| 1 | 1₹17.5 CrAccepted-AOC | ₹17.5 Cr | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹18.0 CrRejected-Finance | ₹18.0 Cr | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹18.1 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹18.1 Cr | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹20.4 CrRejected-Finance D NO 55 41 18 1 DOCTOR S COLONY SEETHAMMADHARA VISAKHAPATNAM PIN 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹20.4 Cr | 4 | Rejected-Finance Not being lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Two Class Below the Eligible Class |
Tender Value
₹18.6 Cr
EMD Value
₹12.6 L
Closing Date
25 Mar 2021, 6:00 pmClosed
CE Navy Visakhapatnam
Visakhapatnam Rly Station Road Visakhapatnam-530 004
PROVISION OF DEFICIENT INLIVING ACCOMMODATION FOR SAILORS AT INS CIRCARS VISAKHAPATNAM
2021_MES_417928_1
CE (NAVY)/VIZ/TOKEN/12 OF 2020-2021
Open Tender
Civil Works
730 days
VISAKHAPATNAM
Please refer Tender documents.
12 documents required · 12 mandatory
₹3,000
GE P Navy Visakhapatnam
₹12.6 L
CE Navy Visakhapatnam
24 May 2021
2 Feb 2021
26 Mar 2021
2 Feb 2021
25 Mar 2021
9 Mar 2021
16 Feb 2021
Amount
Phase-I:
Schedule 'A' Part-I to Schedule 'A' Part-XV: Note: Schedule 'A' Part-I to Part-XIV are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for 'Buildings & Structures', as listed in Schedule 'A' Part-I on Serial Page No.33 (R)
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II on Serial Page No.35 (R)
Lump Sum price worked out by the contractor for 'Pile Foundation', as listed in Schedule 'A' Part-III on Serial Page No.36 (R)
Lump Sum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-IV on Serial Page No.38
Lump Sum price worked out by the contractor for 'Internal Electrification', as listed in Schedule 'A' Part-V on Serial Page No.40 (R)
Lump Sum price worked out by the contractor for 'External Water Supply', as listed in Schedule 'A' Part-VI on Serial Page No.41
Lumpsum price worked out by the contractor for 'External Electrification', as listed in Schedule 'A' Part-VII on Serial Page No.44
Lump Sum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-VIII on Serial Page No.46
Lump Sum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-IX on Serial Page No.48 (R)
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-X on Serial Page No.52
Lump Sum price worked out by the contractor for 'Fire Fighting System', as listed in Schedule 'A' Part-XI on Serial Page No.55
Lump Sum price worked out by the contractor for 'Fire Alarm System', as listed in Schedule 'A' Part-XII on Serial Page No.56
Lump Sum price worked out by the contractor for 'Solar Water Heater', as listed in Schedule 'A' Part-XIII on Serial Page No.57
Lump Sum price worked out by the contractor for 'Arboriculture', as listed in Schedule 'A' Part-XIV on Serial Page No.58
Lump Sum price worked out by the contractor for 'Demolition and Dismantling', as listed in Schedule 'A' Part-XV on Serial Page No.58 A
Schedule 'A' Part-XVI: (Miscellaneous Items) (Site Clearance/Area Development/Earth Work/Excavation, Pile Foundation, Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Fire Fighting System, Fire Alaram System, Water Cooler, Cooling Appliances, Aviation Light, Lightening Protection, Solar Water Heater, DG Set, Lifts and Arboriculture):
(SITE CLEARANCE/AREA DEVELOPMENT/EARTH WORK/EXCAVATION):
Removing excavated spoil out side MD land deposited as per the directions of the local authorities. Note: The excavated earth shall be removed to the locations as permitted by the local administrative authorities. The royalty if any is to be paid shall be borne by the contractor.
PILE FOUNDATION:
Boring for 600mm dia. bored cast in situ piles in any srata except SDR/highly fractured rock and getting out and disposal of spoil to a distance 50 metres using DMC method (Direct mud circulation) complete all as specified and shown on drawings and as directed.
Boring for 450mm dia. bored cast in situ piles in any srata except SDR/highly fractured rock and getting out and disposal of spoil to a distance 50 metres using DMC method (Direct mud circulation) complete all as specified and shown on drawings and as directed.
Boring for 600mm dia. bored cast in situ piles in SDR/hard rock and getting out and disposal of spoil to a distance 50 metres using DMC method (Direct mud circulation) complete all as specified and shown on drawings and as directed.
Boring for 450mm dia. bored cast in situ piles in SDR/hard rock and getting out and disposal of spoil to a distance 50 metres using DMC method (Direct mud circulation) complete all as specified and shown on drawings and as directed.
M&L for MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe-410 S by welding the joints, strengthening wherever required, providing stiffners, lifting hooks including all T&P required, shifting the same from position to positions required, driving in true vertical alignment in position to the required level for piles complete, all as specified and directed. Note: MS Pipe liner shall be casted as mentioned in drawing. How ever for payment purpose, the depth of pile liner shall be measured up to cut off level only irrespective of the depth provide for retaining concrete/ bentonite slurry. The unit rate/lumsum price quoted shall be deemed to include for the above aspect.
Chipping of laitance concrete in piles above cut of level up to a maximum of 1m from cut of level and disposal to distance of exc. 1.5 Km but n. exc. 5 Km and depositing where directed complete all as specified and as directed.
Carrying out initial load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out initial load test on 450mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine load test on 450mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out pull out test on cast in situ pile 600mm dia. as per IS complete all as specified and as directed.
Carrying out lateral load test on cast in situ pile 600mm dia. as per IS complete all as specified and as directed.
Carrying out low strain integrity test on cast in situ piles including analysing the result as per ASTM D 5882 complete all as specified and as directed.
INTERNAL WATER SUPPLY:
S&F 15mm dia. Fancy type chromium plated health faucet with steel flexible pipe complete all as specefied and as directed
INTERNAL ELECTRIFICATION:
Ponit wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multistranded 1100 Volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marking, including pressed steel terminal box made with MS sheet 2mm thick suitable for fixing switches, sockets, inculding one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for One light point controlled by one switch or One bell point controlled by bell push or One fan (ceiling/Wall/Ex.fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps socket on independent board.
All as per item No.31 here-in-before but one light point controlled by two Nos. two way switches complete all as specefied and directed.
All as per item No.31 here-in-before but One 3 pin socket outlet 15 Amps on independent board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuty.
M&L submain wiring concealed type for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with acessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
All as per item No.34 but with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire. Note for Item Nos.34 & 35: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
S&F concealed in wall MCB DB vertical type double door TPN 4 way 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar, including provision as incommer MCCB FP up to 160 Amp and outgoing circuits complete, fill empty with blanks, making good the disturbed area as per existing surface complete all as specefied and directed.
S&F energy efficient 4 feet LED light fitting 20 Watt, 230 Volts surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc. including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
S&F energy efficient 2 feet LED light fitting 10 Watt, 230 Volts surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
S&F LED security light 20 Watt new generation energy saving, environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre-wired with 1.5 Sq.mm. copper conductor cable up to connector including 2 Mtr. long GI tubing medium grade 25mm dia. bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directred.
S&F ceiling fan AC single phase 230 Volts of size 1200mm sweep with all fixtures, 5 Star rating, metallic body complete all as specefied and directed.
S&F exhaust fan 450mm sweep, plastic body (Heavy duty), complete with louvers suitable for operation on 230 Volts AC, 50 Hz fixed on wall making opening, fixing and making good the distrubered surfaces etc. complete all as spcified and as directed.
S&F exhaust fan 200mm sweep, plastic body (Heavy duty), complete with louvers suitable for operation on 230 Volts AC, 50 Hz fixed on wall making opening, fixing and making good the distrubered surfaces etc. complete all as spcified and as directed.
M&L for earthing complete with GI earth plate electrode 60cmX60cmX 6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4mm dia. by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe connected up to DBs, and suitable CI top cover with handle, funnel, strainer, char coal and testing on completion all as specified and as directed. Note: Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type C1 in pad and pit complete all as specefied and directed.
M&L for 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
EXTERNAL WATER SUPPLY:
Supply.lay, connect, test and commission Heavy grade MS piping for down comer & following branch piping including pipe fittings, jointing material and applying two coats of synthetic enamal paint (RED COLOUR) over a coat of red oxide primer etc. and all as specified and as directed.of the following sizes :-
GI pipes Heavy Class, 50mm bore.
GI pipes Heavy Class, 80mm bore.
S&F foot valves, flanged of class 1.6 PN supplied and installed complete, size 80mm dia. complete all as specified and as directed.
M&L for construction of valve chamber of size 750x750x750mm (internal dimentions) including excavation of earth work in any type of soil, 50mm thick PCC 1:5:10 type E2 as in foundation, made out of 200mm thick brick work in cement mortar 1:6 with 15mm thick plastering in cement mortar 1:4 internally complete and up to 50mm below ground level for external faces with 100mm thick plain cement concrete 1:3:6 type B1 using 20mm graded aggregate as in coping, cover frame made up of 50x50x6mm and 3mm thick MS sheet as cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia. with neccssary locking arrangement including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of white wash on plastered surfaces complete all as specified and as directed.
M&L for cutting existing steel tubing 100mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of sixe 100x100x80mm for tapping complete all as specified and as directed.
S&F monobloc pump set suitable for 415 Volts, 3 Phase system having capacity 5 HP with CI casing bronze impeller and stainless steel shaft bounted on heavy duty bearing suitable for 40m head, 10 LPS discharge including necessary PCC foundation, form work etc. complete all as specified and as directed.
S&F DOL starter with 'D' range contactor & LR1D OLD for 3 Phase pump set up to capacity 5 HP including connection and testing etc. complete all as specified and as directed.
EXTERNAL ELECTRIFICATION:
Supply & install, testing and commisining of transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 Volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 energy efficiency level II of capacity 250 KVA complete all as specified and as directed comprising of the following items: (a) Lifting lugs/hooks for transformer and tank (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level gauge (g) Silica gel breather (h) First oil fill up up to the recommended level by manufacturer with new natural easter oil conforming to IS. (j) Type of connection: Delta/Star (k) Type of cooling: ONAN (l) Vector Group: DYN 11 (m) Type of connecting arrangement: Cable termination boxes on both HT and LT side (n) Temperature rise as per IS 1180 natural Easter Oil cooled. (o) All necessary arrangements with devices for measuring the temperatures of core, winding and oil. (p) Radiators shall be hot dip galvanised (HDG) to avoid corrosion. (q) In addition to the above all standard fittings shall be provided as per IS norms
Material and Labour for masonry platform for transformer, of size 2m x 2m x 1.5 m height above ground level and 0.60 m below ground level PCC Blocks in cm 1:6 including excavation and earth work in any type of soil foundation in PCC 1:2:4 type B1 with 20mm graded aggregate 10cm thick at top of the platform over 75mm thick PCC(1:4:8) sub base over approved earth filling and, plastering 20mm thick in cm 1:4 on PCC Blocks walls and applying three coats of white wash etc complete all as directed by engineer-in-charge.
Supply, install, testing and commissioning RMU outdoor type consisting of 3 Nos. manually operated load break switches floor mounted with manually operated earth switch, extendable on both side, with rated voltage of 11 KV & rated current of 630 Amp, with breaking current of 21 KA/3 Sec including fault passage indicator, voltage presence indicator, with sensor, electrolytic grade bus bar enclosed in one SF6 tank, RMU enclosure sheet steel having IP 54degree of protection, stainless steel gas tank enclosures having IP 67 degree protection etc. complete all as specified and as directed.
Supply, fix and testing of integral LED street light luminaire 72 Watts, comprising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and as directed. Make: Bajaj Cat. Part No.BRTFG72 W LED
Supply, fix and testing of loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, combi climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, 'C' curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands etc. complete all as specified and as directed.
S&F time switches 250 Volts single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 Volts grade, of size 3 core 120 Sq.mm. complete all as specified and as directed. Note: Excavation and PCC shall be measured and paid separately.
S&F cable jointing kit for 11 KV grade cable for indoor termination heat shrink type, joint complete with jointing material and accessories suitable for 3 core 120 Sq.mm. XLPE armoured aluminium conductor cable complete all as specified and as directed.
S&F cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type, joint complete with jointing material and accessories suitable for 3 core 120 Sq.mm. XLPE armoured aluminium conductor cable complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core 120 Sq.mm. XLPE armoured aluminium conductor cable complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:
3½ core 400 Sq.mm. (Transformer to main FPB)
3½ core 300 Sq.mm. (LT Panel to Bldg Panel)
3½ core 95 Sq.mm. (LT Panel to APFC Panel)
4 core 25 Sq.mm. (From main building panel to each floor)
4 core 16 Sq.mm. (DG panel to all 3 lift rooms & for P/H for fresh water)
4 core 10 Sq.mm. (For street light & for booster pump)
Suppy, fixing and testing of LT panel board made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, lifting hooks with shutter type ventilating louver at both sides & bottom, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/bolts etc. used are to be made of rust proof material including as per IS:8623 aluminium TPN bus bar of 600 Amps rating with heat proof colour code, insulators suitable for three phase and nutral, LT AC, 50 Hz 415 Volts complete with powder coating, necessary internal electric connections as required with and inclusive of the following complete all as specified and directed (Near Transformer): INCOMING: lT 440 Volts, 3 Phase 4 wire 50 Hz, 50 KA, adjustable thermal and adjustable magnetic type MCCB of 400 Amps rated vomplete with overload protection-01 No. OUTGOING: (a) IT 440 Volts, 3 Phase 4 wire 50 Hz, 50 KA, adjustable thermal and adjustable magnetic type MCCB of 250 Amps rated complete with overload protection-02 Nos. (01 No. for buildingg load and 01 No. spare) (b) IT 440 Volts, 3 Phase 4 wire 50 Hz, 40 KA, adjustable thermal and adjustable magnetic type MCCB of 100 Amps rated complete with overload protection-03 Nos. (01 No. for DG panel, 01 No. for APFC panel and 01 No. spare) Contd...
(c) LED indicating lamps for each phase with colour coated red, yellow, blue phases (d) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breakers
Supply fixing and testing of LT Panel board made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, lifting hooks with shutter type ventilating louver at both sides & bottom, danger notice plate, stickering of switcher gear about termination of switch gear, and the nuts/bolts etc. used are to be made of rust proof material including as per IS:8623 aluminium TPN bus bar of 150 Amps rating with heat proof colour code, insulators suitable for three phase and neutral, LT AC, 50 Hz 415 Volts complete with powder coating, necessary internal electric connection as required and provision of the following: (DG panel) complete all as specified and directed: INCOMING: (a) IT 440 Volts, 3 Phase 4 wire 50 Hz, 40 KA, adjustable thermal and adjustable magnetic release type MCCB of 100 Amps rated complete with overload protection-01 No. OUTGOING: (a) IT 440 Volts, 3 Phase 4 wire 50 Hz, 25 KA, adjustable thermal and adjustable magnetic release type MCCB of 32 Amps rated complete with overload protection-08 Nos. (02 Nos. for 8 passenger lift, 01 No. for booster pump, 01 No. for street light and 01 No. spare 02 Nos. for fresh water pumps and 02 Nos. spare) (c) lT 440 Volts, 3 Phase 4 wire 50 Hz, 25 KA, adjustable thermal and adjustable magnetic release type MCCB of 40 Amps rated complete with overload protection-02 Nos. (01 No. for 13 passenger lift and 01 No. spare) (d) LED indicating lamps for each phase with colour coated red, yellow, blue phases Contd...
(e) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breakers
Supply fixing and testing of LT Panel board made out of CRCA sheet 2mm thick Indoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, lifting hooks with shutter type ventilating louver at both sides & bottom, danger notice plate, stickering of switcher gear about termination of switch gear, and the nuts/bolts etc. used are to be made of rust proof material including as per IS:8623 aluminium TPN bus bar of 400 Amps rating with heat proof colour code, insulators suitable for three phase and neutral , LT AC, 50 Hz 415 Volts complete with powder coating, necessary internal electric connection as required with and inclusive of the following complete all as specified and directed (Main Building Panel): INCOMING: LT 440 Volts, 3 Phase 4 wire 50 Hz, 36 KA, adjustable thermal and adjustable magnetic release type MCCB of 200 Amps rated complete with overload protection-01 No. OUTGOING: (a) LT 440 Volts, 3 Phase 4 wire 50 Hz, 25 KA, adjustable thermal and adjustable magnetic release type MCCB of 63 Amps rated complete with overload protection-08 Nos. (01 No. for each floor and 01 No. spare) (b) LT 440 Volts, 3 Phase 4 wire 50 Hz, 16 KA, adjustable thermal and adjustable magnetic release type MCCB of 25 Amps rated complete with overload protection-02 Nos. (01 No. for GF and 01 No. spare) (c) LED indicating lamps for each phase with colour coated red, yellow, blue phases. (d) Intelligent panel meter to measure voltage, current, frequency etc. with all connected CTs of each breakers
M&L for earthing complete with galvanized earth plate electrode 600x 600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized iron strip of 32x6mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick hinged to CI frame with MS bar 6mm dia. 150mm c/c reinforcement, watering funnel, 50mm dia. light grade pipe for protection of earth electrode and 20mm dia. pipe for watering all as specified and directed and tested on completion complete all as specified and as directed.
M&L for GI earth strip of size 32x6mm with saddles and fixing screws etc. for roof/wall complete all as specified and as directed.
S&F metal and plug socket combination 32 Amps, TPN type for lift machine complete all as specified and as directed.
FIRE FIGHTING SYSTEM:
S&F DOL starter with 'D' range contactor & LR1D OLD for 3 Phase pump set of capacity 5 HP complete all including connections and testing complete all as specified and as directed.
S&F fire extinguisher of capacity 3 Kg, CO2 type, light weight, squeeze grip type confirming to IS 15683 complete all as specified and as directed.
S&F fire extinguisher of capacity 4 Kg, dry chemical powder (ABC) type confirming to IS 15683 all as specified and as directed.
FIRE ALARM SYSTEM:
S&F FRLS armoured copper cable 2 core 1.5 Sq.mm., passes through steel rigid conduit as per IS 1554 fixed to wall/roof/false ceiling/floors with necessary clamps/saddles complete all as specified and as directeed.
WATER COOLER:
S&F water cooler electric driven (single phase), fully stainless steal body having approx storage capacity of 80 Litre and nominal cooling capacity of 40 Litres per hour complete all as specified and as directed.
Supply, fix and testing of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ±2.5% and of capacity 2 KVA complete all as specified and as directed.
COOLING APPLIANCES:
S&F refrigerator, electric driven (single phase), capacity 500 Litres, BEE 5 star rated complete all as specified and as directed.
Supply, installation and commisioning of metal top deep freezer, hard top, 320 Litres capacity, single phase, 240 Volt, 50 Hz, single door complete all as specified and as directed.
Supply, fix and testing of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ±2.5% and of capacity 2 KVA complete all as specified and as directed.
AVIATION LIGHT:
S&F aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed. Make: Bajaj Cat. No.BGAB302 LED
S&F PVC insulated armoured PVC sheathed LT cable 1100 Volts grade with copper conductor of size 3 core 2.5 Sq.mm. multi stranded conductor, fixed to wall/roof etc. with suitable calmps, spacers, bolts & nuts including rigid PVC conduit 25mm dia. etc. complete all as specified and as directed.
S&F time switches 250 Volts single phase, 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
LIGHTNING PROTECTION:
S&F single pointed air termination aluminium rod, 12mm dia., 300mm long complete all as specified and as directed.
S&F aluminium strip 25x3mm complete with saddles porcelain cleats of suitable size and fixing screws for fixing the strip complete all as specified and as directed.
S&F test point terminal box of size 200x100x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 6 Nos. 15mm long hexagonal head screws complete with test point terminal block made out of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed.
M&L for earthing complete with galvanized earth plate electrode 600x 600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized iron strip of 32x6mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick hinged to CI frame with MS bar 6mm dia. 150mm c/c reinforcement, watering funnel, 50mm dia. light grade pipe for protection of earth electrode and 20mm dia. pipe for watering all as specified and directed and tested on completion complete all as specified and as directed.
M&L for GI earth strip of size 32x6mm with saddles and fixing screws etc. for roof/wall complete all as specified and as directed.
SOLAR WATER HEATER:
Supply, Install, testing and commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 300 LPD complete all as specified and as directed.
Supply, Install, testing and commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD complete all as specified and as directed.
S&F hot water GI pipe 20mm dia. duly insulated with glass wool and aluminium cladding complete all as specified and as directed.
S&F hot water GI pipe 25mm dia. duly insulated with glass wool and aluminium cladding complete all as specified and as directed.
DG SET:
Supply, install, testing and commissioning of silent engine generating set with accoustic enclosure as per CPCB norms 415 Volts 62.5 KVA 3 Phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/2613/ 5000 complete all as specified and as directed, with and including the following:
(A) Alternator: Standard design alternator rated at 62.5 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 Phase 4 wire 415 Volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, the alternator conforming to BS 2613/5000 and imposition to generate supply with frequency regulation with in +1% tolerance and suitable for tropical climate and shall generally conform to BS-2613/5000/IS 4722 complete with standard accessories all as specified and required for safe handling and operation salient features of accessories as under:
(i) Insulation class 'H‘ (ii) Temperature rise Class 'H‘ (iii) Excitation: Self Excited (iv) Regulation performance: The voltage is kept constant with +1%, manual voltage adjustment within +5% (v) Frequency regulation +1%
(B) Diesel Engine: Adequate capacity of diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust system complete with exhaust piping of suitable size with MS pipe of suitable size light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/frequency regulation, fuel filters, fuel hoses. (vi) Lub Oil System: Lubricating oil filter Lubricating oil pump (vii) Air Intake System: Air intake manifold Air cleaner dry type (viii) Governor: Electronic Governor
(ix) Starting System: Electric self starter with maintenance free battery including battery charging alternator. (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch. Handling and operation: Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine.
(xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories: AVM pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms. (xvi) Fuel Tank: Fuel Tank of capacity to suit Daily 12 hours service fuel tank made out of 2mm thick (14G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base inside the acoustic enclosure. (xvii) MS pipe line to and from the fuel tank to the DG Set.
(C) AMF Panel: Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 Volts 3 Phase 4 wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole MCCBs and contactors of capacity as recommended by the manufacturer including detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, PF, temperature, battery voltage, etc. complete with standard accessories all as specified and required for safe handling and operation salient features of accessories as under:
(D) Accoustic Enclosure: Manufactured by OEM suitable for 62.5 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be inside the enclosure (v) Construction Details/specification as follows: (a) Outer body: CRCA Sheet of 2.0 mm thick (b) Doors: CRCA sheet of 1.6 mm thick (c) Sound Insulation: As per OEM Norms
(vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform. (viii) The fuel tank is to be located in substation building and cost of the fuel lines is deemed to be included in the offer. (ix) The DG set should be provided with external emergency stop push button. (x) The enclosure should be suitably illuminated by LED Lamp fittings. (xi) The noise level should be 75 dba at 1m under free field conditions. (xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade.
M&L for earthing complete with galvanized earth plate electrode 600x 600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized iron strip of 32x6mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick hinged to CI frame with MS bar 6mm dia. 150mm c/c reinforcement, watering funnel, 50mm dia. light grade pipe for protection of earth electrode and 20mm dia. pipe for watering all as specified and directed and tested on completion complete all as specified and as directed.
LIFTS:
(f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. (g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping system having relays etc. (Overload protectin/tripping system) (j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be conformity with IS 3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38mm hairline finish. (l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4mm thickness of suitable size as specified. (n) Specification plate with complete details. (p) Contineuos earthing for machine and equipments with 32x6mm GI strip. (q) Steel wire rope of adequate size as per relevant IS and as per manufacturerer specifications. (r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (s) Full length display indicator panel. (t) Main drives and control shall be of latest, high effective and low power consumption. (u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. Contd...
(v) Stainless steel car door & landing door with small opening for vision of size 200mmx800mm with toughended galss not less than 8mm thick. Make of Toughened Glass: Safgex/Saint Gobain Glass/Modiguard Float Glass/Kesar/Asshi Indian/Atul Tuf/Hindustan Pilkington Glass Works/ Trivenin Float Glass. (w) Intercome be connected with nearest security post Note: Defect liability period will be two years from date of complition.
(f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. (g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping system having relays etc. (Overload protectin/tripping system) (j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be conformity with IS 3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38mm hairline finish. (l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4mm thickness of suitable size as specified. (n) Specification plate with complete details. (p) Contineuos earthing for machine and equipments with 32x6mm GI strip. (q) Steel wire rope of adequate size as per relevant IS and as per manufacturerer specifications. (r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (s) Full length display indicator panel. (t) Main drives and control shall be of latest, high effective and low power consumption. (u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. Contd...
(v) Stainless steel car door & landing door with small opening for vision of size 200mmx800mm with toughended galss not less than 8mm thick. Make of Toughened Glass: Safgex/Saint Gobain Glass/Modiguard Float Glass/Kesar/Asshi Indian/Atul Tuf/Hindustan Pilkington Glass Works/ Trivenin Float Glass. (w) Intercome be connected with nearest security post Note: Defect liability period will be two years from date of complition.
ARBORICULTURE
Supply & planting Korean Carpet grass by piece turfing including preparation of ground deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed.
Supply & plantation of crotons and hedges of 30cm height (At 30cm c/c) including preparation of ground to required depth and filling of good earth including watering etc. complete all as specified and as directed.
Supply & planting Ashoka plant including preparation of ground up to 30cm deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed.
Supply & planting Gulmohar (Hybrid) plant including preparation of ground up to 30cm deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed.
Supply & planting Jamun plant including preparation of ground up to 30cm deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed.
Supply & planting Royal Palm tree including preparation of ground up to 30cm deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed. Note for Item Nos.94 to 99: Loose soil and cow dung will measured separately.
Supply only approved loose soil best quality for plantation all as specified.
Supply only approved vermi compost of the best quality all as specified.
Supply only approved manure (cow dung) of the best quality all as specified.
Phase-II:
SCHEDULE 'A' PART-XVII: Maintenance of Arboriculture
M&L for maintenance of arboriculture as provided under Item Nos.94 to 99 of BoQ by weeding housing saucer melding once in every 15 days including planting new plants/grass of same spices and height if required with out any extra cost to the department for a period of TWELVE MONTHS complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all the labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading/spraying organic manure, chemical fertilizers, pesticides to the required extent complete all as specified and directed.
Phase-III:
SCHEDULE 'A' PART-XVIII: Comprehensive maintenance of Electrically Operated Lifts for the First Year after Defect Liability Period under GE (P) Navy Visakhapatnam.
Comprehensive mainenance of electrically operated Passenger lifts (2 Nos.) (8 passenger) passengers to serve ground plus eight upper floors complete including ARD and all connected components of liftduring 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of electrically operated Passenger lifts (1 No.) (13 passenger) passengers to serve ground plus eight upper floors complete including ARD and all connected components of liftduring 1st year after expiry of Defect liability period all as specified and directed.
Phase-IV:
SCHEDULE 'A' PART-XIX: Comprehensive maintenance of Electrically Operated Lifts for the Second Year after Defect Liability Period under GE (P) Navy Visakhapatnam.
Comprehensive mainenance of electrically operated Passenger lifts (2 Nos.) (13 passenger) passengers to serve ground plus eight upper floors complete including ARD and all connected components of liftduring 2nd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of electrically operated Passenger lifts (1 No.) (8 passenger) passengers to serve ground plus eight upper floors complete including ARD and all connected components of liftduring 2nd year after expiry of Defect liability period all as specified and directed.
Phase-V:
SCHEDULE 'A' PART-XX: Comprehensive maintenance of Electrically Operated Lifts for the Third Year after Defect Liability Period under GE (P) Navy Visakhapatnam.
Comprehensive mainenance of electrically operated Passenger lifts (2 Nos.) (13 passenger) passengers to serve ground plus eight upper floors complete including ARD and all connected components of liftduring 3rd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of electrically operated Passenger lifts (1 No.) (8 passenger) passengers to serve ground plus eight upper floors complete including ARD and all connected components of liftduring 3rd year after expiry of Defect liability period all as specified and directed.
(viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personnel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I.
SVS PROJECTS
SOOD ASSOCIATES PVT LTD
PMR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid