| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance ALWAR | RAJASTHAN | 301001 | -24.71% | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 CrAdmitted-Finance | -23.56% | ₹1.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.3 CrAdmitted-Finance | -18.51% | ₹1.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹1.7 CrAdmitted-Finance | +7.99% | ₹1.7 Cr | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical Reject |
Updated dates
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
1 Mar 2026, 6:00 pmClosed
EE PWD ELECTRIC DIVISION KOTA
EE PWD ELECTRIC DIVISION KOTA
ELECTRICAL UTILITY SHIFTING WORK ON NH148D (SAMRAWATA VILLAGE)- BAMBOOLI- BAMANGAON- JARKHODA- KARWAR- ARNETHA- ANTARDA- TALWAS- SH34 (JETPUR KM 68/700) KM 0/0 TO 33/00 MDR 410 IN DISTRICT BUNDI
2026_CEPWD_537400_1
EE PWD ELECTRIC DIVISION KOTA NITNO30-2025-26
Open Tender
Electrical Works
365 days
BUNDI
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
2000 E-GRASS CHALLAN AS PER NIT
₹3.8 L
Yes
10 Mar 2026
10 Feb 2026
4 Mar 2026
10 Feb 2026
1 Mar 2026
10 Feb 2026
Supply and erection of P.C.C. pole as per REC manual no 15/1979 (amended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit up to pole planting depth 1/6th of pole length. and back filling with stone aggregate/ boulders and soil by ramming and watering etc. complete as required. 9.0 Mtr long PCC pole of 200 Kg Working Load
Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron cross head and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc. complete as required. Stay set of dia. 20mm, 2.4m long stay rod and anchor plate 380 x 380 x 4.0 mm
Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. LT cross arm 600 mm long with clamp
Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. 100 mm x 70 mm
Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. 75mm x 90mm
Supplying and drawing overhead Aluminum conductor steel Reinforced (ACSR) ISI marked (IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required.
50 Sq.mm of (6+1) 3.35 mm (Rabbit)
100 sq.mm of (6/4.72 mm+1/1.57 mm) (Dog)
50 Sq.mm of (6+1) 3.35 mm (Insulated Rabbit) for LT
Supply and fixing of Galvanized steel 'V' type cross arms with clamps as per latest Discom specifications made of Galvanized steel angle(65x65x6) on the existing poles complete including all necessary nut and bolt, clamps as required.
Supply and fixing of Galvanized top hamper on the existing pole as per latest Discom specifications complete including nut bolts etc. as required.
Vertical type 11 kV (.7m long) (65 x 65 x6mm Galvanized Steel angle)
Horizontal type 11 kV with double top hamper (65 x 65 x 6mm Galvanized Steel angle)
Supply and fixing of galvanized steel Channel Bracket 100 mm x 50 mm with clamp as per Discom Specifications including Nut, Bolt with two coats of Red oxide and two coats of Aluminum paint etc. as Required.
1.8 Mtr. Long
1.4 Mtr. Long
Supply and fixing of 11 kV pin insulator confirming to IS: 731:1971 with latest amendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required.
Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required.
T & C type hardware 45 KN
T & C disc insulator 45 KN
Supply and fixing of PG / T clamps on overhead lines/jumpers, made of aluminum alloy 4600 of IS 617-1994 (with latest amendment if any) with steel nut and bolts conforming to IS 1363-1992 & IS 1367/1979-80 (with latest amendments if any) all ferrous metal parts intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986 complete in all respect as required.
PG Clamp for Dog Conductor Type - A
PG Clamp for Rabbit Conductor
Supplying and laying of Hot dip galvanized steel stay wire of 550-900 N/mm Quality confirming to IS-2141/2000 in all respect Including chemical composition (Heavily coated Hard quality) of dia. 7/3.15 mm (7/10 SWG) and as per latest Discom specs. etc. as required.
Supply and fixing of 11 / 33 KV Stay insulator as per IS:5300/1969 and as per Discom's standard specifications etc. as required.
110 x 75 x 22mm 11 KV Stay Insulator
140 x 85 x 25mm 33 KV Stay Insulator
Supply and fixing of 100 Amp, 11kV Horn gap fuse set IS 9385 on existing DP structure with 6 nos 24kV/22kV post insulator (IS:5350 part III), hot dipped hard ware, fuse wire of required size etc. complete in all respect as per Discom specification etc. as required.
Supply and fixing of 11 kV, 400 Amp 3 pole, central pot rotating double break type isolator (IS:9921 part I to V) without earth blade operating mechanism with GI spring loaded reverse loop type fixed contact, solid hard drawn electrolytic copper tubular moving contact with silver/ nickel plated at end points, 9 nos post insulator of 12 kV (IS:2554 & IS 5350 part III), hot dipped galvanizing hard ware, nut, bolts etc. complete in all respect as per Discom specification etc. as required.
Supply and fixing of distribution type Lightening arrestor (Set of 3 Nos.) 9 kV, 10 kA (IS:3070) with mounting breaking to be installed on existing DP structure etc. as required.
Supply and fixing Substation structure for mounting 11/0.4 KV Transformer on Double pole as per DISCOM specification complete in all respect as required including nuts and bolts etc. (excluding the cost of poles) made of MS channel of 4 nos 100 x 50 x 6mm and 4 nos 75 x 40 x 6mm and MS flat 50 x 6mm etc. as required.
Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respect as required.
Providing and fixing of single pole mounted substation structure set for isolator / single phase transformer as per DISCOM specification complete in all respect with nuts and bolts as required MS flat 50 x 6mm, MS angle 65 x 65 x6mm, MS channel 100 x 50 x 6mm. (Excluding cost of pole). Etc. as required.
Supplying and drawing of XLPE insulated LT Aluminum conductor Aerial bunched cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required.
1 X 25 sq. mm. + 1X25 sq. mm. (insulated)
3 X 16 sq. mm. + 1X25 sq. mm. (insulated)
Supply & Erection of Galvanized steel lattice structure of height 12.8 mtr as per DISCOMs approved design & details in alignment, including painting of tower of approved make, all completed as per technical specifications & drawing of DISCOM. (Excavation of pit PCC and CC foundation as per Discom specs. to be Paid Extra).
Supply & Erection of Galvanized steel lattice structure of height 11.0 mtr as per DISCOMs approved design & details in alignment, including painting of tower of approved make, all completed as per technical specifications & drawing of DISCOM. (Excavation of pit PCC and CC foundation as per Discom specs. to be Paid Extra)
Supply of Fabricated 33 KV of 'V' type cross arms made of Galvanized steel angle (75x75x6mm) with clamps etc. on the existing poles complete including all necessary nut and bolt etc. with clamps as required.
Supply and fixing of Galvanized steel top hamper as per Discom specifications on the existing pole complete including nut bolts etc. as required. Vertical type 33 kV. 0.75mtr. IS Galvanized angle 65x65x6mm as per tech specs. Of DISCOM (Steel weight 5.8Kg. Approx. per top hamper).
Supply & Erection of special stud structure for 33KV lattice structure as per Discom specifications made of M.S. angle, channer, flats complete in all respects with bracings including painting of tower of approved make two coats of red oxide paint and one coat of aluminum paint before installation and one coat of Aluminum paint after erection work completed as per technical specifications & drawing of DISCOM. (Excavation of pit PCC and CC foundation as per Discom specs. to be Paid Extra).
Supply and fixing of 33 kV pin insulator confirming to IS: 731:1971 with latest amendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required.
Supply and fixing of 33 kV Disc insulator and Hot dipped galvanized Hardware confirming to IS: 731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required.
B & S type hardware 120KN
B & S disc insulator 120KN
Supply and fixing of guard bracket 2.2 mtr. long made from (75x40) ISMC 7.14Kg. Per Mtr. M.S. channel including necessary clamp and bolts etc. as per technical specification & drawing of DISCOM.
Supply and fixing M.S. channel (cut point) 100x50mm ISMC (9.5Kg. Per Mtr.) 2x1.8mtr. long with pilot patti 50x6mm thick necessary nuts and bolts etc. as per technical specification & drawing of DISCOM.
Supply and installation of spike of M.S. rod 20mm dia. 3.0 mtr. long for earthing of (tower/pole) drive into earth by mechanical means structure connection the spike with cross arm top hamper PCC pole, lattice tower to earth etc. complete as per technical specification of DISCOM.
Labour charges for Dismantling the structure with pole mounted transformer of different capacity along with distribution boards and re- erecting the transformer on newly erected structure along with distribution boards and including testing and commissioning (as well as cabling connection complete as required)
Labour charges for dismantling of existing PCC/MS electrical Pole including MS channel, V cross arm, 11KV insulator, LT insulator, guard wires, stay wires, one span of ACSR conductors and other electric items, coming along and in the alignment of the road, then removal and re-rolling of the PCC /MS Pole as well as other materials and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and as per the direction of Engineer Incharge, clean the site good as per the requirement and dismantle material receipt duly signed by DISCOM Engineer submit the receipt to EIC as required.
Labour charges for dismantling of existing Lattice tower including MS channel, V cross arm, 11KV/33 KV insulator, guard wires, stud/stay wire, one span of ACSR conductor and other electric items coming along and in the alignment of the road, then removal and re-rolling of Lattice tower as well as other materials and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and as per the direction of Engineer Incharge and clean the site good as per the requirement and submit the receipt from DISCOM/ concerning authority complete as required.
Labour charges for dismantling of service line connection (weather proof cable/armoured cable) for single phase /three phase supply of industrial/domestic connections from existing PCC/MS pole and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and provide temporary supply to domestic/industrial connections to the consumer where supply is disconnected and clean the site good as per the requirement and direction of Engineer Incharge complete as required.
Labour charges for Trimming of tree branches/plants and preparing route approaches for electric proposed line complete with prior permission of local authority in writing, taking proper shutdown from discom office and inform to DISCOM after complete the work.
Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS : 7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. 6.0 Sq. mm, 2 core
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity>95% thimble etc. as required. 8 SWG G.I. ( Hot Dipped ) Wire
Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed:
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
Tendernotice_2.pdf
PDF • 1.49 MB
TERMSANDCONDITION.pdf
Tender Documents • 1.92 MB
BOQ_957557.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid