| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1752.2 CrAccepted-AOC | ₹1752.2 Cr Quoted ₹17.5 Cr | L1 | Accepted-AOC Being lowest and accepted |
| 2 | L2₹17.7 CrRejected-Finance | ₹17.7 Cr | L2 | Rejected-Finance Not being Lowest |
| 3 | L3₹18.4 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹18.4 Cr | L3 | Rejected-Finance Not being Lowest |
| 4 | L4₹19.0 CrRejected-Finance | ₹19.0 Cr | L4 | Rejected-Finance Not being Lowest |
| 5 | L5₹20.8 CrRejected-Finance | ₹20.8 Cr | L5 | Rejected-Finance Not being Lowest |
| Sl No | Description | Qty | Unit | SVS PROJECTS L6 | CH.VEERARAGHAVULU CONSTRUCTION PVT LTD L5 | Komal Buildcon Pvt. Ltd. L2 | anjaliinfratech L1 | SOOD ASSOCIATES PVT LTD L7 | jd constructions L4 | RAGHUSONS INFRA ENGINEERING PVT. LTD L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| .10Schedule "A" Part – I (BUILDINGS & STRUCTURES) | ||||||||||
| 1.00 | Lump Sum price worked out by the contractor for 'Buildings & Structures', as listed in Schedule 'A' Part-I. | 1 | Each Job | 12,70,84,028 ₹12.7 Cr | 12,25,53,451 ₹12.3 Cr | 10,10,91,000 ₹10.1 Cr | 10,21,57,633.16 ₹10.2 Cr | 13,80,49,000 ₹13.8 Cr | 10,32,65,000 ₹10.3 Cr | 10,32,65,000 ₹10.3 Cr |
| 2.00 | Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II. | 1 | Each Job | 29,81,797 ₹29.8 L | 41,42,964 ₹41.4 L | 29,24,077.08 ₹29.2 L | 19,37,085.7 ₹19.4 L | 32,34,206.47 ₹32.3 L | 38,23,506.5 ₹38.2 L | 35,44,335.86 ₹35.4 L |
| 3.00 | Lump Sum price worked out by the contractor for 'AREA DRAINAGE', as listed in Schedule 'A' Part-III. | 1 | Each Job | 27,32,074.96 ₹27.3 L | 24,61,577 ₹24.6 L | 23,90,751.95 ₹23.9 L | 18,56,115.48 ₹18.6 L | 27,50,650.09 ₹27.5 L | 25,70,701.02 ₹25.7 L | 25,70,701 ₹25.7 L |
| 4.00 | Lump Sum price worked out by the contractor for 'SEWAGE DISPOSAL', as listed in Schedule 'A' Part-IV. | 1 | Each Job | 3,15,667.3 ₹3.2 L | 3,36,967 ₹3.4 L | 2,67,682.02 ₹2.7 L | 2,09,188.3 ₹2.1 L | 2,86,419.76 ₹2.9 L | 3,16,753 ₹3.2 L | 2,67,682 ₹2.7 L |
| 5.00 | Lump Sum price worked out by the contractor for 'ROAD/PATH/CULVERT AND HARD STANDING', as listed in Schedule 'A' Part-V. | 1 | Each Job | 50,57,812.56 ₹50.6 L | 51,96,765 ₹52.0 L | 38,46,973.29 ₹38.5 L | 37,03,514 ₹37.0 L | 44,26,087.55 ₹44.3 L | 41,36,530.42 ₹41.4 L | 41,36,530 ₹41.4 L |
| 6.00 | Lump Sum price worked out by the contractor for 'EXTERNAL WATER SUPPLY', as listed in Schedule 'A' Part-VI. | 1 | Each Job | 1,86,086 ₹1.9 L | 2,10,079 ₹2.1 L | 1,26,663.96 ₹1.3 L | 1,46,700 ₹1.5 L | 2,24,195.21 ₹2.2 L | 1,26,663.96 ₹1.3 L | 2,59,190 ₹2.6 L |
| 7.00 | Lump Sum price worked out by the contractor for 'EXTERNAL ELECTRIC SUPPLY', as listed in Schedule 'A' Part-VII. | 1 | Each Job | 8,03,396.08 ₹8.0 L | 8,20,173 ₹8.2 L | 9,17,655.75 ₹9.2 L | 9,50,000 ₹9.5 L | 11,65,422.8 ₹11.7 L | 9,17,655.75 ₹9.2 L | 13,19,329 ₹13.2 L |
| 8.00 | Lump Sum price worked out by the contractor for 'DG SET', as listed in Schedule 'A' Part-VIII. | 1 | Each Job | 40,756 ₹40,756 | 41,728 ₹41,728 | 38,811.6 ₹38,811.60 | 50,000 ₹50,000 | 53,171.89 ₹53,171.89 | 40,800 ₹40,800 | 1,39,329 ₹1.4 L |
| 9.00 | Lump Sum price worked out by the contractor for 'LIGHTENING PROTECTION', as listed in Schedule 'A' Part-IX. | 1 | Each Job | 2,62,993 ₹2.6 L | 3,02,169 ₹3.0 L | 2,13,021.1 ₹2.1 L | 3,20,000 ₹3.2 L | 2,27,932.58 ₹2.3 L | 2,13,021.1 ₹2.1 L | 3,19,029 ₹3.2 L |
Updated dates
Tender Value
₹18.6 Cr
EMD Value
₹12.6 L
Closing Date
24 Feb 2026, 6:00 pmClosed
Chief Engineer (Navy), Visakhapatnam
Chief Engineer (Navy), Visakhapatnam
DEMOLITION AND RECONSTRUCTION OF DEFICIENT STORAGE ACCOMMODATION AT BASE VICTUALLING YARD VISAKHAPATNAM
2025_MES_743752_1
85462
Open Tender
Civil Works
450 days
VISAKHAPATNAM
As per NIT
13 documents required · 13 mandatory
₹300
Yes
GE(P) No.3 Chief Engineer (Navy), Visakhapatnam
₹12.6 L
Yes
13 May 2026
9 Dec 2025
3 Mar 2026
9 Dec 2025
24 Feb 2026
16 Feb 2026
Schedule "A" Part – I (BUILDINGS & STRUCTURES)
Lump Sum price worked out by the contractor for 'Buildings & Structures', as listed in Schedule 'A' Part-I.
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II.
Lump Sum price worked out by the contractor for 'AREA DRAINAGE', as listed in Schedule 'A' Part-III.
Lump Sum price worked out by the contractor for 'SEWAGE DISPOSAL', as listed in Schedule 'A' Part-IV.
Lump Sum price worked out by the contr
actor for 'ROAD/PATH/CULVERT AND HARD STANDING', as listed in Schedule 'A' Part-V.
Lump Sum price worked out by the contractor for 'EXTERNAL WATER SUPPLY', as listed in Schedule 'A' Part-VI.
Lump Sum price worked out by the contractor for 'EXTERNAL ELECTRIC SUPPLY', as listed in Schedule 'A' Part-VII.
Lump Sum price worked out by the contractor for AIR CONDITIONING', as listed in Schedule 'A' Part-VIII.
Lump Sum price worked out by the contractor for 'DG SET', as listed in Schedule 'A' Part-IX.
Lump Sum price worked out by the contractor for 'LIGHTENING PROTECTION', as listed in Schedule 'A' Part-X.
Lump Sum price worked out by the contractor for 'LIFT', as listed in Schedule 'A' Part-XI.
Lump Sum price worked out by the contractor for 'FIRE FIGHTING SYSTEM', as listed in Schedule 'A' Part-XII.
Lump Sum price worked out by the contractor for 'FIRE ALARM SYSTEM', as listed in Schedule 'A' Part-XIII.
Lump Sum price worked out by the contractor for 'ARBORICULTURE', as listed in Schedule 'A' Part-XIV.
Lump Sum price worked out by the contractor for 'RAIN WATER HARVESTING', as listed in Schedule 'A' Part-XV.
Lump Sum price worked out by the contractor for 'PILE FOUNDATION', as listed in Schedule 'A' Part-XVI.
Lump Sum price worked out by the contractor for 'WATER COOLER', as listed in Schedule 'A' Part-XVII.
Lump Sum price worked out by the contractor for 'AVIATION LIGHT', as listed in Schedule 'A' Part-XVIII.
Lump Sum price worked out by the contractor for 'INTERNAL WATER SUPPLY' , as listed in Schedule 'A' Part-XIX.
Supply & Lay cable PVC insulated PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calmps spacers bolts nuts etc all as spcidied and as directed
SEWAGE DISPOSAL
Lump Sum price worked out by the contractor for 'INTERNAL ELECTRIFICATION', as listed in Schedule 'A' Part-XX.
M&L for construction of RCC Septic tank for 50 USERs designed to carry sewage and sullage water, excavation in any type of soil, PCC exceeding in ordinary soil foundation in PCC 1:2:4 brickwork in 1:4:8 below foundation, RCC M-30 Design Mix in walls, Base slab, baffle walls and Roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete all as specified and as directed.
ARBOROCULTURE
Supply & Planting Korean carpet grass by piece turfing incl preparion of ground complete all as specified and as directed.
Supply only appoved loose soil/sweet earth best quality for plant complete all as specified and as directed.
Supply only approved vermi compost of the best quality complete all as specified and as directed.
M&L for construction of Soakage well of 50 USERs cpacity, excavation , in any type of soil, foundation in PCC 1:4:8 walls of honey combed masonery with RCC cover slab in M30 cover, interconnecting pipes of RCC complete filled with brick bats complete all as specified and as shown in drawings and as directed. size 3.00m dia X 3.00m depth complete all as specified and as directed.
Supply & Planting Ashoka Plant including preparation complete all as specified and as directed.
Supply & planting Royal palm tree plant including preparation complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Schedule "A" Part - XXI : [Miscellaneous Items]
Incoming:
a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 250 A breaking capactiy 50kA, Manual draw out type - 01 No
Outgoing:
b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A breaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 02 Nos. (Bldg & Spare).
c) MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A breaking capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 No. (DG AMF Panel & Spare).
d) MCCB AC 3 Phase 415 V, 50H z 4 pole 100 A breaking capactiy 35kA with adjustable type thermal and magnetic setting relays - 01 Nos (APFC).
e) MCB TPN AC 3 Phase 415 V, 50 Hz 4 pole 20 A capactiy 10kA - 01 Nos(Pump)
f) Multifunctional Panel meter to measure voltage, current, frequency, power factor, KWH, etc with all connected CTs of each breakers.
g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers.
LT FPB made out of CRCA sheet 3 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 400 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Main LT Panel Bldg-01).
Incoming:
a) MCCB AC 3 Phase 415 V, 50 Hz 4 pole 200 A breaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming)
Outgoing:
b) MCCB AC 3 Phase 415 V, 50H z 4 pole 63 A breaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 03 Nos (2 Nos Lift & spare).
c) MCCB AC 3 Phase 415 V, 50 Hz 4 pole 100A breaking capactiy 35kA with adjustable type thermal and magnetic setting relays - 02 Nos(AC& spare ).
d) MCB SPN AC 1 Phase 230 V, 50 Hz 2 pole 10 A capactiy 10kA - 02 Nos(Fire Alarm & spare)
e) MCB TPN AC 3 Phase 415 V, 50 Hz 4 pole 20 A capactiy 10kA - 03Nos(Street light, High Mast light & Booster Pump)
f) Timer switch controller set with contactor and circuit breaker
g) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs
h) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply of approved manure (cow dung) complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Supply, Install, testing & commissioning of Galvanised Steel high mast lightning system of 12.5 meter in two section , 3mm section thickness, top dia 150mm, bottom dia 340mm, with 2/3 wire rope system and its accessories. System is suitable for loading 04 Nos 100 W LED lights etc all as specified and directed.
EXTERNAL WATER SUPPLY
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplasic of size 205 x 255 x 112mm with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as PVC connector heavy duty 32Amps,4 way for cable with necessary fixing arrangemets and with cable glands, etc all as specified and directed.
M&L for valve chamber of internal size 1.0x1.0x1.0m comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as directed.
PILE FOUNDATION
Supply, install, testing &commissioning Centrifugal pump set, 30m head and 20 LPS discharge, capacity 3 HP with suitable induction motor 1450 RPM,3 phase AC supply complete with base, DOL starter and all accessories including all necessory electrical and watersupply connections complete.
Boring for bored cast-in-situ vertical piles 750mm dia in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed.
Per month per 2 Lifts
Per month per 2 Lifts
Carrying out initial compressive load test on 750mm dia pile as per IS 2911 Part-IV complete all as specified and as directed.
Carrying out initial lateral load test on 750mm dia pile as per IS 2911 Part-IV complete all as specified and as directed.
Carrying out routine compressive load test on 750mm dia pile as per IS 2911 Part-IV complete all as specified and as directed.
DG SET
LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Distribution Panel )
Supply, installation, testing and commissioning of silent diesel engine generating set with accoustic enclosure as per latest CPCB norms 415 Volts 100 KVA, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS-4722, BS-5514/2613/5000 with AMF Panel and including the following (One DG for Mag-1 & one for Mag-2).
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% (v) Frequency regulation +/-1%
(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/ frequency regulation, Fuel filters, Fuel hoses. (vi) Lub oil System: Lubricating oil filter, Lubricating oil pump (vii) Air Intake System: Air intake Manifold, Air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator
(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch. Handling and Operation: Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling. (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms. (xvi) Fuel Tank: Additional fuel tank of capcaity to suit daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure. (xvii) MS pipe line to and from the fuel tank to the DG Set
(A) Alternator: Standard design alternator rated at 100 KVA net output at site after considering de-rating as per site conditions at 0.8 (Lag) power factor AC, 3 Phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/-1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/-1% tolerance. The alternator
(a) Annunciation with indication lamps for: (i) Low lub oil pressure. (ii) High Water Temperature (iii) Engine over speed (iv) Battery low voltage (b) Controls: (i) Load on Indication (ii) Load off indication (iii) Engine start push button (iv) Engine stop push button (v) Fault accept/reset push button
will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722.
(iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building.
(v) Construction details/specification are as follows: (a) Outer body: CRCA sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6mm thick (c) Sound Insulation: As per OEM Norms (vi) The acoustic should be composite in construction and fully assembled integral unit
(vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform (viii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer
(ix) The DG Set should be provided with external emergency stop push button (x) The enclosure should be suitably illuminated by LED lamp fittings
(xi) The noise level should be 75 dba at 1m under free field conditions. (xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen Set Green. The base frame should be painted with epoxy based black shade
(E) The coated rate includes excavation, removing of soft/loose soil and PCC, cement concrete foundation, filling and mass concrete 1:2:4 type B2 using 40mm graded stone aggregate, foundation size not less than 4.6x3.0x0.8m for placing of DG Set complete all as specified and directed by the Engineer-in-Charge.
Notes: 1. The tenderer shall submit the detail, drawing, specification, features to the accepting officer and obtain approval before the procurement of equipment. 2. The tenderer shall make necessary arrangements for predespatch inspection from rep of Accepting Officer. 3. Testing & commissioning certificate shall be obtained from rep. of AO/IEM.
FIRE ALARM SYSTEM
Cutting existing DI/MS pipe line of 150 mm dia for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 150 mm and including Tee for tapping all as specified and directed.
Supplying and laying ductile pipe flange type centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning.
S & F branch pipe of 20 mm dia for hose reel conforming to IS 8090 all as specified and directed.
M&L for valve chamber of internal size 1.0x1.0x1.0m comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm be;ow GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primerincluding necessary earth work and excavation in any type of soil complete all as directed.
Boring for 750mm dia bored cast in situ vertical piles in hard rock using DMC method (Direct Mud Circulation) of boring and getting out and disposal of spoil out side MD land complete all as specified and shown on drawings and as directed.
Supply and install MS rectangular fire bucket stand with shed for four Nos fire buckets duly painted in red colour all as specified and directed.
S & F Star Delta starter fully automatic suitable for 415V AC for 450 LPM 30m head booster pump.
M &L cutting the existing road/ hard standing for laying of pipeline of size (200mm/150mm/100mm) including refiling with soil & making good surface with PCC 1:3:6 C-2 TYPE using 20mm graded stone aggregate all as directed including removing the excavated soil to distance not exceeding 50 mtr all as specified.
S & F hosebox for hose reel of 20 mm size of 30 mtr lengthh including 20 mm gate valve, coupling, branch pipe and nozzle and MS sheet 2 mm thick ( Note : Considered to keep hose reel of 20 mm under relevant iItem) all as specified and directed.
S & F 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
AVATION LIGHT
S & F Aviation obstruction light LED with 10 Watt bulb complete including standard fixing arrangements all as specified and as directed
FIRE FIGHTING SYSTEM
Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit junction boxes of size 205 x 255 x 112 mm for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB SP 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as PVC connector heavy duty 32Amps,4 way for cable with necessary fixing arrangemets and with cable glands, etc all as specified and directed.
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor Fitted inside steel enclosure
AIR CONDITIONING
Supply & fix Voltage Stabiliser for automatic operation , three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480V with output voltage stabilised at 415 with accuracy +- 2.5% and speed of correction 8 Volts per second and of capacity 25 KVA.
WATER COOLER
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type 7 designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +- 2.5% and of capacity 0.5 KVA.
Each Shift of 08 Hours
Carrying out routine Lateral load test on 750mm dia pile as per IS 2911 Part-IV complete all as specified and as directed.
(viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personnel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I.
Carrying out Integrity test on 750 mm dia pile all as per IS2911 Part-IV complete all as specified and as directed. Note fot Item Nos.21 to 25: Test results shall be approved by the CWE. The GE shall intimate CWE before commencing the load test and the test shall be carried out in the presence of the authorised representative detailed by the CWE.
SCHEDULE 'A' PART-XXII: Outsourcing Services for Operation of Lifts for the First Year of the two year Defect Liability Period:
Outsourcing of services for operaion of Goods lifts (2 x 2000 Kgs capacity) of any type and make to serve G+1 floors, during First Year of the two year Defect Liability Period by providing services of One Lift Operator (Semi Skilled) per One Shift/day on excluding all Sundays, Holidays & 2nd Saturdays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge.
Outsourcing of services for operaion of passenger lifts (2 x 2000 Kgs capacity) of any type and make to serve G+1 floors, during Second Year of the two year Defect Liability Period by providing services of One Lift Operator (Semi Skilled) per One Shift/day on excluding all Sundays, Holidays & 2nd Saturdays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge
Notes for Outsourcing Services Items: (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift shall be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non-function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair/replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communic
Outsourcing of services for operaion of Goods Lifts (2 X 2000 Kgs capacity) of any type and make to serve G+1 floors, during First Year after expiry of Defect Liability Period by providing services of ONE Lift Operator (Semi Skilled) per ONE Shift/day on excluding all Sundays, Holidays & 2nd Saturdays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge
Comprehensive mainenance of Goods Lifts (2 X 2000 Kgs capacity) to serve G+1 floors including all connected components of lifts during First Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
ation system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure house keeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
Outsourcing of services for operaion of Goods Lifts (2 X 2000 Kgs capacity) of any type and make to serve G+1 floors, during Second Year after expiry of Defect Liability Period by providing services of ONE Lift Operator (Semi Skilled) per ONE Shift/day on excluding all Sundays, Holidays & 2nd Saturdays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge
Comprehensive mainenance of Goods Lifts (2 X 2000 Kgs capacity) to serve G+1 floors including all connected components of lifts during Second Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
Outsourcing of services for operaion of Goods Lifts (2 X 2000 Kgs capacity) of any type and make to serve G+1 floors, during Third Year after expiry of Defect Liability Period by providing services of ONE Lift Operator (Semi Skilled) per ONE Shift/day on excluding all Sundays, Holidays & 2nd Saturdays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge
SCHEDULE 'A' PART-XXV: Outsourcing Services for Operation of Lifts and Comprehensive maintenance of Lifts for the Second Year after Defect Liability Period:
Comprehensive mainenance of Goods Lifts (2 X 2000 Kgs capacity) to serve G+1 floors including all connected components of lifts during Third Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
(D) Acoustic Enclosure: Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per latest CPCB norms (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
85462_Schedules.pdf
Additional Documents • 0.55 MB
BVY_STRL_DRGS.rar
Additional Documents • 5.17 MB
85462_Tender.pdf
Tender Documents • 4.35 MB
BOQ_832804.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid