Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L1 | Accepted-AOC ACCEPTED LOWEST BIDDER L1 | |
| 2 | L2₹21.5 L+₹1.3 L (6.29%)Rejected-Finance | L2 | Rejected-Finance Being rejected L2 | |
| 3 | L3₹21.8 L+₹1.6 L (7.94%)Rejected-Finance 18 MOTI BAGH BABYAL ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being rejected L3 | |
| 4 | L4₹24.4 L+₹4.2 L (20.8%)Rejected-Finance | L4 | Rejected-Finance Being rejected L4 | |
| 5 | L5₹26.3 L+₹6.1 L (30.2%)Rejected-Finance A 23 TRIBUNE COLONY AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Being rejected L5 |
Tender Value
₹34.0 L
EMD Value
₹67,960
Closing Date
29 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI ABHINANDAN KUMAR MISHRA EE IDSE
GE (SOUTH) AMBALA CANTT
CA NO GE SOUTH AMB 65 2023 2024 ADDN ALTERATION TO BLDG NO HT 04 (OR LIVING) OF 2 CORPS OMC UNDER GE (SOUTH) AMBALA CANTT
2024_MES_635287_1
GE(SOUTH)/AMB-65/2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹67,960
Yes
27 Mar 2024
1 Jan 2024
31 Jan 2024
1 Jan 2024
29 Jan 2024
16 Jan 2024
1 Jan 2024 - 15 Jan 2024
Amount
Taking down chowkats or frames with shutter, area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed. (Note – The qouted rate shall be deemed to include for fixing of hold fast in the same opening irrespective of position of hold fasts and no separate item for making good of hold fasts shall be paid).
Taking down chowkats or frames with shutter, area exceeding 1.50 Square metre but not exceeding 4 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed. (Note – The qouted rate shall be deemed to include for fixing of hold fast in the same opening irrespective of position of hold fasts and no separate item for making good of hold fasts shall be paid).
Taking down shutter of any descritption exc 1.00 sqm each but not exc 2.00 sqm each including removal from site complete all as specified and directed.
Supply and fixing of steel window box type, using ERW hollow 'P' section, factory made, comprising double frame for and including gauged and glazed skelton shutter, 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 of HQ CE Chandigarh Zone as applicable including PCC (C-O ,1:3:6 using 12.5 graded stone aggregate) bed blocks for hold fasts including taking down existing window any type complete all as specified and directed. Note: (i) For the purpose of measurement & payment double shutter both glazed and gauzed with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill 10 mm square bar irrespective of whatever shown on drawings. The pattern of grill shall be all as shown on drawing. (iii) Glazing, wire mesh and painting shall be measured and paid for separately.
Supply and fixing of steel windows or ventilators, fixed type, with glazing bars including PCC (C-O, 1:3:6 using 12.5 graded stone aggregate) bed blocks for hold fasts, including taking down existing ventilators any type complete all as specified and directed
Supply and fixing of sheet glass 3mm thick, ordinary quality, in square not exceeding 0.5 Square metre each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters complete all as specified and as directed.
Supply and fixing of pressed steel frames for doors of size 125 x 60mm, 1mm thick, with one or more rebates including, hold fasts of 25mm x 4mm FI, 25cm long, 6 Nos in each chowkhat, necessary lugs, 3 Nos 100 mm MS butt hinges medium weight, cold rolled, welded for each shutters of frame, lock strike plate, including sanding, tarring backs of chowkhats, PCC 1:3:6 type C-0 filling in frame, 2 Nos 12 mm dia MS tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and as directed.
Supply and fixing of pressed steel frames for doors of size 165 x 60mm, 1mm thick, with one or more rebates including, hold fasts of 25mm x 4mm FI, 25cm long, 6 Nos in each chowkhat, necessary lugs, 3 Nos 100 mm MS butt hinges medium weight, cold rolled, welded for each shutters of frame, lock strike plate, including sanding, tarring backs of chowkhats, PCC 1:3:6 type C-0 filling in frame, 2 Nos 12 mm dia MS tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and as directed.
Supply and fixing of 2nd class (hollock) factory made 35mm thick glazed skelton door shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in para 8.24(a) of SSR 2009 (Part I), complete all as specified and directed.
Supply and fixing of galvanized steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple complete all as specified and as directed.
Supply and fixing of factory made flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, ISI marked complete all as specified and as directed.
Supply and fixing of factory made 35 mm thick, second class hard wood rail and style, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commrcial veneering on both faces ace, size of rails and stiles as per IS 1003 (part-I) kiln seasoned and chemical pressure treated complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Supply and fixing of butt hinges, medium weight, cold rolled, mild steel, ISI marked 100 mm size complete all as specified and directed.
Supply and fixing of extruded aluminium alloy handles, fabricated type, anodized of size 150 mm long complete all as specified and directed.
Supply and fixing of aluminum anodized, barrel tower bolts of extruded section 200mm long complete all as specified and directed.
Supply and fixing of 300 mm aluminum anodised sliding door bolt, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminum alloy, complete all as specified and as directed.
Supply and fixing in repair of mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete fixed to stone/ concrete chowkats with flat iron 40x3 mm size 75 cm long with necessary bolts, etc. complete all as specified and directed.
Supply and fixing in repair of galvanized steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple complete all as specified and as directed.
Supply and fixing in repair of sheet glass 3mm thick, ordinary quality and glazing with oil putty, in square not exceeding 0.5 Sqm each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing debries out side defence area complete all as specified and directed.
Material and labour for premium quality, dark shade vitrified ceramic tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed as in neat, neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) complete all as specified and directed.
Material & labour for premium quality coloured designed glazed ceramic tiles (600x300 x 7 to 8mm thick) as in vertical surfaces such as dado, skirting etc vertical surface, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the shade of tiles over and including rendering 10mm thick in cement plaster 1:3 finished rough surface to receive tiles complete all as specified and as directed.
Demolition of old brick masonry built in cement mortar of any description including all quoins, archs, pillars etc complete all as specified and directed.
Material and labour for brick work with sub class 'B' (old size) bricks, straight or curved on plan, exceeding 6 metre mean radius built in CM 1:6 complete all as specified and directed.
Supply and fixing in repair of CP bib tap screwed down high pressure, long body, cast copper alloy, chromium plated with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union, complete all as specified.
Supply and fixing of semi perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 476 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick ( galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiliing using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2mm. galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge including dismantling existing ceiling boards/slabs etc; any thickness including cover fillets complete all as specified and directed. NOTE : - Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed.
Taking down cement plaster of any description and in any position including raking out joints, hacking for key, scrubbing down with water etc of any thickness complete all as specified and as directed.
Material and labour for 15mm thick rendering in cement mortar (1:4) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 15mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rough cast plaster with and including 15mm thick rendering in CM 1:3 on brick wall or concrete surface as specified in clause 14.22 of SSR Part-I complete all as specified and directed. Note:-(i) After applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. (ii) The mix of cement and sand shall be made slightly loose/wetter than normal for rendering to ensure that larger aggregates are thoroughly covered. (iii) Contractor's quoted rate shall include all above provisions and no extra shall be admissible on this account.
Material and labour for preparation of exposed brick wall surface by cleaning the surface wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day. NOTE : - Further treatment over the surface so achieved will be carried out only after approved of the same by GE.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer on walls complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with hand roller, over a coat of alkaline resistant primer over a coat of wall care putty not less than 1mm thick as per manufacturer's instruction complete all as specified and directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls by washing rubbing and applying one coat of cement base paint complete all as specified and as directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls by washing rubbing and applying one coat of oil bound distemper complete all as specified and as directed.
Material and labour for preparation of old wood and wooden based surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel complete all as specified and directed.
Material and labour for preparation of old painted steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint (any tint/shade) complete all as specified and directed
Supply and fixing in repair of aluminium pre coated of choice colour designed type 25 mm tubular rod in curtain rod, 1.6mm fancy type including PVC golden colour brakets, latto and wall to wall socket etc., complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for 50mm thick PCC (1:3:6) type C-1 using 20mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with 85/25 grade bitumen and sand (1:3 ratio) mixture etc complete all as specified and directed.
Supply and fixing of aluminium alloy anodized (powder-coated) partition ( Area of each panel not exceeding 1.5 Sqm each) with frame of size not less than 100 mm x 44.4 mm x 2 mm including packing with rubber gasket, standard aluminium beading around both sides including 6mm thick plain coloured bakelite sheet or acrylic boards, prelaminated both side with one side decorative choice lamination for fixing in panels of aluminium partition as required including taking down existing partion any type complete all as specified and directed.
Supply and fixing of aluminium alloy anodized (powder-coated) door frame and shutters with hollow aluminium anodized sections and thickness of section exec 1.5mm thick as specified including aluminium alloy anodized snap type beads, dish type door handles, glazed clip, jointing cleats, rubber packing, gasket, dead lock 4 levers, 02 Nos aluminium alloy anodized tower bolts to each leaf etc. including fixing frame to wall/RCC members with rawl plugs etc including taking down existing door any type complete all as specified and directed. Sections of frame and door shall be as follows : - (a) Door Frame single groove 101.6 mm x 44.45 mm x 2.15mm thick (b) Shutter top 47.62 mm x 44.45 mm x1.95 mm thick. (c) Shutter bottom 114.30 mm x 44.45 mm x 2.1 5mm thick. (d) Shutter vertical 85 mm x 44.45 mm x 1.80 mm thick. (e) Shutter middle 83.5 mm x 44.45 mm x 2.40mm thick. (f) Gauging clip weighing not less than 0.097kg/metre. Note :- Glass pane shall be measured and paid separately.
Supply and fixing of aluminium alloy anodized (powder-coated) window frame with double shutters open able type, with aluminium sections as specified for casement windows with double shutters including aluminium alloy anodized snap type beads, handles, stainless steel hooks and eyes, aluminium anodized barrel tower bolts, glazing clips, joint cleats, rubber packing, gaskets etc for series-B “ Jindal” section numbers for casement window including taking down existing window any type complete all as specified and directed comprising of followings :- (a)Frame of section 101.6mm x 44.45mm x 2.10 mm thick and section for shutter 47.62 mm x 44.45 mm x1.95 mm thick. (b) Mullion 53 mm x 52 mm x 2 mm thick not less than 1.065 kg/mertre. (c) Glazing clip weighing 0.259kg/mtr. (d) Window shall be provided with 02 Nos. of tower bolt for single leaf and 03 Nos. of tower bolts for double leaf. Tower bolts shall be aluminium alloy anodized weighing 0.302kg/mtr. Handles shall be aluminium anodized ‘D’ type handle of size 98 mm and thickness 2.37mm weighing 0.875kg/mtr and 01 no for each open able leaf. Notes :- Glass pane shall be measured and paid separately.
Supply and fixing of 5.0 mm thick tinted glass in square exceeding 0.5 sqm in each pane with heat reflecting properties, black glass file of 50 micron, fixed to aluminium frame with glazing clips, etc., complete all as specified and directed.
Supply and fixing of anodised aluminium grill of diamond size 100x100mm of dia 6mm including necessary joining cleats, anodised aluminium snap beading screws, complete all as specified and directed.
Supply and fixing of 5 to 8 mm thick plain colour PVC sheet hollow interlocking wall panelling of width 250 mm for wall panelling inclusive of fixing on wall with screws and solvent alongwith PVC 'U' and 'L' beading at corner and end portion where ever required of matching colour including taking down of existing wall lining, board or insulation board/panelling including cover fillets of any type and thick complete all as specified and as directed. NOTE : - Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed.
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 25mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 51.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 51.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 51.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fixing of modular switches, one way, 5 amps one module, 230V, AC supply, ISI marked complete all as specified and directed.
Supply and fixing of modular switches, one way, 15 Amps, one module, 230 volt, AC supply, ISI marked complete all as specified and directed.
Supply and fixing of modular socket outlet 5 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fixing of modular socket outlet 2 in 1, 5 & 15 amps, 3 pin, 2 module, 230 volts complete all as specified and directed.
Supply and fixing of ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing of modular fan regulator step type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing of heavy duty exhaust fan metallic body 300 mm sweep with and including louvers, electric, single phase 1400RPM, 240 volt 50 Hz complete and making suitable hole in existing cement concrete / brick walls built in cement mortar 1:4 and removing unserviceable/loose/broken debris upto 500m distance and making good the disturbed surfaces to match with the existing surface including plastering as required & finishes including grouting four Nos rag bolts, nuts & washers and connecting with 3 core copper flexible cable of size 23/0.0076 including testing & commissioning after installation at site complete all as specified and directed.
Material and labour for taking down ceiling fan any type, taking in safe costudy and refix the same after completion of repair work including servicing, provision of cable from ceiling rose and painting with synthetic enamel paint by sparying including filling cavities with filler, one coat after cleaning all dust all as specified and directed.
Supply and fixing LED luminaries of capacity 20 watt integrated aluminium batten with including oppal diffuser complete connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light complete all as specified and directed.including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of LED bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing recess/ surface mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing in repair bracket for security light made up of 25mm dia, 0.90 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing of LED security light luminaire 30 watt should lumens not less than 100 lumens per watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W each and having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply, installation, testing of SPN distibution board 8 way,double door , IP 43, as per IS 8623 including 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of TPN distibution board 4 way, double door , IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply and fixing of MCB triple pole and neutral, 415 volts, 50Hz , breaking capacity 10KA, 'C' curve 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of in repair of sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 20 Amps, 'B' curve, 240 volts complete all as specified and directed.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4.0 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6.0 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Supply and fixing of LT 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, four twin core cable flat or circular of size 16 Sqmm including all incoming and outgoing connection with proper size of thimble etc. including taking down existing service cable any size and type complete all as directed and specified.
Taking out of unserviceable earthing and material and labour for earthing and material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and as directed. Note :- (i) Earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. (ii) On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
NOTE:- Amount of credit of Rs. 53,389.00 for retrieved materials is mentioned in Schedule of Credit Page No 21(R) & 22(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
Ashwani Kumar
Gupta Enterprises
CHIBBER and SONS
M/s AVINASH CHANDER GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .