| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.4 L+₹67,165 (2.95%)Rejected-AOC | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹23.4 L+₹71,030 (3.12%)Rejected-AOC | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹25.3 L+₹2.6 L (11.4%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹25.8 L+₹3.1 L (13.5%)Rejected-AOC | L5 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Srinivasa Consructions L7 | Universal refrigeration and Engineering Company L4 | Shreshta Associates L1 | Sri Balaji Enterprises L5 | SUN LIGHT HOUSE L3 | B SRINIVAS L8 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L6 | SRI SAI RAM ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge. | 1,625 | Point | 20 ₹32,500 | 5 ₹8,125 Lowest | 5 ₹8,125 Lowest | 10 ₹16,250 | 10 ₹16,250 | 25 ₹40,625 | 15 ₹24,375 | 5 ₹8,125 Lowest |
| 2.00 | Disconnecting and removing the MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of un serviceable spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified & directed by Eng- in Charge. | 48 | Each | 30 ₹1,440 | 10 ₹480 Lowest | 15 ₹720 | 10 ₹480 Lowest | 10 ₹480 Lowest | 250 ₹12,000 | 15 ₹720 | 10 ₹480 Lowest |
| 3.00 | Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge. | 510 | RM | 2 ₹1,020 Lowest | 5 ₹2,550 | 5 ₹2,550 | 5 ₹2,550 | 5 ₹2,550 | 25 ₹12,750 | 10 ₹5,100 | 5 ₹2,550 |
| 4.00 | M&L Concealed point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed.
Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. | 315 | Point | 1,000 ₹3,15,000 | 635 ₹2,00,025 | 600 ₹1,89,000 | 650 ₹2,04,750 | 600 ₹1,89,000 | 350 ₹1,10,250 Lowest | 650 ₹2,04,750 | 650 ₹2,04,750 |
| 5.00 | All as per Item No. 4 above, but one light point controlled by two way switches. | 35 | Point | 1,100 ₹38,500 | 655 ₹22,925 | 600 ₹21,000 Lowest | 650 ₹22,750 | 670 ₹23,450 | 850 ₹29,750 | 650 ₹22,750 | 650 ₹22,750 |
| 6.00 | All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . | 85 | Point | 1,000 ₹85,000 | 635 ₹53,975 | 600 ₹51,000 Lowest | 650 ₹55,250 | 600 ₹51,000 Lowest | 650 ₹55,250 | 650 ₹55,250 | 650 ₹55,250 |
| 7.00 | All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. | 50 | Point | 300 ₹15,000 | 120 ₹6,000 Lowest | 200 ₹10,000 | 195 ₹9,750 | 300 ₹15,000 | 700 ₹35,000 | 250 ₹12,500 | 180 ₹9,000 |
| 8.00 | All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor Note: Modular cover plate with frame and modular metal flux box and cutting/chases included in the rate quoted. | 50 | Point | 1,200 ₹60,000 | 715 ₹35,750 | 750 ₹37,500 | 690 ₹34,500 | 850 ₹42,500 | 585 ₹29,250 Lowest | 750 ₹37,500 | 850 ₹42,500 |
| 9.00 | M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed.
Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. | 250 | Point | 900 ₹2,25,000 | 615 ₹1,53,750 | 540 ₹1,35,000 | 650 ₹1,62,500 | 550 ₹1,37,500 | 380 ₹95,000 Lowest | 625 ₹1,56,250 | 550 ₹1,37,500 |
| 10.00 | All as per Item No. 9 above, but one light point controlled by two way switches. | 45 | Point | 1,000 ₹45,000 | 635 ₹28,575 | 540 ₹24,300 Lowest | 650 ₹29,250 | 600 ₹27,000 | 700 ₹31,500 | 625 ₹28,125 | 550 ₹24,750 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
10 Dec 2025, 6:00 pmClosed
Shri Rajesh Kumar Meena, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION DB FITTINGS AND FIXTURES AND CONNECTED WORKS AT OTM ACCN OF ZONE G AREA UNDER AGE EM (N) OF GE (NORTH) SECUNDERABAD
2025_MES_740514_1
8952
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer North Secunderabad
₹76,000
Yes
27 Jan 2026
19 Nov 2025
17 Dec 2025
19 Nov 2025
10 Dec 2025
3 Dec 2025
Amount
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge.
Disconnecting and removing the MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of un serviceable spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified & directed by Eng- in Charge.
Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge.
M&L Concealed point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 4 above, but one light point controlled by two way switches.
All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor Note: Modular cover plate with frame and modular metal flux box and cutting/chases included in the rate quoted.
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 9 above, but one light point controlled by two way switches.
All as per Item No. 9 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 9 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 9 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC casing caping medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note : Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 14 above, but one light point controlled by two way switches.
All as per Item No. 14 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 14 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 14 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic existing PVC conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/ sockets/ fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 19 above, but one light point controlled by two way switches.
All as per Item No. 19 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 19 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 19 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
S & F Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed.
S & F Modular switch 2 way 6/10 Amps, 1 Module complete all as specified and directed.
S & F Modular switch 1 way 16/20 Amps, 1 Module complete all as specified and directed.
S&F Modular Bell Push 10A, 1 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed.
S & F Modular ceiling fan regulator stepped type heavy duty suitable for BLDC fan to work on 230 volts, 2 Module complete all as specified & directed.
S & F Switch piano single pole flush type 5 amps, 230 volts complete all as specified and directed.
S&F Bell push 5 A flush type complete all as specified and directed.
S&F Socket outlet flush type multipurpose 2 in 1, 5 Pin, 5 amps, 230 volts complete all as specified and directed.
S & F Switch socket combination flush type multipurpose 2/5 pin 5 amps 2 in 1 230 Volts complete all as specified and directed.
S & F Switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type with complete all as specified and directed.
S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
S & F Electronic type regulator stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and directed.
S & F Angle holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and directed.
S&F Bell ding dong working on 230 volts AC Supply complete all as specified and directed.
S&F in replacement of Surface mounted Downlighter 15W with ABS housing and PC Opal diffuser with integral electronic LED driver complete with all accessories complete all as specified and directed.
S&F Round shape 12 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories all as specified and directed by Engg-in-Charge.
S&F LED Tube Rod 1 x 20 W 4feet, 230V complete with 2 Nos round blocks for mounting arrangements all as specified and directed by Engr-in-Charge.
S&F in replacement recess mounting with perforated sheet with electronic driver luminaire 34/35/36 watts LED slim panel (2'x2') 220v, upto 150 lumen/watt, 50,000 burning hrs, UGR<19 with central opal diffuser series mounted in grid ceiling surfaces and suitable hanging provision where required including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S&F in replacement surface mounting with perforated sheet with electronic driver luminaire 34/35/36 watts LED slim panel (2'x2') 220v, upto 150 lumen/watt, 50,000 burning hrs, UGR<19 with central opal diffuser series mounted in grid ceiling surfaces and suitable hanging provision where required including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S&F in replacement of wall mounted 4' LED batten 20w,230v, 120 lumen/watt, 50,000 burning hrs, THD<10% and polycarbonate housing & integrated electronic drive etc.complete with all accessories internally pre-wired with 2 Nos round blocks for mounting arrangements and including connecting up with 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with suitable size all as specified and directed by Engr-in-Charge
S&F in replacement wall mounted 2 feet LED Batten, extruded powder coated aluminum housing heat sink provided for efficient heat dissipation & intergated electronic driver 1x10W, 230 Volts, 50,000 burning hrs, THD<10% , DIFFUSED TYPE connector block, internally pre wired etc including new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting all as specified and as directed.
S&F in replacement of LED security Light luminaire 25 watts with deep drawn housing including all accessories and Lamp, with suitable pipe bracket 25 mm dia 0.60 Mtr length fixed on wall with suitable flat iron clamps and nut bolts complete all as specified and directed.
S&F in replacement of LED Bulb 9/10/12 watts 5 star BEE all as specified and as directed.
S&F in replacement of Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10W edge-lit LED luminaire comprising of high brightness LEDs including taking down unserviceable fitting all as specified and directed.
S&F in replacement of Wall light including 9 Watt LED Bulb, Environmental friendly, ultra modern, energy saving, surface mounted complete all as specified and directed.
Supply and fix in replacement of MCB SP 6 to 32 Amps 240 volts, 'B' curve for fixing on MCB DB's complete all as specified and directed.
S & F in replacement of MCB SPN 40 to 63 Amps 240 'C' curve volts for fixing on MCB DB's complete all as specified and directed.
S & F in replacement of MCB Four pole, 415 volts, 'C' curve suitable for fixing on MCB DB of capacity 40 to 100 Amps complete all as specified and directed.
S & F in replacement of MCB TP 25 to 63 Amps 240 'C' curve volts for fixing on MCB DB's all as specified and as directed.
S & F Sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified
All as per Item No 55 above, but MCB DB SPN 12 way
S & F in replacement of Horizontal type TPN DB 4 way double door made out of CRCA sheet housing with powder coating & confirming to IS 13032, IS 8623, BS 5486 accommodated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated complete all as specified and directed.
All as per Sl item No 57 above, but VTPN 4 way DB
S & F in replacement of Modular Single pole and Neutral enclosure (Modular AC Box) with a two pin and earth plug and socket complete with one single pole MCB 25 Amps (AC Box) complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated sheathed multistranded FRLS 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 2.5 sqmm PVC insulated sheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note: 3 runs of 2.50 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
All as per Item No 60 above, but 2 runs of single core 4 sqmm and one run of single core 4 sqmm as earth continuity conductor. Note: 3 runs of 4 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
All as per Item No 60 above, but 4 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuity conductor. Note: 5 runs of 6 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm complete all as specified and directed.
S&F in repairs MCCB Four pole, 415 volts of capacity 100 Amps, 25KA suitable for fixing on MCCB DB complete all as specified and directed.
S&F in replacmenet of Rigid non-metallic PVC conduit 20 mmexclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed.
S& F Modular white cover plate with frame 1 Module,240V,ISI marked complete all as specified and directed.
S& F Modular white cover plate with frame 2 Module,240V,ISI marked complete all as specified and directed.
S& F Modular white cover plate with frame 3 Module,240V,ISI marked complete all as specified and directed.
S& F Modular white cover plate with frame 4 Module,240V,ISI marked complete all as specified and directed.
S& F Modular white cover plate with frame 6 Module,240V,ISI marked complete all as specified and directed.
S& F Modular white cover plate with frame 8 Module,240V,ISI marked complete all as specified and directed.
S& F Modular white cover plate with frame 12 Module,240V,ISI marked complete all as specified and directed.
S& F Modular metal box 1 and 2 Module,240V,ISI marked complete all as specified and directed.
S& F Modular metal box 3 Module,240V,ISI marked complete all as specified and directed.
S& F Modular metal box 4 Module,240V,ISI marked complete all as specified and directed.
S& F Modular metal box 6 Module,240V,ISI marked complete all as specified and directed.
S& F Modular metal box 8 Module,240V,ISI marked complete all as specified and directed.
S& F Modular metal box 12 Module,240V,ISI marked complete all as specified and directed.
S&F Modular Surface Mounting Boxes 1 and 2 Module complete all as specified and directed.
S&F Modular Surface Mounting Boxes 3 Module complete all as specified and directed.
S&F Modular Surface Mounting Boxes 4 Module complete all as specified and directed.
S&F Modular Surface Mounting Boxes 6 Module complete all as specified and directed.
S&F Modular Surface Mounting Boxes 8 Module complete all as specified and directed.
S&F Modular Surface Mounting Boxes 12 Module complete all as specified and directed.
SRI SAI RAM ENTERPRISES (BID ID -3500905)
SUN LIGHT HOUSE (BID ID -3494624)
Universal refrigeration and Engineering Company (BID ID -3493968)
Sri Balaji Enterprises (BID ID -3494619)
THE DECAN ENGINEERING AND REFRIGERATION COMPANY (BID ID -3499381)
Srinivasa Consructions (BID ID -3493867)
B SRINIVAS (BID ID -3497496)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_829203.xls
BOQ • 0.54 MB
tender8952.pdf
Tender Documents • 1.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .