Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹17.0 L+₹82,121 (5.08%)Rejected-Finance | L2 | Rejected-Finance Not lowest |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
25 Oct 2022, 6:00 pmClosed
GE(Works) 1
GE(Wks)1/DGNP(V) Naval Dockyard, Visakhapatnam. Andhra Pradesh
Repair and Replacement of Sunken floor, Tiling, sanitary fittings and allied works (Up to 5th floor) at DGNP main office, Equipment complex, DG House and Offices at Naval Dock Yard under DGNP (V).
2022_MES_550101_2
GE(Wks)1/Token/06 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
DGNP Vizag
All as per tender documents
6 documents required · 6 mandatory
₹500
Yes
DGNP VISAKHAPATNAM
₹36,000
Yes
8 Dec 2022
6 Oct 2022
27 Oct 2022
6 Oct 2022
25 Oct 2022
13 Oct 2022
6 Oct 2022 - 13 Oct 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises of MD land complete all as specified and directed.
Taking down existing water proofing treatment with PCC of sunken floor and cleaning sunken floor by washing and rubbing etc and removing the material retreived to a distance n.exc 500m where directed and material and labour for provn of water proofing treatment to sunken floors all as given below specifications with engaging authorised applicator:- (a) Making fillet of size 25mm x 25mm at corner of slab, providing necessary length of 25mm bore PVC pipe for water escape pipe and wall with polymer modified cementitious (PMC) mortar consisting of one part of tapecrete P-151, two parts of cement and six parts of fine sand by weight. (b) Sealing joints of pipe with epoxy putty or epoxy mortar. (c) Cleaning the concrete surface by brushing and watering and applying a coat of tapecrete P-151 Acrylic Modified Cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight . The coating shall be carried out upto 300mm above FFL and shall be allowed to dry for 4-6 hours. (d) Applying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand by weight and cured for 2 days. (e) Applying 15mm thick plaster in CM 1:4 mixed with and including waterproofing compound on treated surface of this schedule. Note: Rate quoted by the contractor is deemed for ponding test all as per IS 13182 : 1991 (Reaffirmed 2000) for 72 hrs.
M&L for filling the sunken portion with PCC 1:5:10, type E-2 (using 40mm graded crushed stone aggregate) upto required level complete all as specified and directed.
Demolition and breaking up drain pipes 75mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipes 100/110mm dia (PVC, Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L 75 mm dia PVC (SWR) floor trap, plain with steel grating including jointing with solvent cement complete all as specified and directed.
M&L in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F PVC 75 mm bore (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and directed.
S&F PVC 110 mm bore (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and directed.
S&F PVC 75 mm bore (SWR) branch piece, double (double Y), equal or unequal with access door complete all as specified and directed.
S&F PVC 110 mm bore (SWR) branch piece, double (double Y), equal or unequal with access door complete all as specified and directed.
S&F PVC 75 mm bore (SWR), junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F PVC 110 mm bore (SWR), junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F PVC 75 mm bore (SWR), junction double, (double T), equal or unequal with access door complete all as specified and directed.
S&F PVC 110 mm bore (SWR), junction double, (double T), equal or unequal with access door complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F PVC 75 mm bore (SWR) couplers complete all as specified and directed.
S&F PVC 110 mm bore (SWR) couplers complete all as specified and directed.
S&F PVC 110 mm bore (SWR) reducers complete all as specified and directed.
S&F PVC 75 mm bore (SWR) vent cowl complete all as specified and directed.
S&F PVC 110 mm bore (SWR) vent cowl complete all as specified and directed.
S&F in repair 15mm bore, steel water tubing, medium grade, galvanised with all fitting and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair 20 mm bore, steel water tubing, medium grade, galvanised with all fitting and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repairs 15 mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs 20 mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs 15 mm bore self closing taps, cast copper alloy, chromium plated, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15 mm bore stop valves, fancy type chromium plated cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F in repairs 20 mm bore stop valves, fancy type chromium plated cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F in repairs 32 mm bore waste coupling of PTMT (half or full threaded). Min wt 45 gms) complete all as specified and directed.
S&F in repairs 32 mm bore bottle trap of PTMT having minimum water seal of 25 mm. (Min wt 260 gms ) complete all as specified and directed.
S&F in repairs grating doom 100 mm dia of PTMT. (min wt 25 gms) complete all as specified and directed.
S&F in repairs grating doom 125 mm dia with waste hole of PTMT. (Min wt 40 gms) complete all as specified and directed.
S&F in repairs brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 300 mm complete all as specified and directed.
Supply and fixing in repairs kitchen sinks of stainless steel 1.00mm thick with plugs, washers and waste pipes and cast iron cantilever brackets including and connecting union to pipe over all size 495mm X 420 mm bowl size 410mm X 330mm X 160mm complete all as specified and directed.
S & F in repair wash down water closet squatting pan Orissa pattern size 580x440mm white with integral footrest and trap, with and including connection to drain and flushing pipe, making good to floor, making proper jointing between flushing pipe and sockets of water closet pan complete all as specified and directed.
S & F in repair vitreous china wash down water closet pan & trap (pedestal pattern) with plastic water closet seat black closet pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device with and including flush pipe to pedestal pan, all joints including connection to drain pipe and flush pipe complete all as specified and directed.
S & F in repair vitreous china toilet paper holder white box type complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltr capacity, valve less, symphonic action type with and including inlet, ball valve float and handle, bracket and flush pipe 32 mm dia complete all as specified and directed.
S & F in repair vitreous china white wash hand basin flat back size 550x400 mm with and including brackets chain & plug and waste pipe waste coupling etc. complete all as specified and directed.
S&F in repairs stainless steel with cromium plated health faucet with steel tube 1.5m long with screwed nut for inlet connection complete all as specified and directed.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces as backing coat in cement mortar 1:4 complete all as specified and directed.
S&F glazed ceramic coloured tile in vertical surface 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Cleaning of Man holes/chambers by removing muck/sludge/liquid mud etc (in foul position) upto complete existing depth including taking off manhole covers and refixing the same in position of any size of Man holes including removing sludge outside to MD land and spreading bleaching powder complete all as specified and directed.
Cleaning of blocked sewage lines by rodding between Man holes in any depth, cleaning and removing muck/sludge /liquid mud (in foul position) from pipes including testing of pipes by filling with high pressure water complete for 100mm bore pipe by own arrangement vehicle complete all as specified and directed.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Demolition of Reinforced cement concrete in roof, floors and roof (other than ground floor), beams, staircase, chajjas, landing and similar suspended work not exceeding 15 cm thickness and cutting of reinforced steel bar and segregation from the concrete, complete all as specified and directed.
Dismantling of existing water proofing treatment any type and thickness from top surface of roof slab including backing layer of mortar and removing the materials from the site etc complete all as specified and directed.
Demolition of cement concrete in ground floors and roof pavings not exceeding 15 cm thickness (below or above ground floor) complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in padding concrete on roof top complete all as specified and directed.
M&L precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in block masonry with solid blocks, exc 10 cm in width and setting in mortar complete 1:6 complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar 1:4 on concrete surfaces for laying floor finishes/roof treatment complete all as specified and directed.
Material and labour for cleaning the plastered/concrete surfaces with wire brushes and applying water proofing treatment as under :- (a) One coat of bituminous primer at the rate of 0.3ltr /Sqm of roof . (b) Hot applied bitumen 85/25 grade at the rate of 102kg (minimum) per sqm of roof. (c) 3mm thick APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt. not less than 150gms/sqm). (d) Hot applied bitumen 85/25 grade at the rate of 1.2kg (minimum) per sqm roof. (e) Final finish with bituminous aluminium paint at the rate of 0.15Ltr per sqm of surface. Complete all as specified and directed.
M &L providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in lintel upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, stringcourses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates, kerbs incl weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F coloured vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pilp, insulations, etc) or insulation boards/slabs/ ceiling of any thickness, including cover fillets , grid and frame complete all as specified and directed.
M&L techno T-Grid ceiling suspension system of main runner size 32mm x 24mm x 3600mm, Cross Tee size 27mm x 24mm x 1200mm & 27mm x 24mm x 600mm, wall Angle of size 22 mm, 20mm, 3050 mm, sheet thickness 0.30 mm, providing and fixing Techno Acoustic Mineral Fibre Square mineral tesured tiles suspension system, panels shall be of size 600mmx600mm x 12mm having noise reduction co-efficient 0.4-0.6 light reflection over 85 relative humidity 95% Grid system for fixing ceiling tiles shall comprise of Techno T-Grid suspension system, The 24 mm main Tee runner shall be suspended at an interval of 1200 mm centre. The 1200 mm cross tee shall be attached between to main runners at every 600 mm and further 600 mm cross Tee shall be interconnected between two 1200 mm cross tees. Thus a grid system of 600mm x 600mm is formed. The main tee shall be suspended by mean of 2/2.5 mm wire or 4 mm G.I. rod from slab/roof. The suspension shall be provided at 1200 mm centre to centre and not more 450 mm from the wall. However, the suspension shall not be more than 150 mm distance from the spliced joints of the main tee complete all as specified and directed.
S&F anodised aluminium snap grid size 605mmx605mm frame work for false ceiling complete all as specified and directed.
S&F hangers 6 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified and directed.
M&L 6 mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work with screws complete all as specified and directed.
M&L for 2nd class hard wood clean sawn in as in scantling framed and fixed to walls with screws etc complete all as specified and directed.
M&L 12 mm thick water proof Veneered particle boards interior grade, solid core, general purposes type, with face veneers of type 'BB', fixed with screws to timber frame work complete all as specified and directed.
SREE VSM ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .