Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.5 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹29.3 L+₹1.8 L (6.58%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹31.2 L+₹3.7 L (13.6%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹32.7 L+₹5.2 L (18.9%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹36.1 L+₹8.6 L (31.4%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Dec 2024, 6:00 pmClosed
GARRISON ENGINEER (NAVAL BASE)
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
REPAIRS AND REWINDING OF CEILING FANS, EXHAUST FANS AIR CIRCULATORS AND REPAIRS TO GEYSERS HEATING APPLIANCES AND ALLIED WORKS AT NAUSAINIK VIHAR AREA DOLPHIN PARK AREA AND MISC TECHNICAL BUILDING AT DOLPHIN HILL UNDER GE(NB) VISAKHAPATNAM
2024_MES_682807_1
C/8319/24-25/E8 / Token 69 of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
1 Feb 2025
7 Nov 2024
12 Dec 2024
7 Nov 2024
5 Dec 2024
21 Nov 2024
Amount
Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required after rewinding (if any) complete all as specified and directed. (Note : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed within one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and fan shall be re-fixed at site within 10 days after taking down from site. Any delay after 10 days shall be penalised @ Rs. 100.00 per day for a maximum of 10 days).
All as per Serial item No. 01 above but exhaust fan of 150 to 600mm sweep of any capacity complete ditto.
All as per Serial item No. 01 above but air circulators/ pedestal fan/ wall mounting fan of any sweep and any capacity complete ditto.
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 01 above)
All as per serial item No. 04 above but exhaust fan of 225 to 300mm sweep complete ditto
All as per serial item No. 04 above but exhaust fan of 450 to 600mm sweep complete ditto
All as per serial item No. 04 above but PVC exhaust fan of 150 to 200mm sweep complete ditto
All as per serial item No. 04 above but aircirculator/ pedestal fan/ wall mounted fan of any sweep complete ditto
Supply only ball bearing set of two suitable for Ceiling fan of any sweep complete all as per the existing specifications and as directed (Make :TATA/ SKF / NBC)
Supply only ball bearing suitable for exhaust fan of any sweep complete all as per the existing specifications and as directed (Make : TATA/SKF / NBC)
Supply only ball bearing suitable for air circulator/ pedestal fan/ wall mounting fan of any sweep complete all as per the existing specifications and as directed (Make : TATA/SKF / NBC)
Supply only shackle and clamps including rubber bush, bolts, nuts, washer and split, canopies etc suitable for ceiling fan of any sweep complete all as per the existing specifications and as directed
Supply only bolts, nuts with frame and washers etc suitable for exhaust fan of any sweep complete all as per the existing specifications and as directed
Supply only fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only fan capacitors of 4 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only brass bush suitable for ceiling fan of any sweep and capapcity complete all as per existing specification and as directed.
Supply only brass bush suitable for exhaust fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 12" (1.00 ft) long to bear the load of 1000 kg for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 24" (2.00 ft) long to bear the load of 1000 Kg for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
S & F in repairs of BLDC fan PCB board as suitable for existing BLDC fans including testing complete all as specified and directed. Make : PCB board shall be of same make provided by OEM
S & F in repairs of BLDC fan bearing suitable for existing BLDC ceiling fan of any sweep and capacity including testing complete all as per existing specification and as directed.
Supply only rust proof aluminium alloy powder coated blades set suitable for ceiling fan 1200 / 1400 mm sweep any make complete all as per existing specification and as directed.
Supply only metal blades set suitable for exhaust fan 225 to 450 mm sweep any make complete all as per existing specification and as directed.
Supply only plastic blades set suitable for bathroom exhaust fan upto 200mm sweep of any make complete all as per existing specification and as directed.
S & F in repairs steped type modular fan regulator ,100/120 W, 1/2 module complete all as specified and as directed.
S & F in repairs steped type fan regulator,flush type ,100/120 W, complete all as specified and as directed.
S & F in repairs stationary louvers suitable for exhaust fan of 300mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed. (Note: Louver has to fixed upto fifteen metre height multistoried building. The unit quoted rate shall deemed to be inclusive of necessary scafolding and safety measure for fixing of louver upto sixty metre height. No extra claim on this account shall be entertained later on)
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The ceiling fan taken down under Serial item No. 01 shall be painted and measured under this item.)
M & L for preparation of old painted surfaces of exhaust fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The exhaust fan taken down under Serial item No. 02 shall be painted and measured under this item.)
M & L for preparation of old painted surfaces of air circulator/ pedestal fan/ wall mounting fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The air circulator/ pedestal fan/ wall mounting fan taken down under Serial item No. 03 shall be painted and measured under this item.)
Taking down the ceiling fan of any size/sweep/make from existing position dismantling blades ,spare parts for cleaning,servicing,oiling and lubricating etc including preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker, refixing the blades and rehanging the fan in its original position,connecting up etc complete all as directed.
Taking down the exhaust fan of any size/sweep/make from existing position dismantling blades,spare parts for cleaning,servicing,oiling and lubricating etc including preparation of old painted surfaces of exhaust fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker, refixing the blades and rehanging the fan in its original position,connecting up etc complete all as directed.
Taking down the air circulator/ pedestal fan/ wall mounting fan of any size/sweep/make from existing position dismantling blades including preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker, refixing the blades and fan,connecting up complete all as directed.
Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor >0.94 Wattage and not more than 35 Watt, air delivery not less than 215cmm alongwith electronic type regulator and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan including taking down old unserviceable ceiling fan from its existing position and removing to MES store yard complete all as specified and directed. (Note: Ceiling fan should have minimum 5 years manufacturer's warranty) (Make : USHA/Havell's/Bajaj/CG)
S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F PVC body Exhaust fan, 200 mm sweep, AC, single phase complete with all accessories and electric connection including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
Taking down the existing storage type water heater of any capacity of any type and size by disconnecting electric connection, carring out following necessary repair work, tinkering and welding etc. including de-scaling, brushing and thoroughly cleaning the storage tank/inner water tank, removing of hard water deposits, and connected back and re-fixing in orignal position, grounting, testing and commissioning, complete with entire satisfection of Engr-in-Charge:- (a) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required. (b) Inspect over flow and vent pipes and remove blockages (if any) (c) Checking and rectify earth continuity of the electrical circuits of the geyser and power points (d) Check, maintain and re-fixing thermostat and re-adjust (e) Visual examination of of fusible plugs for its serviceability (f) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution (g) Checking of indicator lamp for its serviceability (Note: (i) Spare parts/components of geysers shall be measured and paid seperately as "supply only" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt. (iii) Painting of geyser shall be measured and paid seperately)
Supply only heating element, 2KW capapcity, AC 230 volts, including rubber gasket complete all as per the existing specifications and as directed.
Supply only fusible plug melting at 90 - 100 degrees Centigrade complete all as specified and as directed.
Supply only thermostat including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for 25 /35/ 50 ltrs capacity Geysers complete all as specified and as directed.
Supply only high pressure valve with dead weight suitable for 25/50 ltrs capacity Geysers complete all as specified and directed.
Supply only stainless steel braided flexible connecting pipe 18" long with brass adopters for hot water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers complete all as specified and directed.
Supply only PVC braided connection pipe 18" long with brass adopters for cold water supply complete all as specified and as directed
M & L for Repair to 25 Ltr water heater/Gyser cell cover by cutting rusted sheet and replacening with new MS sheet of 18 guage by brazing or welding as required to match existing cell cover including testing for a 3 kg /sqcm pressure, re-assembling and applying two coats of synthetic enamel paint (by spraying) over a coat of red oxide zinc chrome primer complete to whole geyser including preparation of old surfaces after complete removal of existing paint of vertical/horizontal type geysers by scraping with wire brush and emery paper including writing geyser Number etc including taking down and re-fixing in original position, testing and commissioning complete all as specified and as directed.
S & F In repairs, bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25/35/50 ltrs capacity Geysers including complete all as specified and as directed.
S & F In repairs, Base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket complete all as specified and as directed.
S & F In repairs, brass non return valve (check valve), 15mm bore with necessary GI specials complete all as specified and as directed.
S & F In repairs brass stop cock, 15mm bore with necessary GI specials complete all as specified and as directed.
Supply and fixing in repair stainless steel-304 made inner vessel of water storage heater including brazing,welding,testing for a pressure of 3 kg/sqcm including opening and re-assembling the geyser of 25 lit capacity complete all as specified and directed.
S & F in repairs indicator lamp, retangular/round shape, blue/green/red colour suitable for geyser 50/35/25 ltrs capacity complete all as specified and directed.
S & F in repairs PVC insulated copper conductor cable 3 crore of size 48/ 0.2 fixed to any capacity geysers as required length complete all as specified and directed
Labour only for rectification of leakages in connecting pipes and repair of minor complaints in geysers of any capacity without taking down the geyser from its existing position complete all as specified and directed.
S & F in repair SRCD protected socket with PVC base box including 20 Amps, MCB SP complete all as specified and as directed. (Make: Havell's Cat No. DHDDCDP025202003 or equivelant of make as per List of Manufacturer's)
S & F in repairs, AC Plug Top 20 Amps 240 volts, 3 pin complete all as specifed and as directed
S&F in repairs MCB 6-32 Amps single pole 240Volts 10 KA C Series fixed in repair, complete all as specified Make C&S/ havells/Standered/Legrand/ Indoasain
M&L for applying two coats of synthetic enamel paint (by spraying) over a coat of red oxide zinc chrome primer complete to whole geyser including preparation of old surfaces after complete removal of existing paint of vertical/horizontal type geysers 25/35/50 lit by scraping with wire brush and emery paper including writing geyser Number etc including taking down and re-fixing in original position, testing and commissioning complete all as specified and as directed.
S & F energy efficient, BEE 5 star rated storage type water heater of 25 ltr capacity with 2000W capacity heating element, confirming to IS 2082, with stainless steel inner tank and ABS outer shell complete fixed to wall with suitable expansion fasterners including 1/2 inch dia rigid fixed stainless steel hot and cold water connection and connecting to angle valve and 15 mm bore brass chromium coated non return valve complete all as specified and as directed. (Make: Crompton/Bajaj/Havells/Jaquar )
S & F in repair Single core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 1.5 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4.0 sqmm complete all as specified and as directed.
S&F ceiling fan safety wire set with 1.6 mm stranded wire along with 2 nos U clamp and one L camp complete all as specified and directed.
RAHITHI INFRA (BID ID -3175663)
SRIKRISHNACONSTRUCTIONS (BID ID -3172210)
KALPANA INFRA PROJECTS (BID ID -3175550)
M/s SAI GANESH ENGINEERING ENTERPRISES (BID ID -3175012)
jyothi constructions (BID ID -3175729)
JAHNAVI ASSOCIATES (BID ID -3176121)
NIKESH ENTERPRISES (BID ID -3181616)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .