Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.1 LAccepted-AOC | 1 | Accepted-AOC lowest | |
| 2 | 2₹16.6 L+₹48,272.26 (3.00%)Rejected-AOC KANNAMBRA P O PALAKKAN DIST KERALA | PALAKKAD | KERALA | 678001 | 2 | Rejected-AOC 2nd | |
| 3 | 3₹17.4 L+₹1.4 L (8.52%)Rejected-AOC IMAGE CRAFT KANNANKAM CHELARI ANGADIPURAM 673616 | ANGADIPURAM | MALAPPURAM | KERALA | 673616 | 3 | Rejected-AOC 3rd | |
| 4 | 4₹19.0 L+₹2.9 L (18.3%)Rejected-Finance | 4 | Rejected-Finance 4TH | |
| 5 | 5₹19.4 L+₹3.3 L (20.5%)Rejected-Finance | 5 | Rejected-Finance 5TH |
Tender Value
₹20.4 L
EMD Value
₹50,000
Closing Date
27 Mar 2025, 4:00 pmClosed
SECRETARY
SECRETARY PANANCHERY GP
114/2024-25-RENOVATION OF DRINKING WATER SCHEME
2025_LSGD_725296_11
1/2025/SDFMLA
Open Tender
Civil Works - Water Works
Item Rate
180 days
PANANCHERY PT
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
Yes
₹50,000
Yes
26 Jun 2025
20 Mar 2025
29 Mar 2025
20 Mar 2025
27 Mar 2025
20 Mar 2025
20 Mar 2025 - 27 Mar 2025
Amount
OD449819/2024-2025:Digging of bore well of 150mm dia size for various stratas upto 110m below the ground level inclusive of hire charges of machinery and other accessories and stones,cost of fuels,oil and other incidental items to complete the work .
OD450037/2024-2025:Supplying and fixing 180mm PVC casing pipe (8kgf/cm2) in to the bore well including cost and conveyance of materials fixing charges etc. complte.
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
50.18.8.8.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
OD396655/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
18.19.4.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
50.18.8.5.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2
50.18.8.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2
50.18.9.3.2:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
50.5.7:Reinforced cement concrete work in well-staining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1. 5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
OD458404/2024-2025:supply and errection of Ferro cement pump house as per following specifications.a) Foundation of size 1.60x1.60x0.60m ferro cement square fitting by earth consolidation connecting using cement concrete 1:4:8, b) Ferro cement ready made wall of size 1.50x1.50m (square type) having an average thickness of 25mm and height 2.10m, c) Ferro cement ready made roof d) M.S. door with necessary fittings 90x210cm size painting with synthetic enamel paint two coat after a priming coat includingf supplying a pad lock e) , painting with synthetic enamel paint two coat after a primary coat f) white washing two coat with cement proof paint two coat on inside and outside of pump house including roof
50.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
51.18.12.7:Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately) <br> External work - 65 mm nominal dia
10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
SIDDIK (BID ID -2179348)
SHIJULAL M (BID ID -2178086)
V.M.MAJEED (BID ID -2179138)
K.M.SHAJI (BID ID -2179178)
Bidder Name
Hakkeem N
SHIJULAL M
V.M.MAJEED
K.M.SHAJI
SIDDIK
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .