Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC KANNAMANGALAM VENGOOR THODUPUZHA NORTH PO KANNAMANGALAM KOTHAM KERALA | KOTHAM | KERALA | ₹18.9 L | L1 | Accepted-AOC L1 Accepted for further proceedings |
| 2 | L2₹19.1 LRejected-Finance ELAMPALLIL HOUSE ADINADU P O KADANGAMPALLY | KOTTAYAM | KERALA | 686542 | ₹19.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹19.2 LRejected-Finance ROOM NO 154 FIRST FLOOR PUDUKKALAI MULTI STORED INDUSTRIAL GALA KUNNAMKULAM ROAD POOKKUNNAM P O THRISSUR KERALA 680002 | THRISSUR | THRISSUR | KERALA | 680002 | ₹19.2 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | S.K.LIGHTS L2 | MERKURY ELECTRICAL CORPORATION L3 | Multiline venture L1 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS | ||||||
| 1.01 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 25.2 | cum | 362 ₹9,122.40 | 365 ₹9,198 | 359 ₹9,046.80 |
| 1.02 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 1.8 | cum | 7,937 ₹14,286.60 | 7,935 ₹14,283 | 7,932 ₹14,277.60 |
| 1.03 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete | 65.52 | sqm | 389 ₹25,487.28 | 393 ₹25,749.36 | 386 ₹25,290.72 |
| 1.04 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending , placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 500.71 | kilogra am | 118 ₹59,084.02 | 116 ₹58,082.59 | 112 ₹56,079.74 |
| 1.05 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 9.39 | cum | 10,497 ₹98,535.34 | 10,502 ₹98,582.27 | 10,488 ₹98,450.86 |
| 1.06 | 13.1.1 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand) | 17.32 | sqm | 381 ₹6,600.83 | 373 ₹6,462.23 | 369 ₹6,392.93 |
| 1.07 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 15.65 | cum | 320 ₹5,006.72 | 324 ₹5,069.30 | 318 ₹4,975.43 |
| 1.08 | OD141474/2025-2026 Fabrication, supply, conveyance & installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc | 4.03 | sqm | 13,699 ₹55,234.37 | 13,705 ₹55,258.56 | 13,693 ₹55,210.18 |
| 2.00ELECTRICAL WORKS | ||||||
Tender Value
₹18.9 L
EMD Value
₹47,249
Closing Date
10 Jan 2026, 5:00 pmClosed
Assistant Manager (PED)
STEEL INDUSTRIALS KERALA LTD.ATHANI P.O,THRISSUR- 680 581
S and I of 18 Nos.of 8 Mtr Mini Mast systems with 4 x 150W LED Flood Lights at various locations in Krishnapuram, Kandalloor, Bharanickavu and Pathiyoor GPs, Kayamkulam LAC, Alappuzha Dist under MLA-ADS 2025-26of Smt. U Prathibha Hari MLA
2026_SILK_825396_1
SILK/PED/S-191/2025-26/2326A
Open Tender
Miscellaneous Works
120 days
Pathiyoor
As per the tender documents
6 documents required · 6 mandatory
₹2,950
₹47,249
Yes
6 Apr 2026
3 Jan 2026
12 Jan 2026
3 Jan 2026
10 Jan 2026
3 Jan 2026
3 Jan 2026 - 10 Jan 2026
CIVIL WORKS
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending , placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
13.1.1 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD141474/2025-2026 Fabrication, supply, conveyance & installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc
ELECTRICAL WORKS
90.15.1.1 Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 64 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
OD146481/2025-2026 Installation, Testing and Commissioning of 150W LED Flood Light luminaire supplied by SILK. Contractor should take delivery of LED Flood Lights from SILK stores, and also carry out all necessary replacement works during the warranty period of 3 years at sites.
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/2.00 mm sheet
OD141479/2025-2026 Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a 25A/1.5HP capacity. It features 5 On/Off program settings for daily and weekly schedules, along with manual start, ON delay, and OFF delay settings. Equipped with a high-precision, industrial-grade chip and strong anti-interference capabilities, the timer can automatically turn on and off the power supply of various electrical equipment according to the time set by the user. The controlled objects can include street lights, light boxes, neon lights, and high/mini mast systems. It also includes a sufficient battery backup for time memory in case of power failure, and comes with suitable fittings for use in a distribution box or MV panel with FRLS PVC insulated .5 mm single core cable suitable for control wiring towards contactor
OD141480/2025-2026 Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hz operation. It can control street lights, light boxes, neon lights, high/mini mast systems, and induction loads.
OD141481/2025-2026 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 2.5 sq. mm
OD141477/2025-2026 Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MV panel. Specifications include: Voltage Protection Level (Up), Nominal Voltage: 230V, UOC: 10kV, L-N: 7kV, L-PE: 7kV, N-PE: 7kV, Nominal Discharge Current (8/20$\mus):10kA,TotalDischargeCurrent(8/20\mu$s): 60kA, Response Time: <35 ns, Ambient Temperature (Ta): -10 to 55°C.
OD141478/2025-2026 Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base.
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.3 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD141482/2025-2026 Supply and installation of 2.5 Sqmm non-insulated CP-1 pin terminals with suitable size heat shrink
90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
5.3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
OD141476/2025-2026 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
90.16.4.2 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20×3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for vertical run) 25×3 mm GI strip
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required3.15 mm copper conductor (10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.12.1.13 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35×75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm
90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
OD141475/2025-2026 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 6 sq. mm (19mm)
Lumsum Heading
Connection charges - KSEB
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
GCC.pdf
Tender Documents • 0.42 MB
PROFILE.pdf
Additional Documents • 0.03 MB
BOQ_1384106.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid