Loading…
Loading…
Tender ID
Tender Value
₹1.7 L
EMD Value
₹4,214
Closing Date
7 Mar 2026, 3:00 pmClosed
ASSISTANT ENGINEER
assistant engineer ayyappancovil gp marykulam 685507
Thanolikkada Drinking Water Project
2026_LSGD_841806_4
4/AE/LID_EW/AYK/2025_26
Open Tender
Civil Works - Others
Item Rate
AYYAPPANCOVIL GP
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
Yes
₹4,214
Yes
28 Feb 2026
28 Feb 2026
9 Mar 2026
28 Feb 2026
7 Mar 2026
28 Feb 2026
Tanolikkada drinking water project
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD440317/2025-2026:supplying precast factory moulded RCC Ventilator frame of size 90x50 cm or nearest size and fixing in position in line and level directed by the engineer in charge including fixing MS clamp 3 nos.with minimum length of 25 cms on each vertical side of the frame with necessary screws and fixing the clamp with concrete in wall using 1:2:4(one cement:2 fine sand:4 coarse aggregate 20 mm) concrete mix including all cost of conveyance,materials cost,labour charges and curing charges etc. complete.(concrete for fixing the clamp shall be paid separately)
OD440316/2025-2026:supplying precast factory moulded RCC door frame of size 90x210 cm or nearest size and fixing in position in line and level directed by the engineer in cherge including fixing MS clamp 3 nos.with minimum length of 25 cms on each vertical side of the frame with necessary screws and fixing the clamp with concrete in wall using 1:2:4(one cement:2 fine sand:4 coarse aggregate 20 mm) concrete mix including all cost of conveyance,materials cost,labour charges and curing charges etc. complete.(concrete for fixing the clamp shall be paid separately)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11.3.1:Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
18.19.4.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore
OD440322/2025-2026:Roofing with GI trafforded profile sheet 0.35mm thick powder coated with over lap of 150mm at end and SS screws including plain washer and bitumen washer etc
OD440321/2025-2026:Supplying and fixing 3 core flat cable
OD504971/2025-2026:HDPE DP APPROVED RATE(Supplying and fixing 50 mm dia 10kg/cm2 hdpe pipe 10kgf/cm2 PE-80 Including specials all fitting charges but excluding trenching and refilling etc complete
OD504969/2025-2026:SUPPLYING AND FIXING 1.5 HP KIRLOSKAR MOTOR, THE MOTOR INCLUDING ALL LABOUR CHARGES
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
OD480256/2025-2026: supplying and fixing panel board suitable electrical fittings (ELCB) including all labour charges
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
OD480301/2025-2026:HDPE DP APPROVED RATE(Supplying and fixing 50 mm dia 8 kg/cm2 hdpe pipe 8 kgf/cm2 PE-80 Including specials all fitting charges but excluding trenching and refilling etc complete
OD480344/2025-2026:supplying and fixing centralised distribution system with gi pipe holder rate for one distribution tap
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
SBD.pdf
Other Document • 1.88 MB
BOQ_1420093.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .