Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | L1 | Accepted-AOC due to lowest | |
| 2 | L2₹34.8 L+₹5.7 L (19.7%)Rejected-Finance PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | L2 | Rejected-Finance Rejected being not lowest. | |
| 3 | L3₹35.0 L+₹5.9 L (20.3%)Rejected-Finance MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L3 | Rejected-Finance Rejected being not lowest. |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
1 Oct 2019, 6:00 pmClosed
GE NW KOCHI
GARRISON ENGINEER NAVAL WORKS KOCHI MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI 682004
REPAIRS TO MP TILES, ROOFING SHEETS, EAVES BOARD, VALLEY GUTTER, WATER PROOFING TREATMENT, ROLLING SHUTTERS, HANGER, HINGES DOORS, ETC IN E, J AND D AREA UNDER AGE B AND R NO II OF GE NW KOCHI AT NAVAL BASE KOCHI
2019_MES_280350_1
GE(NW)/KOCHI/8229/E8
Open Tender
Civil Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE NW KOCHI
₹75,000
Yes
20 Jun 2020
6 Sept 2019
3 Oct 2019
6 Sept 2019
1 Oct 2019
19 Sept 2019
Amount
Dismantling single layer Mangalore pattern or similar tiles in roofing
Dismantling plain or corrugated steel sheeting any gauge, thickness complete in roofing.
Dismantling asbestos cement corrugated sheets in roof coverings.
Dismantling battens for tiles, shingles, etc of any size exceeding 15cm spacing including tilting fillets.
Dismantling timber boarding any description fixed in any position with nails.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/blankets, any thickness including cover fillets.
Dismantling timber scantlings 40 sq. cm and over in section, in any position unframed work and all as directed.
Dismantling timber scantlings under 40 sq. cm in section, in any position unframed work and all as directed.
S&F second class hard wood weather boarding, clean sawn, plain, 20mm thick or feather edged 20mm thick and fixed with 30mm laps as in soffits of gutter, eves board fixed with nails, etc. complete all as specified
All as per Item No. 9 here-in-before but fixing only (Materials obtained from dismantling shall be re-used after proper cleaning)
S&F 0.63mm thick glavanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type hook bolts and washers in roofs with grade of zinc coating 275 complete all as specified
All as per Item No. 11 here-in-before but except sheeting any thickness (Materials obtained from dismantling shall be re-used after proper cleaning)
S&F Plain Aluminium sheeting 0.71mm thick, Alloy 31000H4 in ridge, hips, valley gutter, drip and straight flashings.
S&F for pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F for pre-painted galvalume zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
M&L for 6mm thick asbestos cement corrugated or semi corrugated sheets fixed with, 'J' or 'L' type hooks as in roofs.
S&F AC two piece adjustable plain wing ridge 6mm thick fixed with 'J' or 'L' type hooks complete.
M&L for Mangalore pattern roof tiles interlocking at side joints laid dry.
All as per Item No. 18 here-in-before, but except tiles (Materials obtained from dismantling shall be re-used after proper cleaning)
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles bedded and jointed in CM 1:6.
All as per Item No. 20 here-in-before but except tiles (Materials obtained from dismantling shall be re-used after proper cleaning)
M&L second class hard wood scantling, clean sawn, 40 Sqcm and over in section, in unframed work complete all as specified
M&L for 2nd class hard wood clean sawn battern for tile at 30cm centres of sectional area exc 15Sqcm and n.exc 25Sqcm complete all as specified
All as per Item No. 23 here-in-before but fixing only (Materials obtained from dismantling shall be re-used after proper cleaning)
M&L for 4mm thick non asbestos fibre cement building boards fixed to timber or aluminium frame work with screws as in repairs.
M&L preparation of new surface and applying three coats of white wash on ceiling
M&L for lInd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails etc of sectional area exc 3 Sqcm and n.exc 6 Sqcm.
Taking down rainwater pipe, eaves gutter and AC vent pipe of any size including AC gutters, etc incl all fittings.
S&F PVC half round 150 mm dia. eaves gutter, heavy duty with complete fittings
M&L for PVC (SWR) junctions (Single 'T') equal or unequal to fit 150mm bore eves gutters, top portion half round and bottom portion to fit 110mm bore PVC pipes, etc complete.
S&F PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls 110mm bore all as specified
S&F PVC (SWR) bends any radius to fit 110mm bore pipe with access door all as specified
Dismantling structural steel work such as brackets for rain water pipe, gutter, etc.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified
S & F MS Plates (plain or chequered) for structural purpose, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W(Gde- E-250) quality- B all as specified
M & L structural steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as specified
S & F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular pipes or flat sections) including distance pieces, cleats etc conforming to Fe-410- W(Gde-E-250) quality- B complete all as specified
S&F Mild steel work in bands, straps, support for rainwater pipe, etc complete conforming to Fe-410-0 or Fe-310-0 all as specified
M & L for Preparation of steel surface of any description or 10cm width or girht and applying two coats of synthetic enamel paint over a coat of red oxide primer for new or old untreated surfaces complete all as specified
Preparation of old steel surface of any description or 10cm width or girht and applying two coats of synthetic enamel paint compete all as specified
M&L for repairing surfaces of wood and wood based surfaces, new or old of any description and girth and treated with one coat of creosote all as specified.
M & L applying two coats of cresote oil on new wooden surfaces of any description including preparation of surface complete all as specified
M&L for preparing and treating tiles battens any size and spacing with one coat of creosote complete all as specified. (Measured overall in one side only spacers not deducted) complete all as specified
M&L Preperation of new wood/wood based surface exc 10cm width/girth & apply painting two coats of synthetic enamel paint over a coat of pink primer complete all as specified
Taking down of existing roof treatment consisting of screed bed, plaster, tarfelts etc and removal of dismantled materials complete all as specified and directed
M & L for rendeing 15 mm thick on concrete/brick surfaces in CM 1: 4 finished even and smooth with out using extra cement including WPC as per manufacturers instrs (Note : WPC shall be measured and paid separately)
Supply only liquid Water Proofing compound, conforming to IS and as approved, complete all as specified.
M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manu-facturer's instructions, complete all as specified and as directed :-(a) Applying oil bound Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.25 Litre per Sqm.(b) Applying a layer of APP modified water proofing membrane; 4.0mm thick (minimum) weighing 4 Kg Per Sqm (reinforced with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre having softening point not less than 1400C longitudinal tensile strength not less than 800 N/Sqcm, tearing strength of 180N by torque application. The side overlaps shall be minimum 100mm and end overlap shall be minimum 150mm. (c) Applying one coat of blown grade hot bitumen 90/15 grade over the membrane @ 1.2 Kg/Sqm (d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane.
Demolition of brick work built in cement mortar, including all quoine, arches, pillar etc all as specified and directed by the Engr-in-Charge.
Taking down cement plaster of any description on brick or stone walls, ceiling including racking out joints, hacking for key, scrubbing down with water etc complete.
M&L for pre-cast cement concrete block masonry in Type C1, 1:3:6 (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified
M&L for 15mm thick plaster in CM 1;4 finished even and smooth without using extra cement complete all as specified
M & L for applying two coat of cement base paint over a coat of primer on plastered surfaces of walls includingpreparation of surface complete all as specified
M/s Antony Kallarakkal
Oriental Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .