Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAdmitted-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | ₹41.5 L | L1 | Admitted-Finance |
| 2 | L2₹42.7 LAdmitted-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹42.7 L | L2 | Admitted-Finance |
| 3 | L3₹44.8 LAdmitted-Finance | ₹44.8 L | L3 | Admitted-Finance |
| 4 | L4₹44.8 LAdmitted-Finance | ₹44.8 L | L4 | Admitted-Finance |
| 5 | L5₹45.4 LAdmitted-Finance OLD MISSAMARI PO PS MISSAMARI DISTT SONITPUR ASSAM PIN 784506 | SONITPUR | ASSAM | 784506 | ₹45.4 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Raj Enterprise L1 | Anil Kumar Sarmah L2 | M/s Brahamaputra Wood Industries L4 | MAHANTA ENTERPRISES L6 | M/S TANISHQ CONSTRUCTIONS L5 | M/S L N ENTERPRISE L7 | M/S RSB ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Servicing for DG set of capacity 62.5 KVA by replacing the following accessories to ensure its satisfactory performance complete all as specified and directed by Engnr-in-charge :
(a) Replacement of suitable grade Engine Oil and coolant
(b) S&F Oil filter, fuel filter and Air filter
(c) S&F water separator
(d) Radiator cleaning with chemical
(e) S&F change of fuel pipe
(f) S&F change of fan belt size
(g) S&F change of hose pipe with clamp | 3 | Each Job | 27,000 ₹81,000 Lowest | 30,000 ₹90,000 | 28,600 ₹85,800 | 33,600 ₹1,00,800 | 32,500 ₹97,500 | 30,000 ₹90,000 | 32,400 ₹97,200 |
| 2.00 | Description all as per items No 01 here-in-before but DG set of capacity 50 KVA complete all as specified and directed by Engnr-in-charge. | 3 | Each Job | 22,000 ₹66,000 Lowest | 25,000 ₹75,000 | 25,000 ₹75,000 | 31,200 ₹93,600 | 29,500 ₹88,500 | 26,000 ₹78,000 | 25,600 ₹76,800 |
| 3.00 | Description all as per items No 01 here-in-before but DG set of capacity 40 KVA complete all as specified and directed by Engnr-in-charge. | 4 | Each Job | 19,500 ₹78,000 Lowest | 23,500 ₹94,000 | 24,000 ₹96,000 | 28,400 ₹1,13,600 | 26,500 ₹1,06,000 | 24,000 ₹96,000 | 24,000 ₹96,000 |
| 4.00 | Description all as per items No 01 here-in-before but DG set of capacity 30 KVA complete all as specified and directed by Engnr-in-charge. | 1 | Each Job | 16,500 ₹16,500 Lowest | 23,000 ₹23,000 | 22,700 ₹22,700 | 27,150 ₹27,150 | 24,500 ₹24,500 | 22,000 ₹22,000 | 23,900 ₹23,900 |
| 5.00 | Description all as per items No 01 here-in-before but DG set of capacity 12.50 KVA complete all as specified and directed by Engnr-in-charge. | 1 | Each Job | 16,000 ₹16,000 Lowest | 21,000 ₹21,000 | 20,800 ₹20,800 | 24,700 ₹24,700 | 22,500 ₹22,500 | 20,000 ₹20,000 | 22,700 ₹22,700 |
| 6.00 | Description all as per items No 01 here-in-before but DG set of capacity 7.50 KVA complete all as specified and directed by Engnr-in-charge. | 1 | Each Job | 14,500 ₹14,500 Lowest | 19,500 ₹19,500 | 20,500 ₹20,500 | 24,600 ₹24,600 | 21,500 ₹21,500 | 18,000 ₹18,000 | 21,000 ₹21,000 |
| 7.00 | Supply only Engine Oil Grade 20W 40, performance level of API CF, IS: 13656-2002, EDL-2, SAE 20W-40 for DG Sets complete all as specified and directed by Engnr-in-charge. | 60 | Litre | 600 ₹36,000 | 580 ₹34,800 Lowest | 665 ₹39,900 | 662 ₹39,720 | 645 ₹38,700 | 750 ₹45,000 | 617 ₹37,020 |
| 8.00 | Supply only of Coolant suitable for DG Sets complete all as specified and directed by Engnr-in-charge. | 40 | Litre | 140 ₹5,600 Lowest | 175 ₹7,000 | 177 ₹7,080 | 168 ₹6,720 | 162 ₹6,480 | 300 ₹12,000 | 183 ₹7,320 |
| 9.00 | S&F in repair/replacement of radiator, blockages, leakage, fins etc of DG set of any capacity complete all as specified and directed by Engnr-in-charge. | 4 | Each Job | 14,500 ₹58,000 | 14,800 ₹59,200 | 14,300 ₹57,200 | 13,200 ₹52,800 Lowest | 14,100 ₹56,400 | 19,000 ₹76,000 | 15,100 ₹60,400 |
| 10.00 | S&F in repair/replacement of 'V' belts as per the sample of OEM suitable for DG Sets of any capacity complete all as specified and directed by Engnr-in-charge. | 5 | Each Job | 1,050 ₹5,250 Lowest | 1,080 ₹5,400 | 1,280 ₹6,400 | 1,430 ₹7,150 | 1,320 ₹6,600 | 1,300 ₹6,500 | 11,700 ₹58,500 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
9 Jun 2026, 6:00 pmClosed
GE NORTH TEZPUR
GE(North)Tezpur Solmara PO-Dekargaon Dist - Sonitpur Assam - 784501
REPAIR/PEPLACEMENT OF SOLAR WATER HEATERS, DG SETS INCLUDING PANELS AND ALLIED WORKS AT AGE CHARDUAR AREA UNDER GE (N) TEZPUR
2026_MES_766161_1
GE(N)/TEZ/2026-27/8278
Open Tender
Civil Works
Works
180 days
GE NORTH TEZPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE NORTH TEZPUR
₹84,000
Yes
19 Jun 2026
18 May 2026
11 Jun 2026
18 May 2026
9 Jun 2026
2 Jun 2026
18 May 2026 - 2 Jun 2026
M&L for winding of armature winding and field winding with super enamelled copper wire of appropriate gauge including varnishing with insulating material and heating up, testing etc, complete for DG set of capacity 40 to 62.5 KVA including taking out the old burnt copper windings from DG complete all as specified and directed by Engnr-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft/loose soil for foundation, laying of cables/ GI pipes etc. complete all as specified and directed.
Returning filling in, soft/loose soil including spreading leveling watering and ramming in layers of n.exc 25cm complete all as specified and directed.
Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed.
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 70 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 95 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 150 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 50 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
M&L for online centrifuging (filtration/ dehydration) of steplizer oil including checking di-electric strength of oil before and after filtration for steplizer with suitable machine having filtration, heating and pumping facility to improve the dielectric strength/ insulation value of oil complete all as specified and directed Engineer-in-charge.. Notes :- (i) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min. (ii) The contactor shall take shut down orders in writing from Engineer-in-charge before commencement of the work. (iii) The contractor shall ensure no wastage of stepliser oil. (iv) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge.
Supply and filling new transformer oil for topping up the steplizer duly filtered with filtration plant having dielectric strength not less than 60 KV complete all as specified and as directed. Note :- (a) The steplizer oil shall be confirming to IS - 335/1983. (b) Mineral oil grade shall be used. (c) The IR value of transformer oil shall not be less than 60KV/min. (d) The unit rate shall be deemed to include the cost of filtration to achieve desired di-electric strength.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
BOQ_858064.xls
BOQ • 2.23 MB
TenderDocument8278.pdf
Tender Documents • 1.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].