Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 CrAccepted-AOC UTTARPARA | ₹8.9 Cr | L1 | Accepted-AOC AOC |
Tender Value
Refer Docs
EMD Value
₹18 L
Closing Date
2 Dec 2020, 6:00 pmClosed
Chairpersion , BOA , Ashokenagar Kalyangarh Munici
ASHOKENAGAR KALYANGARH MUNICIPALITY ,P.O. AND P.S. ASHOKENAGAR, NORTH 24 PARGANAS ,743222
Planning, Survey, Design, Construction and Commissioning of 2790 Cum. capacity Clear Water Reservoir
2020_MAD_304038_1
IGLR-2ND-CALL
Open Tender
CIVIL WORKS
Item Rate
365 days
Ashokenagar Kalyangarh Municipality
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹18 L
Yes
uperintending Engineer, East Circle
28 Dec 2021
9 Nov 2020
4 Dec 2020
9 Nov 2020
2 Dec 2020
9 Nov 2020
13 Nov 2020
Amount
Planning, Survey, Design, Construction and Commissioning of 2790 Cum. capacity Clear Water Reservoir (TWL of CWR will be 1.00 metre above H.F.L.), related Clear Water Pumping Station and HT Sub-Station along with all other allied works (Civil & Electro-mechanical works & others, if any) at Ashokenagar- Kalyangarh (including 3 months trial run and necessary training of maintenance staff & thereafter (subsequently) 5 (five) year operation and maintenance of the entire scheme) with security and guarding arrangement for Water Supply Scheme under AMRUT within Ashokenagar- Kalyangarh Municipality on Turnkey Basis. Surveying, Planning, Designing, Construction of 2790 Cum. Capacity Clear Water Reservoir (TWL of CWR will be 1.00 metre above H.F.L.), related Clear Water Pumping Station with approximate discharge of 292 m3/hr & 227 m3/hr at required head (approximately 70m & 40m of water column) consisting of the building itself, all sorts of pumps, motor, valves, DJs, actuators, pipes, expanders/reducers, air valves, flow meters, pressure gauges, cables, panels, desks etc crane at pump house, Sub-Station consisting of the building itself, HT panel, 2 nos 11kV/433 or 415V transformers (approximate rating of 500kVA), MV/LT panel, control panel, required DC source, APFC panel etc along with all other allied works (Civil & Electro-mechanical work & others) according to I/E rules like all sorts of panels, cables, trays, joints, terminations, earthing systems, fire fighting systems, illumination systems, ventilation systems etc with all sorts of pile foundation etc related to the project in all respects at Ashokenagar- Kalyangarh with Retaining wall, boundary wall and other allied works etc, giving necessary training of maintenance staff including electrical works with the provisions for receiving power from WBSEDCL and 3(three) months trial run (after satisfactory completion-commissioning) and thereafter 5 (five) years operation and repairing-maintenance (supplying all sorts of materials, manpower etc) with guarding arrangement for proper safety and security on turnkey basis, as per the NIT and direction of the engineer-in-charge, under AMRUT. Laying of delivery lines from common delivery manifolds by the bidder will be upto 5.0 (five) meter (approx) from outside the boundary wall for each route provided with necessary valves as per the NIT and direction of the engineer-in-charge, Also, laying of delivery lines from the Delivery Point of PHE by the bidder will be upto 60.0 (Three Hundred only) meter (approx) from outside the boundary wall provided with necessary valves as per the NIT and direction of the engineer-in-charge. RCC Box Culvert over the drainage in the approach road to CWR Site will have to be constructed by the bidder
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .