| Sl No | Description | Qty | Unit | rajengineers L2 | fakhrie apostrical L1 |
|---|---|---|---|---|---|
| 1.00 | Supply , installation , testing and commissioning of microprocessor based 1 loop capacity analouge addressable fire alarm control panel with minimum 80 characters LCD display, 800 event plus, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spares capacity in each loop. Each loop shall have a capacity of minimum 300 analouge addressable device. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC Power supply, automatic battery charger , 2 x 12 Volts , 7 AH sealed lead acid batteries . Designed to meet UL 864 10th edition - 1 loop control panel with single mode fiber card High speed network communication module upto 25 KM (15.5 miles) between nodes using 9/125 micrometer single mode fiber.Model NFS-320 + HS NCM SF of Make Notifier/ Honeywel / Cease Fire/EDWARD/Siemens | 1 | EACH | 6,68,458 ₹6.7 L | 3,40,000 ₹3.4 L |
| 2.00 | Supply , installation , testing and commissioning of network control annuciator with 640 character display used to present event information from the network with alphanumeric QWERTY rubber keypad with tactile and audible feedback. Multiple passwords and access levels. Support digital voice command (DVC) for network audio application. UL/FM approved with single mode fiber card high spped network commucation module upto 25 KM (15.5 miles) between nodes using 9/125 micrometer single mode fiber as specified as directed by Engineer in Charge. Model NCA-2 ONYX + HS NCM SF Make Notifier Honeywell Cease Fire/EDWARD/Siemens/ Ravel | 1 | EACH | 8,15,828 ₹8.2 L | 3,50,000 ₹3.5 L |
| 3.00 | Supply and fix Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination photoelectirc/optical with base with self built intelligence , the detector should have group decision technology for faster responce & avoid false alarms, the detector shall have twin bi color LED for 360 degree viewing addressing shall be with user friendly roatary decimal switches designed to meet UL 268 7th edition as specified as directed by Engineer in Charge.
Make Notifier Honeywell / Cease Fire/EDWARD/Siemens/Ravel | 60 | EACH | 973 ₹58,380 | 3,200 ₹1.9 L |
| 4.00 | Supply , installation testing and commissioning of sounder cum strobe rated at 80 dBA @ 3m for audible and 115 cd flashing at 1Hz for visual indicaiton UL listed as specified as directed by Engineer in Charge.
Make Notifier Honeywell or any other equivalent Make Notifier Honeywell / Cease Fire/EDWARD / Ravel/Siemens | 1 | EACH | 6,133 ₹6,133 | 10,000 ₹10,000 |
| 5.00 | Supply, installation and commissioning and testing of Addressable manual call point - Resettable type-with back box with binary coded address setting with status LED for 360 visibilty- IP 50 Rating as specified as directed by Engineer in Charge. Make Notifier Honeywell / Cease Fire/EDWARD/ Siemens/ Ravel | 9 | EACH | 5,177 ₹46,593 | 3,200 ₹28,800 |
| 6.00 | Supply, installation , testing and commissioning of addressable control module for sounder/strobes/sounder cum strobs . The control module shall provide supervised NAC output rated 24V DC 2A. The device shall have an LED whick blink in normal state and get steady on activation to monitor the health status of the device. Addressing shall be with user friendly rotary decimal switches, moduler shall be supplied with mounting plate from IEM for ease of installation and maint as specified as directed by Engineer in Charge.
Make Notifier Honeywell/ Cease/ Fire/EDWARD/Siemens/Ravel | 1 | EACH | 5,495 ₹5,495 | 10,000 ₹10,000 |
| 7.00 | Supply , installation testing and commissioning isolator module for isolating short/dewired/loose circuit with automatic resetting arrangement isolator base can also proposed, however in that case needs to be considered with each detector & module , the device shall have an LED which sahll blink in normal stage and get steady on activation to monitor the health status of the device moduler shall be supplied with mounting plate from IEM for easeof installation and maint as specified as directed by Engineer in Charge.
Make Notifier Honeywell or any other equivalent . i.e CEASE Fire/EDWARD/Siemens | 1 | EACH | 4,699 ₹4,699 | 4,40,000 ₹4.4 L |
| 8.00 | Supply and fixing PVC insulated PVC unsheathed multistranded copper conductor cable of size FRLS cable 1.5 Sqmm 2 core as specified as directed by Engineer in Charge. | 20 | RUNNING METRE | 80 ₹1,600 | 80 ₹1,600 |
| 9.00 | M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed (1:4) in CM laid and jointed with grey cement slurry mixed pigment to match the shade of slab including rubbing and polishing complete all as specified as directed by Engineer in Charge. | 47.52 | SQURE METRE | 1,100 ₹52,272 | 900 ₹42,768 |
| 10.00 | Supply and fixing switch and socket combination 5 Amp 3/5 Pin combined all as specified as directed by Engr-in- charge | 2 | EACH | 337 ₹674 | 250 ₹500 |
Updated dates
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Dec 2025, 6:00 pmClosed
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station Jamnagar 361003
PROVN / IMPROVEMENT OF FIRE ALARM SYSTEM, ASSOCIATED WORKS AND CONSTRUCTION OF SPIKE NLOS WEPON SYSTEM INFRASTRUCTURE AT AF STN JAMNAGAR UNDER GE (AF) JAMNAGAR NO 1
2025_MES_740960_1
8384/E8
Open Tender
Miscellaneous Works
180 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹60,000
Yes
1 Jan 2026
21 Nov 2025
20 Dec 2025
21 Nov 2025
19 Dec 2025
5 Dec 2025
Amount
Supply , installation , testing and commissioning of microprocessor based 1 loop capacity analouge addressable fire alarm control panel with minimum 80 characters LCD display, 800 event plus, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spares capacity in each loop. Each loop shall have a capacity of minimum 300 analouge addressable device. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC Power supply, automatic battery charger , 2 x 12 Volts , 7 AH sealed lead acid batteries . Designed to meet UL 864 10th edition - 1 loop control panel with single mode fiber card High speed network communication module upto 25 KM (15.5 miles) between nodes using 9/125 micrometer single mode fiber.Model NFS-320 + HS NCM SF of Make Notifier/ Honeywel / Cease Fire/EDWARD/Siemens
Supply , installation , testing and commissioning of network control annuciator with 640 character display used to present event information from the network with alphanumeric QWERTY rubber keypad with tactile and audible feedback. Multiple passwords and access levels. Support digital voice command (DVC) for network audio application. UL/FM approved with single mode fiber card high spped network commucation module upto 25 KM (15.5 miles) between nodes using 9/125 micrometer single mode fiber as specified as directed by Engineer in Charge. Model NCA-2 ONYX + HS NCM SF Make Notifier Honeywell Cease Fire/EDWARD/Siemens/ Ravel
Supply and fix Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination photoelectirc/optical with base with self built intelligence , the detector should have group decision technology for faster responce & avoid false alarms, the detector shall have twin bi color LED for 360 degree viewing addressing shall be with user friendly roatary decimal switches designed to meet UL 268 7th edition as specified as directed by Engineer in Charge. Make Notifier Honeywell / Cease Fire/EDWARD/Siemens/Ravel
Supply , installation testing and commissioning of sounder cum strobe rated at 80 dBA @ 3m for audible and 115 cd flashing at 1Hz for visual indicaiton UL listed as specified as directed by Engineer in Charge. Make Notifier Honeywell or any other equivalent Make Notifier Honeywell / Cease Fire/EDWARD / Ravel/Siemens
Supply, installation and commissioning and testing of Addressable manual call point - Resettable type-with back box with binary coded address setting with status LED for 360 visibilty- IP 50 Rating as specified as directed by Engineer in Charge. Make Notifier Honeywell / Cease Fire/EDWARD/ Siemens/ Ravel
Supply, installation , testing and commissioning of addressable control module for sounder/strobes/sounder cum strobs . The control module shall provide supervised NAC output rated 24V DC 2A. The device shall have an LED whick blink in normal state and get steady on activation to monitor the health status of the device. Addressing shall be with user friendly rotary decimal switches, moduler shall be supplied with mounting plate from IEM for ease of installation and maint as specified as directed by Engineer in Charge. Make Notifier Honeywell/ Cease/ Fire/EDWARD/Siemens/Ravel
Supply , installation testing and commissioning isolator module for isolating short/dewired/loose circuit with automatic resetting arrangement isolator base can also proposed, however in that case needs to be considered with each detector & module , the device shall have an LED which sahll blink in normal stage and get steady on activation to monitor the health status of the device moduler shall be supplied with mounting plate from IEM for easeof installation and maint as specified as directed by Engineer in Charge. Make Notifier Honeywell or any other equivalent . i.e CEASE Fire/EDWARD/Siemens
Supply and fixing PVC insulated PVC unsheathed multistranded copper conductor cable of size FRLS cable 1.5 Sqmm 2 core as specified as directed by Engineer in Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed (1:4) in CM laid and jointed with grey cement slurry mixed pigment to match the shade of slab including rubbing and polishing complete all as specified as directed by Engineer in Charge.
Supply and fixing switch and socket combination 5 Amp 3/5 Pin combined all as specified as directed by Engr-in- charge
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of HT Cable and making good of disturbed surface to match with the existing surfaces by using new material i.e bitumen/PCC (1:3:6) type C-1 as specified as directed by Engineer in Charge.
Supply & laying 40 mm bore galvanised iron tubing light grade for protection of cable etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing as specified as directed by Engineer in Charge.
Supply and fixing connecting and testing optical fibre cable 6 core cat 6, Cable Type Armoured Loose Tube Jelly Filled (Multi-Tube), rodent resistant. Fiber Type Single Mode, 9 / 125, 250 micron primary coated buffers, Fiber Core As per Telecordia GR20, ITU-T G652D, IEC- 60793-2-50, TIA/EIA, 492-CAAB, No of Cores 12, Armouring Corrugated Steel Tape Armor, Cable Construction Type, BELLCORE GR 20 / IEC 794-1 - Loose tube Corrugated steel tape, (0.155mm Min)CSTA provided with FRP Rod as strength members, Outer Jacket Construction High density polyethylene, anti - termite, anti - rodent suitable, for direct burial application, @1310nm < = 0.35 dB/Km, @1500nm < = 0.20 dB/Km, Maximum Tensile Load >= 2670 N as specified as directed by Engineer in Charge. Make: D-link /Finolex/Legrand
Supply and laying HDPE 32mm dia pipe with 4 Kg/cm2 pressure with all fitting and accessories complete all as specified as directed by Engineer in Charge.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for manhole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified as directed by Engineer in Charge.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soil complete all as specified as directed by Engineer in Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified as directed by Engineer in Charge.
Supply , installation , testing and commissioning Fire alarm control panel complying with BS EN 54/UL listing Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified as directed by Engineer in Charge.
Supply, installation, testing and commissioning of Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 3500 mtr range complete all as specified as directed by Engineer in Charge. (Approved by LPCB/EN54)
S&F in replacement of Batteries DC , 12 V 7 AH lead acid duly initial charged complete all as specified as directed by Engineer in Charge. Make Exide/Amaron/Star Gold
Material & Labour for point wiring for one 15 Amp socket on Independent board controlled by one, one way switch complete with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC conduit of suitable size , including all accessories like bend, tees, junction boxes etc. including 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC terminal box of suitable size complete all as specified as directed by Engineer in Charge.
S&F Modular Switch one way one module 16 Amp complete all as specified as directed by Engineer in Charge.
Supply & Fixing Modular Socket outlet 3 pin, 6/16A, 3/5 pin two module complete all as specified as directed by Engineer in Charge.
Supply and fixing of stove enamelled black MS Conduit 20mm dia ISI marked on ceiling or recessed as required & repairing and making good the same disturbed surfaces and including taking down old unserviceable complete all as specified as directed by Engineer in Charge.
Supply and fix in repair PVC insulated PVC sheathed single core multistanded copper conductor cable of size 1.5 sqmm FRLS with PVC conduit of suitable size complete all as specified as directed by Engineer in Charge.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 2 core, 1100 Volts grade complete all as specified as directed by Engineer in Charge.
S&F of stainless steel mast of 38 to 40mm dia and length 3.0 mtr (approximate weidht 6.40Kg) fixed on roof slab/wall duly embedded in and including cement concrete (1:2:4) size 60x60x50cm complete for fixing mast inside the foundation complete all as specified as directed by Engineer in Charge.
S&F supporting tripods to fix lighting conductor or elevation mkasts to flat roofs including GI steel plate with bolts of dia 12mm , height 330mm , dimension of base plate 200 x 200mm inlcuding accessories complete all as specified as directed by Engineer in Charge.
S&F of Air termination with 5 spikes star pointed copper rod 15mm dia and 1500mm long and 100 micron copper bonded lightening conductor with base fixed in position on pole complete with clamp and nut bolts complete all as specified as directed by Engineer in Charge.
Supply and fix Copper earth strip of size 20 x 3 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block including taking down old strip complete all as specified as directed by Engineer in Charge.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC Casing capping of suitable size , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including modular cover sheet and PVC terminal box of suitable size to fix modular switch and sockets/fan regulators complete all as specified as directed by Engineer in Charge.
All as per item ser NO 1 here-in-above but for one 3 pin socket outlet, 5 Amps, independent board , with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 1.5 sq. mm size in and including PVC casing & capping of suitable complete all as specified as directed by Engineer in Charge.
S&F Modular Switch one way one module 6 Amp complete all as specified as directed by Engineer in Charge.
Supply & Fixing Modular Socket outlet 3 pin, 6A, 3/5 pin two module complete all as specified as directed by Engineer in Charge.
S&F in repairs energy efficient decorative ultra slim LED tube light fitting with built in LED & integral LED driver 22 watt, aluminium extruded channel (approximate length 1200 mm) housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified as directed by Engineer in Charge.
M & L in repair for Ceiling rose 3 pin flush type 6 Amps, 240 volts AC ISI marked complete all as specified as directed by Engineer in Charge.
S&F sheet metal enclosure , 63A triple pole and neutral with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one triple pole MCB 63 Amp fixed properly on in concealed position complete all as specified as directed by Engineer in Charge.
Supply and fixing copper earth strip of size 20 x 3.15mm with epoxy insulators and fixing screw etc for earth continuity conductors to test point terminal complete all as specified as directed by Engineer in Charge.
Supply, installation and testing Air cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C +,- 3 in cooling mode) Air conditoner as specified as directed by Engineer in Charge will have following conditons :- (a) Refrigerant - R-410 a/R-32 (b) EER- 5 Star Rating (c) Tonnage - 1.5 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote - As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments
S&F sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly on in concealed position complete all as specified as directed by Engineer in Charge. Make : Legrand/Schiender/ABB
Supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180V to 250V with voltage stabilzed at 230V with accuracy of (+, -) 2.5% and capacity 5 KVA complete all as specified as directed by Engineer in Charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply and fix MCCB triple pole and neutral DPX3 thermal magnetic capacity of 125 Amp 415 V and 16 KA complete all as specified as directed by Engineer in Charge.
Supply and fixing of MCBs single pole and neutral, 'C' Curve type capacity 40 Amps ,10KA & 240 Volts complete all as specified as directed by Engineer in Charge.
Supply and Fixing of MCB single pole, 'C' curve type capacity 6 to 32 Amps capacity complete all as specified as directed by Engineer in Charge.
Supply and fix in repair MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge including connecting.
S&F MCCB DB made out of sheet metal powder coated, factory made, enclousure double door type VTPN 4 way vertical type (suitable for incoming MCCB and outgoing MCB) with 250 Amps rated copper bus bar, neutral bar, earth bar, IP 43 & 54 with provision for MCCB as incomer and provn for SP/TP MCB as outgoing (without MCB/MCCB) on flush to the wall inlcuding making hole in the wall and fixing the DB including cement work and plastering complete all as specified as directed by Engineer in Charge.
Material & Labour for sub main wiring with 4 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 32 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with casing & capping will be measured as one RM for payment complete all as specified as directed by Engineer in Charge.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 50 sq mm complete all as specified as directed by Engineer in Charge.
Supply and fixing HDPE pipe suitable for 6 Kg/cm2 pressure of size 50/65mm dia complete all as specified as directed by Engineer in Charge.
Supply & laying 50 mm bore galvanised iron tubing light grade for protection of cable etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified as directed by Engineer in Charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified as directed by Engineer in Charge.
M&L for pre-cast cement concrete block masonry with solid blocks type c (1:3:6 20mm graded aggregate), exc. 10cm in width and setting in cement mortar (1:6), complete all as specified as directed by engineer in charge.
M & L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:4 complete all as specified as directed by Engineer in Charge.
M&L Moorum/ red bajri filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelling and rammed including watering complete all as specified as directed by Engineer in Charge.
M&L for hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified as directed by Engineer in Charge.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) complete all as specified as directed by Engineer in Charge.
rajengineers (BID ID -3494697)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
PS.pdf
Tender Documents • 0.83 MB
BOQ_829699.xls
BOQ • 2.47 MB
Download all tender documents and submit your bid