| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-Finance | L1 | Accepted-Finance Admitted | |
| 2 | L2₹21.5 L+₹3.0 L (16.5%)Accepted-Finance 19 RAMESH NAGAR LALIT APARTMENT JAI BHAVANI MATA ROAD VILLAGE TOWN AMBOLI VILLAGE CITY ANDHERI WEST MUMBAI | L2 | Accepted-Finance Admitted |
Tender Value
Refer Docs
EMD Value
₹44,313
Closing Date
1 Sept 2020, 12:00 pmClosed
Sr. CE (E) BSNL Mumbai
O/o Sr. CE (E) A Wing Gr Flr Admin Bld BSNLSantacruz Mumbai
O and M of EMS Telecom Factory and Staff Qrtr Colony Deonar Mumbai
2020_BSNL_576358_1
NIT No.1300/CEEM/2020-21/NIT/35
Open Tender
AMC/ Maintenance Contracts
Item Rate
730 days
Mumbai
Please refer Tender documents.
12 documents required · 12 mandatory
₹590
AO (F and A) BSNL
₹44,313
2 Sept 2020
8 Aug 2020
2 Sept 2020
8 Aug 2020
1 Sept 2020
8 Aug 2020
Amount
Round the clock Operation & Maintenance of various electromechanical services as per details given in relevant sections by deploying the required staff including specialized manpower and by arranging required tools and plant etc to keep all the services operational upto the required standards. (For Telecom Factory only) A) Services included are: (1) EI & Fans (2) Compound Lighting (3) Substation (4) Pumps (5) Electrical Panels, DB's (6) Window & Split AC units (7) Heating & cooling appliances (8) Fire Extinguishers Contractors to take all steps to undertake preventive / special maintenance and testing to keep the system at optimum working condition. Size of various services is given in Section - I B) Minimum Staff Required: Wireman (semiskilled): 1 No. per shift into 3 shifts (shift as decided by Engineer in charge) Note: If more persons are required for satisfactory operation/maintenance, the same shall be arranged by the firm at no extra cost as and when required.
SH- II (Petty Maintenance work of EMS):- Supply of following material for repairing & attending petty maintenance work by engaging manpower available with above operation work(in SH-I) or with extra skilled manpower if required for repairing of Substation, HT/LT panels, capacitor panels, existing wiring work like fluorescent fitting, ceiling fans, wall/pedestal fans, Main board, Sub Main board, Compound Lighting, water pumps & switchgears, Geysers, Split AC, water coolers, etc i/c dismantling, connection, fixing, testing etc as required (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory) (A) EI & Fans: switch - 6 amps
switch 16 A
socket outlet - 5 pin 6 A
socket outlet - 6 pin, 16 A
Two way switch - 5 A
Copper Choke - 40W
T.L. Starter
Side Holder
Capacitor - 2.5 MFD/3.5 MFD
Angle Holder
Batten Holder
Fan regulator - resistance type
Fan regulator - electronic step type - 150W
Bell Buzzer
Bell push switch
ceiling fan canopy
Fancy fitting canopy
ceiling rose
36W 4' Tube Rod
Electronics choke for 36W Fluorscent Tube
DP switch - 32 A
2 Gang Box Domestic
4 Gangbox (double domestic)
3 mm thick hylam sheet
Backelite base cover plate for holding single tube light side holder
Backelite based cover plate for holding double tube light side holder
3 core 0.5 sqmm PVC insulated & PVC round sheathed multicore copper conductor flexible cable (for connection between ceiling rose to fitting)
Overhauling and servicing of ceiling fan/exhaust fan including disconnnection & dismantling, cleaning, replacing worn out parts like bearing, quarter pin, lock nuts, rubber bush, refixing, etc.as required.
Rewinding of ceiling fan/exhaust fan including disconnnection & dismantling, replacement of faulty bearings, oiling/greasing, etc.as required.
Rewinding of exhaust fan including disconnnection & dismantling, replacement of faulty bearings, oiling/greasing, etc.as required.
Installation, testing and commisioning of ceiling fan, including wiring the down rods of length (upto 150 cm) with 1.5 sq. mm FR PVC insulated, copper condutor, single core cable etc. as required.
ITC of prewired flourscent flourscent tube rod box fitting on wall/ceiling, on wall / ceiling etc. as required.
(B) LT Panels, Main Board & DB's: Single pole - upto 32 A
SPN - upto 32A
2 pole RCCB - 40 A, 300mA
SPN MCB - 40A
TPN MCB- 63A
Isolator 4P - 125A
HRC fuse - 40 A
Bolted type HRC Fuse - 36A - 63A
Bolted type HRC Fuse - 80A - 125A
Bolted type HRC Fuse -160A - 200A
Bolted type HRC Fuse -250A
DIN type HRC Fuse - 125A
DIN type HRC Fuse - 160A - 200A
DIN type HRC Fuse - 250A
Lugs copper tube terminal - sq.mm -16
Lugs copper tube terminal - sq.mm -25
Lugs copper tube terminal - sq.mm -35
Lugs Aluminium tube terminal sq.mm -35
Lugs Aluminium tube terminal sq.mm -50
Lugs Aluminium tube terminal sq.mm -70
Lugs Aluminium tube terminal sq.mm -95
Lugs Aluminium tube terminal sq.mm -120
Lugs Aluminium tube terminal sq.mm -150
Lugs Aluminium tube terminal sq.mm -185
(C) Compound Light: 35 watt LED Lamp
45 watt LED Lamp
Porcelain holder suitable for housing 35W/45W CFL/LED lamp
connector (10sq.mm) - 4 way
SP MCB - 6A
Ignitor - 70W/125W
Ignitor - 150W
Capacitor - 7 MFD (Keltron/Junkar/ Crompton /L&T/ Universal Electric/ Usha/ Asian/Epcos)
Capacitor - 10 MFD
Perplex luminaire cover - Fibre
Pole box clamp
Weather proof SMC (sheet moulding compound) Pole junction Box of nominal size- 240 x 130x 110mm (inner) / 280x170x130mm (outer) with hinge, gasket, locking arrangement canopy, 32 A 4 way connector, earth stud, neutral link, din channel, SP MCB-6A, C series complete as reqd.
24 Watts waterproof LED Street Light fittings on exisitng GI pole with suitable GI bracket, accessories etc. with testing commissioning as required. (Make - M/s Philps / Bajaj / Sysca/ Kalki)
(D) PUMP: Servicing & refixing of mono block pump i/c checking of leakage of pump , tightening of gland and Gland dori , checking & cleaning of foot valve , checking and attending fault of contactor relay push button etc as reqd. (a) upto 7.5HP
(b) 10 HP to 15 HP
SITC of following components in LT panel i/c wiring of device, removing of faulty parts as reqd. LED type phase indicators: R-Y-G
Ammeter (0-50A)
Voltmeter (0-500V)
SP MCB - 6A
Timer switch for compound light
TPN MCB-63A
HRC Fuse -63A
HRC Fuse -32A
Repairing of DOL starter with replacement of contactor coil, wiring of circuits for ON OFF indication, as reqd.
Pdg. Plumbing repairs to pump room piping including opening of pipe from flange, lifting, refixing, with water tight joint, replacement of following parts as reqd. Foot valve(50mm dia) - Gun metal
50mm dia C-PVC pipe including bend, brass threaded coupling, etc. upto 4 Mtrs)
Non-Return Valve (50mm dia)
(E) SUBSTATION: Carrying out Servicing & Testing of MEI make 11 KV HT Panel which inculdes cleaning of complete VCB (03 Nos. of 400A, type VR-5) with CRC-2-26, lubrication of mechanisms, checking ON-OFF operation, megger testing, checking of contact resistance, checking ON-OFF tripping timing, CT, PT, IDMT & earth fault relay testing, parameters as per standards as reqd.
Carrying out preventive maintenance of 11KV/433V, 3000 KVA dry type transformer which incldes cleaning of complete transformer, tightening of HT LT connection, megger test, checing of IR value, checking of contact resistance, testing parameters as per standards as reqd.
Carrying out preventive maintenance of LT ACB which includes cleaning of contacts by CRC-2-26, lubrication of mechanism, checking ON OFF operation, IR value, contact resistance, electrical & mechanical interlock complete as reqd. A) 800A - 1600A (Seimens, model- 3WT8, WL1600H)
Carrying out preventive maintenance of capacitor panel which includes cleaning of contacts by CRC-2-26, incomer MCCBs, outgoing SDFU, contactors, checking of all capacitor currents, tightening all connections, Testing of APFC relay for operation in Auto & Manual mode as reqd.
Carrying out testing of earth electrodes and measurement of earth resistance of earthing as reqd.
Supply & fixing of under voltage coil with proper alignment of mechanism, checking of electrical interlocking of LT ACB mechanically & electrically as reqd.
Supplying & fixing A.C. LED tyoe indicating lamps for LT Panels as reqd. (colours: Red, Yellow, Green)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
(F) AC Units (Window/split/ductable split upto 5.5TR): ITC of 1.5 TR high wall mounting type Split A.C. units with mounting fitting indoor and outdoor units at their respective locations by using necessary hardware, charging of gas, copper piping including polythene thermal insulation and cabling etc. complete as required.
Providing and installing additional copper piping suitable for above AC units where ever required i/c insulation, wiring, additional gas charging, PVC pipes etc. as reqd. Copper tube 1/4" (i/c Brazing )
Copper tube 1/2"(i/c Brazing )
3 core x 2.5 sq.mm. PVC insulated Cu. conductor flexible cable
Polythene foam tubing for insulation
Providing & fixing of heavy guage rigid PVC pipe of 19mm dia. for extending drain connection uptp drain point by cutting the wall & making goodthe same complete as reqd.
Providing & fixing of powder coated, galvanised bracket (ready made) on wall with suitable coach bolts for mounting outdoor condenser of 1.5 TR split AC unit etc. as required. (1 set consits of 2 nos. bracket)
Attending gas leakage in 1.5TR split AC /5.5TR Ductable split AC with complete leakage test, pipe brazing, terminals, pressure testing, etc. as reqd.
Gas Charging R-22 Gas in AC units
R & R SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .