Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.0 LAccepted-AOC | ₹21.0 L Quoted ₹21.5 L | L-1 | Accepted-AOC Accepted |
| 2 | L-2₹23.1 L+₹1.6 L (7.37%)Rejected-AOC 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | ₹23.1 L+₹1.6 L (7.37%) | L-2 | Rejected-AOC Rejected |
| 3 | L-3₹23.1 L+₹1.6 L (7.58%)Rejected-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | ₹23.1 L+₹1.6 L (7.58%) | L-3 | Rejected-AOC Rejected |
| 4 | L-4₹23.8 L+₹2.3 L (10.5%)Rejected-AOC | ₹23.8 L+₹2.3 L (10.5%) | L-4 | Rejected-AOC Rejected |
| 5 | L-5₹24.0 L+₹2.5 L (11.7%)Rejected-AOC | ₹24.0 L+₹2.5 L (11.7%) | L-5 | Rejected-AOC Rejected |
Tender Value
₹19.8 L
EMD Value
₹39,600
Closing Date
12 May 2020, 6:00 pmClosed
GE AF BARRACKPORE
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR/MAINTENANCE OF CEILING FAN EXHAUST FAN GEYSERS FIRE ALARM SYSTEM AND ALLIED WORKS UNDER 6 WING JAFFARPORE KANCHRAPARA LOS DUM DUM AND BARASAT AREA UNDER GE (AF) BARRACKPORE
2020_MES_337053_1
8230/BKP/AF OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
6 Wing
Pls refer Tender document
5 documents required · 5 mandatory
₹500
Yes
GE AF BARRACKPORE
₹39,600
Yes
16 Jul 2020
1 Apr 2020
14 May 2020
1 Apr 2020
12 May 2020
16 Apr 2020
Amount
Taking down ceiling fan of 1200mm sweep, exhaust fan(300/380mm sweep), air circulator(400mm sweep) and pedestal fan(400mm sweep) by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of bush, bearing, condenser as directed by Engr-in-Charge. (Note :(i) Bush, bearing shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the item.
All as per Item No.1 here-in-before but ceiling fan of 1400 mm sweep exhaust fan(400/450mm sweep), air circulator(450mm sweep) and pedestal fan(450mm sweep)
M&L for painting of ceiling fan of 1200mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed by Engr-in-Charge. (Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 1 above)
M&L for painting of ceiling fan of 1400 mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed by Engr-in-Charge. (Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 2 above)
M&L for painting of exhaust fan/pedestal fan/air circulator any sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed by Engr-in-Charge. (Note :- Taking down and refixing of exhaust fan/pedestal fan/air circulator shall be measured and paid against item no 1 above)
Taking down/ dismantling complete ceiling fan of size 1200mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan including fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :-(i) Ball bearing and Gun metal bush shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the item (ii)Taking down and refixing of ceiling fan/exhaust fan/air circulator shall be measured and paid against item no 1 above)
All as per Item No.6 here-in-before but ceiling fan of 1400 mm sweep .
All as per Item No.6 here-in-before but exhaust fan of 300/380 mm sweep .
All as per Item No.6 here-in-before but exhaust fan of 400/450 mm sweep .
All as per Item No.6 here-in-before but pedestal fan/air circulator any sweep.
Repairs to ceiling fan (Old model) of size 1200/1400mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan including fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :-(i) Necessary lath machine work for Gun metal bush housing replace with ball bearing housing (ii) Ball bearing and Gun metal bush shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the item (iii)Taking down and refixing of ceiling fan/exhaust fan/air circular shall be measured and paid against item no 1 & 2 above)
Supply only for condenser 2/2.5 MFD .(Make ; Universal (Metal body)
Supply only for condenser 3.15/4 MFD .(Make ; Universal (Metal body)
Supply only for rubber bush for shakle with bolt ,nut and lock pin suitable for ceiling fan 1200 / 1400 mm sweep
Supply only for PVC holder for condenser housing
Supply only for ball bearing number of 6202 as required (Make-SKF/NBC)
Supply only for ball bearing number of 6203 as required (Make-SKF/NBC)
Supply only for ball bearing number of 6201 as required (Make-SKF/NBC)
Supply only for ball bearing number of 6204 as required (Make-SKF/NBC)
S&F ceiling fan spindle complete all as specified and directed.
Supply only gun metal bush as required
S&F single pole and neutral enclousure with a two pin and earth plug and socket complete with one single pole MCB 240 Volt, 20 amp.Make-Legrand/HPL/L&T
S&F for metal clad industrial plug of 20A rating 250 V .Make-Legrand/Havells/HPL complete all as specified and directed by Engr-In-Charge.
S&F for metal clad industrial socket of 20A rating 250 V .Make-Legrand/Havells/HPL complete all as specified and directed by Engr-In-Charge.
S&F for power units complete with 4 module complete plate, 25 Amps starter,25A socket and plug and surface mounting plastic boxes 4 module in repair .(Make-Crabtreeor equivalent of Anchor)
S&F for PVC insulated and sheathed flexible wire 3 core with copper conductor 4 sqmm round type for gyser .(Make-Finolex/Havells/)
S&F for GI tubing 15mm bore (medium grade)with all fittings and fixed complete to wall ceiling with all fitting arrangement and ceiling connection with the existing gyser as in repair .(Make ; Jindal /Surya)(Note-Making good the wall surfaces match with the existing position)
S&F for Gun metal non return valve 15 mm dia .Make-;ISI Marked)
M & L for angular stop cock with wall flange 15 mm dia all as specified and directed.
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area,FR multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete surface/concealed including provision of 1X10.0 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified.(Make- Finolex/KEI/Havells for Copper cable and Make- Prestoplast/Plaza for conduit and accessories). ( Note :-1. Extra length of cables/ wire required for connection to MCBs/DB's shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly 2. For Concealed wiring Cutting chases,chipping and plastering mesured and paid seperately under relevant items).
M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area,FR multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete surface/concealed including provision of 1X6.0 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified. (Make- Finolex/KEI/Havells for Copper cable and Make- Prestoplast/Plaza for conduit and accessories)( Note :-1. Extra length of cables/ wire required for connection to MCBs/DB's shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly 2. For Concealed wiring Cutting chases,chipping and plastering mesured and paid seperately under relevant items).
M & L for mini steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc all as specified and directed.(Make-Anchor/Plaza)
M & L for Delux steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc all as specified and directed.(Make-Anchor/Plaza)
M&L for modular fan regulator ,step type ,120 Watt,W-2 module complete all as specified and directed by Engr-In-Charge.
M&L for wall/air circulator/stand fan PVC blades 300 mm sweep complete all as specified and directed by Engr-In-Charge.
M&L for wall/air circulator/stand fan PVC blades 350/380 mm sweep complete all as specified and directed by Engr-In-Charge.
M&L for exhaust fan louers with shutters suitable for 300/380/450 mm sweep for exhaust fan complete all as specified and directed by Engr-In-Charge.
M&L for exhaust fan blade (metal body) suitable for 300/380/450 mm sweep for exhaust fan complete all as specified and directed by Engr-In-Charge.
M&L ceiling fan, fan blade suitable for 1200 mm sweep for complete all as specified and directed by Engr-In-Charge.(Note- Fan Blades issued under schedule B free for fixing only & matches as per sample/ground only)
M&L ceiling fan, fan blade suitable for 1400 mm sweep for complete all as specified and directed by Engr-In-Charge.(Note- Fan Blades issued under schedule B free for fixing only & matches as per sample/ground only)
M & L for 50x6mm thickness MS strip with nut,bolt and washers suitable for fixing of ceiling fan and all as specified and directed
Taking down the rusted down rod of ceiling fan of size (1') ,and S&F new down rod to any height including two coats of synthetic enamel paint complete all as specified and directed by Engr-In-Charge.
Taking down the rusted down rod of ceiling fan of size (2') and S&F new down rod to any height including two coats of synthetic enamel paint complete all as specified and directed by Engr-In-Charge.
S &F the canopy suitable for ceiling fan of existing type & size complete all as specified and directed by Engr-In-Charge.
M& L for GI tubing 40mm bore medium grade for fixing of ceiling fans and make good the disturbed wall surface and all as specified and directed.
M& L for 15 A plug top 3 pin with all as specified and directed
M & L cutting chases, chipping in, making god to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge.
M&L for PVC insulated Single core 1.5 sqmm 3 core multi strand copper conductor complete all as specefied and as directed.Make- Finolex/Havells/Harsh
Removal of UNSV and S&F Plastic body Exhaust fan 250 mm sweep pearl white in colour suitable for 230 volt 50Hz complete all as specified and directed.Make-Usha/CG/Havells
ROY CONSTRUCTION
R K CONSTRUCTION
APOLLO TRADERS
BHAUMIK CONSTRUCTION
JAGATRAM CONSTRUCTION
SITARAM CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .