Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC MUNICIPAL BUILDING NEHRU PARK AVENUE BANK JUNCTION ALUVA ERNAKULAM ERNAKULAM KERALA 690573 | KOLLAM | KERALA | 690573 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹30.0 L+₹1.9 L (6.58%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹32.2 L+₹4.1 L (14.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹32.3 L+₹4.1 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹32.5 L+₹4.3 L (15.4%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
25 Apr 2024, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_648503_1
GE MAINT EZHIMALA 8638
Open Tender
Civil Works
Item Rate
150 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹65,000
Yes
20 May 2024
30 Mar 2024
27 Apr 2024
30 Mar 2024
25 Apr 2024
13 Apr 2024
1 Apr 2024 - 8 Apr 2024
Amount
Dismantling stone slab and tiles of any description or thickness in floors, landings aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
Taking down cement or cement lime plaster on brick or concrete surfaces including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
M&L for machine cut granite stone slab 20mm thick of approved colour and shade as in floors laid over 20mm thick screed bed in CM 1:6, jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including grinding and polishing complete all as specified and as directed.
M&L for machine cut granite stone slab 20mm thick of approved colour and shade as in skirting/dado laid over 10mm thick CM 1:4, anchored with anchor fastener and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including grinding and polishing complete all as specified and as directed. Note:- Supply only hilti make anchor fasteners, clamps and headless bolts shall be measured and paid separately.
M&L for 25mm thick flame finished sadarahalli machine cut stone of approved colour and shade as in floors, skirting/dado etc over and including 15mm thick backing coat in CM 1:4, laid and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab complete all as specified and as directed.
Supply only hilti make stainless steel anchor fastener 10 x 80mm for fixing of sadarahalli /granite stone cladding complete all as specified and as directed.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces with liquid water proofing compound and surface finished even and fair complete all as specified and as directed. Note:- Liquid water proofing compound (WPC) shall be measured and paid separately.
Supply only intergral waterproofing compound of approved quality complete all as specified and as directed.
M&L for sealing all the joints in sadarahalli stone with PU sealent including cleaning of existing surfaces complete all as specified and as directed.
M&L for preperation of new plastered surfaces and applying two coats of plastic emulsion paint (interior grade) on wall over a coat of acrylic primer over 1mm thick putty complete all as specified and as per manufacturer's instructions.
Supply, install, testing and commissioning of diesel engine driven generating set 82.5 KVA with separate AMF panel (outdoor type & double door) with water cooled engine of suitable BHP for 66 KW power generation @ RPM 1500, brushless frame with silencer and canopy for sound less mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/dynamo and 66 kW/82.5 kVA electric alternator, 415 volts, 3 phase, 4 wire, 50 Hz, voltage regulation ± 15, insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components , fuel tank capacity as per OEM recommendations with level indicator installed on suitable steel frame with PCC foundation as per manufacturer's instructions, power command genset controller, fuel pipes, dual spin on fuel filter, dritype aircleaner, shutt off coil with safeties for LLOP/HWT, fuel pipes, bar metre, hour meter, oil temperature gauges, ammeter, ignition switch, radiator with cooling fan, maintenance free battery battery, including suitable size of copper cable leads with terminals, all mountings, accessories, necessary foundation and AVM pads complete as per manufacurer's recommendations and to the satisfaction of Engr in charge.
(A) PRIME MOVER:- Suitable for driving 66KW/82.5 KVA alternator liquid cooled battery start diesel engine of adequate capacity 110 BHP confirming to BSS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 hrs operaton complete with the following standard accessories:- a) Fly wheel to match with the flexible coupling b) Flexible coupling wih guard c) Air cleaner oil bath type / dry type d) Lubricating oil filter, fuel filter paper element type e) Blower type fan and radiator f) Governor for class "A" Governing as per IS-1601 of DS 649/1958 g) Starter motor for electric start complete with dynamo altermator, lead acid batteries heavy duty of capacity 12 V 65 Ah or as per OEM recommendations, Nos & capacity as required with copper conductor leads of adequate size and length not less than 2m including battery box all as directed. h) Hour meter and RPM indicator j) Exhaust pipe brought outside the building and lagging of entire length of exhaust pipe with 12 mm dia. k) Instrument panel duly wired comprising the following including protection for low lub oils high temperature :- l) Lube oil pressure gauge m) Battery change indicator meter n) Starting switch with key o) Lub oil temperature p) Engine temperature indicator (B) ALTERNATOR:- 66KW/82.5 KVA at 0.8 PF brushless self excited, self regulated 3 phase 50 Hz 415 V 1500 RPM 4 wire screen protected drip proof free from simulation problems continuous rating confirming to BS 2613 complete with automatic voltage regulator O/P voltage regulated between +/- 1% or set voltage from no load to full load. (C) AUTOMATIC MAINS FAILURE PANEL:- AMF panel (out door type & double door) for 66KW/82.5 KVA DG Set fabricated out of 3.15 mm sheet steel factory made suitable for trolley mounting hinged from panel for easy accessibility with suitable rated bus bar internal wiring and with provision for connecting incoming/outgoing leads with the following accessories :-
Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed.
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground, earth pit not less than 2.25 meter deep below ground level, connected to 32x6 mm size galvanised iron as earthing strip by means of bolts, nuts, check nuts, and washers of galvanised iron /steel all as shown in electric plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including provn of necessary excavation and earthwork in any type of soil, PCC pit, RCC cover and 20 mm bore medium grade watering pipe, water funnel with GI wire mesh, 40 mm bore medium grade protection pipe, common salt, charcoal dust, returning filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6mm galvanised iron strip complete all as specified and directed by Engr-in-charge.
Excavation in trenches in hard / dense soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying pipes complete all as specified and as directed. Note:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
Returning, filling in trenches in hard/dense soil in layers n.exc. 25 cm after laying of pipes including spreading, levelling, and well ramming etc complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supply and spreading riddled earth for cushioning of the UG cable in trenches complete all as specified and as directed. Note:- Punned thickness shall be measured for payment purpose.
Supply and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed.
M&L for cement concrete 1:2:4, type B1, using 20mm graded aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
S&F steel work in tubular trusses, rafters, purlins etc including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and as directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-410W, Gde E-250A) complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preperation of new steel surfaces over 10 cm width or girth complete all as specified and as directed.
S&F sheet metal enclosure double door out door type made out of 3.15mm thick MS sheet powder coated of suitable size with 200 Amps rated aluminium busbar with colour code including one no MCCB 125 Amps 25 KA & one 125 Amps on load changeover switch as incomer and suitable gland for cabling complete all as specified and as directed by Engr-in-charge.
Design, M&L for fabrication and installation of towing type DG set trolley made up of 4 wheeled trolley suitable for mounting of 82.5 KVA DG Set including four nos wheels, base frame with MS Channel and easy connect to other vehicles to move from one place to other place, suitable break system, locking arrangements, load bearing capacity of minimum 2.5 ton including trolley, trolley 4 wheeler size 5000(L) mm x 2200(W) mm x 1900(H) mm etc with following specifications & details :- Main chassis:- Main chassis will be of ISMC 200 x 65mm channel and cross member of 100 x 50mm ISM, welded with reinforcement, Side Runner :- Side runner and cross members channel made of MS 100 x 50 mm and 100 x 50 mm. Leaf springs :- 4 Nos leaf springs consisting min 13 Leaf each. Axle:- 2 Nos Axles made of min 75 x 75 mm M.S square with water proof steel forged hubs and taper roller bearings with load bearing cpacity minimum 2.5ton. Towing Arrangement:- Spring loaded steel towing hook. Floor Sheet :- Floor fully covered with 6 mm thick MS sheet. Landing Jacks:- 4 Nos landing jacks fitted on four corners of the trailer. Side wall:- Side wall height 1900 mm, openable with three sides, made of MS welded wire mesh 4 mm and angle 35 x 5 mm, supported with 40 x 5 mm MS flat, with danger notice board Electric 1100 V. Tyre Assembly:- 4 Nos new tyres assembly size 7.5 - 16PR with heavy duty disc with manual locking break system of pull type with brakes provided for both axles. Make:-CEAT/Apollo/JK. Finishing & Painting:- Finishing with grinding and one coat of red oxide (Primer) and 2 coats of super synthetic enamel paint (Any Colour). All the frame work will be degreased and spray painted with one coat of epoxy primer and two coats of epoxy paints. Manual sliding jack lift and pin type lock type, Earthing with flexible copper wire of 3 mtrs. Loading charges and freight charges till Ezhimala is deemed to be included in the quoted rate with maximum moving speed of 30 Kms/Hr. Note:- Design of trolley shall be vetted by Engr-in-charge before manufacturing complete all as specified and directed by Engr-in-Charge.
M&L for taking down existing old unserviceble geyser with connected accessories and deposit in MES store yard complete all as specified and directed by Engr-in -Charge.
S&F water heater storage type, electric capacity 25 Ltr, 240V, 50Hz including all accessories like connection pipe, clamps etc including necessary cutting on wall, concrete etc and BEE 5 star rated with the following features complete all as specified and directed:- (a) Current leakage protection. (b) High pressure themostate control. (c) Multi functional safety valve. (d) To withstand 8 bar of water pressure. (e) Vitreous enamel water tank. (f) Single weld line tank made out of ultra thick superior cold rolled sheet. (g) Heavy duty seamless incoloy 800 glass lined heating element. (h) Heavy density CFC free puf insulation. (j) Adjustment knob for temperature setting for energy savings. (k) Heating indicating lamp. (l) Stainless steel connection with SS braiding 1200mm, Grade A, ISI 304 (set of 2, 45cm, Silvermatt) for hot / cold water.
M&L for taking down existing old unserviceble exhaust fan with connected accessories and deposit in MES store yard complete all as specified and directed by Engr-in -Charge.
S&F exhaust fan (300mm) metal body including all accessories like clamp, screws, nuts, bolts, washers etc with following features complete all as specified and directed by Engr-in -Charge. (a) Size 300mm diameter fan blade. (b) Voltage requirements 220-230V. (c) Airflow:- strong ventilation. (d) Noise :- Low sound. (e) Feautures :- Shutters speed options.
RASNA ENTERPRISES
LAKSHMI BUILDERS
General Engineering and Constructions
KDR CONSTRUCTION
M/s K V Ramachandran
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .