Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC JOGINDER NAGAR | ₹4.8 L Quoted ₹4.9 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹5.0 L+₹5,296.08 (1.08%)Rejected-AOC BASSI UNDER BASSI POWER HOUSE DIVISION HPSEBL JOGINDER NAGAR | UNA | HIMACHAL PRADESH | 174301 | ₹5.0 L+₹5,296.08 (1.08%) | L2 | Rejected-AOC Rejected Being a L2 |
| 3 | L3₹5.0 L+₹6,587.30 (1.34%)Rejected-AOC VILL KHUDDAR P O BASSI JOGINDER NAGAR DISTT MANDI H P | ₹5.0 L+₹6,587.30 (1.34%) | L3 | Rejected-AOC Rejected Being a L3 |
| Sl No | Description | Qty | Unit | Ram Chander Paul L1 | DHARAM VIR L3 | Ankit Thakur Contractor L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sq. metres and below. | 35 | Each | 125 ₹5,162.5 | 40 ₹1,652 Lowest | 150 ₹6,195 |
| 2.00 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below | 19 | Each | 125 ₹2,802.5 | 20 ₹448.4 Lowest | 150 ₹3,363 |
| 3.00 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood | 0.68 | Cum | 88,000 ₹71,026.56 | 59 ₹47.62 Lowest | 92,000 ₹74,255.04 |
| 4.00 | Providing and fixing panelled shutters for doors, windows and clarestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: - Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock/ Tuni Local wood 35 mm thick shutters. | 38.04 | Sqm | 2,500 ₹1,12,218 | 480 ₹21,545.86 Lowest | 2,600 ₹1,16,706.72 |
| 5.00 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws Kiln seasoned and chemically treated hollock/ Tuni Local wood 35 mm thick shutters | 50.18 | Sqm | 2,500 ₹1,48,031 Lowest | 2,500 ₹1,48,031 Lowest | 2,500 ₹1,48,031 Lowest |
| 6.00 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws Kiln seasoned and chemically treated hollock/ Tuni Local wood 30 mm thick shutters | 12.32 | Sqm | 2,500 ₹36,344 | 800 ₹11,630.08 Lowest | 2,625 ₹38,161.2 |
| 7.00 | Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710 | 22.42 | Sqm | 590 ₹15,608.8 | 400 ₹10,582.24 Lowest | 550 ₹14,550.58 |
| 8.00 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand :
6 graded stone aggregate 20mm nominal size). | 106 | Each | 50 ₹6,254 Lowest | 600 ₹75,048 | 50 ₹6,254 Lowest |
| 9.00 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 100x58x1.90 mm | 69 | Each | 100 ₹8,142 | 700 ₹56,994 | 90 ₹7,327.8 Lowest |
| 10.00 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm | 23 | Each | 150 ₹4,071 Lowest | 500 ₹13,570 | 175 ₹4,749.5 |
Tender Value
₹4.8 L
EMD Value
₹4,828
Closing Date
7 Aug 2026, 9:00 amClosed
Resident Engineer
Addl. Superintending Engineer,Bassi Power House Division, HPSEBL, Jogindernagar
Tender for Repair Replacement of wooden joinery in residential Colony Bassi under Bassi Power House Division HPSEBL Joginder Nagar
2026_HPSEB_140293_1
REB/DB-Tender(C)-04/2026-27
Open Tender
Civil Works
Item Rate
90 days
RE Office Bassi
As per BID documents
7 documents required · 7 mandatory
₹590
₹4,828
27 Aug 2026
31 Jul 2026
7 Aug 2026
31 Jul 2026
7 Aug 2026
31 Jul 2026
31 Jul 2026 - 7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sq. metres and below. | 35 | Each | - | - |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below | 19 | Each | - | - |
| 3 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood | - | Cum | - | - |
| 4 | Providing and fixing panelled shutters for doors, windows and clarestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: - Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock/ Tuni Local wood 35 mm thick shutters. | 38.04 | Sqm | - | - |
| 5 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws Kiln seasoned and chemically treated hollock/ Tuni Local wood 35 mm thick shutters | 50.18 | Sqm | - | - |
| 6 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws Kiln seasoned and chemically treated hollock/ Tuni Local wood 30 mm thick shutters | 12.32 | Sqm | - | - |
| 7 | Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710 | 22.42 | Sqm | - | - |
| 8 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand :
6 graded stone aggregate 20mm nominal size). | 106 | Each | - | - |
| 9 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 100x58x1.90 mm | 69 | Each | - | - |
| 10 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm | 23 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
ADDITIONALTERMSANDCONDITIONSC04.pdf
Additional Documents • 0.20 MB
BOQ_208089.xls
BOQ • 0.24 MB
TERMSANDCONDITIONSC04.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .