| 1 | L1₹22.7 LAccepted-AOC H NO 1 77 1 VIJAYANAGARAM COLONY KONDAIEGUDEM POST MANUGURU 507117 BHADRADRI KOTTAGUDEM DIST TELANGANA STATE | BHADRADRI KOTHAGUDEM | TELANGANA | 507117 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | Not Admitted-Fee/PreQual/Technical H NO 3 79 ASWAPURAM ASWAPURAM M BHADRADRI KOTHAGUDEM DIST TELANGANA STATE 507116 | BHADRADRI KOTHAGUDEM | TELANGANA | 507116 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹23.1 L
EMD Value
₹46,240
Closing Date
17 Jul 2024, 6:45 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager, HWP(M)
General Manager, HWP(M)
Maintenance of Electrical Equipments related to TG#1,2,3,4, SG#1,2,3 areas, DFACS, DM Plant, FOPH areas of CPP, HWP(M) and other miscellaneous works.
2024_HWB_813073_1
HWPM/E-U/GR-II/TG-BG/2024/NIT
Open Tender
Electrical Works
Item Rate
547 days
CPP, HWP(M). Works
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹46,240
8 Nov 2024
24 Jun 2024
24 Jul 2024
24 Jun 2024
17 Jul 2024
24 Jun 2024
24 Jun 2024 - 28 Jun 2024
Amount
Dust out the Coal powder/ Ash powder on the HT & LT (VFD) motors in boiler Area including cleaning of oil leaks on the motors with suitable brush & Cleaning the cooling Tubes / Fins (or) Suction Grills of HT & LT(VFD) motors with the available cleaning pipe for any chocking of the cooling tubes.
Upkeeping & maintenance (Cleaning) of the LT motors in SG area from dust, oil with suitable brush & Tighten of Earth leads etc
Upkeeping and maintenance (Cleaning) of the LT motors at FOPH, DM Plant areas from dust, oil with suitable brush & tighten of earth leads etc.
Dedusting of 415V MCC/SwitchGear with air completely including bus bar joints, incoming and out going terminals tightening, lugging and recrimping of loose cable lugs. Note:Department will issue contact cleaner at free of cost.
Preventive Maintenance ie., HV/LV bushing cleaning and terminals tightening of ESP field Rectifomers and 6.6 KV /415 V CPP distribution transformers including TB and IR values checking. Note: Department will issue contact cleaner at free of cost.
Cleaning of insulators of ESP Rectiformers in roof beam and Tightening connections. Earth switch Connections of pin insulator is also to be checked & tightened. Note: Required Cotton Waste for cleaning will be issued by Department at free of cost.
Maintenance (TB checking) of HT & LT(VFD) motors including terminals cleaning, Earth & RTD connections, Space Heater connections to be checked and tightened & Test Checks of winding.
Maintenance (TB checking) of LT Motors in TG#1,2,3,4 & SG#1,2,3 Areas , AHP , ESP Areas during Boiler(SG) Shutdown /equipment Shutdown including Motor terminals cleaning, Earth & RTD connections, Space Heater connections to be checked & tightened & test checks of winding, Recording its Values.
Maintenance of LT motors Modules in TG#1,2,3,4 & SG#1,2,3 Areas, AHP, ESP Areas during Boiler(SG) Shutdown / equipment Shutdown including Out Going terminals cleaning, Control Wiring Tightening, Space Heater Supply , Contactor Connections, Fuses, OLR Connections to be checked & tightened &Test Checks , Recording its Values.
Maintenance (TB checking) of LT motors in DMPlant/ FOPH/ DFACS during equipment shutdown including Motor terminals cleaning, Earth connections, RTD &Space Heater connections (if applicable ) to be checked and tightened & test checks of winding, Recording its Values.
Maintenance of LT Motor Modules in DMPlant/ FOPH/ DFACS during equipment shutdown including Out Going terminals cleaning, Control Wiring Tightening, Space Heater Supply, Contactor Connections, Fuses, OLR Connections to be checked & tightened &Test Checks, Recording its Values.
Shifting (or) Lifting of the following 12(a) or 12(b) from one location to another location as per EIC Directives Note:-Hydra crane/Jumbo, if required will be arranged by Department at free of cost.
ESP Rectiformers Shifting (or) Core Lifting of ESP Rectiformers for Testing/ checking.
Weights (20Kgs Stones) from DPS to CPP Elevators (04Nos) Location & Back for Conducting Elevator Load Test at CPP HWP(M).
Transformer oil sample collection and testing (for BDV) as per relevant Indian standard. BDV kit will be provided by department
Replacement/ Drying/ Reactivation of Silica Gel of existing DTRs in TG & SG Area & Generator Cubicles. Note: Required Silicagel will be supplied by the department
Pre-monsoon checks of SG-1,2,3 Rectiformers & Distribution Transformers (DTRS).
Measurement of Insulation resistance value/ PI value of transformer winding/ power cable/ Ckt Breaker/bus bar/motor etc.
Maintenance of 6.6KV VCBs including Fixed & Moving Contacts Cleaning; Operating Mechanism Checking & its Lubrication; Test Checks for ensuring healthiness as per Tech.Specifications.
New Installation or Replacement of Light fixture of various types of LED Luminairies with suitable brackets including wiring of 25mtr & its termination with lugging & Glanding, Fixing with suitable MS channels with proper welding if required.
Troubleshooting / Ckt problem rectification of all types of Light fittings, Power Points or Power Supply Checking of Single phase motors like Ceiling fans, Pedestal fans, Wall mounted fans, Exhaust fans, Air circulators, Water coolers etc. Components will be supplied by Dept. at free of Cost.
Complete Cleaning & fixing of its dooms / Glass/ Grill/ Reflectors/ LED Luminaires/ Lighting JBs of various type of fittings & lamps in CPP area.
Supply and Installation of 2Ft X 2Ft Recessed LED Roof Light Fittings of CPP Area as per the Tech Specs.
Supply and Installation of Revolving (Manual) High Intensity Watch Tower Search Light at WT- 6,7,8 of CPP Area as per the Technical specifications.
Supply and Installation of 220V DC to 24VDC Converter for TG-4 of CPP Area Details as per the Technical and as per the EIC Directives.
Supply and Installation of HM-24 Grade Carbon Brushes of Size 32X32X64 mm as per the Drawing & Details as per the Technical and as per the EIC Directives. for M/s BHEL make TG-1,2,3 in CPP
Supply and Installation of the MF50152V1-1000U-A99 Model ASIC Board Fans for VFDS of CPP Area as per the Tech. specs.
Supply of the LUX METER of standard make Lutron LX-101A with Test Report (or) Calibration Certificate as per details given in Technical Specifications
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .