| Sl No | Description | Qty | Unit | D SURESH L2 | Seven Seas Infotech Systems L3 | Best Power Controls L1 |
|---|---|---|---|---|---|---|
| 1.00Electrification | ||||||
| 1.00 | OD97602/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 5 KVA, Single phase in and single phase out UPS with zero transfer time, DSP based control , IGBT rectifier and IGBT inverter, provision for enhancing UPS capacity by operating UPS in N+X parallel (Up to 4 systems), RS232 port, input PF> 0.99@ full load, unity output PF (5KVA=5KW), input voltage range 160V- 280V with auto cut off, THD </= 10%, overall efficiency (AC to AC) >/= 94% , Display panel (in-built LCD and LED) with all measurements and fault indication and LED indications, Audible alarms for: "replace battery, overload warning and shutdown, Low battery, High temperature warning and shutdown". Suitable for operation in 0-40 degree Celsius ambient Temperature with a noise level<50 dbA at 1m distance and noise level should reduce with load., Generator compatibility, pure sine wave , Battery overcharge and undercharge cut off , Cold start, Automatic restart, self diagnosis, Automatic Bypass arrangement. The UPS system shall include necessary parallel kit and all battery accessories including MS open racks complete with interconnections. The system shall comply with IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS and relevant IS standards. All relevant type test certificates shall be provided and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. UPS Make : Delta, Legrand- Numeric, Hykon or equivalent make) , Battery Make : Exide EL / Amaron Quanta, c10 Battery suitable for a minimum VAH of 15840 | 7 | each | 2,49,000 ₹17,43,000 | 2,60,000 ₹18,20,000 | 2,44,400 ₹17,10,800 Lowest |
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 250 | metre | 104 ₹26,000 Lowest | 105 ₹26,250 | 110 ₹27,500 |
| 1.00 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | 100 | metre | 198 ₹19,800 Lowest | 205 ₹20,500 | 210 ₹21,000 |
| 1.00 | 1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm | 25 | metre | 313 ₹7,825 Lowest | 323 ₹8,075 | 350 ₹8,750 |
| 1.00 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | 250 | metre | 333 ₹83,250 | 315 ₹78,750 Lowest | 350 ₹87,500 |
| 1.01 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 50 | metre | 150 ₹7,500 | 85 ₹4,250 Lowest | 160 ₹8,000 |
| 1.01 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 500 | metre | 140 ₹70,000 Lowest | 140 ₹70,000 Lowest | 140 ₹70,000 Lowest |
| 1.01 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 125 | metre | 155 ₹19,375 Lowest | 160 ₹20,000 | 165 ₹20,625 |
| 1.01 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module | 35 | each | 200 ₹7,000 | 175 ₹6,125 Lowest | 210 ₹7,350 |
Tender Value
₹22.8 L
EMD Value
₹50,000
Closing Date
17 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
O/o Executive Engineer, PWD Electrical Division , PMG , Near planetaurium,695033
GENERAL Revenue UPS Attingal Section Phase II Providing UPS facilities to Revenue Offices Varkala Thaluk 7 village offices-SITC of UPS-General Electrical Work
2025_PWD_775549_1
EDT_ET_20_2025_26
Open Tender
Electrical Works
Item Rate
120 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
1 Sept 2025
8 Jul 2025
21 Jul 2025
8 Jul 2025
17 Jul 2025
8 Jul 2025
Amount
Electrification
OD97602/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 5 KVA, Single phase in and single phase out UPS with zero transfer time, DSP based control , IGBT rectifier and IGBT inverter, provision for enhancing UPS capacity by operating UPS in N+X parallel (Up to 4 systems), RS232 port, input PF> 0.99@ full load, unity output PF (5KVA=5KW), input voltage range 160V- 280V with auto cut off, THD </= 10%, overall efficiency (AC to AC) >/= 94% , Display panel (in-built LCD and LED) with all measurements and fault indication and LED indications, Audible alarms for: "replace battery, overload warning and shutdown, Low battery, High temperature warning and shutdown". Suitable for operation in 0-40 degree Celsius ambient Temperature with a noise level<50 dbA at 1m distance and noise level should reduce with load., Generator compatibility, pure sine wave , Battery overcharge and undercharge cut off , Cold start, Automatic restart, self diagnosis, Automatic Bypass arrangement. The UPS system shall include necessary parallel kit and all battery accessories including MS open racks complete with interconnections. The system shall comply with IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS and relevant IS standards. All relevant type test certificates shall be provided and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. UPS Make : Delta, Legrand- Numeric, Hykon or equivalent make) , Battery Make : Exide EL / Amaron Quanta, c10 Battery suitable for a minimum VAH of 15840
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
OD81873/2025-2026:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40 A 2 pole Isolator complete with connections, testing and commissioning etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD97044/2025-2026:Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
OD97052/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required.
D SURESH (BID ID -2253935)
Seven Seas Infotech Systems (BID ID -2253969)
Bidder Name
D SURESH
Seven Seas Infotech Systems
Best Power Controls
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .