Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.8 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING LOWEST TENDERER | |
| 2 | 2₹15.6 L+₹84,000 (5.69%)Rejected-Finance D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 2₹18 L+₹3.2 L (22.0%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 3₹18 L+₹3.2 L (22.0%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹29,600
Closing Date
25 Aug 2022, 6:00 pmClosed
AGE (I) (CG) Vizag
AGE (I) (CG) Vizag, Military Engineer Services, CGWO Building C/o Fleet Mail Office,Visakhapatnam 14
REPAIR MAINTENANCE OF VARIABLE REFRIGERANT FLOW VRF ACs AT ICGS MALKAPURAM VISAKHAPATNAM UNDER AGE I CG VIZAG
2022_MES_542526_1
AGE(I)CG/VIZ/TOKEN 19 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I CG VIZAG
₹29,600
Yes
17 Nov 2022
4 Aug 2022
27 Aug 2022
4 Aug 2022
25 Aug 2022
11 Aug 2022
Amount
Comprehensive Maintenance of (RPC Type) VRF AC casseets mounting set of the following capacities, which include replacement of filter, warn out parts, charging of refrigerant, Electric connection, MCBs, Control System, fault finding and its rectification and ensuring the system to work to the entire satisfaction of Engr-in-Charge. Make- Blue Star
Out door unit 22 HP and connecting pipe lines and Connected Indoor units Complete. Ser No - IVRFB-22TCNATF00024.
(b) Out door unit 24 HP and connecting pipe line and Connected Indoor units Complete. Ser No - IVRFB-24TCNCTF00106.
(c) Out door unit 28-2 Nos HP and connecting pipe line and Connected Indoor units Complete. Ser No - IVRFB-28TCNCTF00281 & IVRFB-28TCNCTF00274.
Comprehensive Maintenance of (RPC Type) VRF AC casseets mounting set of the following capacities which include replacement of filter, warn out parts, charging of refrigerant, Electric connection,control system,fault finding and its rectification and ensuring the system to work to entire satisfaction of Engr-in-Charge. Make- LG
(a) Out door unit 16 HP - 04 Nos and connecting pipe line and Connected Indoor units Complete. Ser No - 102PHDE006362, 102PHHS006353, 102PHCM006355 & 102PHLU006360.
(b) Out door unit 20 HP-3 Nos and connecting pipe line and Connected Indoor units Complete. Ser No- 102PHUP05382, 102PHXB002682 & 102PHNF005383.
(c) Out door unit 22 HP - 02 Nos and connecting pipe line and Connected Indoor units Complete. Ser No- 102PHRJ004886 & 102PHPL004888.
Notes for item 1 & 2 :- a) The Maintenance of the VRF Acs shall be done through OEM or firm authorised by the OEM only.
b) The parts being replaced/repaired shall be genuine and from original equipment manufacturer (OEM) and approved by AGE (I) (CG) Vizag.
c) All software update required for smooth functioning of VRF ACs shall be undertaken by OEM only.
d) Periodical Servicing of each VRF ACs to be carried out by Company technician and records/logbook shall be maintained with Engr-in-Charge.
e) The compressor will be checked for its proper functioning and if any defect is found,the same will be repaired/Replaced.
f) Safety control such as pressure cut outs will be tested for proper functioning and in case of any malfunctioning,they will be either repaired or replaced accordingly.
g) The PCB of the IDU & ODU will be tested for proper functioning and in case of any mal-functioning, they will be either repaired or replaced accordingly.
h) Air filter will be inspected and cleaned, if necessary.
j) Cooling coil will be inspected and cleaned, if necessary.
k) The blower motor will be checked and any defects noticed will be attended.
Note 2: The Rate quoted against the Item Nos. 1 & 2 shall be deemed to include all the above points specified vide item Nos.3 to 3.10 , nothing extra shall be paid to the contractor for carrying out the above services apart from the quoted rates.
P VENKATA RAO
ANAND ENTERPRISES AND ENGINEERS
SRIVALLI ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .