| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr Quoted ₹2.4 Cr | L1 | Accepted-AOC Being L1 amongst the bidders |
| 2 | L2₹2.6 Cr+₹18.6 L (7.81%)Rejected-Finance | ₹2.6 Cr+₹18.6 L (7.81%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹2.6 Cr+₹26.2 L (11.0%)Rejected-Finance | ₹2.6 Cr+₹26.2 L (11.0%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹2.7 Cr+₹31.4 L (13.2%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹2.7 Cr+₹31.4 L (13.2%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹2.8 Cr+₹37.1 L (15.5%)Rejected-Finance | ₹2.8 Cr+₹37.1 L (15.5%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹3.3 Cr
EMD Value
₹4 L
Closing Date
5 Feb 2024, 6:00 pmClosed
SHRI SC NEGI CE HQ CE BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVISION OF ADDITION ALTERATION CUM SPECIAL REPAIR OF OFFICERS JCOS AND NCOS MD ACCN AT RAIWALA
2023_MES_632771_1
CEBZ/DDN(H)/T-17 of 2023-24
Open Tender
Civil Works
Item Rate
210 days
RAIWALA
AS PER NIT
8 documents required · 8 mandatory
₹2,000
Yes
AGE I RAIWALA
₹4 L
Yes
20 Apr 2024
14 Dec 2023
12 Feb 2024
14 Dec 2023
5 Feb 2024
20 Jan 2024
14 Dec 2023 - 21 Dec 2023
Amount
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items
Material and labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof padding over a one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be applied for bonding of new concrete/ mortar to old surface complete all as specified and directed. Note :- 1. Liquid water proofing compound will be measured and paid separately. 2. The work is required to be carried out at non-accessible roof for double storey The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. 3.Rate of SBR latex deemed to be included in the quoted rates of this item.
Material and labour for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying evenly a tack coat @ 1.2 kg/Sqm using 85/25 grade of industrial hot blown bitumen on primed surface of roof by applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.5 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : 1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land complete all as specified and directed
Material and labour for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with Liquied water proffing compound (as per manufactur direction ) complete all as specified and directed. Note :- water proofing compound will be measured and paid seperately..
Material and labour for Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications complete all as specified and directed. Note : Ponding test after water proofing coating will be done for ponding upto 48 Hrs and cost of the same shall be deemed to be included in the quoted rates.
Material and labour for 15 mm thick protection plaster CM 1:4 floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ) complete all as specified and directed Note :- The rates of SBR latex polymer shall be deemed to be included in quoted rates.
Material and labour for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or as as specified and directed.
Material and labour for cement concrete 1:5:10 type E2(using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.
Material and labour for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in floor mixed with Liquid water proofing compound complete all as specified and directed. Note :- WPC will be measured and paid seperately
BLANK
Supply only Liquid water profing compound of approved make complete all as specified and directed.
Dismantling of (salt glazed stone ware, AC or reinforced concrete) drain pipes up to 100mm dia , jointed in cement mortar and taking out of trenches if required .complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) bends of any radius
Supply and fixing 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
Supply and fixing 110 mm PVC (SWR) WC connector with lip ring complete all as specified and directed.
Supply and fixing PVC (SWR) reducers of size 110 mm x75 mm complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) P Trap complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement complete all as specified and directed.
Supply and fixing in repair stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe complete all as specified and directed.
Supply and fixing in repair stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 75 mm pipe complete all as specified and directed.
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas/RCC water tank and removal of debris and rubbish out side MoD land complete all as specified and directed.
Material and labour RCC 1:2:4 type B1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc.complete all as specified and directed.
Material and labour RCC 1:2:4 type B0 (using 12.50 mm graded aggregate) in Chajjas / fins/ facia for minor repair incl form work incl one coat of SBR latex as bonding of old concrete to new concrete complete all as specified and directed. Note : 1.The rates of SBR quoted shall deemed to be included for these items. 2. The work is required to be carried out at for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Material and labour for Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick, rough finished flat surface of concrete complete all as specified and directed.
Material and labour for precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
Material and labour for mild steel TMT bars 6mm to 8mm dia,for minor repairs as in RCC chajja, fin, facia, kitchen slab, incl welding, bending cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour for mild steel TMT bars10mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land) complete all as specified and directed.
Material and labour for cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position at an interval of not exc 2.0 metre complete all as specified and directed.
M & L for Plain Cement Concrete Type D2 1:4:8 (using 20 mm graded stone aggregate) in sub base of flooring/ hard standing /footpath complete all as specified and directed.
Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/disintegrated rock complete all as specified and directed.
Material and labour for Hard core of gauge n exc 63mm thick of broken boulder spread leveling watering ramming to true surface complete all as specified and directed.
Material and labour for P.C.C 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling , sub base of flooring/ hard standing. and mass concrete complete all as specified and as directed
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Material and labour for PCC type B1 1:2:4 using 20 mm graded aggregate in kerbs complete all as specified and directed.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each complete all as specified and directed.
Refixing of shutters in other opening of any descrption after easing and adjusting , n exc 1.00 Sqm complete all as specified and directed.
Refixing of shutters in other opening of any descrption after easing and adjusting , exc 1.00 Sqm but n exc 2.00 Sqm complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each complete all as specified and directed.
Providing and fixing factory made 35 mm thick 100% solid WPC window glazed shutter / wire mesh shutter 95 mm x35mm thick. Made from WPC material with density not less than 800 kg/cum. All four corner are fusion welded & screwed with 8 x 50mm self-screws for additional strength. After joining all 4 corner clear space to be paneled with 5mm thick glass / S S mosquito mesh after glazing of inside of shutter 10 x 12mm pvc “L” shape bead to be nailed or sticked with shutter. Provided 2 Nos SS hinges of 100 mm, 1 Nos S S handle of 125 mm ,2 Nos S S tower bolt of 125mm and 01 peg stay for each shutter (Glazed and Gauzed) incl factory made 100 % solid WPC window frame 125 mm x 65 mm double rebated frame & mullion 125 x 80mm. made from WPC (Single extruded process) material comparising of virgin PVC polymer of K value 57-60 (suspension grade), calcium carbonate and natural fibers (Wood powder/ rice husk/wheat husk) and nontoxic additives fabricated with meter joints after applying PVC solvent cement & screwed with fully body treated star headed screws having minimum frame desity not less than 800 kg / cum, having good screw holding capacity (screw withdrawal strength of (min 990N). Minimum compressive strength of 58 N/mm2. Modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / mosquito proof & fire retardant & fixed in position with fasteners / hold fast of required size. Window shall be provided with MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat including painting with countersunk holes at both vertical ends. Gap between the bars should not be more than 125mmcomplete all as specified and directed. Note - (i) Glazed and Gauzed shutter both are deemed in this quoted rate (ii) Glass pane, wire mesh and grill are deemed in this quoted rate
Material and labour for 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and directed .
M& L for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
Supply and fixing for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
Supply and fixing for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note- S S Butt hing measured and paid separately at relevant item
Plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 13 Sq.cm and not exceeding 25 Sq.cm, square, rectangular or triangular in section, wrought secured with nails complete all as specified and directed.
Supply and fixing Stainless steel barrel tower bolt of 300 mm length of extruded section complete all as specified and directed.
Supply and fixing Stainless steel barrel tower bolt of 300 mm length of extruded section and fixed in repair.
Supply and fixing Stainless steel barrel tower bolt of 200 mm length of extruded section complete all as specified and directed.
Supply and fixing Stainless steel barrel tower bolt of 200 mm length of extruded section and fixed in repair complete all as specified and directed.
Supply and fixing Stainless steel Handle 200 mm long, all as specified and directed .
Supply and fixing Stainless steel 200 mm long handle ,fixed in repairs, all as specified and directed.
Supply and fixing for stainlees steel sliding door bolt, of size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of stainlees steel complete all as specified and directed.
Supply and fixing for stainlees steel sliding door bolt, of size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of stainlees steel, fixed in repair complete all as specified and directed.
Supply and fixing 100 mm long Stainless steel Butt hinges complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm complete all as specified and directed.
Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples, fixed in repairs complete all as specified and directed.
Supply and fixing in repairs for stainless steel non magnetic curtain rod 20 mm dia with fixing brackets and decorative type knobs both side of each rod complete all as specified and directed. Note: - Measurement will be taken between end point of knobs”
Supply and fixing Aluminium door seal upto 1200 mm long on bottom of door complete all as specified and directed.
Supply and fixing 18 mm thick solid WPC board both side prelam for cabinet boxes & shutter , cup boards, drawer, etc with shelf and shutter incl lipping to edges of exposed surface incl provn of fixing arrangement complete all as specified and directed
Supply and fixing Continuous (Piano) hinges, stainless steel, bright finished or electro galvanized, width of flaps (When open) 30 mm complete all as specified and directed.
Supply and fixing SS Hat and coat hooks,solid body, 175mm to 250 mm complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
Material and labour for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) ,complete all as specified and directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
Material and labour for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for preparation of old surface of wall plastered including cornices and pillasters etc and applying two coat of white wash on ceiling complete all as specified and directed.
Material and labour for white washing three coats on ceiling incl preparation of newly plastered surfaces complete all as specified and directed.
Material and labour for Preparing new ceiling surfaces undecorated plastered or unpalstered/ perforated board surfaces and applying two coats of oil bound distempering over one coat of alkali resistant primer complete all as specified and directed.
Material and labour for Preparing old ceiling surfaces undecorated plastered or unpalstered/ perforated board surfaces and applying two coats of oil bound distempering over one coat of alkali resistant primer complete all as specified and directed.
Material and labour for Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately complete all as specified and directed.
Material and labour for Complete removal of existing treatment by mechanised system on walls internal or external surfaces in any height complete all as specified and directed.
Material and labour for preparation of new plastered or unplastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gMaterial and labouritre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Material and labour for preparation of old plastered or unplastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gMaterial and labouritre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed.
Material and labour for Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of new plastered or unplastered surfaces and applying two coat of distemper oil emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface complete all as specified and directed
Material and labour for preparation of old plastered or unplastered surfaces of walls and applying two coat of distemper emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
Roughening surfaces of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust, etc. to receive the screed layer for laying floor tile complete all as specified and directed.
Material and labour for coloured vitrified tiles of any design and pattern, 600x600x9 to 10mm thick, as in floor and skirting etc Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b with average water absorption between 0.08% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max Deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I)
Material and labour for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.18 sqm but not exe 0.36, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
Material and labour for Non- skid coloured ceramic tiles of any design and pattern, 300X300X 7 to 8mm thick, in floor etc Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
Material and labour screed bed or bedding layer of morter 15 mm thick cement plaster 1:6 for laying floor finished to receive floor tiles/granite complete all as specified and directed.
Material and labour for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mm thick, as in dado etc, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE (I)
Material and labour for rendering 10mm thick in cement plaster 1:4 on brick work or concrete surfaces surfaces or surfaces other than fair face of brick work to receive glazed tiles/granite complete all as specified and directed.
Material and labour for Machine cut pre polished kota stone slab flooring 18-20mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding and polishing complete all as specified and directed. Note:- (Screed bed shall be paid seperately)
Material and labour for 12 mm thick machine cut pre polished kota stone slab in riser of steps, skirting,dado and pillar laid over cement screed base laid and jointed with grewy cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding and polishing incl 10 mm thick Rendering 1:4 to recevie to kota stone complete all as specified and directed.
Material and labour for screed bed or bedding layer of morter 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelves etc.complete all as specified and directed.
Material and labour for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Material and labour for 18-20 mm thick pre polished udaipur green stone (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Dismantaling water tanks and removing to store exc 500 but not exc 1000 ltrs complete all as specified and directed.
Supply and fixing Rotational moulded polyethylene water storage tank 1000 liters capacity, white triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including all fittings complete all as specified and as directed.
Supply and fixing 20mm dia ball valve high pressure PTMT with epoxy coated aluminium rod & high pressure plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia complete all as specified and directed.
Ditto as per item 110 above but 20 mm dia .
Ditto as per item 110 above but 25 mm dia
Material and labour for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
Material and labour for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors complete all as specified and directed
Material and labour for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors complete all as specified and directed
Material and labour for Mild steel galvanized steel tubing of 25 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors complete all as specified and directed.
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
Supply and fixing 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs complete all as specified and directed.
Supply and fixing 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs complete all as specified and directed.
Supply and fixing in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply and fixing Towel Rail 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms) complete all as specified and directed.
Supply and fixing in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fixing in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
Supply and fixing Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
Supply and fix glass corner shelf fancy type made of 6 to 7 mm thick sheet glass of size 250mmx250mm fixed with chromium plated brackets complete all as specified and directed complete all as specified and directed.
Supply and fixing for PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
Supply and fixing in repair Wash basins (Padestal pattern) 550x400mm vitreous china (flat back type) incl cutting for and pinning in end of brackets for erecting stand but exclusive of waste pipe but including waste fitting complete all as specified and directed.
Supply and fixing for Grating ,cockroch proof, round 125 mm dia chromoum plated complete all as specified and directed.
Supply and fixing in repairs PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity complete all as specified and directed.
Supply and fixing in repairs Vitreous china Squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor complete all as specified and directed.
Supply and fixing in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all jointscomplete all as specified and directed.
Supply and fixing 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair complete all as specified and directed. (Make Jaquar Florentine FLR-CHR 5273UPR, Pearl GPR-884, Cera F1017401) complete all as specified and directed.
Supply and fixing 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe complete all as specified and directed. (Make Jaquar Florentine FLR-CHR 5273UPR, Pearl GPR-884, Cera F1017401)
Supply & fix in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed. (Make Jaquar Florentine FLR-CHR-5273 UPR, Pearl GPR-884, CERA-F1017401)
Supply & fix wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed. (Make Jaquar Florentine FLR-CHR-5273 UPR, Pearl GPR-884, CERA-F1017401)
Supply and fixing towel rack fixed with and including CP brass screws and wooden/plastic cleats,complete all as specified and directed.
Supply and fixing Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia all as specified
Supply and fixing in repair toilet paper holder chromium plated fixed to wall with chromium plated (CP) brass screws
Supply and fixing 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kgf per sqcm fixed to walls, ceilings or in floors etc. complete all as specified and directed.
Supply and fixing in repairs Sinks with drainage board made of stainless steel 0.8 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 and bowl size 410mm x 330 mm x 160mm complete all as specified and directed.
Supply and fixing Stainless steel kitchen plate rack 24 gauge thick sheet of over all size 31"x26"x10" fixed with steel screws and steel rawal plugs complete all as specified and directed.
Supply and fixing Expanded metal cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia., or fixing with steel staples to wood or steel members, weight not exceeding 4 Kg per Sqm complete all as specified and directed.
Supply and fixing Rolled mild steel work of Fe-290 (Gde E-165) as in framed work, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Material and labour for post construction Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. (Emulsion will be got ready as per manufacturer instructions)
Material and labour for post construction Anti termite treatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. (Emulsion will be got ready as per manufacturer instructions)
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation in hard/ dense soil and getting out complete all as specified and directed.
Demolition and breaking up drain pipes , 150 mm dia (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description & any position and not otherwise specifically provided for complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipe 150mm dia incl. packing under and haunching against the sides of pipe after the pipes are laid after the pipes are laid
Material and labour for 150 mm dia salt glazed stoneware drain pipes Grade A (ISI marked) laid in trenches and jointed complete all as specified and directed.
Returning filling in including spreading, levelling , watering and well ramming n exc. 25 cm in layers (Soil) soft / disintegrated rock complete all as specified and directed.
Removal of excavated surplus (soils) at a distance exc. 1.5 Km but n. exc 5.0 Km complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 100/150mm dia pipes complete all as specified and directed.
M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labour in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site complete all as specified and directed.
M & L for for shifting aside of MS monkey case of any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site complete all as specified and directed.
Supply and fixing of Heavy Duty telescopic channel of 20-22 inch complete all as specified and directed.
Supply and fixing to Auto closing hinges 35 mm of 0 crank ( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet & ward robe shutters complete in all respect and fixed in position complete all as specified and directed.
Material and labour for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed.
BLANK
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings etc built in cement mortar, incl providing fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard core, etc to store and rubbish not exc 50m complete all as specified and directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed .
Material and labour for Prepolished chequered cement concrete tiles 300X300X25 mm thick, rubber finished ,as in floors laid over 20 mm thick screed bed in cement mortar 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the tiles including removalof old materials from site not exceeding 100 meter, (ISI marked) complete all as specified and directed
Material and labour for Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Supply and fixing Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in complete all as specified and directed.
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. (Note: The taking down quantity as per old inventry handed over to contractor while building hand over.)
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.(Note: The taking down quantity as per old inventry handed over to contractor while building hand over.)
Dismantling and taking down old damaged existing DB’s of any type and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc. complete all as specified and directed.
Taking down old unserviceable wooden meter box of any size & any type from wall by disconnecting all electrical connections complete all as specified & directed
Taking down energy meter from wooden/steel meter box carefully and deposit to MES store yard complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed drawn in and including concealed PVC conduit, medium grade(ISI marked) ,(duly concealed on wall and open PVC conduit white colour on ceiling and above false ceiling with size not less than 20mm dia, the wires drawn inside PVC conduits should be as per IE rules the colour coding of Phase wire Red, Neutral wire black, Earth wirte Green, 1.5 Sqmm half circuit wire blue all as specified) Modular type sunk Metal flush box suitable for fixing modular fitting with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates
All as per item No 173 above but for one light point controlled by one no of one way switch single pole,, complete all as specified and directed.
All as per item No 173 above but for one ceiling fan point controlled by one no of one way switch single pole, complete all as specified and directed.
All as per item No 173 above but for one Exhaust fan point controlled by one no of one way switch single pole, complete all as specified and directed.
All as per item No 173 above but for one call bell point controlled by one no of bell push, complete all as specified and directed.
All as per Item No 173 above but for One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item no 173 but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no 173 above but controlled by two way point wiring with two Nos of 2 way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
All as per item No 173 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
All as per item No173 above but with 4.0 Sqmm PVC insulated FRLSH cable for AC point complete all as specified & directed.
Supply and fixing switch Modular single pole, one way 6 Amps , 1 module, ISI marked ,230 volts, 50 hz complete all as specified and directed by Engr-in-Charge. Make: IndoAsian Cat No: 800000/Legrand Cat No: 6734 01/Anchor cat No; 21011
Supply and fixing switch modular, one-way 16/20 Amps, 1 module 240 Volts, ISI marked complete all as specified and directed by Engr-in-Charge. Make: Indo Asian cat No: 800002/Legrand Cat No; 6734 11/Anchor Cat No; 21066
Supply and fix Modular Socket outlet, 6A - 3pin, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed by Engr-in-Charge. Make: Indo Asian cat No; 800020/Legrand cat No; 6734 52/Anchor Cat No: 21102
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, ISI marked, 50 hz complete all as specified and directed by Engr-in-Charge. Make: Indo Asian cat No: 800022/Legrand Cat No: 6734 55/Anchor cat No; 30828
Supply and fixing switch modular flush type single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed by Engr-in-Charge. Make: Indo Asian Cat No: 800001/ Legrand cat No: 6734 02/ Anchor Cat No: 21022
Supply and fixing bell push modular flush type single pole one way 6 Amps, 1 module with indicator, ISI marked complete all as specified & directed.
Supply and fixing step socket type modular fan regulator 120/280 V 2 module with indicator, ISI marked complete all as specified and directed.
Supply and fixing bell multi music type AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing ceiling rose, ISI marked, surface bakelite 65/25 mm dia complete all as specified & directed.
Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 440 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >100-120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed.
Supply and fix surface mounted LED luminiare, 10 watt 2 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed.
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing GI pipe of suitable length minimum 1.0 mtr and dia suitable for fixing of LED light, making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed .(All OfficerQtr inside building DB)
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar complete all as specified and directed
Supply and fixing MCB TPN 40 Amp 'B' series, 10 KA repturing capacity all as specified and directed.
Supply and fixing MCB SPN 32 Amp 'C' series, 10 KA repturing capacity all as specified and directed.
Supply and fixing MCB SP 6 to 25 Amp 'B' series 10 KA rupturing capacity complete all as specified & directed.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with one, double pole MCB 20 Amps 10 KA rupturing capacity 240 Volts AC complete all as specified & directed.
Supply and fixing fresh air fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air displacement -1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wall complete all as specified and directed.
Supply and fixing ventilation air fan AC single phase 230/240 Volt of size 250 mm sweep, non-metallic high quality engineering plastic, air delivery 680 cmm Power consumption- 36 W, RPM-1200 complete with louvers and two years warranty including making hole and grouting of nut bolts etc and making good the disturbed surfaces of wall complete all as specified and directed.
Supply and fix electric water heater,storage type ABS body with Glass lined stainless steel tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, 240 V, 50 Hz complete with all accessories such as safety valve, thermostate, NRV, Hot and cold water connection pipe all as specified and directed.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring for four single core 4 Sqmm PVC insulated unsheathed stranded copper conductor cable (FRLSH) 1100 volts graded drawn in for three phase and one for netural & including rigid PVC conduit 20 mm dia or more medium grade concealed in wall as per existing along with 4. Sqmm PVC insulated unsheathed copper conductor cable (FRLSH) as earth wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed. Note: Four runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size not less than 1200x800x450mm and maximum size suitable for fixing under metioned MCCBs, Pre paid meters, Multifunction meters 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following and size of panel suitable to fixing all below materials with required space as per IE rules:- .(a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings. ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three) INCOMING SUPPLY:- i) MCCB 100 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No.
OUTGOING SUPPLY:- i) MCCB 40 Amps, 415 Volts, 50Hz, rupturing capacity 16 KA = 4 Nos, (ii) MCB SPN 10 - 32 Amps 230 volts, 50 Hz, rupturing capaicty 10KA=2 Nos. iii) Space only for Smart Pre paid Electric Energy meter Three Phase AC 415 V, 10-60 Amps - 04 Nos & single phase smart pre paid energy meter AC 240V, 5-10 Amps -01 No iv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos Panel wiring for control circuit with copper flexible 6.0 Sqmm & power wiring minimum 6 Sqmm flexible . Notes:- 1. The panel manufacturer should have following certification:- i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore desing the panel . 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2 and maintaing space between MCCBs, MCBs, meters as per IE rules. 5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing.
6. Three phase/single phase smart pre paid energy meter rate should not be included on the quoted rate. The contractor should make space for fixing smart meter the meter will be fixed by department. 7. The required wall cutting if required and plastering, PCC work, necessary clamp for handing panel all are included in the quoted rate.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size not less than 1200x800x450mm and maximum size suitable for fixing under metioned MCCBs, Pre paid meters, Multifunction meters 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following and size of panel suitable to fixing all below materials with required space as per IE rules:- (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings.ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three) INCOMING SUPPLY:- i) MCCB 40 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No.
OUTGOING SUPPLY:- i) MCB SPN 25-32 Amps, 240 Volts, 50Hz, rupturing capacity 10 KA = 4 Nos, (ii) MCB SP 6-32 Amps 230 volts, 50 Hz, rupturing capaicty 10KA=2 Nos. iii) Space for Smart Pre paid Electric Energy meter single Phase AC 230 V, 10-32 Amps -04 Nos & Smart Pre paid energy meter 5-10 Amps -01 No iv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos. Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible . Notes:-1. The panel manufacturer should have following certification:-i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore desing the panel . 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2 and maintaing space between MCCBs, MCBs, meters as per IE rules. 5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing.
6. Three phase/single phase smart pre paid energy meter rate should not be included on the quoted rate. The contractor should make space for fixing smart meter the meter will be fixed by department. . 7. The required wall cutting if required and plastering, PCC work, necessary clamp for handing panel all are included in the quoted rate.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 4 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge.
Excavation in trenches in any type of soil and n. Exc 1.5 M wide and n exc 1.5 m in depth for poles, laying under ground HT cable, GI tubing (where provided for protection of cables), stay and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
M & L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note: Punned (consolidated) thickness of sand will be measured and paid.
Material and labour for cable protection with sub class ‘B’ bricks old size, laid dry, flat over sand cushining of cable, perpendicular across the cable in trenches complete all as specified and as directed.
M & L for cutting of road /hard standing as required at site, not exceeding 20 cm width and not exceeding 90 cm in depth for laying of cable protection pipe including insert the cable inside pipe making good the disturbed road/hard standing by providing PCC (1:2:4) Type B-1 up to the existing surface level and make good complete all as directed.
Supply and laying GI tube light grade 50 mm dia with all fittings laid in trenches or fixed on pole for protection of cable while fix on pole or HT pole structures pipe tightend with D type steel clamp, washers, nut, bolt etc.
Labour only for removing existing Geyser fitted on married Accn and keep in safe custody after repairing work of wall like plastering and painting Re-fixing the same geyser on position including providing new anchor fastner of suitable size and making connection with new hot & cold water connection pipe as per IS specified all as specified at site by Engineer in charge . Note :- The cost of connection pipe of hot & cold water are deemed to be included in the quoted rates . The T &P required to remove the geyser and Re-fixing the geyser included in quoted rate.
Supply and fixing brass chromium plated sink mixer for hot and cold water suitable for 15mm bore complete all as directed.
Supply and fixing 300mm mild steel ordinary rat tail rod patern springs, including roller and roller plate complete all as specified and directed.
Supply and fixing stainless steel handle 125 mm long complete all as specified and directed.
Note:- An amount of Rs 363160.80 will be deducted from the total quoted amount to arrive at the acceptance amount of the tender.
VEE SONS BUILDERS PVT LTD
M/s Ravindra Kumar Gupta & Sons
Sudhir Sharma Associates
SANJEEV CONSTRUCTIONS
M/S Mukesh Kumar Gupta
M/S Parshant Associates
imran construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .