Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | ₹23.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹23.2 L+₹20,156 (0.88%)Rejected-Finance | ₹23.2 L+₹20,156 (0.88%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹26.7 L+₹3.7 L (16.2%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | ₹26.7 L+₹3.7 L (16.2%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹28.3 L+₹5.3 L (22.9%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹28.3 L+₹5.3 L (22.9%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹32.4 L+₹9.4 L (41.0%)Rejected-Finance | ₹32.4 L+₹9.4 L (41.0%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
4 Jan 2021, 6:00 pmClosed
GE I DM
NAVAL DOCK YARD, VISAKHAPATNAM 530014
REPAIR, MAINT AND REPLACEMENT OF UNSERVICEABLE ITEMS OF 110 VOLTS BATTERY CHARGERS, POWER PACK, BATTERYS AND CERTAIN OTHER WORKS AT ND V
2020_MES_401572_1
SSGE/8395/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAVAL DOCK YARD, VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE I DM
₹70,000
Yes
4 May 2021
7 Dec 2020
9 Jan 2021
7 Dec 2020
4 Jan 2021
21 Dec 2020
Amount
Material and labour for servicing / repair/maintinance of battery bank 110V/30A comprising 55 Nos, 2 Volts VRLA batteries of any make/ rating in various sub-stations as follows : (a) Battery terminals to be checked and cleaned with petroleum jelly frequently i.e., every allternative 60 days. (b) Filling electrolyte level where applicable, check the battery voltage.
Disconnecting and taking down old damaged lead acid batteries from various sub-stations and supply & fix new maintenance free (VRLA) 2 Volts, 200 AH, batteries united/ fixed together with copper strips by series connection to make a battery bank of 110 V with initial charging and commissioning complete all as specified and directed. Make : Amara Raja only [Note : Unit rate quoted shall be deemed to be included for providing necessary battery connection links and control wiring from charger to HT panels].
S&F DC power pack on 11 KV VCB, capacity - 230 V AC input, 100V DC output , 150AH including necessary connection from AC input point and out put connection to VCB panel including dismantling taking out unserviceable one complete all as specified and directed.
Supply only Cap-Elec-2200 mdf-200V DC
Supply only CT-25/5A-Ring type-ID-30mm-2.5V A-CL5
Supply only Space heater-100W-240VAC
Supply only HBC fuse-slow-50A-660VAC offset tag
Supply only Glass fuse-fast-1A-250VAC-20MM
Supply only Semiconductor fuse-fast-25A-250V AC
Supply only Glass fuse fast 6A 250V AC 20MM
Supply only HRC fuse-slow-20A-415/550VAC-clip on
Supply only DC Voltmeter 0-150V -1.5-90D-(96)
Supply only DC Ammeter-50-0-50A/75mV-1.5-90D
Supply only DC Ammeter-0-40A/75mV-1.5-90D
Supply only AC Voltmeter -0-500V-1.5-90D-(96)
Supply only AC Ammeter-0-25A/5A-1.5-90D-(96)
Supply only PCB-MST-ACDB-48VDC
Supply only PCB-PLA-RL-130VDC
Supply only PCB-MST-UV/OV-RD-110V
Supply only PCB-CUR LIMIT-INT.FACE-130VDC
Supply only PCB-POWER SUPPLY BD-6P
Supply only PCB-REG CTRL-110VDC-6P
Supply only PCB GATE PULSE DRIVER-6P
Supply only PCBN-PLA-RELAY-12VCB-3C/O CONT
Supply only MCB-16A - 2P-DC-10KA
Supply only MCB-63A-2P-DC
Supply only MCB-32A-3P-10KA-AC-D-Cure
Supply only MCB-50A-2P-DC
Supply only Resistor-variable-2.5K-25k-25W-wire wound
Supply only POT-panel mount-20K-3W-1T
Supply only Dual SCR block-slow-25A-600V
Supply only PCB alram Bd-26V-43VDC-I/P-ARE02017023
Supply only Short cuircuit in AC Plat relay bases
Supply only Fuse trip indicators
Supply only PCB volt detect 48VDC TB
Supply only Capacitor Elect 7700MFD-200VDC
Supply, fix and testing indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply including providing controll wiring and taking down unserviceable indication lamps all as specified and directed. [Make:-L&T/binay/C&S]
Supply and fix copper cable single core of size 10 sqmm including terminals all as specified and directed. [Make:- Plaza/Polycab/Finolex].
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 25 Sqmm 3.5 core and connection complete with aluminium cable lugs including dismantling taking down unsv one all as specified and directed.
Material and labour for monthly cleaning of entire indoor substation buildings inside wall, ceiling, floor and outside wall, plinth protection with suitable brush/broom/wiper, removing wild vegitation around substation building complete all as specified and directed.
Material and labour for cutting/cleaning of wild vigitation etc., in and around outdoor eletric installations including disposal of spoil to a distance not excluding 500 Mtr outside the installation and carryout every alternate 30 days for the installations complete all as specified and directed
M/s Vinayaka Associates
KIRON ENGINEERING CORPORATION
GS ENGINEERS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .