Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC C 23 CC | ₹7.8 L Quoted ₹7.9 L | L1 | Accepted-AOC 1st Lowest |
| 2 | L2₹8.3 L+₹40,013.25 (5.08%)Rejected-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.3 L+₹40,013.25 (5.08%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹9.2 L+₹1.3 L (16.2%)Rejected-Finance VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹9.2 L+₹1.3 L (16.2%) | L3 | Rejected-Finance 3RD LOWEST |
Tender Value
₹10.0 L
EMD Value
₹19,980
Closing Date
27 Apr 2024, 6:00 pmClosed
AGE (I) Raiwala
AGE (I) Raiwala
COMPREHENSIVE MAINT TO OFFRS ACCN IN SOUTH COLONY INCL WELCOME MAINTENANCE, JOINERY TILING INTERNAL WIRING AND SWITCHES ETC
2024_MES_648104_1
8919/E8
Open Tender
Civil Works
Works
180 days
AGE (I) Raiwala
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE (I) Raiwala
₹19,980
Yes
12 Jun 2024
28 Mar 2024
29 Apr 2024
28 Mar 2024
27 Apr 2024
6 Apr 2024
28 Mar 2024 - 3 Apr 2024
Amount
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each.
Refixing of shutters in same opening of any descrption after easing and adjusting , n exc 1.50 Sqm.
Refixing of shutters in same opening of any descrption after easing and adjusting , exc 1.00 Sqm but n exc 2.00 Sqm.
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each .
Taking down shutters of any description n. exc 1.00 sqm each.
MS Fastner of size 200 to 250mm for fixing wooden door / window frame and like in postion
S & F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S & F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
M&L 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. Note- S S Butt hing measured and paid separately at relevant item
S & F for stainless steel barrel tower bolt of 200 mm length of extruded section (ISI Marked). Complete all as specified and directed
S & F for stainless steel barrel tower bolt of 300 mm length of extruded section (ISI Marked). Complete all as specified and directed
S & F, in repair, for stainless steel barrel tower bolt of 300 mm length of extruded section (ISI Marked). Complete all as specified and directed
S&F for stainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked) all as specified and directed.
S&F for stainless steel handles,fabricated type, anodised 125 mm long,(ISI Marked) all as specified and directed.
S&F, in repair, stainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked) all as specified and directed.
S & F for stainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed.
S & F for stainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed. fixed in repair.
S&F Stainless non megnetic steel butt hinges of size 100mm.(ISI Marked). Complete all as specified and directed by Engineer in Charge
S & F for Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm.
S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete.
S&F in repair 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete.
S & F for Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples, fixed in repairs.
M & L in repairs for Plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 3 Sq.cm and not exceeding 6 Sq.cm, square, rectangular or triangular in section, clean sawn secured with nails.
S&F in repairs for stainless steel non magnetic curtain rod 20 mm dia with fixing brackets and decorative type knobs both side of each rod. Note: - Measurement will be taken between end point of knobs”
S & F in repairs of aluminium door seal upto 1200 mm long on bottom of door
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one.
S & F for Glazing with plain sheet glass, ordinary quality, 5.5 mm thick and glazing with oil putty or aluminium or PVC beading in squares n. exceeding 0.5 Sq.m in each pane.
S & F for Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane.
S&F in repairs S S peg set, 150 mm complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
M&L for Non- skid coloured ceramic tiles of any design and pattern, 300X300X7 to 8 mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE .Complete all as specified and directed
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) .Complete all as specified and directed
Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required .
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 75 mm bore PVC (SWR) bends of any radius
S & F 75 mm bore PVC (SWR) bends of any radius with access door
S & F 110 mm bore PVC (SWR) bends of any radius
S & F 110 mm bore PVC (SWR) bends of any radius with access door
S & F PVC (SWR) reducers of size 110 mm x75 mm
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 75 mm bore PVC (SWR) Vent Cowl
S & F 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement
S & F 110 mm bore PVC (SWR) P Trap
S & F 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement .
S&F stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe, complete all as specified and directed.
S&F stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe, complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelves etc.Complete all as specified and directed
M & L of 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick work
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .
M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
S & F in repairs Sinks with drainage board made of stainless steel 0.8mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 and bowl size 410mm x 330 mm x 160mm.
S & F in repairs Sinks with out drainage board made of stainless steel 0.8mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 495 mm x 420 and bowl size 410mm x 330 mm x 160mm.
S & F in repair to Stainless steel kitchen plate rack 0.80mm thick sheet of over all size 31" x 30" x 10" fixed with steel screws and steel rawal plugs
S & F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions.
S & F in repairs Stop angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete (fixed in repairs) .
S & F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule
S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe
S&F in repairs towel Rail 600 mm long fixedwith and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms)
S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union
S & F , in repair, Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.
Supply and fix in repair to glass corner shelf of size 300mm fixed with chromium plated brass brackets complete all as specified and directed.
S&F in repair for PVC Connections 15mm size with PTMT nuts of length 600 mm
S&F in repair Wash basins (Padestal pattern) 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting
S&F in repair Wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting
S & F in repairs for Grating ,round 127 mm dia chromoum plated
S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed
S&F in repairs Vitreous china Squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor .
S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete
M & L in repair S S Jet spray with 1.5 mtr braided tube complete all as specified and directed
S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair.
Supply & fix in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed.
S&F in repairs towel rack fixed with and including CP brass screws and wooden/plastic cleats,complete all as specified and directed.
S&F in repairs Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia all as specified
S&F in repairs toilet paper holder chromium plated fixed to wall with chromium plated (CP) brass screws
S & F in repair Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
Supply & fix in repair to chromium plated towel ring complete all as specified
S&F in repair 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc.
S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) incl close seat cover, hinges,fixing accessories and accessories set and cistern with cistern fitting complete, flush pipe incl all joints Make Jaquar Essco Cat part no ECS-WHT-851S220NPP or equivalent modle of make MARC or Hindware complete all as specified and directed.
M&L for preparation of old decorated surface of exterior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge. Note (i) The old/ New surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) Before commencing the work, contractor will got the written approval from GE/ AGE (I) for the make and colour / shade (tint). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over one coat of wall puttyusing roller all as specified and prescribed by manufacturer of paint Ist Quality and all as directed at site by Engr-in-Charge . Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of exterior wall and applying one coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc ) all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge. Note (i) The old/ New surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of paint. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
Taking down cement plaster on brick , concrete or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed.
M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and fair complete all as specified and directed.
M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge. Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed. Note :- WPC (Liquid type) shall be measured and paid separately as supply only.
Supply only Liquid intergal water proofing compoud
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M/L preparation of old surface of ceiling plastered including cornices and pillasters etc and applying one coat of white wash on ceiling all as specified and as directed by Engr-in-Charge.
M&L preparation of old painted surface of wall and applying one coat of oil bound distember all as specified
M&L preparation of old painted wooden surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed .
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated wood and wood based sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality over a one coat of pink primer complete all as specified and directed.
M&L preparation of old painted steel surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed .
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality over a one coat of red oxide complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISImarked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per above item No.1 above but for existing concealed conduit inside wall, ceiling etc(light, fan, call bell) complete all as specified and directed .
All as per above item No.1 but for existing concealed conduit inside wall, ceiling etc but for One 3pin/5pin 5/6 Amps socket out let on same board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per above item No.1 but for existing concealed conduit inside wall, ceiling etc but forOne 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per above item No.1 but for existing concealed conduit inside wall, ceiling etc but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed .
All as per Item No 1 above but for existing concealed conduit inside wall, ceiling etc with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed .
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian or equivalent make of L&T/ Cona
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian or equivalent make of L&T/ Cona
Supply and fix Modular Socket outlet, 6A - 3 pin, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian or equivalent make of L&T/ Cona
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian or equivalent make of L&T/Havells
Supply and fixing switch modular type single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian or equivalent make of L&T/ Cona
Supply and fixing bell push modular type single pole one way 6 Amps, 1 module with with indicator, ISI marked all as specified. Legrand, Indoasian, L&T, Cona
Supply and fixing step socket type modular fan regulator 120/280 V 2 module with indicator, all as specified. Make: Legrand, Indoasian, L&T, Cona
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals all as specified
Supply and fixing in repair Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings all as specified and directed. Anchor, Cona or equivalent in Havells
Supply and fix in repairs /replacement switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked all as specified and directed.Anchor, Cona or equivalent in Havells
Supply and fix in repair/replacement switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way -ditto-.Anchor, Cona or equivalent in Havells.
Supply only in repairs/replacement, socket out let 3/5 pin 5/6 Amps flush type Anchor, cona or equivalent in Havells .
Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC all as specified and directed of ISI marked Anchor, cona or equivalent in Havells .
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
Supply and fixing in repair bell ding dong AC 230 volts single pole
Suupply and fixing in repair step socket type fan regulator 120/280 V , ISI marked all as specified and directed by Engr-in-Charge.
Material and labour for repair and replacement of existing rusted metal circuit box including hylam sheet and switch, sockets, regulators with new 1/ 2 way-8 way modular type metal box with and incl decorative polycarbonate frame for housing modular switches, sockets, fan regulatrs etc including white cover plate complete and connect existing circuit wiring with new switches & testing complete all as specified and directed.Note:- 1 payment will be done for each module as per rates quoted by the contractor 2.switch /sockets /regulators will be paid seperately.
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box excluding conduit when in wiring in existing conduit, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
TARUN ENGINEERING WORKS
AMAR NATH SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .