| 1 | L1₹34.9 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.7 L+₹5.5 L (15.8%)Rejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹42.7 L+₹7.6 L (21.5%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹44.5 L+₹9.4 L (26.6%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹44.9 L+₹9.8 L (27.9%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Dec 2023, 6:00 pmClosed
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
REPAIR MAINTENANCE OF WATER SUPPLY INSTALLATION OF STP MAINT SOLAR WATER HEATER REPAIR REPLACEMENT OF PUPMS REPLACEMENT OF PIPE LINE ANNUAL MAINTENANCE OF DG SET AND MISC ITEMS AT DHQ 01 ICGRA DHARMAPUR UNDER GE(I) CG PORBANDAR
2023_MES_630773_1
8954/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
PORBANDAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹70,000
Yes
31 Jan 2024
2 Dec 2023
28 Dec 2023
2 Dec 2023
26 Dec 2023
19 Dec 2023
Amount
SCHEDULE 'A' E/M ITEMS
Material & Labour for pumping out sewage water from the existing sumps/tanks of STPs (MBBR technology) with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with tanking out mud/ solid sludge from the tank complete from soild sepration chamber, aeration chamber and despose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the main non clogging pump sets installed in the STPs, complete all as specified and directed by Engineer-in-Charge. Location : CGRA Dharampur & CGRA Ianz Note :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of STPs towards the main gravity dropping main hole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the rate. (e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) Rate included for transportation of pump set to site/back.
Material & Labour in PP floating media to top up for bio reactors, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Carry out water testing of bacterial, chemical and biological analysis of sewage water treated water from NABL accredited Govt approved lab for following parameters and submission of test reports, complete all as specified and directed by Engineer-in-Charge. Location : CGRA Dharampur & CGRA Ianz (a) PH (b) Chemical Oxygen demand/COD (c) Biological Oxygen Demant/BOD (d) Total Suspended solids (e) Oil and grease (f) TKN (g) Total Coliform (h) Organism MPN (k) Dissolved Oxygen Note: Every Quarterly water testing shall be carried out as per CA Qty in period of contract all as directed without fail else recovery will be made at Rs 15000/- per test for execution of item and for non-submission of Test Report.
Materisl & Labour for Water Testing, Collecting the sample of water at Pump house and testing of water for iron, PH value, TDS, colour, Total Hardness, chloride, Chlorine, fluoride, Coliform, arsinic test and submitting the test report from reputed laboratory, complete all as specified and directed by Engineer-in-Charge. Location : CGRA Dharampur & CGRA Ianz
Supply only Sodium hypochloride Calcium based, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 %, complete all as specified and directed by Engineer-in-Charge. Make Rayalseema, Brand Puri chlor
Supply only Hypochlorous Acid net wt 38 kg, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % and delivered at STP, complete all as specified and directed by Engineer-in-Charge. Make: Aditya birla
Supply only bleaching powder suitable for water disinfection, complete all as specified and directed by Engineer-in-Charge.
Dismantling Sewage submersible pumping set of cap 3 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Dismantling Sewage submersible pumping set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Taking down air blower of Air blowers with working pressure 0.3 Kg/cm2 alongwith motor of capacity 5 HP with blower pipe of size 3", from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower throughly including machine work and re-assembling the air blower and commssioning testing complete on full load, complete all as specified and directed by Engineer-in-Charge. (new spares will be measured and paid separately).
Material & Labour for taking out & servicing of existing unserviceable Air Blower (of any Make) of capacity 5.00 HP pressure 0.3 Kg/cm2 with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs, complete all as specified and directed by Engineer-in-Charge. (i) Spare part required for replacement shall be measured and paid separetly under relevent items (ii) Replacement of Oil seal, locking arrangement of pully, gland packing with oil and greasing shall be deemed to be including in the quoted rate of this item.
Supply & Fixing replacement of "V" Belt (SPA 1250) unserviceable /worm-out 'V' belt of air blower etc., complete all as specified and directed by Engineer-in-Charge. Makes:- Fenner/Dunlop/Nerlon/Super flix/Ecodrive.
Material & Labour in replacement of Gear oil 90 EP, Pressure Gear Oil etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement air-filter for blower suitable size for existing air-filter etc., complete all as specified and directed by Engineer-in-Charge.
Supply only Grease 30K, for using ensure protection of metal surfaces extending bearings, Hinges etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for finding out defect of STPs panel and taking out burnt interconnection wiring including U/S and serviceable component for re-use including rewiring of panel using existing size of copper cable, ferrule, lugs, insulating materials, nut bolts washer of various sizes refixing serviceable items, complete all as specified and directed by Engineer-in-Charge.
Taking up/down CI/DI pipes with connection from trenches incl connected fittings/accessories complete of 150 mm bore size and removing the pipes and reused to site, complete all as specified and directed by Engineer-in-Charge.
Taking up/down CI/DI pipes with connection from trenches including connected fittings/accessories complete of 80/100 mm bore size and removing the pipes and reused to site, complete all as specified and directed by Engineer-in-Charge.
All as per Item Sl No.18 here in before but of size 100 mm bore
All as per Item Sl No.18 here in before but of size 80 mm bore
Supply, laying and replacement of jointing in trenches DI pipes class K-9 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 150 mm dia ISI, complete all as specified and directed by Engineer-in-Charge.
Supply, laying and replacement of jointing in trenches DI pipes class K7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 100 mm dia ISI, complete all as specified and directed by Engineer-in-Charge.
Supply, laying and replacement of jointing and testing of Class LA Cast iron pipes 80 mm dia ISI marked with standard length spigot and socket ends centrifugally cast, push type joint with run lead joint, in any length, laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply, laying and jointing tubing medium grade galvanised iron pipes of size 80 mm, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 50 mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of size 50mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement of ISI marked ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 80 mm dia to 150 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch,cross collars, caps and plug set including rubber ring push on joints, complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 150mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 100mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 80mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engineer-in-Charge.
Dismantling monoblock pump set centrifugal type of cap 20/25 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Dismantling monoblock pump set of cap 10 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Dismantling open well type monoblock pump set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Dismantling/taking down bore well submersible pump set of cap 4/5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enameled copper wire as per existing gauge re-fixing the same at site including . Electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. Note : Cost of dismantling/taking down of bore well pump and re-fixing deemed to be included in quoted rate.
Supply and fixing in replacement of Flexible Flat of size 2.5 Sqmm 3 core, PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade including drawn through HDPE/PVC conduit of size 25 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to light etc, including taking down old unsv cable, complete all as specified and directed by Engr-in-Charge. Make :- Polycab/RR Kable/Havells /Finolex Note: 1. Conduit, saddles & small excavation of cable in gardens deemed to be included in the quoted rate.
Supply and fixing in replacement of Flexible heavy duty of size 10 Sqmm 3 core PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade including drawn through HDPE/PVC conduit of size 32 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking down old unsv cable, complete all as specified and directed by Engr-in-Charge. Make :- Polycab/RR Kable/Havells//Finolex Note: 1. Conduit & saddles deemed to be included in the quoted rate.
Supply & Fixing in replacement of Round strand Galvanized Iron Steel Wire Rope dia 8 mm and connected clamp nut bolts fixed etc, including taking down old unsv cable, complete all as specified and directed by Engr-in-Charge.
Servicing of DG set ('C' Check) of Cap 50/62.5 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. Make of DG set: Ashok Leyland Note: Defective parts if any other than listed at (a) to (b) above will be measured and paid separately
Supply only parts/ Items of DG set 50/62.5 KVA Make : Greaves Cotton & Kirloskar
Oil Filter
Fuel Filter cum water seperator
Air Filter Safety
Air Filter Primary
Coolant
Engine Oil
Fuel strainer
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 50/62.5 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement battery heavy duty 12 Volts 80 AH maintenance free, complete all as specified and directed by Engineer-in-Charge. Make : Exide/Amron/Cummins
Taking down unserviceable battery charger and supply and fixing new automatic electronic battery charger, 10 Amps, 12 Volts including making electric connections and to be housed in AMF panel, complete all as specified and directed by Engineer-in-Charge. Make:- Maha mai / Span /Vinitech/NHP
Supply & Fixing in replacement of battery terminal, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair digital type Frequency meter, complete all as specified and directed by Engineer-in-Charge. Make :-L&T/ AE/IMP
Supply and fix in repair digital type volt meter, complete all as specified and directed by Engineer-in-Charge. Make :-L&T/ AE/IMP
Supply and fix in repair digital Ampere meter with CTs, complete all as specified and directed by Engineer-in-Charge. Make :-L&T/ AE/IMP
Spray Painting of Pump & Motor any type, any capacity upto 25 HP as per colour code (Shade) of MES specification after cleaning the dust particle of existing motor & Pump, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Cleaning of semi under ground RCC sump of capacity 1,00000 gallons throughly removing mud, grits etc. from the sump by following method: - (a) Removing all dirt, mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs. (c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars and floor & removing mud and grits & deposits etc properly. (d) Repair/Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof. (e) Dry washed walls, coating with a one coat of white cement inside the whole surface of walls/pillars and floor of sump. Note: 1. Consumption of bleaching powder for cleaning of tank shall not be less than 60 Kgs, deemed to be included in unit rate. 2. Minor repair/ replacement of inlet & outlets of any tpye / size of pipes, fixed in original position deemed to be included in unit rate.
Dismantling and opening the Chemical dosing pump from the existing position for servicing from authorised compeny and refixing the same in original position and testing and commissioning the pump, complete all as specified and directed by Engineer-in-Charge.
Maintenance/ Repairs of RO Plant Cap 150LPH installed at OTM Complex including cleaning and replacement of sedimatation filter and carbon block, Membrane Element, Antiscalent chemical and Miscellenous Items etc., including taking down old unsv materials, complete all as specified and directed by Engineer-in-Charge.
Maintenance/ Repairs of RO Plant Cap 2000LPH installed at Inaz Village including cleaning and replacement of sedimatation filter, Micron Cartridge Filters and carbon block, Membrane Element, Antiscalent chemical and Miscellenous Items etc., including taking down old unsv materials, complete all as specified and directed by Engineer-in-Charge.
Maintenance/ Repairs of Automatic axis control Barrier (IP44) for beam length 6m (Beam Max), activation system comprising hydrant pump unit, plunger, piston equalizer and transmission shaft, balancing by compression spring, single phase 230 volt, AC supply operated, Bi-directional motor complete, including taking down old unsv materials,complete all as specified and directed by Engineer-in-Charge.
Material and labour for maintenance of solar water heating system flat plate type including all water and electric connections of capcity 100 Ltrs per day and refixing the same in existing position after the following repairs and testing complete :- Location : CGRA Dharampur, Inaz Vig. (a) Replacement of the worn out/missing nuts bolts, washers, unions, sockets flanges and screw etc complete. (b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convetor sets throughly cleaning the complete solor pannel of making the tube scale free and reassemling the pannel. (c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete. (d) Repair of collector fins incl required welding works etc complete. (e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects. (Note : Cost of dismantling and refixing and minor repairs deemed to be included in quoted rate.
All as per item No. 53 here in before but of capacity 200 ltrs per day, complete all as specified and directed by Engineer-in-Charge. Location : CGRA Dharampur, Inaz Vig.
All as per item No. 53 here in before but of capacity 300 ltrs per day, complete all as specified and directed by Engineer-in-Charge. Location : CGRA Dharampur, Inaz Vig.
Material and Labour for painting the MS supporting structure of solar water heating system complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., complete all as specified and directed by Engineer-in-Charge. Location : CGRA Dharampur, Inaz Vig.
Material and Labour for painting the MS supporting structure of solar ON Grid power plant complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., complete all as specified and directed by Engineer-in-Charge. Location : DHQ No1, Inaz Vig, OTM Complex.
Supply and fixing in replacement of PVC Suction hose pipe at STP, working pressure 10 Kg/Sqcm of size 50/63 mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC foot valve assembly complete of suitable size for pipe of size 50/63 mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Butterfly valves lever operated body grey cast iron of size 65mm bore, with all fittings confirming to IS specification, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Butterfly valves lever operated body grey cast iron of size 50 mm bore, with all fittings confirming to IS specification, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of non return valves (NRV) body grey cast iron of size 50/63 mm bore, with all fittings confirming to IS specification, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for laying in replacement of High density polyethylene(HDPE) pipes of pressure rating 6 kgf/sq. cm of size 50 mm dia laid in treanches including taking down the old u/s pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of CPVC pipes of size 50 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and directed by Engineer-in-Charge. Make: Supreme/Astral/Finolex
Supply and laying in replacement of CPVC pipes of size 32 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and directed by Engineer-in-Charge. Make: Supreme/Astral/Finolex
Supply and laying in replacement of CPVC pipes of size 25 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and directed by Engineer-in-Charge. Make: Supreme/Astral/Finolex
Supply & Fixing in replacement of Ball Valve of 50 mm Dia Long Handle of size Supply and laying in replacement and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration any required for fixing and making good, complete all as specified and directed by Engineer-in-Charge. Make: Supreme/Astral/Finolex
All as per above Item, but size 32 mm dia, all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
All as per above Item, but size 25 mm dia, all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
Supply & Fixing in replacement of Automated Landscape Irrigation System, System consists of Pop up Sprinkler of 2.5 to 3 Mtr Radius water sprayer Irrigation System, 0 - 360 Degree part-Circle with complete accessories, Controls with automation components, including making good, complete all as specified and directed by Engineer-in-Charge. Make: Rain-Bird (Spray Popup)
Supply & Fixing in replacement of disc filter of Size 50 mm dia and connected to two ends externally for CPVC pipe or for unions and fixed complete and including filter chamber of size 300 X 300 X 300 mm including necessary earth work in any type of soil, necessary excavation earth work all plastered surfaces of filter chambers and making good, complete all as specified and directed by Engineer-in-Charge. Make: Rain-Bird
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out Hard/ dense soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for dismantiling the existing valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth work all plastered surfaces of valve chambers, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of LED Bollard 11W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, 50 Hz, pole mounted, including PCC 1:2:4 type B1 (20 mm graded aggregate) base of size 300mm x 300mm and depth 600mm for fixing of Bollard with nuts bolts etc required as per site, complete all as specified and directed by Engineer-in-Charge. Make : Wirpo / Philips/CG/Bajaj Note: Apply for single coat of suitable colour distempering for bollard foundation shall deemed to be included in the quoted rate.
Supply & Fixing in replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted, including PCC 1:2:4 type, base of size 300mm x 300mm and depth 500 mm for fixing of Bollard with nuts bolts etc required as per site, complete all as specified and directed by Engineer-in-Charge. Make : Crompton / Bajaj/Wipro/Philips
Supply & installation/ in replacement of out door signage board box type with the following specifications and all as directed by Engr-in-Charge. (a) Size of the board should be 750 mm length, 600 mm width and 200 mm depth (b) 3 mm thick acrylic sheet of 750 mm length, 600 mm width should be provided for screen with adequate picture/letters on both side. (c) Main frame work will be done by 40x20x2 mm SS 316 angle in cuboid in shape. (d) The side of main frame should be covered with 3 mm thick acrylic sheet white in colour. (e) Foundation of structure should be 600 mm length and 800 mm height in PCC / Block Masonary with plaster finish with sutable ceramic tiles 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified. (f) 02 Nos High efficiency white colour LED light mount on 4 mm thick PVC sheet will be provided in each box including 15 mtr multi standard Copper conductor cable of 1.5 Sq mm 3 core size and internal wiring complete with HDPE/PVC conduit of size 25 mm dia. Including takingdown old unsv board. Note: 1. Conduit wall saddles & small excavation of cable, deemed to be included in the quoted rate.
vijay infraprojects pvt ltd
DWARKADHISH ENTERPRISE
RAJ ENTERPRISE
High Tech Consruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .