DC SHARMA
CWE (NW) KOCHI
ADDN/ALTN TO CRASH CREW ROOM, CTI ROOM, ATC STORE, PROVN OF PAVER BLOCK BEHIND ATC BUILDING AT INS GARUDA, SPECIAL REPAIRS TO OLD HPMV FITTINGS TO LED FLOOD LIGHT/HIGHBAY LIGHT AT NSRY, NAVAL BASE KOCHI AND ADDN/ALTN TO FLOORING OF UTILITY AREA AT VA
2022_MES_567629_1
CWE(NW)/KOCHI/81321
Open Tender
Civil Works
Item Rate
270 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (NW) KOCHI
₹90,000
Yes
28 Jan 2023
6 Dec 2022
5 Jan 2023
6 Dec 2022
3 Jan 2023
20 Dec 2022
Amount
Dismantling of wall and ceiling boards (fiber, pulp insulation etc.) or insulation boards / slabs / blankets, any thickness including fillet complete all as specified and as directed.
S & F 605 x 605 mm size at any height of grid Anodised aluminium snap grid frame work for false ceiling complete all as specified and directed.
S & F Hangers at any height6 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60 mm long complete all as specified and directed.
S & F 4 mm thick Non asbestos fibre cement buliding boards at any height fixed or laid / inserted to timber / GI / Aluminium frame work with screws in ceiling flat or sloping complete all as specified and directed.
M & L for preparation of new perforated board surfaces and applying one coat of oil bound distemper over a coat of primer complete on walls.
S & F of 2nd class hard wood plain fillets of area exc 13 and n.exc. 25 sqcm, square, rectangular or traingular in section clean sawn, secured with screw fixed to walls complete all as specified and directed.
M & L for preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with one coat of cereosite oil complete all as specified and as directed.
M & L for 12 mm thick perforated particle board/tiles for insulation and accoustic purposes 60 x 60 cm in size fixing with flat screw in wooden fillets in walling complete all as specified and directed.
M & L for 40 mm thick bonded mineral wool blanket slab made from glass density 24 kg/cum and fixed as per manufacturer's instruction complete all as specified and as directed.
Dismantling of timber fillet, rail, post, rafters, purlins etc. under 40 sqm in section in framed work complete all as specified and directed.
S & F of 2nd class soft wood plain fillets of area exc 3 and n.exc. 6 sqcm, square, rectangular or traingular in section clean sawn, secured with screw fixed to walls complete all as specified and directed.
Taking down cement or cement lime plaster from brick work or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M & L for 10 mm thick plaster on other than fair faces of brick work or concrete surfaces cement mortar 1:6, finished even and smooth complete all as specified and directed.
M & L for 5 mm thick plaster on other than fair faces of brick work or concrete surfaces cement mortar 1:3 in ceiling finished and smooth complete all as specified and directed.
M&L for preparation of new surfaces and applying three coats of white wash complete on ceilings complete all as specified and as directed.
M&L for preparation of new decorated surfaces of walls including cornices (plastered or unplastered) and applying two coat of distemper oil emulsion over alkali resistant primer all as specified and directed .
M&L for preparation of old decorated surfaces of walls including cornices (plastered or unplastered) and applying one coat of distemper oil emulsion all as specified and directed .
Taking down chowkats or frames with shutters (without taking off shutters from the frame)exc 1.5 sqm but not exc 4 sqm each complete all as specified and as directed.
S&F for powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc.(minimum thickness of powder coating 50 micron) complete all as specified and as directed.
S&F for powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc..(minimum thickness of powder coating 50 micron) complete all as specified and as directed.
M&L for 5.50 mm thick tinted sheet glass, ordinary quality and glazing in square Exc 0.50 sqm in each Pane complete all as specified and as directed.
M&L for 12 mm thick Prelaminatd particle board, exterior grade, prelaminated both side with decorative choice lamination with screws to timber frame work complete all as specified and as directed.
M & L for preparation of old wooden surfaces of any description, exc. 10 cm width of girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish of premises complete all as specifeid and directed.
M & L for 10 mm thick screed bed or bedding layer in cement mortatr 1:4 for laying floor finishes finished even and rough suitable for laying floor tiles complete all as specified and directed.
M&L for coloured Ceramic tiles 7 to 8 mm thick light shade area of each tileexceeding 0.18 sqm but not exceeding 0.38 sqm, infloors etc. set and jointed inneat cement slurry andpointed in white or coloured cement to matchcomplete all as specified and directed.
S & F for 18/19 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to frame work in table top, cup board shutters, partitions, shelves etc. complete all as specified and diercted.
S & F 30 mm width of flaps continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
S & F 40 mm dia, cupboard knobs fixed with nut, screw and washer of brass polished, bright, bright finished complete all as specified and directed.
S & F second class hard wood (CHIR) plain fillets square, rectangular or traingular in section, clean sawn secured with nail sectional area 6 sqcm but n.exc. 13 sqcm complete all as specified and directed.
S & F 75 mm long brass handles, cast type, polished bright complete all as specified and directed.
S & F for 50 mm size brass two levers lock for cupboard, grade I, complete all as specified and diretced.
S & F mild steel magnet cacher of size 50 mm long body all as specified and as directed.
Taking down the existing roof treatment including roof tiles, plaster and cleaning the surface with wire brush and remove all dirt,dust etc. complete all as specified and as directed.
M&L for 10mm thick plastering on roof with WPC in cement mortar 1:3 for roof tratment all as specified. Note : WPC shall be measured and paid seperately.
M&L for seven course water proofing treatment over RCC slab by applying oil bound bitumen primer @ 0.20 kg/Sqm providing and laying 4mm thick APP modified water proofing membrane of make BASF/M/S Fosroc/IWL/STP Ltd weighing not less than 4.00 kg/sqm reinforced with non woven polyster matt weighing not less than 160 gm/Sqm having soften point not less than 140oC longitudinal tensile strength not less than 650 N/ 5 cm tearing strength of 180 N/ Torque application, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 kg/Sqm finished with solar reflective/ bituminus aluminium paint @ 0.10 kg/Sqm, keeping a minimum of 10 cm over laps and 15 cm end lap (7 course - Primer + Bonding Material+ APP+Bonding material+APP+Bonding material+Finishing coat).
Supply only integral water proofing compound complete all as specified and as directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. Note:- Debris shall be deposited outside MD land
M&L for Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for coping or chamfered on edges complete all as specified and as directed.
M&L for PCC type D-2, 1:4:8 using 40mm graded aggregate 100mm thick for hard standing/plinth protection, path, paving ect complete all as specified and directed.
M&L for Hardcore of broken stone of guage n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified.
M&L for coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm spreading and levelling in layers n exc 25 cm thick and well ramming including watering as required.
S&F Machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed.
M&L 150 mm thick floor PCC 1:3:6 type C-2 (using 40mm graded stone aggregate)for laying base floor complete all as specified and as directed.
M&L 40mm thick floor PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) finished even and smooth in laying floor complete all as specified and as directed.
M&L Door closer hydraulically regulated designation number 2 for door shutter weight between 36 to 60 kg aluminium ( extruded section) complete all as specified and as directed.
M&L Mortice lock brass vertical type 75mm size complete all as specified and as directed.
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and as directed.
M&L for Forming Construction joint 39mm deep x 10mm wide filled with sealing compound grade A complete all as specified and as directed.
M&L repairs powder coated aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws handles etc. complete all as specified
M&L for complete removal of existing treatment of plastered surfaces and applying two coats of plastic emulsion paint over and including with alkali resistant priming paint preparatory to distempering on surfaces of walls.
M&L for 3mm thick wall care putty on internal walls in two layers including grinding and cleaning the surface before application of primer all as specified and directed .
M&L complete removal of existing treatment of plastered surfaces ceiling surfaces and applying two coats of oil bound distmper over one coat of alkalli resistance priming surface complete all as specified and as directed.
S & F Supreme Interlocking Mat or SAMPADA Bauzooka EVA Foam Interlocking Tiles Floor Mats 600 x 600 x 25 MM Thickness is Made up of Fine and durable quality of EVA Foam, Which is Skin Friendly, Durable, Interlocking Mat is mostly and widely used in outdoor and indoor activities, protects floor incl all necessary fitting arragements ,adhesive etc and rate incl removing old existing interlocking tiles with cleaning ,removing old grease ,oil loose particle and preparation for new tiles complete all as specified and as directed.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain colour printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and as directed.
Taking down chowkats or frames not exc 1.5sqm each without taking off shutters from the frame.
Complete removal of existing surface finishes of external wall, preparation of surface and applying coat of suitable primer for weather proof paint complete all as specified and as directed . Note:- Application of paint and primer shall be as per manufacturer's instruction.
M&L for application of first coat of weather proof paint (anti fungal paint) ( Asian paint apex ultima protek or equivalent of Berger /Nerolac )on primed wall surface using spray application or mechanical means, to get a smooth and tint free surface and allowed to dry for at least 8 hrs/ overnight to receive second coat of acrylic exterior emulsion paint complete all as specified and as directed.
M&L for application of second coat of weather proof paint (anti fungal paint) ( Asian paint apex ultima protek or equivalent of Berger /Nerolac ) over first coat on wall surface using spray application or mechanical means, to get a smooth and tint free surface complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting sheet metal encl. with plug & socket etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
M&L , point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. single core multistranded cable in and including medium grade concealed PVC conduit not less than 20mm dia and accessories ISI marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and including 1.6 mm thick MS sheet/ pressed steel sunken boxes depth not less than 50mm (earth dolly) duly painted with two coats of anti corrosive paint / aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paints over a coat of red oxide primer externally covered with 3 mm thick plastic laminated sheet cover for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire for One light point controlled by one switch complete all as specifeid and as directed.
All as per item No. 62 above but for One fan point / exhaust fan point controlled by one switch & regulator complete all as specifeid and as directed.
All as per item No. 62 above but for One 5 pin 5 Amps Socket point controlled by one switch on same board complete all as specifeid and as directed.
All as per item No. 62 above but for One 5 pin 5 Amps socket point controlled by one switch on independent board complete all as specifeid and as directed.
All as per item No 62 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board complete all as specifeid and as directed.
M&L , point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. single core multistranded cable in and including PVC casing capping with all accessories and including 1.6 mm thick MS sheet/ pressed steel sunken boxes depth not less than 50mm (earth dolly) duly painted with two coats of anti corrosive paint / aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paints over a coat of red oxide primer externally covered with 3 mm thick plastic laminated sheet cover for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire all as specified and as directed for One light point controlled by one switch complete all as specifeid and as directed.
All as per item No. 67 above but for One fan point / exhaust fan point controlled by one switch & regulator complete all as specifeid and as directed.
All as per item No. 67 above but for One 5 pin 5 Amps Socket point controlled by one switch on same board complete all as specifeid and as directed.
All as per item No. 67 above but for One 5 pin 5 Amps socket point controlled by one switch on independent board complete all as specifeid and as directed.
All as per item No.67 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board complete all as specifeid and as directed.
Taking down existing tube light fitting, complete 1x20 W/ flood light/ high bay light of any size and keep aside for re-using or removing to store yard complete all as specified and directed.
Taking down existing round type/ square type ceiling lights of any type & size and keeping aside or removing to store yard complete all as specified and directed.
Taking down existing MCB DB SPN of 8 ways along with MCBs & MCB SPN & removing to store yard complete all as specified and directed.
Taking down existing building security light/flood light of any wattage and keep aside for re-using or removing to store yard complete all as specified and directed.
S&F switch piano flush type 5A one way complete all as specifeid and as directed.
S & F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specifeid and as directed.
S&F Socket 5 pin 5 Amps flush type complete all as specifeid and as directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specifeid and as directed.
S&F Switch piano flush type single pole 1 way, 15 Amps complete all as specifeid and as directed.
S&F step type fan regulator electronic flush type, 230 Volts, 5 step type, 450 Watt, flush type complete all as specified and directed.”
Supply & fix Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt ( Luminar efficiency of LED tube rod shall not be less than 100lumen /watt) both side connection all as specified and as directed. Make of batten : Havells Cat Part No. Regal batten 8UPT001X22WSSBSWH / Crompton Cat Part No. IGP131LT8-16 / Philips Cat Part No. TMC501P1XTLED22WP3241 Make of tube rod : Havells Cat Part No. Crystal 1213T8DSTL20W LED 865 GLASS / Crompton Cat Part No. LG-T8-20-865-2 / Philips Cat Part No. Essential LED tube 1200mm 20W865T865T81ND-1
Supply & fix LED down lighter 2'x2' , 36 W 240 volt all as per specified and directed. Make Havells Cat Part No. ENDURASLIMPROPLUS 2x2 PLR36WLED 840MOD and driver LEDDRIVER36V36WS or Philips/ Crompton Note:- High performance low- height downlighter suited for any modern professional workspace. Robust PDC aluminum housing ensures long life shall be 4000K and Efficacy 100 LM/W”
Supply and fixing building security light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 30 Watt ,efficacy 110LM/W including suitable GI bracket of 25 mm dia and fixing arrangement on walls all as specified and directed. Make: Crompton Cat Part No. Cat Part No. LSTS-30-CDL/NL-M/ Philips HSN code 94054090/ Jaguar Cat Part No. LPCRSRT30WXW.
S&F LED flood light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection, 3000 K, with 10 KV SPD of 50 watt 200 watt,50 HZ System efficacy ≥ 110LPW. Option for 3000K. 10KV SPD included with all accessories of all as specified and directed. Make Crompton, Cat Part No. LFL-50-CDL/60-M/ Jaguar Cat Part No. LFLD02S050XW/ Philips Cat Part No. BVP 161 LED 43 NW/CW/WW 50W
Supply & fix ceiling fans complete with electronic type regulator and accessories 230 V, 1200 mm sweep. BEE 5 star rated complete all as specified and directed including taking down old fans and depositing with MES store yard.”
Taking down existing ceiling fan and Painting of celing fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed .
S&F Sheet metal enclosure MCB SPN DB 8 way double door (metal door) IP 43 type suitable for 200 amp\ including all electrical connection all as specified and as directed. Make : Schneider Cat Part No. A9HSNS08 / L&T Cat Part No. DBSPN008SD / Legrand Cat Part No. XLᶟ400
S&F MCB 'B' Curve 40 Amp SPN ,240 Volts, 10 KA all as specified and directed. Make Schneider Cat Part No. A9N2P40B or equivalent in list of makes
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts,10KA all as specified and directed. Make : Schneider Cat Part No. A9N1P06B-32B / L&T Cat Part No. BB10320B / Legrand Cat Part No. 408587-408596
Taking down old sub main wiring of any type and size and removing to store yard, making good disturbed wall surfaces matching with existing surfaces all as specified and directed.
M/L submain wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 4Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity conduto9r and connceting with suitable size thimble complete allas specified and as directed. Note: two run of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
S&F GI tubing light grade fixed complete on walls/ceilings of 40mm dia for fixing of fans complete all as specified and as directed.
“Materials and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with galvanized strip of size 25 x 4 mm by means of nuts, bolts, check nuts and washers made of galvanized iron or steel earthing lead to be protected by galvanized iron pipe 40 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanized iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-in forced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed.
Supply and fixing LED foodlight luminaire with secondary optics made in pressure die-cast housing and heat sink in aluminium extrusion with IP 66, 200 watt,50 HZ System efficacy ≥ 120LPW. Option for 3000K. 10KV SPD included with all accessories complete” connection and outer covering with necessaries flexible pipe ,monitoring arrangement complete all as specified and as directed. Make. Bajaj cat No BARFEG 200W LED or Make Crompton Cat Part No. LFLN-200-CDL/60-M / Make Luker Cat Part No. LFL200”
Supply and fixing LED Highbay luminaire,200watt,Uniquely designed circular highbay with IP lens ,140 Lumens/W , IP66 with additional safety chain and all necessaries connection complete all as specified and as directed.. Make CG cat No CIP-326-200-57-60D-HL4-LM-NSG or Make Crompton Cat Part No. LHB11-200-CDL/60-M / Make Luker Cat Part No. LHBY200”
M&L Earth continuty or main earthing lead fixed to wall on betten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc galvanised iron Strip of size 25x4 mm complete all as specified and as directed.
S&F MCCB 3 pole, 415 Volt fixed type 100 Amps with breaking capacity 16 KA complete all as specified and directed including suitable enclosure for fixing on wall complete all as specified and as directed..
S&F Sheet metal enclosure TPN for DB's when MCB's to be used 6 way with 200 amps bus bar double door IP 43 glazed door complete all as specified and as directed. Make L & T cat No DBTPN006GD /Make Legrand Cat Part No. 5078 96 / Make Schneider Cat Part No. A9HTND06”
S&F MCB 'B' Curve 63 Amp 4 pole, 415 Volts,10KA complete all as specified and as directed. Make L&T Cat Part No. BB40630B/Make Legrand Cat Part No. 4087 02 / Make Schneider Cat Part No. A9N4P63B complete all as specified and directed.”
S&F MCB 'B' Curve 6-32 Amp SPN ,240 Volts,10KA complete all as specified and as directed.Make L&T Cat Part No. BB20320B / Make Legrand Cat Part No. 4086 02 to 4086 17 / Make Schneider Cat Part No. A9N2P06B to A9N2P32B
All as per item No 92 but 2 single core 6 Sqmm with 6 Sqmm earth wire complete all as specified and directed. Note: Two run of 6 sqmm size PVC cable , one run of 6 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
M&L for sub main wiring with 4 runs of 16 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 16 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good distrubed surface to match with existing surface complete all as specified and as directed. Note -1. 4 runs of 16 Sqmm sub main wire and one run of 16 sq mm for earthing and one run of conduit with accesories shall be measured as one unit.
Taking down old earthing complete all as specified and directed.
ANIE JOHN CONTRACTORS
K THOMAS AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .