| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.8 Cr+₹15.4 L (9.42%)Rejected-Finance NOT AVAILABLE | ₹1.8 Cr+₹15.4 L (9.42%) | L2 | Rejected-Finance Reject |
| 3 | L3₹1.9 Cr+₹23.5 L (14.4%)Rejected-Finance | ₹1.9 Cr+₹23.5 L (14.4%) | L3 | Rejected-Finance Reject |
| 4 | L4₹1.9 Cr+₹28.7 L (17.5%)Rejected-Finance | ₹1.9 Cr+₹28.7 L (17.5%) | L4 | Rejected-Finance Reject |
| 5 | L5₹2.0 Cr+₹35.2 L (21.4%)Rejected-Finance HIMACHAL PRADESH HP | HAMIRPUR | HIMACHAL PRADESH | 174304 | ₹2.0 Cr+₹35.2 L (21.4%) | L5 | Rejected-Finance Reject |
Tender Value
₹2.0 Cr
EMD Value
₹2.3 L
Closing Date
12 Sept 2023, 11:30 amClosed
Executive Engineer Jal Shakti Division Nohradhar
Executive Engineer Jal Shakti Division Nohradhar
SH CO RCC Dam at village Dana Barbed wire fencing wire crate work Head weir providing laying jointing of MSERW scour pipe and Laying jointing of GMS pipe line in distribution system for village Dana Upper Rajana Kail Job 5
2023_HPIPH_77976_1
NDR--SMR08-767-6393-6492 Dt 25-08-2023
Open Tender
Civil Works
Item Rate
120 days
Nohradhar
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,500
Executive Engineer Jal Shakti Division Nohradhar
₹2.3 L
Yes
Nahan
23 Nov 2023
25 Aug 2023
12 Sept 2023
26 Aug 2023
12 Sept 2023
31 Aug 2023
1 Sept 2023
Amount
Excavation in foundation and trenches in all type of soil such as pickwork jumper work Kankar, moorum, shingles including decomposed soft and hard rock etcupto all heights stacking the excavated earth not more than 3mtrs clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinths sides of foundations etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth in all leads and lifts as per the direction of Engineer in-charge.
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand :12 graded stone aggregate 40 mm nominal size ) and curring complete excluding cost of form work in foundation and plinth in all heights and depths including all leads lifts and carrige of material at site and as directed by the Engineer Incharge.
Providing and laying cement concrete plum concrete 1:5:10(1cement:5sand:10graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining walls/breast walls, the size of plums shall usually be 150mm to 300mm as per HPPWD specification. including entire carriage of material upto all leads and lifts.
Providing and laying cement concrete 1:4:8(1cement:4approved sand:8app.graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.
Providing and laying cement concrete 1:3:6(1cement:3 approved sand:6 app.graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.
Providing and laying cement concrete 1:1.5:3(1cement:1.5approved sand:3approved graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Wall (any thickness but not less than 0.1m thickness) attached pillasters,buttresses plinth and string courses etc. from top to foundation level upto floor two level and as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.
Providing and laying cement concrete 1:1:2(1cement:1 approved sand:2 approved graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Foundation and plinth including entire carriage of material upto all leads and lifts.
Wall (any thickness but not less than 0.1m thickness) attached pillasters,buttresses plinth and string courses etc. from top to foundation level upto floor two level and as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.
Providing and laying cement concrete work 1:2:4 ( 1 cement :2 sand :4 graded stone aggregate 40 mm nominal size ) and curing complete excluding cost of form work in foundation and plinth including all leads lifts and carriage of material at site and as directed by the Engineer Incharge
Providing and laying reinforced cement concrete work 1:2:4 ( 1 cement :2 sand :4 graded stone aggregate 20 mm nominal size ) excluding cost of form work and reinforcement for reinforced concrete work:-
Foundation and plinth including entire carriage of material upto all leads and lifts.
Wall (any thickness but not less than 0.1m thickness) attached pillasters,buttresses plinth and string courses etc. from top to foundation level upto floor two level and as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish. Including centring,shuttering strutting and propping etc. with wooden battens and ballies height of propping and centring below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu reinforced concrete and plain concrete work in:-
Vertical surface such as wall of (any thickness) partition and the like including attached pillaster buttresses plinth and string courses and like and as per the direction of Engineer-in-charge .including entire carriage of material upto all leads and lifts.
Providing tor steel reinforcement for RCC work including bending,binding and placing in position complete upto floor two level.as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.
Cement concrete flooring 1:2:4 ( 1cement : sand : 4 graded stone aggregate 20mm nominal size) and laid in one layer finished with a floating coat of neat cement, 40mm thick including all leads lifts and carriage of material at site as as per the direction of the Engineer incharge.
Cement Concrete lining 15cm thick or less for irrigation channels using cement concrete 1:3:6 (1 Cement: 3sand: 6graded stone agg. 20mm nominal size) and curing complete excluding cost of form work included all leads lifts and carriage of material complete in all respect and as per direction of Engineer in charge.
Hand Mixed concrete in bed
Hand mixed concrete lining in side slopes.
Extra allowance for form work in concrete lining including all leads lifts and carriage of materials at site complete in all respects on side slopes as per direction of Engineer in charge.
Providing and placing in horizontal layer filtering media duly graded, screened, washed and cleanned as specified by the Engineer incharge including all leads lifts and carriage of material at site and as directed by the Engineer incharge.
Bottom layer Broken stone 50mm to 75mm
Wire crates made of G.I. Wire filled with boulders with square cut faces against the wire (boulder filling to be measured and paid for separately) G.I. Wire 5mm thick corresponding to SWG-6 15cmx15cm mesh.as per direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.
Wire crates of G.I. wire filled with boulders with square cut faces against the wire (wire crates to be measured and paid for separately) including entire carriage of material upto all leads and lifts dry hand packed tightly in wire crate vertical bund with opening faces (wire crate to be measured and paid for separately) including entire carriage of material upto all leads and lifts.
Steel work in single section incliding cutting, hoisting, fixing in position and applying a priming coat of red lead paint
in R.S. joints channels angles, tees etc. ( angle 50x50x5 mm)
Providing and fixing galvanized steel bar-bed wire (IS:278-1962 Type-I) weighing 9.38 kg per 100 metres (minimum) straining and fixing to any type of standard rails, straining bolts including securing with and provision of galvanized mild steel wire, staples or Steel pins etc. as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.
Steel work welded in built up sections, trusses, framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in gratings, framed guard bars, ladders railling, brackets and similar works with locking arrangement as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.
Dressing bed and preparation of sub grade for lining in pick work as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.
Dressing side slopes and preparation of sub grade for lining in pick work as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.
Manufucturing and fixing of manifold distributor of GI Pipe 80 mm dia with 25 mm dia outlets including cutting , welding and fixing at site as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.
Providing and fixing double flanged cast iron sluice valve of following dia. of leader/Kirlosker/KSB make as per IS 780 class PN-1.6 and capable of with standing the normal seat pressure as per IS 5312-1884 P-1 and as per direction of the Engineer- in-charge upto all lead and lifts.
80 mm dia
350 mm dia
Providing and fixing solar light including posts and other fixtures as per direction of the Engineer Incharge.
Providing and fixing M.S. Gate of size 1.20 x 1.50 mtr. including cutting, welding, red lead paint and locking arrangement with lock complete including all leads, lifts and carriage of material at site and as per the direction of Engineer Incharge
Providing and fixing of gun metal gate valve of following dia. as per direction of Engineer-in-charge.including entire carrige of meterial upyo all leads and lifts.
25mm dia
80mm dia
Excavation in drains and channels etc in earth work in all kinds of soil such as kankar moorum , shingles, conglomerate saturated soil decomposed of soft rock & hard rock by blasting including dressing of sides and beds, disposing of excavated earth with in all leads and lifts, disposed earth to be levelled and neatly dressed and then returing the stacked soil in to foundation and trenches etc including ramming and watering and consolidating the same whereever required with all leads, lifts and including jungle clearance and as per the direction of the Engineer Incharge.
Providing, laying, testing & commissioning at site in trenches bevelled ended MSERW pipes of grade-A conforming to IS/ ISO 3183-2017 latest with upto date amendements having wall thickness and per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge. The pipe shall haves zinc coating inside & out side conforming to IS-4736-1986 or latest with upto date amendments & shall be ingraved with GRADE- A The laying shall conform to BIS 5822-1970 or latest with upto date amendments to the entire satisfaction of Engineer-in-charge (Earth work shall be measured and paid for separately).
Dia Thickness
Laying, Jointing testing & commissioning at site in trenches following plain ended GMS pipe of following dia. of heavy/medium grade as under conforming to BIS 1239(part-10 1990 OR LATESTWITH upto date amendments, capable of withstanding required test pressure as prescribed in BIS code in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled sutiable for butt weld, including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applivable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site tail pieces tees bends manufactured from parent pipes etc. and cutting of pipes wherever reauired as per site requirement including carriage in all leads lifts as directed by Engineer-in-charge (earth work shall be measured and paid for separately).
Dia Grade
80mm Light
Providing welding and fixing M.S plate flanges of following dia (nominal bore) of following flanges Table conforming to IS 6392-1971 or latest with upto date amendments to MSERW/G.I. pipe after every 100 metres or as per site requirement including cutting of pipes wherever required welding in three layers (leak proof) conforming to specifications as prescribed in relevent IS code i.e IS 816-1969 or latest as applicable with upto date amendments with nuts, bolts & washers and specials etc. fonforming to IS 1963 or latest with upto date amendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticrossive paints complete in all respect in all leads lifts and carriage of material at site and as directed by the Engineer-in-charge.
Dia Flange Table
ANKUSH KUMAR
akash
RAM KISHAN CHANDEL
Vijay Kumar
shiv iron general engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .