Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹35.0 L+₹71,590.50 (2.09%)Rejected-Finance 213 F BLOCK MEGA MARGANPATTE HADAPSAR PUNE 411013 | PUNE | MAHARASHTRA | 411013 | L2 | Rejected-Finance Rejected not lowest | |
| 3 | L3₹35.4 L+₹1.1 L (3.19%)Rejected-Finance FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L3 | Rejected-Finance Rejected not lowest | |
| 4 | L4₹36.8 L+₹2.5 L (7.35%)Rejected-Finance | L4 | Rejected-Finance Rejected not lowest | |
| 5 | L5₹36.9 L+₹2.6 L (7.64%)Rejected-Finance | L5 | Rejected-Finance Rejected not lowest |
Tender Value
₹41.4 L
EMD Value
₹82,800
Closing Date
11 Oct 2023, 6:00 pmClosed
GE Dehu road
GE Dehu road Pune
PROVN OF STORE ROOM FOR RATION STORAGE AT SUPPLY POINT UNDER GE DEHU ROAD.
2023_MES_618591_1
8800
Open Tender
Civil Works
Item Rate
270 days
GE Dehu road
as per tender document
7 documents required · 7 mandatory
₹500
GE Dehu road
₹82,800
Yes
24 May 2024
13 Sept 2023
13 Oct 2023
13 Sept 2023
11 Oct 2023
27 Sept 2023
Amount
Surface excavation n.exc 30cm deep and avraging 15cm deep and getting out in soft loose soil complete all as specified and directed by Engr-in-Charge.
Removing excavated soil exc 250 m and n. exc 500m and deposited complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No 3 here in before but depth exc. 1.5m and getting out in hard/ dense soil complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No 3 here in before but depth exc. 1.5m and getting out in soft rock complete all as specified and directed by Engr-in-Charge.
M & L Cement Concrete Type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M & L for Fe 500D TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M & L for mild steel TMT bars 6-8 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
Ditto as per item No 8 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed by Engr-in-Charge.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed by Engr-in-Charge.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed by Engr-in-Charge.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed by Engr-in-Charge.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed by Engr-in-Charge.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed by Engr-in-Charge.
M & L for use and waste of form work to sides of roof slab nexc 20cm thick/wide with rough finished surface complete all as specified and directed by Engr-in-Charge.
M & L for providing reinforced cement concrete M-25 design mix, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed by Engr-in-Charge.
M & L for providing reinforced cement concrete M-25 design mix, using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed by Engr-in-Charge.
M & L for providing reinforced cement concrete M-25 design mix, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed by Engr-in-Charge.
M & L for providing reinforced cement concrete M-25 design mix, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed by Engr-in-Charge.
M & L for providing reinforced cement concrete M-25 design mix, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soft /loose & hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for filling of moorum or red bajri under floors or paving, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-Charge.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed by Engr-in-Charge.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engr-in-Charge.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed by Engr-in-Charge.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed by Engr-in-Charge.
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub base of floor finished even and rough complete all as specified and directed by Engr-in-Charge.
M & L for providing 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor for ramp surface finished even and rough complete all as specified and directed by Engr-in-Charge.
M & L for providing 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm grade stone aggregate) as in sub floor of floor finished even and rough complete all as specified and directed by Engr-in-Charge.
M&L 75 mm thick P.C.C 1:3:6 type C-2 using 40 mm graded aggregate as in plinth protection cement concrete surface complete all as specified and directed by Engr-in-Charge.
M & L for providing 75 mm thick cement concrete 1:2:4 type B-2 (using 40 mm grade stone aggregate) surface finished even and smooth and further making impression of expanded metal to ramp complete all as specified and directed by Engr-in-Charge.
M&L Pre-cast cement concrete block masonry with solid blocks of grade D-5 (IS 2185-1979 part -I ), exc. 10 cm in width and setting in CM 1:6,complete all as specified and directed by Engr-in-Charge.
M&L for P.C.C 1:2:4 type B-0 using 12.50 mm graded aggregate as in DPC mixed with water proofing compund @ 3% by wt of cement complete all as specified and directed by Engr-in-Charge.
Supply only Integral waterproofing compound
M&L for water proofing treatment using polymerised membrane to roof slab including 10 mm thick plaster in cement mortar 1:4 as in roof mixing with WPC mixing with water proofing compound by 3% by weight of cement or as per manufactire instruction . Water proofing treatment shall be as under:- (a) Applying cold bitumenous oil based primer IS No 3383 @ 250 Gms/Sqm and laying APP Modified membrane with non woven polymer reinforcement / mat core (Centre core) not less than 3 mm thick and not less than 3.50 kg/sqm the overlap shall be 100 mm on length side and 100 mm on width side and all as per manufacturer instruction complete.The roof surface shall be thoroughly wire brushed, washed, dried up & cleaned to remove all foreign materials & dust to receive primer.Top surface shall be applied with 0.15 Kg/Sqm bitumenous aluminium paint complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick in CM 1:6 on internal surface of block masonry/ concrete wall with sagol finish complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick in CM 1:4 on fair faces of external surface of masonry/ concrete wall mixed with water proofing compound finished even & fair complete all as specified and directed by Engr-in-Charge. (Note: WPC shall be measured & paid seperately)
M & L for 5 mm thick rendering on ceiling in cement mortar 1:3 with sagol finish complete all as specified and directed by Engr-in-Charge.
M & L machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 15mm thick in CM 1:6 and jointed with grey cemnet slurry mixd with pigment to match the shade of the slab incl cutting and mirror polishing complete all as spcified and directed by Engr-in-Charge.
All as per item no 40 above but on skirting incl 10mm thick rendering in CM (1:4) complete all as specified and directed by Engr-in-Charge.
M & L machine cut kota stone on cill of ventilator 20-25mm thick over in 15mm thick CM 1:6 , with 25mm projection on both sides of wall and moulding of edges complete all as spcified and directed by Engr-in-Charge.
S&F aluminium powder coated ventilator sliding type (3 track) with frame size100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one mesh shutter incl necessary jointing cleats glazing clips, rubber packing,and locking arrangement powder coated aluminium snap beading screws including 4mm plain float glass & 0.36 mm dia and 1.4 mm width of aperture stainless steel wire mesh, fittings etc complete all as specified and directed by Engr-in-Charge.
S&F for framed work uch as grills,grating, etc,with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge.
S&F Steel rolling shutters without ball bearing 1.25mm thick laths as specified including top cover, anchoring rod, hasp and staple ,gear operated type with bevel gear box and crank handle and one shop coat of primer; erected in position as indicated complete all as specified and directed by Engr-in-Charge.
M&L three coats of white wash on new plastered inner surfaces on wall including preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
M&L three coats of white wash to new plastered surfaces on ceiling including preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
M&L applying two coats of premium acrylic smooth exterior paint with silicone additives on external surfaces of wall applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm and preparation of surfaces as per manufacturers instruction complete all as specified and directed by Engineer-in-charge.
M&L for preparation of steel surfaces of any description over 10cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed by Engineer-in-charge.
M&L for preparation of steel surfaces of any description over 10cm in width or girth not otherwise described and two coat of synthetic enamel paint for rolling shutter complete all as specified and directed by Engineer-in-charge.
M & L Writing letters or figures (Block Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed by Engineer-in-charge.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L cement concrete work in pavement/hardstanding of fexural strenght 40kg/per sq cm in field using 400 kgs of cement per cubic metre thickness of concrete 25cm or less complete all as specified and directed by Engr-in-Charge.
Finishing surface of concrete roads, pavements etc by brooming complete all as specified and directed by Engr-in-Charge.
M & L for forming 12 mm thick expansion joints 150 mm deep, filled with preformed bituminous filler and top 30 mm primed and sealed with sealing compound grade 'A' complete all as specified and directed by Engr-in-Charge.
M & L for forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound grade 'A' complete all as specified and directed by Engr-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed by Engr-in-Charge
Supply,laying,jointing , testing and commisioning XLPE cable 1100 volts grade PVC insulated armoured & PVC sheathed with stranded aluminium conductor heavy duty ISI marked incl cable glands lugs bolts nuts washers etc to suit the cable size to be laid in trenches fixed along pole, LT pannel floor bore or through GI pipe laid under floors, Fixed, concealed in wall encased in GI pipe etc complete of following sizes including taking down old unserviceable over head conductors and insulators channels carefully as directeed by engineer in charge
10 Sqmm x 2 Core
M & L for HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :-
40 mm dia
M & L of new Gl steel tube Light grade galvanized of size 80 mm dia with all fitting laid in trenches complete and all as specified and directed by Engr in charge.
M&L for point wiring with two single core 1.5 sqmm multistranded copper conductor cable of PVC insulated and unsheahed type alongwith 1.5 sqmm PVC insulated unsheathed single stranded copper conductor cable for continous earthing in & incl casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/(MS steel strips if required) including hard PVC boards of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator setc for Note:- Screws used for fixing PVC boards, casing & caping ceilling rose square blocks etc should be nickel cadmium screws:-
(a) One light point controlled by one switch
(b) One fan point controlled by one switch & regulators
(f) One socket 5 pin 5 Amps flush type on independent board
(f) One socket 5 pin 5 Amps flush type on same board
M&L for point wiring with 2.5 sqmm two single core multistranded copper conductor cable of PVC insulated and unsheathed type alongwith 2.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
S&F switch piano flush type single pole one way 5 Amps
S&F switch socket combination 2 in 1, 5 Amps flush type
S&F switch socket combination 2 in 1, 15 Amps flush type
S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block
S&F regulator electronic step type for ceiling fans suitable for AC 230 volts 50 Hz 1200 / 1400mm sweep
MCB DB SPN sheet metal enclosure double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 8 way.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning as follows:
MCB SP 5-32 Amps.
MCB SPN 32 Amps.
Supply and fix in repair LED T-5 Fitting 20 Watts LED including provision of connections cable pvc unsheathed stranded copper conductor and pvc square block of size 80mmX80mm all as directed by Engr- In charge. MAKE :Havells , Philips , Crompton
Supply and fixing LED street light fitting 35/40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, frame and louvers with complete accessories all as directed by Engr - In - Charge
Material and labour for replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including MS clamps made out of 40mmX6mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size all as directed incl taking down of old unserviceable bracket.
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick burried burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plare No 3,connected to earthing test point all as specified or indicated including testing on completion including excavation and earth work in any strata,PCC Chamber with cover,Charcoal and Salt as required & 15 mm Light Grade GI pipe from steel plate to DB in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge.
Crown Chemicals
Santhi Enterprises
H S TAKHI
KARPE AND SONS CONSTRUCTION
PREETI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .