Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 CrAdmitted-Finance 916 9 AWAS VIKAS COLONY RISHIKESH | DEHRADUN | UTTARAKHAND | 248001 | ₹1.1 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S RAJ SHREE ELECTRICALS L1 | M/S R. B. ELECTRICALS L2 | KUMARS ASSOCIATES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Total amount of the "Rate Schedule" sheet | 1 | Nos | 1,09,96,059.01 ₹1.1 Cr | 1,13,06,983.19 ₹1.1 Cr | 1,18,29,372.25 ₹1.2 Cr |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
24 Jan 2026, 12:00 pmClosed
Superintending Engineer
Electricity Distribution Circle(R) 18 E C Road, Dehradun
Replacement of 11 KV Conductor by 11 KV AAAC AL-59, 99 sqmm. Covered conductor of 11 KV Haripurkalan feeder under EDSD, Raiwala under EDD, Rishikesh.
2026_UPCL4_90825_1
67/EDCRDDUN/2025-26
Open Tender
Electrical Works
120 days
Haripurkalan, Rishikesh
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,800
EE, ETD(R)
₹2.2 L
25 Mar 2026
9 Jan 2026
24 Jan 2026
9 Jan 2026
24 Jan 2026
12 Jan 2026
Total amount of the "Rate Schedule" sheet
SCHEDULE OF QUANTITY AND RATE FOR REPLACEMENT OF 11 KV CONDUCTOR BY 11 KV AAAC AL-59, 99 SQMM. COVERED CONDUCTOR OF 11 KV HARIPURKALAN FEEDER UNDER EDSD, RAIWALA UNDER EDD, RISHIKESH AGAINST E-TENDER SPECIFICATION NO.67/EDCRDDUN/2025-26
Name of The Bidder's Firm:
Part [A] (Supply Portion)
PP & Clamp with N&B ST Pole SP-55
Stay Clmap for SP-55 with Nut & Bolt
Stay Clmap for SP-33 with Nut & Bolt
PP & Clamp with N&B ST Pole SP-33
IPC with Aluminium Bail for Earthing
11 KV Cable Ties for Pin Insulator
11 KV IPC for Covered to Covered Connector
11 KV IPC for Covered to Bare Connector
11 KV Mid Span Jointing Kit
11 KV Tension Clamp with bail and IPC
11 KV AAAC AL-59, 99 sqmm Covered Conductor
Total - Part [A]
Part [B] (Labour Portion)
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual.
Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing.
Excavation of earth for Stay pit of size 0.6x0.6x1.2mtr in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
Erection of 11 KV Stay set with Pole & Stay rod on required tension as pe drawing/RESPO manual
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand) block including cost of Cernent, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO Manual.
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
Erection of Single support poles SP-33 in proper level and alignment along with fixing of all accessories. Like top channel & clamps as per RESPO construction Manual.
Erection of Single support poles SP-55 in proper level and alignment along with fixing of all accessories. Like top channel & clamps as per RESPO construction Manual.
Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio1:4:8 (1 cement: 4 graded stone 20 mm nomial size :8 coarse sand) block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO construction Manual.
Muffing of Poles size 0.45cm x0.60 cm radious with cc1:3:6 (1 cement:3 coarse sand : 6 graded stone 10 mm nomial size) block and 45 cm height from ground level inculding cost of blast, cement and sand etc.
Dismantling of Guarding in 11 KV line
Painting of ST Pole SP- 33 with angle and channel and all steel part by one cost of Red Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
Painting of ST Pole SP- 55 with angle and channel and all steel part by one cost of Red Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
Erection of Bracket in 11 KV line
Guarding of line over (Telephone/Road/LT line crossing as per drawing with 6/8 SWG G.I. wire including fixing of guarding channel/angle as per RESPO manual LT/11 KV
T-off connection complete 11 KV line
Making of Section pole for existing 11 KV line complete in all respect
Cartage of ST Pole SP-33 from store centre to construction sIte with loading, unloading at both points and proper stacking. Approx distance 51-70 Km.
Cartage of ST Pole SP-55 from store centre to construction sIte with loading, unloading at both points and proper stacking. Approx distance 51-70 Km.
Cartage of other material (other than poles) by vehicle from store centre to nearest construction site store including loading and unloading at both ends. Approx distance 51-70 Km.
Head load Cartage of ST Pole SP-33 poles from road side to construction site. Approx distance 0-1 KM.
Head load Cartage of ST Pole SP-55 poles from road side to construction site. Approx distance 0-1 Km.
Head load cartage of small material. Rate are per Km/Qunital inculding loading and unloading. Approx distance 0-1 Km.
Re-erection of Fencing and Gate from including Fabrication cutting and welding works
Disconnection and Reconnection of existing service connections by Loop jumpering on main line through catenary wire 12 SWG and eye rag bolt at consumer premise including supply of catenary wire and eye rag bolt in size 150x12 mm as per RESPO schedule
Dismantling & Reinstall of Street Light
Straightening of tilted/Inclined ST Pole with proper Binding & Jumpering
Tightening loose, Old stay after straightening the tilted pole & loose line
Resagging of LT AB Cable
Sagging/Resagging of ACSR/AB Cable LT line
Back Cartage of Petty material by vehicle from Road site to store centre including loading and unloading. Approx distance 0-20 Km.
Painting of Double Pole Structure of ST Pole SP-23/33
Painting of Double Pole Structure of ST Pole SP-55/72
Removing of damage wire and dressing from existing line
Fixing of IPC with Aluminium bail for earthing
Dismantling and Restringing of LT AB Cable
Opening and Making of Jumper of Section Pole after complete the work
Fixing of Channel, Angle on Pole
Fixing of 11 KV 90 KN Tension Clamp B&IPC
Fixing of 11 KV Mid Span Jointing Kit
Back Head load Cartage of petty material from nearest construction site to road site including loading and unloading. Approx distance 0-1 km
Fixing of 11 KV IPC for Covered to Covered Conductor
Fixing of 11 KV IPC for Covered to Bare Connector
Grouting and Muffing of existing old poles at site
Laying Spreading, Stringing and Sagging of 11 KV AAAC line in 3 phase including proper binding and jumpering as per prevailing norms.
Fixing of 11 KV Cable Ties for Pin Insulator
Removing old conductor by opening jumper from existing site
Lopping and Chopping of Tree Branches
Painting of old existing Pole from site
Total - Part [B]
TOTAL [Part-(A) + Part (B)]
Place
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
TenderDocument.pdf
Tender Documents • 1.25 MB
TechSpecofAAAC.pdf
Other Document • 0.96 MB
ImportantNotice.pdf
Other Document • 0.08 MB
GTPofAAAC.pdf
Other Document • 0.26 MB
BOQ_107623.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid