Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAdmitted-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | ₹23.4 L | L1 | Admitted-Finance |
| 2 | L2₹24.6 L+₹1.2 L (5.06%)Admitted-Finance | ₹24.6 L+₹1.2 L (5.06%) | L2 | Admitted-Finance |
| 3 | L3₹24.8 L+₹1.3 L (5.71%)Admitted-Finance | ₹24.8 L+₹1.3 L (5.71%) | L3 | Admitted-Finance |
| 4 | L4₹25.4 L+₹2.0 L (8.39%)Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹25.4 L+₹2.0 L (8.39%) | L4 | Admitted-Finance |
| 5 | L5₹27.2 L+₹3.7 L (15.8%)Admitted-Finance | ₹27.2 L+₹3.7 L (15.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | REAL ENGINEERING WORKS L7 | SAI ENGINEERING WORKS L3 | Chitturi Associates L2 | SRI SIDDHI VINAYAKA ENTERPRISES L6 | SRIVALLI ENGINEERS L1 | COOL CONTROL L5 | GS ENGINEERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery etc., as per site requirement. | ||||||||||
| 2.00 | Carrying out Repairs, Maintenance & attending to breakdown of 5.5 TR to 11.6/12.5 TR capacity package type, air cooled AC plant as per the following scope of the work given below including carrying out general repairs / servicing to ensure smooth and trouble free operation of plants to the entire satisfaction of users / department complete all as specified and directed by Engineer-in-charge.
Scope of Work :
(a) Periodical monitoring/Inspecting the complete AC plant and carrying out preventive/ periodical maintenance to ensure smooth functioning of AC plant The periodical inspection for preventive maintenance shall be carried out by technician/ service engineer of authorized service provider once in a quarter other than breakdown calls for monitoring the operational condition of AC plant including for preventive maintenance/breakdown calls whenever required.
(b) Visual inspection for oil traces, Air heat exchanger (condenser) cleaning, check for removed protection devices, and improperly closed doors/covers, check that the temperature difference between the heat exchange inlet and outlet is correct, check the refrigeration system, motors and starters for performance and healthy condition of plant
(c) Checking the system for leaks and rectification of leaks if any.
(Contd...) | 15 | Each Job | 11,500 ₹1,72,500 | 6,500 ₹97,500 | 9,000 ₹1,35,000 | 30,000 ₹4,50,000 | 15,000 ₹2,25,000 | 15,000 ₹2,25,000 | 5,000 ₹75,000 Lowest |
| 2.01(Contd...) (d) Taking a set of readings and evaluating the same to ensure the satisfactory performance of the plant (e) Checking the refrigeration control system for operation and adjusting the settings as and when required (f) General Cleaning of the evaporator and condensing coils (g) General Lubrication of the bearings of motors, pumps and fans as and when required (h) Inspection of belts, which includes adjusting the tension including replacment if required (j) Filling only the refrigerant as a result of leak arising from the system due to standard wear and tear (k) Repairing / replacing the components of the equipment at site or at workshop as required (l) To check proper functioning microprocessor and take control test. (m) Intimating any breakdown requiring specific major repairs/overhauling to the contractor/ department for immediate rectification of defect. (n) Attending the complaints/breakdown whenever received by user/JE/Engineer in charge and attending the complaint for same within 24 hrs of receipt. (o) The repair / replacement of all spare parts like ICVC Boards, compressor / fan motor rewinding, electrical switch gears, contactors, PCB, refrigerant gas etc are not in the scope. These items shall be measured and paid separately under relevant items. (p) Any minor spares/ repairs items which are required to keep the plant in operational are deemed to be included in scope. | ||||||||||
| 3.00 | Supply and charge refrigerant gas R-22 with necessary materials like gasket / 'O' rings / washers complete all as directed by Engineer-in-charge. | 122 | KG | 1,550 ₹1,89,100 | 1,300 ₹1,58,600 | 1,600 ₹1,95,200 | 1,300 ₹1,58,600 | 1,200 ₹1,46,400 | 1,100 ₹1,34,200 Lowest | 1,250 ₹1,52,500 |
| 4.00 | M&L for complete leak testing the indoor and outdoor units, complete refrigerant pipe with nitrogen gas, locating the leaks, rectify the leak by brazing / welding and pressure testing the complete system for the capacity 5.5 to 12.5 TR air cooled / package AC system complete all as specified and as directed by Engineer-in-charge | 6 | Each Job | 16,500 ₹99,000 | 12,000 ₹72,000 | 9,000 ₹54,000 | 6,000 ₹36,000 | 5,000 ₹30,000 Lowest | 7,500 ₹45,000 | 5,000 ₹30,000 Lowest |
| 5.00 | M&L for cleaning main duct and sub duct including supply and return air grill, from AC plant to WT/DB-6/SES/Gykol Kupal/Signal Centre at each AC plant complete all as specified and directed by Engr-in-Charge. | 5 | Each Job | 4,900 ₹24,500 | 5,000 ₹25,000 | 14,000 ₹70,000 | 8,000 ₹40,000 | 3,000 ₹15,000 | 15,000 ₹75,000 | 1,000 ₹5,000 Lowest |
| 6.00 | S&F AHU blower motor of capacity 3 HP, including taking down existing un-serviceable AHU blower motor complete all as specified and directed. | 2 | Each | 18,500 ₹37,000 | 9,500 ₹19,000 | 14,000 ₹28,000 | 1,200 ₹2,400 Lowest | 9,000 ₹18,000 | 7,000 ₹14,000 | 20,500 ₹41,000 |
| 7.00 | S&F Outdoor fan motor of capacity 0.5 HP, including taking down existing un-serviceable outdoor fan motor complete all as specified and directed. | 2 | Each | 9,000 ₹18,000 | 6,000 ₹12,000 | 7,500 ₹15,000 | 800 ₹1,600 Lowest | 2,500 ₹5,000 | 7,200 ₹14,400 | 8,500 ₹17,000 |
| 8.00 | S&F Expansion valve of suitable size for package type AC, including taking down existing un-serviceable Expansion valve complete all as specified and directed. | 5 | Each | 7,000 ₹35,000 | 5,500 ₹27,500 Lowest | 5,500 ₹27,500 Lowest | 9,000 ₹45,000 | 5,500 ₹27,500 Lowest | 9,200 ₹46,000 | 10,500 ₹52,500 |
| 9.00Supply and fixing the following spares for carrying out repairs to package/VRF air conditioning unit of M/s Voltas / M/s Blue Star / M/s Carrier complete all as specified and directed by Engr-in-charge. | ||||||||||
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Aug 2026, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINTENANCE OF PACKAGE / VRF AC PLANTS AT INS DEGA UNDER AGE E/M NO-II OF GE(U-I) VISAKHAPATNAM
2026_MES_779232_1
8873/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹70,000
Yes
22 Aug 2026
17 Jul 2026
17 Aug 2026
17 Jul 2026
14 Aug 2026
1 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Carrying out Repairs, Maintenance & attending to breakdown of 5.5 TR to 11.6/12.5 TR capacity package type, air cooled AC plant as per the following scope of the work given below including carrying out general repairs / servicing to ensure smooth and trouble free operation of plants to the entire satisfaction of users / department complete all as specified and directed by Engineer-in-charge.
Scope of Work :
(a) Periodical monitoring/Inspecting the complete AC plant and carrying out preventive/ periodical maintenance to ensure smooth functioning of AC plant The periodical inspection for preventive maintenance shall be carried out by technician/ service engineer of authorized service provider once in a quarter other than breakdown calls for monitoring the operational condition of AC plant including for preventive maintenance/breakdown calls whenever required.
(b) Visual inspection for oil traces, Air heat exchanger (condenser) cleaning, check for removed protection devices, and improperly closed doors/covers, check that the temperature difference between the heat exchange inlet and outlet is correct, check the refrigeration system, motors and starters for performance and healthy condition of plant
(c) Checking the system for leaks and rectification of leaks if any.
(Contd...) | 15 | Each Job | - | - |
| 2.01 | (Contd...)
(d) Taking a set of readings and evaluating the same to ensure the satisfactory performance of the plant
(e) Checking the refrigeration control system for operation and adjusting the settings as and when required
(f) General Cleaning of the evaporator and condensing coils
(g) General Lubrication of the bearings of motors, pumps and fans as and when required
(h) Inspection of belts, which includes adjusting the tension including replacment if required
(j) Filling only the refrigerant as a result of leak arising from the system due to standard wear and tear
(k) Repairing / replacing the components of the equipment at site or at workshop as required
(l) To check proper functioning microprocessor and take control test.
(m) Intimating any breakdown requiring specific major repairs/overhauling to the contractor/ department for immediate rectification of defect.
(n) Attending the complaints/breakdown whenever received by user/JE/Engineer in charge and attending the complaint for same within 24 hrs of receipt.
(o) The repair / replacement of all spare parts like ICVC Boards, compressor / fan motor rewinding, electrical switch gears, contactors, PCB, refrigerant gas etc are not in the scope. These items shall be measured and paid separately under relevant items.
(p) Any minor spares/ repairs items which are required to keep the plant in operational are deemed to be included in scope. | - | - | - | - |
| 3 | Supply and charge refrigerant gas R-22 with necessary materials like gasket / 'O' rings / washers complete all as directed by Engineer-in-charge. | 122 | KG | - | - |
| 4 | M&L for complete leak testing the indoor and outdoor units, complete refrigerant pipe with nitrogen gas, locating the leaks, rectify the leak by brazing / welding and pressure testing the complete system for the capacity 5.5 to 12.5 TR air cooled / package AC system complete all as specified and as directed by Engineer-in-charge | 6 | Each Job | - | - |
| 5 | M&L for cleaning main duct and sub duct including supply and return air grill, from AC plant to WT/DB-6/SES/Gykol Kupal/Signal Centre at each AC plant complete all as specified and directed by Engr-in-Charge. | 5 | Each Job | - | - |
| 6 | S&F AHU blower motor of capacity 3 HP, including taking down existing un-serviceable AHU blower motor complete all as specified and directed. | 2 | Each | - | - |
| 7 | S&F Outdoor fan motor of capacity 0.5 HP, including taking down existing un-serviceable outdoor fan motor complete all as specified and directed. | 2 | Each | - | - |
| 8 | S&F Expansion valve of suitable size for package type AC, including taking down existing un-serviceable Expansion valve complete all as specified and directed. | 5 | Each | - | - |
| 9Supply and fixing the following spares for carrying out repairs to package/VRF air conditioning unit of M/s Voltas / M/s Blue Star / M/s Carrier complete all as specified and directed by Engr-in-charge. | |||||
| 9.01 | Sealed compressor of capacity 5.5 TR | 3 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8873Tender.pdf
Tender Documents • 0.76 MB
BOQ_872774.xls
BOQ • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .