 253 cm or Samsung QN80F Neo QLED 4K)
Supply, Installation, Testing and Commissioning of Wifi Access Point with superior 802.11ac performance (up to 1.2Gbps) 2 x 2 (Transmit x Receive) with 2 streams of data for 2.4 GHz (300 Mbps) and 5 GHz (1750 Mbps) of reliable data delivery 802.11ac beamforming to improve range, minimizes interference while maximizing data rates Internal antennas for maximum RF performance. including Wall / Ceiling Mount Kit for fixing access points With required licenses & OEM technical support / warranty along with required accessories
Supply, installation, testing and commissioning of 8-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbp Managed Switch, 60 Watts, 8 port- Edge PoE switch
Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete.
Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required.
Supply, Installation, Testing and Commissioning of Motorized Projector Screen of size 100 inch including mounting accessories and mounting the same on ceiling/wall as required by Site Engineer-in-charge.
Supply, Installation, Testing and Commissioning of Full HD DLP Multimedia Projector having Resolution Full HD (1920x1080 pixels), Brightness upto 3400 lumens, Contrast Ratio upto 16000:1, Lamp Life Minimum 10000 Hrs, Connectivity – HDMi, VGA, USB, Audio Ports, mounting kit and mounting the same on ceiling/wall as required by Site Engineer-in-charge, supply and providing HDMi cable of length 15m and integrating the same to the PC/Laptop provided at site. Make: BenQ TH575/ Epson EH-TW750
Air Conditioning System
Supply, installation, testing & commissioning of VRV/VRF 4 way Cassette type direct expansion inverter type indoor units with individual blade control for all the four directions including blower, TEFC blower motor, suitable for operation on 240 volts ± 10%,1 phase ,50HZ AC supply, copper tube aluminium finned direct expansion cooling coil, pre filters, electronic expansion valve with cordless remote and control wiring, drain connection with anti-vibration mountings, Fresh air connections etc. as required and as per scheduled of equipment and specifications. Power cabling upto 3 meters should be included. 3TR. Make: Mitsubhishi / Daikin/ Carrier
VRF drain Pipeline : supply and installation of PVC drain pipe includes bends , collar & elbow etc and dully insulated with 9 mm thick tubular insulation of closed cell elastometric nitrile rubber. Piping shall be supported by clamping on propoer support as required 25 mm PVC
Refrigerant piping : Supply ,installation ,testing & commisioning of OEM approved Hard Copper refrigerant piping of required sizes for gas (suction) & liquid,from outdoor units to various indoor units with all fitting ,supports and clamps (The piping system supported at 1 m distance.) Along with copper piping insulations with insulation material for higher efficency
VRF system Refrigerant pipeline : Supply , laying , testing & commissioning including vaccumiazation and nitrogen testing of 18G refreigerant copper pipes , pipe fitting , Y joints etc Insulation with 19/13 mm thick nitrile rubber of following size between outdoor unit to indoor unit to be supported with GI angle / flat supports as per the requirement Indoor Refnets
VRF system Refrigerant pipeline : Supply , laying , testing & commissioning including vaccumiazation and nitrogen testing of 18G refreigerant copper pipes , pipe fitting , Y joints etc Insulation with 19/13 mm thick nitrile rubber of following size between outdoor unit to indoor unit to be supported with GI angle / flat supports as per the requirement . ODU Brank kit
Supply and installation of VRF system with all required accessories . Each VRF should be provided with remote control for local operation. VRF out door unit 28 HP ( R134 / R410A or eco friendly gases) , weater resistant.
Electrical Cabling: Communication cable of (2C x 1 Sq.mm) with saddles/supports & PVC sheilded conduits to connect outdoor units with respective indoor units & remote controller units and (centralized remote controller if required)
Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation up to 3 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Blue Star/LG/ Carrier or equivalent). 1 TR 3 Star rated (inverter type AC) as per BEE
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Earthing
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Dismantling of the existing ductable split air-conditioning system comprising indoor and outdoor units, refrigerant piping, electrical wiring, ducts, drain lines, supports and all associated accessories. The contractor shall safely disconnect all electrical, control and communication cables; remove the indoor ductable unit along with its supply and return ducts, flexible connectors, hangers, vibration isolators and drain piping without causing any damage to the building structure. The outdoor condensing unit shall be dismantled and lowered from its mounting frame, including disconnection and removal of copper refrigerant piping, insulation, MS supports, anti-vibration pads and fasteners. All refrigerant in the system shall be recovered using an approved recovery machine and stored in certified cylinders as per environmental and safety norms. The contractor shall also remove all associated accessories such as cable trays, isolators, MS/GI supports and conduits. All dismantled materials shall be brought down carefully and stacked at the location directed by the Engineer-in-Charge.
Dismantling of existing surface/ ceiling fixtures, DB's, cables and wires as per the direction of Engineer in charge.
Dismantling and refixing of the existing network rack as per the direction of Engineer in charge.
Sprinkler System
Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Concealed sprinkler
Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts, bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 25mm
Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 32mm
Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 40mm
Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts, bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 50mm
Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts, bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 65mm
Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts, bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 80 mm
Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500 mm
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers, gaskets conforming to IS 13095 of following sizes as required:80 mm dia
Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 9890, at required locations. 25 mm dia Make : Kartar/Audco/Zoloto
Supply and installation of ISI approved ABC - powder type fire extinguisher - 4Kg with necessary clamp as required. Make: Safex, Ceasefire, Safepro
Drain the water from the existing fire header pipe and tap the sprinkler line from the header line by proper welding & recharge the line.(Cost including necessary materials/consumables)
Supply and fixing of photoluminescent Fire Extinguisher signage of standard size.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
IFB_JNC.pdf
Tender Documents • 2.35 MB
BOQ_304803.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid