Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68,100Accepted-Finance | ₹68,100 | L1 | Accepted-Finance Due to lowest Rates |
| 2 | L2₹69,400+₹1,300 (1.91%)Rejected-Finance VILLAGE PO NAGANPATT TEHSIL D SALA DISTT KANGRA HP | ₹69,400+₹1,300 (1.91%) | L2 | Rejected-Finance Due to Highest Rates |
| 3 | L3₹72,300+₹4,200 (6.17%)Rejected-Finance VILLAGE DHUNDHIYARA P O BELLI TEHSIL DALHOUSIE DISTT CHAMBA HP | ₹72,300+₹4,200 (6.17%) | L3 | Rejected-Finance Due to Highest Rates |
| Sl No | Description | Qty | Unit | M/S POLLY PHASE NEW ENGINEERING L1 | SIKANDER KUMAR L2 | ANITA KUMARI L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of submersible pumping set of /KSB/ Kirloskar/ Calama/Jyoti / BS / Sabar pump make conforming to BIS; 8034-1976 (latest with uptodate ammendments) fitted with bronze impellers/suitable for lifting clear water ( latest with upto date ammendments ) fitted with bronze impellers suitable. The pump should be fitted with free flow impellor of bronze/ suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear suitable for operation on 220 volts single phase 50 HZ . AC supply minimum class-B insulation, the power of motor 10% in excess of minimum power required by the pump in complete range of (-) 25% & (+) 40% of duty point head. . It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- | 1 | Job | 18,500 ₹18,500 Lowest | 19,000 ₹19,000 | 19,500 ₹19,500 |
| 1.01Total Head = 350.00 Mtr. (ii) Discharge required from each pump = 3.50 LPS each set, (iii) No. of pump required = 1 Nos. Set, (iv) Dia of Rising main = 50 mm dia, (v) No of working hours per day = 8.00 Hours, (vi) R.P.M. of pumping set. = 2900 RPM (or to be specified by the tenderer), (vii) Test Run = 20 Hours Continueously for 7 days. | ||||||
| 2.00 | Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. (i) On motor side 3 core flat joint less copper cable of size 6.00 mm^2 ( From Switch & Starter to Motor) pump installed in the bore. | 60 | Mtrs. | 560 ₹33,600 Lowest | 565 ₹33,900 | 600 ₹36,000 |
| 3.00 | Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge. | 1 | Job | 16,000 ₹16,000 Lowest | 16,500 ₹16,500 | 16,800 ₹16,800 |
Tender Value
₹3.7 L
EMD Value
₹7,406
Closing Date
24 Aug 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Shahpur
(Sub Head - Supply and Errection of Submersible pumping machinery Set 25 HP with allied accessories ).
2026_HPIPH_141251_1
SHP/KNG15-754/2026-4397-4447 dt. 14/08/2026
Open Tender
Civil Works
Item Rate
30 days
Shahpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹350
Executive Engineer
₹7,406
7 Sept 2026
14 Aug 2026
24 Aug 2026
14 Aug 2026
24 Aug 2026
14 Aug 2026
14 Aug 2026 - 24 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of submersible pumping set of /KSB/ Kirloskar/ Calama/Jyoti / BS / Sabar pump make conforming to BIS; 8034-1976 (latest with uptodate ammendments) fitted with bronze impellers/suitable for lifting clear water ( latest with upto date ammendments ) fitted with bronze impellers suitable. The pump should be fitted with free flow impellor of bronze/ suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear suitable for operation on 220 volts single phase 50 HZ . AC supply minimum class-B insulation, the power of motor 10% in excess of minimum power required by the pump in complete range of (-) 25% & (+) 40% of duty point head. . It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- | 1 | Job | - | - |
| 1.01 | Total Head = 350.00 Mtr. (ii) Discharge required from each pump = 3.50 LPS each set, (iii) No. of pump required = 1 Nos. Set, (iv) Dia of Rising main = 50 mm dia, (v) No of working hours per day = 8.00 Hours, (vi) R.P.M. of pumping set. = 2900 RPM (or to be specified by the tenderer), (vii) Test Run = 20 Hours Continueously for 7 days. | - | - | - | - |
| 2 | Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. (i) On motor side 3 core flat joint less copper cable of size 6.00 mm^2 ( From Switch & Starter to Motor) pump installed in the bore. | 60 | Mtrs. | - | - |
| 3 | Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge. | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
Form6and8.pdf
Tender Documents • 0.56 MB
BOQ_209653.xls
BOQ • 0.27 MB
Termsandconditions.pdf
Tender Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .