Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹265.0 CrAccepted-AOC | ₹265.0 Cr Quoted ₹265.1 Cr | L1 | Accepted-AOC Accepted being reasonable and workable rates are quoted |
| 2 | L2₹268.4 CrRejected-Finance | ₹268.4 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹290.3 CrRejected-Finance NCC HOUSE MADHAPUR HYDERABAD 500081 TELANGANA INDIA TELEPHONE 040 23268730 | ₹290.3 Cr | L3 | Rejected-Finance Being L3 |
| 4 | L4₹294.9 CrRejected-Finance | ₹294.9 Cr | L4 | Rejected-Finance Being L4 |
| 5 | L5₹296.4 CrRejected-Finance CORE 3 SCOPE COMPLEX 7 INSTITUTIONAL AREA LODHI ROAD NEW DELHI 110003 | SOUTH | DELHI | 110003 | ₹296.4 Cr | L5 | Rejected-Finance Being L5 |
Tender Value
₹259.3 Cr
EMD Value
₹15 L
Closing Date
2 Sept 2023, 6:00 pmClosed
DDG and CE
DDG CE DGNP(V) Naval base post Visakhapatnam 530018
PROVISION OF MARRIED AND SINGLE ACCOMMODATION ALONG WITH RELATED FACILITIES AND SERVICES
2023_MES_609960_1
DDG CE V TOKEN 02 OF 2023-24
Open Tender
Civil Works
730 days
Rambilli
As per NIT
8 documents required · 8 mandatory
₹3,000
DGNP
₹15 L
Yes
DDG and CE conference hall
21 May 2024
20 Jul 2023
4 Sept 2023
20 Jul 2023
2 Sept 2023
11 Aug 2023
20 Jul 2023 - 5 Aug 2023
26 Jul 2023
Amount
Lump sum amount worked out by the contractor for "BUILDINGS & STRUCTURES" as listed in Schedule 'A' Part-I on Serial Page No. 47
Lump sum amount worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK EXCAVATION/HILL CUTTING" as listed in Schedule 'A' Part-II on Serial Page No. 51
Lump sum amount worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-III on Serial Page No. 53
Lump sum amount worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-IV on Serial Page No.57
Lump sum amount worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-V on Serial Page No. 58
Lump sum amount worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-VI on Serial Page No. 61
Lump sum amount worked out by the contractor for "ROAD /PATH/ CULVERT" as listed in Schedule 'A' Part-VII on Serial Page No. 65
Lump sum amount worked out by the contractor for "RETAINING WALL" as listed in Schedule 'A' Part-VIII on Serial Page No. 67
Lump sum amount worked out by the contractor for "AREA DRAINAGE" as listed in Schedule 'A' Part-IX on Serial Page No. 68
Lump sum amount worked out by the contractor for "COMPOUND WALL / GATE / FENCING" as listed in Schedule 'A' Part-X on Serial Page No. 71
Lump sum amount worked out by the contractor for " SKATING RING" as listed in Schedule 'A' Part-XI on Serial Page No. 72
Lump sum amount worked out by the contractor for "FIRE FIGHTING AND FIRE ALARM SYSTEM" as listed in Schedule 'A' Part-XII on Serial Page No. 76
Lump sum amount worked out by the contractor for " LIGHTNING PROTECTION" as listed in Schedule 'A' Part-XIII on Serial Page No. 77
Lump sum amount worked out by the contractor for "AC / HOT WATER / COOLING APPLIANCES" as listed in Schedule 'A' Part-XIV on Serial Page No. 78
Lumpsum price worked out by the contractor for "LIFTS", as listed in Schedule "A" Part –XV on Serial Page No. 80
Schedule "A" Part - XVI: [Miscellaneous Items] [Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Lightning Protection, Fire Fighting and Fire alarm System, Road, Skating Ring, HOT Crane, Air Conditioning, Hot Water, Cooling Appliance and Lifts]: [To be quoted by the bidder.]
M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS boxes, modular cover plates with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan point controlled by one way switch, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate.
Description all as per Serial Item No. 17 here in before but for light / fan point controlled by two twoway switches complete.
Description all as per Serial Item No. 17 here-in-before but with 2.5 Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 5Amp switch socket point, on independent board, complete all as specified.
Description all as per Serial Item No. 17 here-in-before but for 3 pin 5Amp switch socket point, on Same board, complete all as specified.
Description all as per Serial Item No. 17 here-in-before but with 4.0Sqmm copper conductor cable and 4.0 Sqmm cable as earth continuity conductor for 3 pin 5/15Amp switch socket point, on independent board, complete all as specified.
Description all as per Serial Item No. 17 here in before but for Bell / Buzzer point controlled by bell push complete.
Supply and fixing twin core copper telephone cable of size 0.5sqmm, PVC insulated PVC sheathed, complete all as specified.
S&F Telephone jack with shutter glossy white RJ 11 port with suitable gang box, complete all as specified and directed.
S&F Data socket white glossy RJ 45 and RJ 11 Port with suitable gang box and face, complete all as specified and directed.
S&F TV socket outlet, delux with suitable gang box, complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
All as per Serial Item No. 27 here in before but using galvanised iron strip 25 x 4mm earthing lead and 40mm bore GI pipe medium grade as protection pipe.
All as per Serial Item No. 27 here in before but using galvanised iron strip 32 x 6mm earthing lead and 50mm bore GI pipe medium grade as protection pipe. .
S&F LED Building Security light fitting 40Watts, 230 volts, >100lum/W, with Suitable size GI bracket made out of 25/40mm GI pipe fixed with clamps, nuts&bolts etc., complete with IP 65/66 protection with LED lamp, driver, bracket with impact and corrosion resistant and all accessories, complete all as specified and as directed. Make Cat. CIS-300-40-57-SL-DP-NGR for batten and LT8-20-865(2) for tube of Crompton or equivalent in makes given here-in-after.
S&F AC Three Phase Static Energy Electronic meter, flame retardant & temper proof box with transparent hinge, backlit LCD display with polycarbonate cover, 415Volt, 10- 60Amp, accuracy class-I, 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH with special features like TOD, temper logging, optical communication port disply in absence of power, complete all as specified.
S&F AC Single Phase Static Energy Electronic meter, flame retardant & temper proof box with transparent hinge, backlit LCD display with polycarbonate cover, 230Volt, 10- 40Amp, accuracy class-I, 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH with special features like TOD, temper logging, optical communication port disply in absence of power, complete all as specified.
Supply, install and testing of Refrigerator, electric driven (Single Phase), capacity more than 360 litres upto 460 liters, BEE 5 Star rated, double door, complete all as specified and as directed.
S&F Voltage stabilizer of capacity 2KVA, for automatic operation, suitable for deep freezers / refrigerator / water cooler / 2 Ton AC, single phase naturally air cooled indoor type and designed for input variation 170V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
S&F Voltage stabilizer of capacity 4KVA, for automatic operation, suitable for deep freezers / refrigerator / water cooler / 2 Ton AC, single phase naturally air cooled indoor type and designed for input variation 170V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
S&F Voltage stabilizer of capacity 5KVA, for automatic operation, suitable for deep freezers / refrigerator / water cooler / 2 Ton AC, single phase naturally air cooled indoor type and designed for input variation 170V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
S&F Meter board & enclosure box suitable for TPN 8 way enclosure & 07 Nos of Single /Three phase energy meters, fabricated with 2.00mm thick CRCA sheet with pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL 7035 coat with matt finish after due preparation of surfaces with and including aluminium alloy bus bar of suitable capacity, complete all as specified and as directed.
S&F AFFF type fire extinguishers - mechanical foam type 9 litres capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets, etc., complete all as specified.
S&F CO2 fire extinguishers - 4.5 Kg capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets etc confirming to IS : 15683 with ISI mark, complete all as specified.
S&F Dry chemical powder extinguishers, 9Kg capacity, complete with intial charge, gun metal cap, discharge hose with nozzle wall fixing brackets etc., confirming to IS : 15683 with ISI mark, complete all as specified and as directed.
Design, Supply, Install, testing and commissioning of Terrace pumping set, electrically driven, horizontal split case, centrifugal type conforming to IS and as per CPHEE manual with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings, suitable for continuous operation with range of operation 0% to 150% of rated capacity for 440V, 3 phase, 50Hz, 30mtr head, 900 LPM discharge, with and including DOL starter, single phase preventer, control switch gear MFM meter, with suitable foot valve with Y strainer with cored hole/slots and LT panel necessary MS frame and PCC foundation as per OEM Specification, GI sheet shed for weather protection, complete all as specified and as directed. Note: Contractor has to submit drawings for approval before manufacturing at factory and pump / motors shall be confirming to GRIHA 3 rating.
BLANK
Supply, laying, testing and commissioning of repeater alarm for fire detection and alarm system at security office through GSM/GPRS complete with necessary wiring, data transmission through LAN/GPRS along with SCADA software, communication through cloud, complete all as specified and as directed.
S&F GSM/PSTN auto dialler along with activated SIM, complete all as specified and as directed.
Supply, installation, testing and commissioning of 79 degree centigrade QBD, complete with required fittings, fire water sprinkler, Pendent type, temperature quick response, 3mm glass bulb coverage K-factor 5.6US (80 metric), material of construction high tensile brass forging, Test Pressure : 7PSI (0.50Bar), Working pressure : 175PSI (12Bar), Factory pressure: 500PSI (35 Bar), Bulb temp range and colour : 79 deg C /175 F orange, Brass / Nickel & Chrome plated finish, complete all as specified and as directed by Engineer-in-Charge.
BLANK
BLANK
S&F Cast Iron Air release valve suitable for 150mm bore, flanged of class PN 1.6, conform to IS, rubber lined, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
BLANK
Design, Supply, install, test and commissioning of Programmable logic control [PLC] panel for controlling 03 Nos of pumps with and including all its connected accessories, complete all as specified and as directed. Note: Contractor has to submit drawings for approval before manufacturing at factory and PLC panels shall be confirming to GRIHA 3 rating.
Supply, install, Retrofitting, test and commissioning of Flow switch for maximum service pressure 450PSI, 4-10GPM flow sensitivity, contact rating of Two Sets of SPDT (Form C) , NEMA 4 / IP 54 protection, 40 F - 120 F temperature range, non- corrosive sleeve factory installed in saddle, UL listed and FM approved, complete all as specified and as directed.
M&L for Valve chamber of size 1500mm x 1500mm x 1200mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces, complete all as specified and shown in TD drawing.
M&L for Valve chamber of size 450mm x 450mm x 700mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces, complete all as specified and shown in TD drawing.
Supply, install, test and commissioning of Deluge valve of size 100 NB, auto resetting type, model-A, for vertical inlet to horizontal outlet mounting, cast iron material flanged end to ANSI B16.1, Class 125, with trim 24Volt, solenoid valve, pressure gauges, pressure switch and 2Nos 100mm dia bore sluice valves, UL listed and FM approved, complete all as specified and as directed.
S&F Fire escape route map drawn on glow sign board / flex in required colour, letters and arrows at every 2m interval, for upto G+8 floor buildings, complete all as directed by Engineer- in- charge.
Supply, laying, testing and commissioning of Ductile Iron pressure pipe of 100mm bore with socket and spigot ends with blast furnace sludge cement with Portland cement properties suitable for push -on-jointing with inside cement mortor lining with internal metallic zinc coating and external black bitumen coating duly ISI marked, confirming to IS-8329:2000, class K-9, PN-10 rating, laid in trenches / floor, complete all as specified and as directed. Note: 1. Necessary earth work will be measured and paid separately. 2. Necessary fittings will be measured and paid separately.
M&L for DI Specials such as Bends , tapers any type, Tee pieces, single branch, "Y" junction, double branch, cross, collars, caps and plugs for connecting up to 600mm bore DI Pipe all as per IS:9523, complete all as specified and as directed. Note: Fittings shall be conforming to IS 9523:2000.
M&L for Earth Grid with GI strip of size 100mm x 10mm, including jointing by riveting/welding as required, laid in trenches / ducts, complete all as specified and as directed.
M&L for Earth Grid with GI strip of size 75mm x 10mm, including jointing by riveting/welding as required, laid in trenches / ducts, complete all as specified and as directed.
M&L for Earth Grid with GI strip of size 50mm x 10mm, including jointing by riveting/welding as required, laid in trenches / ducts, complete all as specified and as directed.
S&F Hot dip Galvanised perforated cable tray with cover for fixing XLPE cables at various places to accommodate the cables for MCBs, Panel etc of size not less than 300X150mm, 2mm thick with necessary bends, angles, supports for fixing etc., complete all as specified and as directed.
M&L for RCC (M25) Cable route indicator of size 800mm x 400mm x 75mm thick, minimum 500mm height above GL, duly painted with two coats of super enamel yellow colour over a coat of primer, duly marked with red colour words such as HT 11KV / LT Cable 1.1KV cables as directed with and including grouting in PCC 1:2:4 (Type B1), necessary earthwork, complete all as specified and directed.
RMU shall be provided with Mechanical Indicators for position ON-OFF-EARTH and Mimic Diagram at the front fascia of the RMU, Manometer with Remote Contacts and Two Numbers of Strip type Heater 230 Volts, AC, Single Phase, 80 Watts, Auxiliary PT 11 KV / 230 Volts, AC shall be provided in the BUS PT Panel, Manual Operating Handle, Operation, Installation and Commissioning Manual and tested for Internal Arc for 21 KA for 1 Sec with AFLR Classification. The Internal Arc Test 21 KA for 1 Sec shall be done for Main Tank and Cable Box both separately. The switch gear equipment shall be suitable for service on an electrical power system of 11 KV, 3 Phase, 50 Hz. They shall be of Single Bus Bar, Metal Clad, Floor Mounting type provided with integral earthing and testing‘s terminals. They shall be fully tropicalised and suitable for use at an ambient temperature of 40°C, Relative Humidity up to 100 %. The equipment shall be SF6 insulated and housed in a Cast Resin Module or Modules Hermetically Sealed for life at Atmospheric Pressure or at a pressure slightly higher than atmospheric pressure so as to minimize the risk of leakage. The ring main unit shall be totally safe for operation with fully fool proof interlocking system and provided with padlocks complete all as specified and as directed. Degree of Protection: [a] SF6 Tank: IP 67 [b] Front Cover: IP 2X [c] Cable Cover: IP 3X [d] Enclosure: IP 54 Impulse Withstand Voltage: [a] To earth and between Phases: 75kV [b] Insulation level: Power Frequency 1 Min: 28kV
Supply, Installing, testing and commissioning of OEM factory made, totally type tested panel confirming to IEC 61439 Part-1 & 2(IEC Type tested panel & Switch gear) confirming to IP 54 Protection, Free standing mounted on PCC pedestal, dust and vermin proof LT cubical panel board, compartmentalised, Indoor type, fabricated with 2.00mm thick CRCA sheet and shall be given pre-treatment for degreasing, phosphatising etc. In seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of high conductivity Aluminium Alloy bus bar TPN of rating 1.5times the incoming switchgear Amps capacity and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double compression aluminium cable glands and panel shall be provided with separate compartments for each switch, with gland plates lifting hooks, shutter type ventilating louver at top & bottom duly internally secured with wire mesh, suitable size, including instrumentation such as digital Ampere meter, digital Volt meter, Phase indicating lamps [RYB] etc with double stud hinged door, Operating handle & locking arrangement with back door common openable(screwed/Lockable) including interlocking with switch gears and suitable for 1100 volts Grade, 3 phase 4 wire with rated operational voltage 433V,50Hz, AC supply and to with stand short circuit fault level of not less than 100KA, rated insulation voltage of 1000V and Impulse withstand of 12kV and minimum internal Arc with-stand of 65kA, 500mSec as per IEC61641, weather proof.
Supply, Installation, testing & commissioning of fully type tested HT 11KV, 25 kA, Line VCB panels switchboard consisting of 2 Incoming 800Amps VCB and 1 NO 800Amp Buscoupler with 6 Nos 630Amp outgoing VCBs, VCB panel indoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated shall be used. The panel shall be of sheet steel construction with Aluminum Zinc not less than 2.5mm thickness for load bearing section and not less than 2mm thickness for non-load bearing, totally dust and vermin proof, confirming to IEC 62271-100 & IEC 62271-200 standards and IP 4X class of protection, comprising necessary bus-bars extension & connections with following protective & control devices:- Circuit Breaker suitable for E2, M2, C2 duty, Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the Vacuum Interrupter, Relay. Panels shall be with temperature measurement sensors at all critical points Medium voltage cable connection & Busbar joints/ Connections for local investigation and local monitoring. HMI shall be provided for condition monitoring data and alarms as per Specifications. The switchgear and control gear panels shall be of the fully arc proof for 25kA for 1 Sec., complete with the following accessories:- (A) Relay shall be Microprocessor based Numerical Relay Communicable type in line with IEC 61850 Protocol and RS-485 port comprising of three over current, one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxiliary supply, Master Trip Relay, Trip Circuit Supervision relay, Digital MFM and RS-485 port with Class 0.5 with copper wound double ratio double core Current Transformer, MFM 0.2 class. Note: Incoming shall be with PT, Transfomer Outgoing shall be Differential relay & Annunciator.
(B) Relay Specifications:- (a) MIMIC display with single line representation and switch gear controls shall be possible through the MIMIC. (b) The device shall support following communication protocols: Native IEC 61850, IEC 60870-5-101, IEC 60870-5-103, Modbus TCP, Modbus RTU, DNP 3.0, SPA-bus communication, (c) Relay shall have front USB for connecting to PC. (d) Relay shall have conformal coating to withstand harsh environment. (e) Relay shall support PRP/RSTP redundancy communication protocol on RJ45/ FO. (f) Relay shall have web server (web HMI) feature to monitor and control using LAN. (g) Relay shall have minimum 2000 events. (h) Relay shall support SNTP time synchronization. (i) Relay shall support customer defined programmable logic. (j) Relay shall have minimum 8 programmable LED. (k) Relay shall have disturbance recorder with settable sample rate from 32/cycle up to 1per minute and shall support virtual simulation through which protection functions and logic testing can be achieved without any separate software. (l) Phase overcurrent (50/51), Directional phase overcurrent (67),SOTF Switch on to fault (50 HS),Current unbalance (46),Thermal overload (49),Earth fault (50N/51N),Directional earth fault (67N), Undervoltage (27),Overvoltage (59), Zero sequence voltage protection (59N), Frequency (81), directional power (32), auto reclose (79), Circuit breaker failure (50BF),Cold load pick-up and magnetizing inrush, Programmable stages (99),Synchro check (25),CB wear. (m) The relay shall have 4CT and 4 VT inputs. (n) The relay shall be provided with at least 16 digital inputs and 8 digital out puts and 1 self-supervision output.
(o) Including connections and accessories suitable for 3core x 400Sqmm 1KV Cable with led indicators as per OEM recommendation and Complete intra and inter panel wiring including multi stranded multi core copper control wiring for connecting all the MFMs and all the accessories, LED indicators and equipment's etc., as per OEMs recommendation is deemed to be included in the unit rate quoted and along with any other accessory to make the 11kV panel functional. (p) Drawings Shall be Approved by PGCIL.
S&F Fully automatic transfer Change over switch with RJ 45 ethernet connect port along with cable integrated with SCADA for source change, cubical type with arc chute of capacity 800Amps, range 63A to 800A, AC 23A, 4P conforms to latest IS/IEC codes with inter chargeable dual shaft position with site convertibility and flip-able handle able 800A capacity in LT panel, including necessary interconnections of cables and control wiring, complete all as specified and as directed.
S&F Fully automatic transfer Change over switch with RJ 45 ethernet connect port along with cable integrated with SCADA for source change, cubical type with arc chute of capacity 630Amps, range 63A to 630A, AC 23A, 4P conforms to latest IS/IEC codes with inter chargeable dual shaft position with site convertibility and flip-able handle able 630A capacity in LT panel, including necessary interconnections of cables and control wiring, complete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 450KVAR with 08 steps capacitor banks (100KVARx2Nos+50KVARx4Nos + 25KVARx2Nos) with 100A ACTIVE HARMONIC FILTER which shall be expandable upto 200A AHF rating for future expansion purpose, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 1000KVAR with 15 steps capacitor banks (100KVARx7Nos+50KVARx4Nos + 25KVARx4Nos) with 160A ACTIVE HARMONIC FILTER which shall be expandable upto 200A AHF rating for future expansion purpose, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Supply, Installation, testing & commissioning of copper wound step down Transformer, indoor type complete with standard fittings, 3Phase, 2000KVA, 11/0.433KV, Dyn 11", OCTC (+7.5% to -7.5%@ 2.5%) Natural Ester Oil cooled transformers, temp rise, Impedance and losses shall conform to IS 1180- level III, radiators shall be Hot dip galvanized (HDG) to avoid corrosion. HV Cable Box and LV Cable Box as per Specifications, with and including Civil Foundation as per OEM recommendations, complete all as specified and as directed. Notes: (i) Drawings Shall be Approved by PGCIL. (ii) Foundation shall be as per manufacturers recommendation. (iii) The two winding power transformer shall be nature oil immersed conform to IS-1180, Level-III and IEC-62770 standard for nature ester oil filled transformer. The equipment shall confirming to latest applicable standards as follows: a) IS:2026 for tests and tolerance on guaranteed particulars. (b) IS: 1180 for Losses and Impedance. (c) IS:3639 for fittings and accessories (d) IS : 2099 for brushing > 1000V (e) IS:7421 for bushing <1000V. (f) IS:1271 for electrical insulation classified by thermal stability.
Supply, Installation, testing & commissioning of copper wound step down Transformer, outdoor type complete with standard fittings, 3Phase, 1000KVA, 11/0.433KV, Dyn 11", OCTC (+7.5% to -7.5%@ 2.5%) Natural Ester Oil cooled transformers, temp rise, Impedance and losses shall conform to IS 1180- level III, radiators shall be Hot dip galvanized (HDG) to avoid corrosion. HV Cable Box and LV Cable Box as per Specifications, with and including Civil Foundation as per OEM recommendations, complete all as specified and as directed. Notes: (i) Drawings Shall be Approved by PGCIL. (ii) Foundation shall be as per manufacturers recommendation. (iii) The two winding power transformer shall be nature oil immersed conform to IS-1180, Level-III and IEC-62770 standard for nature ester oil filled transformer. The equipment shall confirming to latest applicable standards as follows: a) IS:2026 for tests and tolerance on guaranteed particulars. (b) IS: 1180 for Losses and Impedance. (c) IS:3639 for fittings and accessories (d) IS : 2099 for brushing > 1000V (e) IS:7421 for bushing <1000V. (f) IS:1271 for electrical insulation classified by thermal stability.
M&L for Supply, erection, testing and commissioning of double girder HOT crane with span 6.0mtrs (Apx) having 3Ton capacity and lifting height 7.0mtrs from floor level, long travel of length 18.0mtrs with phosperous bronze cladding wheels, grade 80 load chain & zinc plated hand chain, non-ferrous parts like chain wheels, chain guides, ratchet wheel and stripping fork, double girder hand operated chain, cross travelling trolley complete with ISMC girder rails, chain pulley block, confirming to IS:807, IS: 3177 and IS: 3822 or latest IS, complete all as specified and as directed. Note: (i) Span and Long travel may vary slightly as per site condition.
Supply, Installation, testing & commissioning of Silent Diesel Engine driven generating set, prime mover with electronic governing 415Volt (at 0.8 PF) 500KVA, 3 phase, 50 Hz, 1500RPM with acrostic enclosure and canopy type (indoor use) made out of min 14 gauge CRCA sheet with AMF Panel with and including all excavation, PCC foundation (as per manufacturers recommendation's), anti vibration pads, tamper standard control panel as per manufacture instructions, The DG set will comprise of following: -(a) Alternator: Standard design alternator rated at 500KVA net out put at site, self excited, self regulated through an AVR, screen protected, revolving field, brushless design with permanent lubricated bearings with winding in each pole, insulation class H, voltage regulation ± 1.5 % of rated voltage 'No load to full load'. The alternator shall be in a position to generate supply with frequency regulation within ± 1 % tolerance and permissible overload of 10 % for one hour in 12 hrs continuous run and conforming to IS 13364 with latest amendments. (b) Diesel Engine adequate capacity suitable for 200 KVA Alternator water cooled to dirve indpependently the above alternator directly coupled through flexble coupling multi cylinder Multi stroke direct injection cold strating 1500RPM as per revant IS, IS:10001/ 10002 BS 5514 with in overload capacity of 12 hrs continious running, with standard accessories all as specified and required for site handling and operation, the scope of accessories shall be as under :- (i) Air intake system : air intake manifold air cleaner. (ii) Exhaust system : Turbo charger SS Flexible below silencer complete with MS exhaust piping of suitable size upto and outside the building covered with glass wool covered under aluminium foil of 28 gauge, adequate to exhaust without transferring vibration to building/walls as per latest CPCB Norms. (iii) Coolant system : Engine water pump, radiator with fan and fan belt. (iv) Lubricting system Oil pump of suitable capacity, lub oil pump and lub oil filter.
(v) Fuel system : Fuel injection pump 12/24 Volts (as per OEM recommendation) DC solonoid switch nozzle mechanical/electronic governor, replaceable fuel filter, fuel tank made of 14 SWG sheet with drain valve, air vent inlet and outlet connection, fuel supply piping from tank to pump & to engine including return of over flow fuel with level indicating arrangement duly marked in inches/Litres. Fuel tank should be of adequate capacity for 8 hrs running at full load. (c) Starting system: 12/24V DC self starter 12/24V DC battery charging alternator, start & stop push button, ignitor key/ switch, Battery of reputed make of suitable capacity in changed condition with its copper leads of adequate size as per OEM recommendations. (d) Base frame: common base plate with AVM pads for mounting the engine & alternator. (e) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key,(ii) Water temperature indication,(iii) Lubrication oil pressure indication,(iv) Lubrication oil temperature indication,(v) Battery charging indication,(vi) RPM indication,(vii) Over speed indication,(viii) Low lub. Oil trip indication & (ix) Engine Hours indication (f) Saftey control : Lub oil pressure trip, High water temp trip & over speed trip. (g) Acoustic enclosure: Modular construction with the provision to assemble & dismantle easily at site, powder coated & stainless steel nut & bolts/external hardware, provision for filling fuel from outside the enclosure with locking arrangement, Sound proofing of enclosure with high quality rock wool /mineral wool The rock wool is further covered with fibre glass tissue & perforated sheet . A special residential silencer within the enclosure to reduce exhaust noise. Noise level 75 db (A) at 3 m distance.
All as per Serial Item No. 86 here in before but for 320KVA capacity DG Set with alternator at 320KVA net output at site and capacity of diesel engine shall be adequate for 320KVA alternator, complete all as specified.
S&F Wall mounted fan 400mm sweep, osculation type of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable clamp, flexible cable suitable for 230volt, AC 50 Hz, complete all as specified and as directed.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with and including HDPE pipe of 150mm dia suitable for 6 KGF/Sq.cm working pressure, complete all as specified and as directed.
S&F CAT 6 Ethernet cable, 6core RJ 45, complete all as directed by Engineer-in-Charge.
S&F LED bulb 1x8w, 220volt, P.F>0.95 with and including lamp holder PVC/polycarbonate type with cord grip cap suitable for LED lamp, complete all as directed by Engr-in-charge.
S&F Air Circulator fan 450mm sweep osculation type of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable clamp, flexible cable suitable for 230volt, AC 50 HZ, complete all as specified and as directed.
S&F Air Circulator fan 600mm sweep osculation type of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable clamp, flexible cable suitable for 230volt, AC 50 HZ, complete all as specified and as directed.
S&F Energy saving, environmentally friendly & robust High bay light LED 80 Watt energy efficient, P.F>0.95, >100 lum/watt, with and including LED light driver holder connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. Make: Cat No. LHELAAU7PG7S080 of Havells or Equivalent in makes given here-in-after.
S&F Decorative luminary suspended type mounting 30/35 watt, 220Volt, P.F>0.95, >100 lum/watt, complete with 30/35 watt, lamp holder, complete made up of polycarbonate, connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. Make Cat. BLRL 35CDMT 35W of Bajaj or equivalent in in makes given here-in-after.
S&F Cast Iron Air release valve suitable for 150mm bore, flanged of class PN 1.6, rubber lined, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F Cast Iron Air release valve suitable for 50mm bore, flanged of class PN 1.6, rubber lined, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F 15mm dia 2 in 1 Bib cock, fancy type, twin elbow valve faucet wall mounted type, with and including SS health faucet & jet spray with SS flexible tube & hook, complete all as specified and as directed. Make: Cat No. F-330004 for Bib cock and F-160023 for Health Faucet of Hindware or equivalent in makes given here-in-after.
M&L for Thermoplastic road making paint as per MORT&H specification, not exceeding 10cm wide with hot thermo plast material @5kg/Sqm of white / yellow confirming to BS-3262-1989, by fully automatic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by skilled operator, including preparation of surface, complete all as specified and as directed.
SCHEDULE 'A' PART-XVII [PHASE -III]: OUTSOURCING SERVICES FOR MANNING & OPERATION LIFTS DURING FIRST YEAR OF DEFECTS LIABILITY PERIOD:- Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-XV, during 1st year of defects liability period, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
SCHEDULE 'A' PART - XVIII [PHASE -IV]: OUTSOURCING SERVICES FOR MANNING & OPERATION LIFTS DURING SECOND YEAR OF DEFECTS LIABILITY PERIOD: Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-XV, during 2nd of defects liability period, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-XV, during 1st year after expiry of defects liability period, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-XV, during 2nd year after expiry of defects liability period and After completion of first year Comprehensive Maintenance, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-XV, during 3rd year after expiry of defects liability period and After completion of 2nd year Comprehensive Maintenance, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
RKEC Projects Limited
NCC LIMITED
Rds Project ltd.
Engineering Projects India Ltd
RVR PROJECTS PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid