Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.1 L+₹1.7 L (11.6%)Rejected-AOC C O GIVEN GOD NONGTDAU ARBUTHNOT ROAD NONGRIMMAW LAITUMKHRAH SHILLONG PIN 793011 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793011 | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.4 L+₹3.0 L (21.1%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
25 Mar 2021, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015 Tele 0361 2841626
SPECIAL REPAIR TO BLDG NO T176 FOR LLTR OPS AT AFS KUMBHIRGRAM
2021_MES_425620_1
CWE (AF)/KUM/TOKEN-50 OF 2020-21
Open Tender
Miscellaneous Works
Works
180 days
Kumbhirgram
As per tender documents
8 documents required · 8 mandatory
₹500
AGE I AF Kumbhirgram
₹38,000
28 Apr 2021
25 Feb 2021
27 Mar 2021
25 Feb 2021
25 Mar 2021
11 Mar 2021
Amount
B/R Works:- Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as specified and directed.
S&F interlocking aluminium power coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and directed.
M&L for Non Asbestos fibre cement building boards 4 mm thick fixed or laid in aluminium frame work with screws as in ceiling complete all as specified and as directed
Dismantling unframed timber scantling 40Sqcm and over in section in any position complete all as directed.
M&L second class hard wood in scantlings clean sawn timber framed work fixed with nails complete all as specified and directed.
Demolition of plain cement concrete (Un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials to a distance not exceeding 50m and depositing complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section complete all as specified and directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed.
M&L for non skid ceramic joint free coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 20 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
S&F for glazed ceramic coloured/printed tiles of size 300x200x6 to 7 mm thick as in vertical surfaces such as skirting, dados fixed over and including 10 mm thick cement plaster in cement mortar (1: 4) complete all as specified and directed.
Taking down shutter of any description exc 2 sqm each and removing away all as directed.
Taking down shutter of any description not exceeding 1 sqm each and removing away all as directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gaug, etc.( without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc. (with sash bars) with plain, chamfered or rounded, mitredand rebated sash bars, any numbers for securing glass etc, sizes of members of shutters as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50sqm in each pane complete all as specified and directed.
S&F galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
S&F second class hard wood small fittings such as brackets of any type, latch and hinge blocks shaped door and window stops and the like including all necessary labours, articles not exceeding 200 Cucm each complete all as specified and directed.
Supply only PVC low level flushing cistern, White, 10 ltrs capacity, valveless, syphonic action type including all fittings and flush pipe, PVC connection pipe all as specified and directed.
S&F in repair vitreous china squatting pan “Orissa pattern of size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including lime concrete bedding complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white, flat back of size 550x400mm including cast iron brackets, waste coupling, PVC waste pipe complete all as specified and directed.
Supply only 15mm bore pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes type 'B', single socketed in any length with rubber ring joints and laid in trenches or in floor as in waste/soil pipe complete all as specified and directed.
M&L for complete removal of existing treatment oN walls including brooming down , applying two coats of oil emulsion distemper over and including one coat of cement primer and 1mm thick wall care putty on wall complete all as specified and directed .
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, not otherwise described, not exceeding 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed.
Taking up or down 15 mm bore GI tubing and connections including cleaning for re-fixing or removal to store complete all as directed.
Fixing only old serviceable GI tubing 15 mm bore, medium grade with all new fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F GI tubing 15 mm bore, medium grade with all fittings such as bends, elbows, nipples, sockets, tees, unions, short pieces etc. and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Taking up or down 20 mm bore GI tubing and connections including cleaning for re-fixing or removal to store complete all as directed.
Fixing only old serviceable GI tubing 20 mm bore, medium grade with all new fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F GI tubing 20 mm bore, medium grade with all fittings such as bends, elbows, nipples, sockets, tees, unions, short pieces etc.and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Taking down aluminium chowkats or frames with shutters exceeding 1.5 SQM but not exceeding 4 SQM in each and removing away complete all as directed.
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and as directed.
M&L for anodized aluminium push pull type partly paneled and partly glazed door shutter having top rail of section 85.00mmx44.45mmx2.00mm, bottom rail of section 85.00mmx44.45mmx2.00mm thick, door verticals of section 44.45mmx44.45mmx2.00mm thick and lock rail of section 85.00mmx44.45mmx2.00mm thick with aluminium anodized chowkats of section 63.50mmx33.10mmx2.50mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle and brass mortice lock 4 lever etc. fitted with 12mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.5 mm thick clear / frosted glass as required on top panel complete all as specified and as directed.
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays, hinges , suitable handle and 4.0 mm thick clear / frosted glass as required complete all as specified and directed.
S&F PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of aluminium/ GI/ MS as per specification and manufacturers instruction complete all as specified and directed.
M&L 75mm thick plain cement concrete (1:2:4) type B2 using 40mm graded crushed stone aggregate as in plinth protection, finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L plain cement concrete (1:2:4) type B1 using 20mm graded crushed stone aggregate as in surface channel and drain including necessary form work complete all as specified and directed.
Material and labour for preparation of old painted wooden surfaces of any description, not otherwise described for, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described for, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treating with two coats of creosote oil complete all as specified and directed.
Dismantling boarding, any description, fixed in any position complete all as specified and directed.
S&F PVC Eaves board 250 mm width , 18 mm thick, jointing with solvent cement and fixed with stainless steel screw complete all as specified and directed.
M&L for solid PVC Wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
S&F stop valve 15 mm dia cast copper alloy chromium plated with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
S&F PVC waste pipe of size 32 mm dia and 90 cm long for WHB/ urinal complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
E/M WORKS Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, complete all as directed.
Materials and labour for point wiring with 1.50 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping not less than 20 mm width and 1.2 mm thick complete with all fittings and accessories, fixed to walls/ceiling, including factory made PVC rectangular switch board with plastic laminated sheet cover for mounting switches/ sockets/regulator etc including 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One light point/ One fan point/bell point controlled by one switch complete all as specified and directed.
All as per item No 51 here-in before but for one 3 pin, 5 Amp socket point on independent board complete all as specified and directed.
All as per item No 51 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed.
All as per item No 51 here-in before but for one 3/5 pin, 16 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed.
M&L for sub main wiring with 2 runs (Phase Neutral) of single core 6.0 sqmm (Nominal area) stranded FR PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including PVC casing capping not less than 25mm width including 1 x 4.0 sqmm (Nominal area) FR PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. (Note: Two runs of 6.0 sqmm cable and one run of 4.0 sqmm earth continuity conductor including PVC casing capping with plastic terminal boxes shall be measured as one run length).
M&L for sub main wiring with 2 runs (Phase Neutral) of single core 4.0 sqmm (Nominal area) stranded FR PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including PVC casing capping not less than 25mm width including 1 x 2.5 sqmm (Nominal area) FR PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. (Note: Two runs of 4.0 sqmm cable and one run of 2.5 sqmm earth continuity conductor including PVC casing capping with plastic terminal boxes shall be measured as one run length).
S&F LED batten tube light fittings , 20 W with high quality extruded aluminium housing & integrated LED driver with decorative end caps with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F LED batten tube light fittings , 10 W with high quality extruded aluminium housing & integrated LED driver with decorative end caps with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F recessed mounted LED luminaire 36 W (2'x2') suitable for grid ceiling with white powder coated CRCA housing & super bright LEDs, seamless front frame with flat white high transmission acrylic cover with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Fixing only serviceable LED light fittings of any type and watt on wall or ceiling and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. (Serviceable light fittings obtained from taking down of point wiring shall be reused)
S&F stepped type electronic fan regulator flush type AC, 230V complete all as specified and directed.
S&F ceiling rose, surface bakelite 65 x50 mm three terminals, complete all as specified & directed.
S&F switch piano flush type single pole one way 5 amps, 230 V complete all as specified and directed.
S & F switch socket combination 2 in1, 3 pin 5 Amp flush type complete all as specified and directed.
S & F switch socket combination 2 in1, 3 pin 5 and 15 Amp flush type complete all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as directed.
S&F MCB DP, 415 Volts, 'C' series, breaking capacity 10 KA of rating 32 Amps complete all as directed.
S&F MCB DB , SPN 8 way, double door with 200 Amp rated bus bar including earth and neutral link ,complete with fixing accessories all as specified and directed.
S&F MCB DB , SPN 4 way, double door with 200 Amp rated bus bar including earth and neutral link ,complete with fixing accessories all as specified and directed.
M/s J. C. CONSTRUCTION
Shri Jyotibrata Chakrobarty
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .