Revised BOQ TASAR
REVISED BILL OF QUANTITIES (BOQ) including GST
SL.No DESCRIPTION AMOUNT In Rs.
1 CIVIL AND PHE WORK 183266844.42
2 EXTERNAL DEVELOPMENT 9425103.81
3 DRAIN AND UGR 12535078.55
4 BOUNDARY WALL 13192241.96
5 LIFT WORKS 2049037.67
6 ELECTRICAL 38422656.30
7 EQUIPMENT 28523548.26
8 FIRE MANAGEMENT SYSTEM 2071012.68
10 SIGNAGE 1245298.88
11 FURNITURE WORKS 5409600.00
TOTAL AMOUNT PUT TO TENDER 297682560.39
TOTAL AMOUNT PUT TO TENDER 297682560.39
BIBHU DUTTA Digitally signed by
BIBHU DUTTA MISHRA
MISHRA Date: 2021.04.29
CIVIL AND PHE WORKS
Sl. Item Description Unit Rate Quantities Amount
A.- Civil Works:-
1 Earth work excavation in hard soil or gravelly soil within 50m. Intial lead and 1.5 m.
intial lift including rough dressing and breaking clods to maximum 5cm. To 7cm and
laying and layers not exceeding 0.3m in depth and as per direction of the department.
2 Extra lift of 1.5m. or part there of over the initial depth of 1.5m. in all kinds of
embankments, road works and
ordinary earth works in general.
1st extra lift of 1.5m. (Up to 7.5m.) CUM 16.80 1380.96 23200.13
3 Extra lead of 25m. or part there of over the initial lead of 50m. for earth work in all
kinds of embankment, road works and ordinary earth work in general. (a) 50m. to
4 Filling in foundation and plinth with excavated materials including watering and
ramming as directed by the Engineer-in-charge. CUM 114.99 1599.17 183889.31
5 Supplying and filling sand in foundation and plinth including watering , ramming,
consolidating and dressing, labours, tools, taxes etc. all complete as per the
specification and direction of E.I.C. (Ground Floor)
6 Pre-Constructional Anti-Termite Treatment works :
6.1 Supplying, diluting and preparing chemical emulsion like CHLOROPYRIPHOS or other
chemicals as approved by central Insectcides Board or as directed by the manufacturer
and spraying the mixture uniformly by sprayer as pre-constructional anti-termite
treatment and creating a chemical barrior under and around wall trenches, basement
excavation, top surfaces of plinth filling,junctions of wall and floors along with external
perimeter of the building surrounding the pipes and conduits etc. complete at the rate
of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and @ 5.0 litre
per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in
trenches at 150mm centre to centre etc. complete as per IS 6313/1981(Part-II) and as
per the direction of the Engineer-in-charge including all cost of materials labour, taxes
etc all complete.
6.2 Supplying, laying 10micron Polythene membrane over compacted sand filling in plinth,
before laying plain cement concrete (1:4:8).
7 Plain Cement Concrete works :
7.1 Providing and Laying plain cement concrete 1: 4: 8 .( 1 cement : 4 sand : 8 stone
Aggregate 40mm nominal size ) As levelling course in foundation and plinth etc.
complete all depth and height. CUM 4738.72 763.28 3616970.20
7.2 2.5cm. damp proof course with C.C. (1:2:4) using 12mm. size crusher broken granite
8 Reinforced Cement Concrete works :
8.1 R.C.C. work of M-25 grade with 20mm & down grade size black hard granite (crusher
broken) chips including hoisting and laying.
In Ground Floor including Foundation :
8.2 R.C.C. work of M-25 grade with 20mm & down grade size black hard granite (crusher
broken) chips including hoisting and laying.
In First Floor : CUM 5856.48 796.74 4666062.59
Sl. Item Description Unit Rate Quantities Amount
8.3 R.C.C. work of M-25 grade with 20mm & down grade size black hard granite (crusher
broken) chips including hoisting and laying. In 2nd Floor Level :
9 Centering & Shuttering works :
(i) For centering and shuttering for R.C.C. work (in floor and roof slab, Landings,
Balconies, projecting sunshades, Chajja, Stairs Plinth band,footings , base of columns,
precast slab, beams and columns, Lintels,R.C.C. Walls and Fins) in first floor and
subsequent upper floors add 20 percent extra to the rate of respective centering and
shuttering items over and above the rates from the next lower floor.
9.1 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in ground floor.:
(i) R.C.C. Floor roof slabs, landings, balconies, projecting sun-shades and chajjas upto
9.2 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in First floor.:
(i) R.C.C. Floor roof slabs, landings, balconies, projecting sun-shades and chajjas upto
9.3 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in Second floor.:
(i) R.C.C. Floor roof slabs, landings, balconies, projecting sun-shades and chajjas upto
9.4 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in ground floor.:
R.C.C. stairs excluding landing but including railing
9.5 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in First floor.:
R.C.C. stairs excluding landing but including railing
9.6 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in ground floor.:
R.C.C. foundation and plinth band, footings, bases of columns, mass concrete, precast
9.7 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in ground floor.:
R.C.C. beams, columns, girders and bressmers etc.
9.8 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in First floor.:
R.C.C. beams, columns, girders and bressmers etc.
9.9 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in Second floor.:
R.C.C. beams, columns, girders and bressmers etc.
Sl. Item Description Unit Rate Quantities Amount
9.10 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in ground floor.:
9.11 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in First floor.:
9.12 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in Second floor.:
9.13 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in Ground floor.:
R.C.C. walls and fins including attached pilastes
9.14 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in First floor.:
R.C.C. walls and fins including attached pilastes
9.15 Rigid and smooth centering and shuttering for R.C.C. works including false work and
dismantling them after casting including cost of materials complete in Second floor.:
R.C.C. walls and fins including attached pilastes
10 Reinforcement works :
10.1 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete with Thermo-Mechanically Treated bars of grade Fe-
In Ground Floor QTL 9065.34 3169.00 28728048.11
10.2 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete with Thermo-Mechanically Treated bars of grade Fe-
In First Floor QTL 9088.19 1121.15 10189195.78
10.3 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete with Thermo-Mechanically Treated bars of grade Fe-
In Second Floor QTL 9111.15 522.68 4762213.64
11 MASONRY BRICK WORK WITH 25CM. BRICKS :
11.1 Brick work with Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength
not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in
foundation and plinth. CUM 4873.12 570.94 2782247.88
11.2 Brick work with Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength
not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in Cement mortar 1:6 (1
cement : 6 coarse sand) in Super structure In Ground Floor above Plinth level :.
11.3 Brick work with Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength
not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in Cement mortar 1:6 (1
cement : 6 coarse sand) : in 1st Floor :.
11.4 Brick work with Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength
not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in Cement mortar 1:6 (1
cement : 6 coarse sand) in 2nd Floor :.
Sl. Item Description Unit Rate Quantities Amount
11.5 Half brick masonry with non modular fly ash bricks of class designation 10,
conformingio IS :12894, in super structure above plinth and upto floor V level.: In
Cement mortar 1 : 4 (1 cement : 4 coarse sand) SQM 712.32 3914.88 2788644.47
11.6 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry. SQM 1067.36 3914.88 4178582.05
12 Wood & PVC works :
12.1 Dressed seasoned sal wood work framed and fixed (Wrought and put up) in trusses
purlins frames of doors, windows ventilators and beams
12.2 Providing and fixing factory made uPVC door frame made of uPVC extruded sections
having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (±
0.2 mm), corners of the door frame to be Jointed with galvanized brackets and
stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the
frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm)
wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per
manufacturer’s specification and direction of Engineerin-charge.
Extruded section profile size 42x50 mm
12.3 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board construction with frame of 1st class hard wood
and well matched commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
12.4 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded
PVC section of the size of 762 mm X25 mm or less as per requirement with an average
wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided
on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having
dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of
the door. Core of the door shutter should be filled with High Density Polyurethane
foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size
25 mm X 11 mm. Door shutter shall be reinforced with special polymeric
reinforcements as per manufacturer’s specification and direction of Engineer-in-charge
to take up necessary hardware and fixtures. Stickers indicating the locations of
hardware will be pasted at appropriate places
12.5 Stair case Railing :
Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel , MS Tubes as hand rail, etc. as required as per drawings..,
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13 ALUMINIUM WORKS :
Sl. Item Description Unit Rate Quantities Amount
13.1 Supplying, fitting, fixing up window (sliding type)made up aluminum Section 151-154,
151-155, aswindows frame section No. 151-155, 151-153 and 151-167 as shutter frame
with 5mm thick blackglass as panel fitted with rubber bending including locking
arrangement including all fitting including cost of materials all taxes labour, T&P etc.
complete as per direction of Engineer-in-charge.
13.2 Providing fitting, fixing of Al. door with 60 micron powder coated Al. door section of
9202 as vertical member, 9201 as top member and 9200 as bottom and middle
member and 6mm plain glass in top portion with 12mm thick pre-laminated board in
bottom portion fixed on door frame by means of tapered clip No. 4660 and the frame
to be completed by means of jointing angle No. 1855 including all cost of labour, T&P,
hire charges of drilling machine, labour charges etc. complete
13.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash
fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions,
i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap beading for
glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash
fasteners to be paid for separately) :For fixed portion:
Powder coated aluminium (minimum thickness of powder coating 60 micron)
13.4 Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of engineer-in-charge .
(Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
13.5 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat with approved steel primer all
Fixed to openings /wooden frames with rawl plugs screws etc. Kgs 127.68 12357.76 1577838.67
13.6 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron
and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings
complete, including applying a priming coat of approved steel primer.
Using flats 30x6mm for diagonal braces and central cross piece.
14 DOOR - WINDOW FITTINGS :
14.1 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6
levers and a pair of lever handles of approved quality with necessary screws etc.
14.2 Providing and fixing chromium plated brass handles with necessary screws etc.
Sl. Item Description Unit Rate Quantities Amount
14.3 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating
not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or
shade, with nuts and screws etc. complete : 300x16 mm.
14.4 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or
shade, with necessary screws etc. complete : 300x10 mm each
14.5 Providing and fixing bright finished brass hanging type floor door stopper with
necessary screws, etc. complete. EACH 104.16 54.00 5624.64
14.6 Providing and fixing aluminium die cast body tubular type universal hydraulic door
closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto
35 kg and door width upto 700 mm), with necessary accessories and screws etc.
14.7 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of
handles (best make of approved quality) for aluminium windows including necessary
cutting and making good the windows etc. complete as per architectural drawing &
direction of Engineer-in-charge.
15 FLOORING WORKS :
15.1 Kota Stone Flooring
15.1.1 Kota Stone Flooring in Stair risers & skirtings :
Fixing Kota Tiles of minimum 16 mm thick , in dado, skirting and rises of steps on
12mm. thick cement plaster 1:3 (1 cement : 3 sand) joined with neat cement slurry
mixed with pigment to match the shade of the tiles including rubbing and polishing
complete including cost of precast tile. . - In Ground Floor.
15.1.2 Kota Stone Flooring in Stair risers & skirtings :
Fixing Kota Tiles of minimum 16 mm thick , in dado, skirting and rises of steps on
12mm. thick cement plaster 1:3 (1 cement : 3 sand) joined with neat cement slurry
mixed with pigment to match the shade of the tiles including rubbing and polishing
complete including cost of precast tile. . - In First Floor.
15.1.3 Kota Stone Flooring in Floor, Stair Landing & Treads :
Fixing Kota Tiles of minimum 16 mm thick in floors, treads on steps and landing on
25mm. thick bed of cement mortar 1:1 (1 cement : 1 sand) joined with neat cement
slurry mixed with pigment to match the shade of the tiles including rubbing and
polishing complete including cost of precast tile.)- In Ground Floor
15.1.4 Kota Stone Flooring in Floor, Stair Landing & Treads:
Fixing Kota Tiles of minimum 16 mm thick in floors, treads on steps and landing on
25mm. thick bed of cement mortar 1:1 (1 cement : 1 sand) joined with neat cement
slurry mixed with pigment to match the shade of the tiles including rubbing and
polishing complete including cost of precast tile.)- In First Floor
15.2 Anti skid Ceramic Tiles Flooring :
15.2.1 Fixing 30cm x 30cm / 40cm x 40cm special plain / printed series ceramic floor tiles of
premium grade having thickness 7mm to 8mm confirming to IS 13755 in floors,
treads on steps and landing on 25mm. thick bed of cement mortar 1:1 (1 cement : 1
sand) joined with neat cement slurry mixed with pigment to match the shade of the
tiles including rubbing and polishing complete including cost of precast tile.)- In
Ground Floor SQM 1111.04 550.85 612017.05
Sl. Item Description Unit Rate Quantities Amount
15.2.2 Fixing 30cm x 30cm / 40cm x 40cm special plain / printed series ceramic floor tiles of
premium grade having thickness 7mm to 8mm confirming to IS 13755 in floors,
treads on steps and landing on 25mm. thick bed of cement mortar 1:1 (1 cement : 1
sand) joined with neat cement slurry mixed with pigment to match the shade of the
tiles including rubbing and polishing complete including cost of precast tile.)- In First
15.3 Chequered Tiles Flooring:
15.3.1 Fixing Chequerred precast cement concrete tiles 22 mm thick in floors, treads on steps
and landing on 25mm. thick bed of cement mortar 1:1 (1 cement : 1 sand) joined with
neat cement slurry mixed with pigment to match the shade of the tiles including
rubbing and polishing complete including cost of precast tile.)- In Ground Floor
15.3.2 62mm thick Hardenite Flooring :
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50
mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2
(1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume,
hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s
specifications. This includes cost of cement slurry, but excluding the cost of nosing of
steps etc. complete.
15.3.3 CC(1:2:4) Flooring Finished with floating coat of neat cement punning.:
2.5 Cm. artificial stone flooring with cement concrete (1:2:4) with washed gravel
including punning. SQM 309.12 379.32 117255.40
15.4 Terrazo / Mosaic Flooring :
40 mm thick marble chips flooring rubbed and polished to granolithic finish, under
layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 12.5 mm nominal size) and top layer 6mm thick with white, black, chocolate,
grey, yellow or green marble chips of sizes from 1 mm to 4 mm nominal size, laid in
cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion
of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, including cement
slurry etc. complete :
Medium shade pigment with 50% white cement and 50% ordinary cement
15.5 Wall Ceramic Tiles :
15.5.1 Fixing 20cmx30cm / 20cm x 20cm special plain /printed series ceramic wall tiles of
premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 , in dado,
skirting and rises of steps on 12mm. thick cement plaster 1:3 (1 cement : 3 sand) joined
with neat cement slurry mixed with pigment to match the shade of the tiles including
rubbing and polishing complete including cost of precast tile. . - In Ground Floor.
15.5.2 Fixing 20cmx30cm / 20cm x 20cm special plain /printed series ceramic wall tiles of
premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 , in dado,
skirting and rises of steps on 12mm. thick cement plaster 1:3 (1 cement : 3 sand) joined
with neat cement slurry mixed with pigment to match the shade of the tiles including
rubbing and polishing complete including cost of precast tile. . - In First Floor.
16 INTERNAL FINISHING WORKS :
16.1 6MM CEMENT PLASTER TO CEILING :
Sl. Item Description Unit Rate Quantities Amount
16.1.1 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep
chiping and slury treatment - In Ground Floor SQM 168.98 4681.24 791018.00
16.1.2 6mm thick cement plaster (1:4) to R.C.C. surfacesfinished smooth including closed
deep chipping & slurry treatment. - In First Floor SQM 173.15 3360.89 581945.52
16.1.3 6mm thick cement plaster (1:4) to R.C.C. surfacesfinished smooth including closed
deep chipping & slurry treatment. - In Second Floor SQM 177.52 123.03 21839.40
16.2 12MM CEMENT PLASTER TO INSIDE FACES OF WALLS :
16.2.1 12mm thick Cement Plaster (1:4) over Brick Masonry finished smooth in Inside - In
16.2.2 12mm thick Cement Plaster (1:4) over Brick Masonry finished smooth in Inside - In First
16.2.3 12mm thick Cement Plaster (1:4) over Brick Masonry finished smooth in Inside - In
Second Floor. SQM 171.14 421.54 72140.67
16.3 Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete. SQM 80.64 29745.69 2398692.10
16.4 Applying priming coats with primer of approved brand and manufacture, having low
VOC (Volatile Organic Compound ) content..:
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC
content less than 50 grams/ litre. SQM 41.44 1499.92 62156.56
16.5 Applying priming coats with primer of approved brand and manufacture, having low
VOC (Volatile Organic Compound ) content..:
With water thinnable cement primer on wall surface having VOC content less than 50
16.6 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less
than 50 gms/litre, of approved manufacturer, of required shade and colour complete,
as per manufacturer’s specification.
Two or more coats on new work sqm
16.7 Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and
manufacture, including applying additional coats wherever required to achieve even
shade and colour.
16.8 Painting with synthetic enamel paint having VOC (Volatile Organic Compound )
content less than 50 grams/ litre of approved brand and manufacture to give an even
shade : Two or more coats on new work sqm 82.88 665.00 55115.20
17 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias
and similar locations of required size, approved shade, colour and texture laid over 20
mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade Area of slab over 0.50 sqm .
18 Extra for fixing marble /granite stone, over and above corresponding basic item, in
facia and drops of width upto 150 mm with epoxy resin based adhesive, including
cleaning etc. complete. RMT 282.24 306.03 86373.91
19 Extra for providing opening of required size & shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar location in marble/ Granite/ stone work,
including necessary holes for pillar taps etc. including moulding, rubbing and polishing
of cut edges etc. complete.
Sl. Item Description Unit Rate Quantities Amount
20 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size
75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of
appropriate width with chase cutter and embedding the stone in the chase with epoxy
grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished
smooth. Granite Stone of approved shade.
21 EXTERNAL FINISHING WORKS ":
21.1 20 MM THICK CEMENT PLASTER TO OUTSIDE FACES OF WALLs
[To prevent surface cracks appearing between junctions of column/beam and walls,
150 mm wide chicken wire mesh should be fixed with U nails 150 mm centre to centre
before plastering the junction. The plastering of walls and beam/column in one vertical
plane should be carried out in one go. For providing and fixing chicken wire mesh with
U nails payment shall be made separately.]
21.1.1 Providing & Applying .20mm thick cement plaster (1:4) (1 cement: 4 coarse sand). - In
Ground Floor. SQM 238.56 3590.34 856511.51
21.1.2 Providing & Applying .20mm thick cement plaster (1:4) (1 cement: 4 coarse sand). - In
21.1.3 Providing & Applying .20mm thick cement plaster (1:4) (1 cement: 4 coarse sand). - In
Second Floor. SQM 256.48 360.61 92489.77
21.2 Supplying 150 mm wide chicken wire mesh of standard quality as available in local
market & fixing with U- nails 150 mm centre to centre before plastering the junction
of walls and beam/column in one vertical plane to prevent surface cracks appearing
between junctions of column/beam and walls before plastering. Payment shall be
made by measuring the chicken mesh area only.
21.3 Finishing walls with water proofing cement paint of approved shade on new work two
coats to give an even shade including the cost of cement paint. - In Ground Floor level.
21.4 Finishing walls with water proofing cement paint of approved shade on new work two
coats to give an even shade including the cost of cement paint. - At First Floor level.
21.5 Finishing walls with water proofing cement paint of approved shade on new work two
coats to give an even shade including the cost of cement paint. - At above First Floor
21.6 Finishing walls with exterior weather coat / weather shield paint of required shade :
Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm.
22 Drip course mould plaster 1:4 (1:cement :4 sand) including necessary scaffolding curing
etc complete at all depth and height as per direction of site in charge.
23 "2.5 cm thick grading concrete (1:2:4) on roof slab with 6mm size hard granite chips on
new work including cost of labour,material,T&P etc all complete. "
24 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse
sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed
of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted
with fine sand, including necessary excavation, levelling & dressing & finishing the top
Sl. Item Description Unit Rate Quantities Amount
25 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone
aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1
cement : 3 fine sand) as per standard design : In 75x75 mm deep chase metre
26 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over
P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement
: 3 coarse sand) and a coat of neat cement, rounding the edges and making and
finishing the outlet complete.
27 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10
mm gap for thermal expansion,
(i) Single socketed pipes.: 110 mm diameter RMT. 430.08 840.00 361267.20
28 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal
28.2 Shoe (Plain)
28.3 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised -
PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S.
screws of required length, including cutting brick work and fixing in cement mortar 1:4
(1 cement : 4 coarse sand) and making good the wall etc. complete.: 110 mm
29 False Ceiling works :
15mm thick calcium silicate false ceiling
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight
calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true
horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel
sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’
runner suitably spaced at joints to get required length and of size 24x38 mm made
from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T”
of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced
between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and
secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick
(Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid
of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle
pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with
the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @
230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of
approved texture in the grid, including, cutting/ making opening for services like
diffusers, grills, light fittings, fixtures, smoke detectors etc.,
Sl. Item Description Unit Rate Quantities Amount
wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted
cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash
fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x
0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24
mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as
per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/ opening (cut outs) having area less than
0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light
reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance
and also having thermal conductivity <0.043 w/ mK.
30 Structural steel work riveted, bolted or welded in built up sections, trusses and framed
work, including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer all complete.
31 Design, supply, installation complete in all respect of prefabricated tunnel green
houses 42 m x 8 m (336 sqm) growing area and height 2.5 m as per parameters below:
Ridge: 1 x H profile belt / 34 x 32 x 1.5 mm
Laterals: 2 x H profile belts / 34 x 32 x 1.5 mm
Front & auctions: C proflie for zig zag
Enclosure door: 1 front door 2x3 , 2 retractable doors
Front closing: plastic as per manufacturer's specification
Front reinforcement: Galvanizzed square tube/ Sendzimir 275 or equivalent / 50 mm
Arcs: ⌀ 48 x 1.5 mm / distance 2.8 m
Laterals: Anti insect mesh 20 x 10 threads per sqcm/perimeter skirt Raffia cloth
Pillars: Galvanized steel Sendzimir 275 or eqv./ 48 x 1.5 mm
Plastic cover shall be as per manufacturer's specification Necessary construction
drawings and design from manufacturer based on above parameters to be submitted
to EIC for approval. Above cost is inclusive of all materials/ accessories required for
installation. Manufacturer's certification regarding material, design, installation and
quality assurance has to be submitted.
32 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any
pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I
plain/bitumen washers complete
but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured
out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin
system under approximately 2400 psi and hot cured. They shall be of uniform
pigmentation and thickness without air pockets and shall conform to IS 10192 and IS
12866.The sheets shall be opaque or translucent, clear or pigmented, textured or
smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down
(2" or 3" or 6" ) as specified .
Sl. Item Description Unit Rate Quantities Amount
33 Supplying and fixing rolling shutters of approved make, made of required size M.S.
laths, interlocked together through their entire length and jointed together at the end
by end locks, mounted on specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull operation complete,
including the cost of providing and fixing necessary 27.5 cm long wire springs
manufactured from high tensile steel wire of adequate strength conforming to IS: 4454
- part 1 and M.S. top cover of required thickness for rolling shutters.: 80x1.25 mm M.S.
laths with 1.25 mm thick top cover .
34 Concrete Pavers Block
Providing and laying 60mm thick faciory made cement concrete interlocking paver
block of M -30 grade made by block making machine with strong vibratory compaction,
of approved size, design & shape, laid in required colour and pattern over and
including 50mm thick compacted bed of coarse sand, filling the joints with line sand
etc. all complete as per the direction of Engineer-in-charge.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer, including welding and bolted with special shaped
washers etc. complete.
Hot finished seamless type tubes
36 Providing and fixing precoated galvanised iron profile sheets (size, shape
and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05
%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277,
in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet should have protective guard film of 25
microns minimum to avoid scratches during transportation and should be
supplied in single length upto 12 metre or as desired by Engineerin-charge. The
sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)
with EPDM seal, complete upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters and trusses and including cutting
to size and shape wherever required.
37 Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining wall of the
basement, water tanks, roof slabs, podiums, reservoir, sewage& water
treatment plant, tunnels/subway and bridge deck etc. prepared by mixing in the
ratio of 5:2(5 parts integral crystalline slurry :2 parts water ) for vertical surfaces
& 3:1 (3 parts integral crystalline slurry:1 part water) for horizontal surface and
applying the same from negative (internal) side with the help of synthetic fiber
brush Penetron slurry [email protected] kg/Sqmt. for two coat . The material shall
meet the requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as
per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The
crystalline slurry shall be capable of self-healing of cracks upto a width of
0.50mm. The work shall be carried out all complete as per specification and the
direction of the engineer-in-charge. The product performance shall carry
guarantee for 10 years against any leakage.
For all surface.
Sl. Item Description Unit Rate Quantities Amount
38 Providing and fixing Glass Reinforced Concrete (G.R.C) Screens/Jali in approved size,
pattern, design, thickness and color including MS framing duly painted with corrosion
resitant paint / rust proof paint complete with sealant and complete with all necessary
accessories. Necessary fabrication drawings including fixing details of Jali to be
submitted for approval prior to execution.
Border Thickness: min. 50mm : Internal Membrane: min. 30mm
39 Providing and applying pattern painting, replicating Indian traditional embroidery art,
with texture paints composed of high-quality durable acrylic modified resin, UV
resistant and designed with anti-algal and anti-fungal properties, of approved
manufacturer, over a coat of suitable under coat primer, to the external walls upto
floor-V level as per approved design/Drawing .
40 POINTING ON BRICK WORK :
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine
sand): Flush / Ruled/ Struck or weathered pointing SQM 184.80 3221.78 595384.02
TOTAL OF CIVIL WORKS : Rs 175583933.28
B. INTERNAL P.H Work:-
1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to
IS:15778,having thermal stability for hot & cold water supply, including all CPVC plain
& brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step CPVC solvent cement and testing of
joints complete as per direction of Engineer-in-Charge. Concealed work, including
cutting chases and making good the walls etc
1.1 a) 32 mm nominal outer dia Pipes Mtr 1442.54 1062.00 1531974.93
2 Cutting holes through existing brick work including making good the same in cement
mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification.
3 Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the
damages as per specification complete.
3.1 a) Detail cost per 1 meter Mtr 81.76 2092.00 171041.92
4 Providing and fixing on wall face unplasticised Rigid PVC soil,waste and rain water
pipes confirming to IS:13592 Type A(single socket pipes) & on wall face unplasticised-
PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal expansion .
4.1 110 mm dia SWR pipes (UPVC) MTR 685.44 653.00 447592.32
4.2 110 mm dia single junction with door NOS 598.61 102.00 61058.71
4.4 110 mm dia bend with door NOS 341.58 102.00 34840.92
5 Fixing 110mm size ‘P’ or ‘S’ trap (UPVC fittings conforming to IS 14735:1999) for water
closet squatting pan including jointing the trap with pan as per specification of the
manufacturer of fittings.
6 110mm dia floor trap (IN-LET OUT-LET Type) NOS 191.46 87.00 16657.32
Sl. Item Description Unit Rate Quantities Amount
8 Supply & Fixing water closet,squatting pan (Orrisa type W.C pan) conforming to IS
2556:part3-2004;( With PVC Low down Cistern of approved make) duly embedded in
cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per
(White Glazed vitreous china Squatting Pan-Long pattern size 580mm.) NOS 5684.51 19.00 108005.68
9 Supply & Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or
‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and
chromium plated screws including jointing the trap with soil pipe in cement mortar
(1:1) etc all complete as per specification. ( With PVC Seat & cover and PVC Low down
Cistern of approved make) (White Vitreous china wash down water closet E.W.C)
10 Supply & Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-
2004, of approved make, with Cast Iron or M S brackets painted white including
cutting holes in walls and making good the damages etc all complete as per
a)Vitreous china flat back wash basin 550mmX400mm NOS 2873.19 68.00 195377.06
11 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350
mm of approved make with spreaders with unions and clamps (all in C.P. brass) with
waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.
brass, including painting of fittings and cutting and making good the walls and floors
wherever required :
12 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983, of
approved make. with C.I. brackets and stainless steel plug 40 mm, including painting of
fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink with drain board, 510x1040 mm bowl depth 250 mm
13 Providing and fixing P.V.C. low level flushing cistern with manually controlled device
(handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (10 Litre
14 Providing and fixing gun metal gate valve with C.I. wheel of ISI approved quality
(screwed end) :
15 Supply & Fixing of Brass Screw-down Bib Cocks (Taps) with flange , polished bright
conforming to IS:781-1995, of approved make of the following nominal sizes as per
specification complete. (Delux Head& high quality.
15.1 a)15mm dia CP brass bib cock (Short body ) with flange NOS 1263.83 73.00 92259.62
15.2 b)15mm dia CP brass bib cock (Long body ) with flange NOS 1383.39 15.00 20750.86
16 Supply & Fixing of Brass Screw-down Stop Cocks conforming to IS:781-1995 of the
following nominal sizes as per specification complete. (Deluxe Head& high quality)
16.1 a)15mm dia CP brass Angle Stop cock NOS 939.33 69.00 64813.96
16.2 b)15mm dia CP brass concealed Stop cock NOS 1178.45 124.00 146128.15
17 Supply & Fitting & fixing of following bathroom fixtures including all cost ,material
17.1 a) Supply & Fix Chromium Plated Brass Revolting Shower rose with Arm of 15mm or
20mm inlet including polishing all complete as per specification.(Deluxe Head &Heavy
17.2 b)Supplying, Fitting & fixing health faucet of approved make with one metre long
Tube, Hook & all fixtures. NOS 2339.80 61.00 142728.00
Sl. Item Description Unit Rate Quantities Amount
17.3 c)Supply & fixing Fixing Chromium Plated brass soap dish complete with Chromium
Plated brass brackets fixed to P.V.C plugs with Chromium Plated brass screws as per
specification. (125mm ). NOS 777.08 66.00 51287.54
17.4 d)Supplying & Fixing standard sized glass-shelf with Chromium Plated brass brackets
and guard rails complete, fixed to woden plugs with Chromium Plated brass screws &
Fixing of standard chromium plated shelf with all fixtures as per specification.
i) Glass shelf with C.P brass brackets and guard rails fixed to wooden plugs of size
600mm × 120mm with all fixtures .
17.5 e)Supply & Fixing standard sized Chromium Plated brass towel rail & towel ring
complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium
Plated brass screws, complete as per specification.
17.5.1 i)25mmX600mm long C.P towel rail (Heavy Quality) of approved make NOS 2387.63 31.00 74016.44
17.5.2 ii)C.P. towel ring (Heavy Quality) of approved make NOS 1050.34 31.00 32560.59
17.6 f)Supplying & Fixing 600mm x 450mm x 6mm thick mirror of superior glass with frame
of approved make and fixed to wall with wooden plugs & chromium plated brass
screws and washers complete as per manufacturer specification. (Heavy Quality)
18 Supplying & Laying in trenches unplasticised UPVC pipes conforming to IS:13592-2013
and specials of the following outside diameter for all classes including jointing with
supply of approved solvent cement by non-heat application method including testing
as per specification complete. (Earth work in trenches to be measured and paid for
18.1 a)160mm dia rigid UPVC pipe class-3 (0.60mpa) MTR 1589.67 276.00 438748.98
19 Construction of inspection chamber
Constructing brick masonry manhole in cement mortar 1:6 ( 1 cement : 6 coarse sand )
with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded
stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm
thick with cement mortar 1:4 (1 cement : 4 coarse sand) finished with floating coat of
neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement complete as per standard design :
Inside size 90x90 cm and 45 cm deep including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight of cover and frame to be not less than
38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less
than 75 Kg./Cm2
20 Supplying & Fixing rotational moulded polythylene cylindrical vertical water storage
tanks confirming to IS:12701-1996 including cutting holes through the tanks and fixing
mild steel tubes and fittings and providing extra sockets and jam nuts,fixing ball valv
etc,including hoisting up to ageight of 5m above ground level and placing the tank to
the required position etc all complete as per specification and direction of E.I.C
Sl. Item Description Unit Rate Quantities Amount
20.1 2000 ltr capacity double layer cylindrical vertical water storage tanks details of cost for
one tank on the roof of ground floor) NOS 13044.96 31.00 404393.91
21 Supplying, Testing, Commissioning,Fitting of Horizontal type centrifugal Pump with
electrically operated 1.0 HP motor for drawing water from underground water
reservoir to overhead Tanks installed over the Roof.
Total of Internal PHE 7682911.14
TOTAL of CIVIL AND PHE = 183266844.42
EXTERNAL DEVELOPMENT WORKS , i.e.,
(A) EXTERNAL PLUMBING WORKS, (B) HORTICULTURAL WORKS, (C) RAIN WATER HARVESTING & BORE WELL
WORKS, (D) DISMANTLING OF EXISTING STRUCTURES., (E ) INTERNAL BITUMINIOUS ROAD. etc.
Item Breif Description of works Unit Qty Rate Amount
A EXTERNAL PLUMBING WORKS
1.0 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA)
conforming to IS - 1536 :
2.0 Providing lead caulked joints to spun iron or C.I. pipes and specials,
including testing of joints but excluding the cost of pig lead : 100 mm
diameter pipe. Each 99.00 224.00 22176.00
3.0 Supplying pig lead at site of work. quintal 2.00 29034.10 58068.19
4.0 Excavating trenches of required width for pipes, cables, etc, including
excavation for sockets, depth upto 1.5 m, including getting out the
excavated materials, returning the soil as required in layers not exceeding
20 cm in depth, including consolidating each deposited layers by ramming,
watering etc.stacking serviceable material for measurements and disposal of
unserviceable material as directed, within a lead of 50 m :
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
5.0 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts,
rubber insertions etc. (the tail pieces if required will be paid separately) :
6.0 Constructing masonry Chamber 120x120x100 cm inside, in brick work in
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.
surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm
deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c
necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand :
10 graded stone aggregate 40 mm nominal size) and inside plastering with
cement mortar 1:3 (1 cement
: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :With common burnt clay F.P.S.(non
modular) bricks of class designation 7.5 each Each 4.00 28052.39 112209.57
7.0 Constructing masonry Chamber 90x90x100 cm inside, in brick work in
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I.
surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm
deep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c
necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand :
10 graded stone aggregate 40 mm nominal size ) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
8.0 Providing and laying S&S C.I. standard specials such as tees, bends,
collars, tapers, caps, tail piece etc. (Heavy class): Up to 300 mm dia Quintal 25.00 9244.48 231112.00
Total for EXTERNAL PLUMBING WORKS (A) 1512778.08
B HORTICULTURAL WORKS
Item Breif Description of works Unit Qty Rate Amount
1 Trenching in ordinary soil up to a depth of 60 cm including removal and
stacking of serviceable materials and then disposing of surplus soil, by
spreading and neatly levelling within a lead of 50 m and making up the
trenched area to proper levels by filling with earth or earth mixed with
sludge or / and manure before and after flooding trench with water
(excluding cost of imported earth, sludge or manure).
2 Supplying and stacking of good earth at site including royalty and carriage
upto 5 km lead complete (earth measured in stacks will be reduced by 20%
3 Supplying and stacking sludge at site including royalty and carriage upto 5
km lead complete (sludge measured in stacks will be reduced by 8% for
4 Supplying and stacking at site dump manure from approved source,
including carriage upto 5 km lead complete (manure measured in stacks
will be reduced by 8% for payment) :
4.1 Screened through sieve of I.S. designation 20 mm Cum 50.00 257.60 12880.00
4.2 Screened through sieve of I.S. designation 16 mm Cum 50.00 296.80 14840.00
4.3 Screened through sieve of I.S. designation 4.75 mm Cum 50.00 324.80 16240.00
5 Rough dressing the trenched ground including breaking clods. Sqm 500.00 1.68 840.00
6 Uprooting weeds from the trenched area after 10 to 15 days of its flooding
with water including disposal of uprooted vegetation. Sqm 500.00 5.04 2520.00
7 Fine dressing of the ground. Sqm 500.00 3.92 1960.00
8 Spreading of sludge, dump manure and/or good earth in required
thickness as per direction of officer-in-charge (cost of sludge, dump
manure and/ or good earth to be paid separately). Cum 300.00 52.08 15624.00
9 Mixing earth and sludge or manure in the required roportion specified or
directed by the Officer-in-charge Cum 300.00 36.40 10920.00
10 Grassing with selection No. 1/ Doob grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn, free from weeds and fit for mowing including supplying good earth,
if needed (the grass and good earth shall be paid for separately).
10.1 In rows 5 cm apart in both directions. Sqm 1000.00 17.92 17920.00
10.2 With grass Turf . Sqm 1000.00 13.44 13440.00
11 Renovating lawns including weeding, cheeling the grass, forking the
ground, top dressing with sludge or manure, mixing the same with forked
soil, watering and maintaining the lawn for 30 days or more till the grass
forms a thick lawn free from weeds and fit for mowing and disposal of
rubbish as directed, including supplying good earth if needed but excluding
the cost of sludge or manure (the good earth shall be paid for separately).
Item Breif Description of works Unit Qty Rate Amount
12 Half brick circular tree guard in bricks, internal diameter 1.25 metre and
height 1.2 metre above ground and 0.20 m below ground, bottom two
courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6
fine sand) and the intermediate courses being in dry honey comb masonry
per design complete:
With common burnt clay F.P.S. (non modular) bricks of class designation
12.1 Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high,
above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3
mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron
rings in two halves, fixing together at site with required six numbers of 8
mm dia and 30 mm long bolts, including painting two coats with synthetic
enamel paint of approved brand and manufacture over a coat of primer.
One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be
welded to the tree guard near the middle height and lettered CPWD /
approved name. The tree guard shall be suitably fixed to the ground by
embedding four legs of tree guard in pits of suitable dia and to a depth of
25 cm, refilling the pits with soil and ramming, complete in all respect as
per satisfaction and direction of Officer-in-charge. Each 50.00 4592.00 229600.00
13 Making tree guard 53 cm dia and 1.3 m high as per design from empty coal
tar drums, supplied free by the department, including providing and fixing
2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all
respects including painting inside and outside of tree guard with:
Two or more coats of synthetic enamel paint of approved quality shade
over a priming coat.
14 Edging with bricks laid dry length wise, including required excavation,
refilling, consolidating with hand packing and spreading surplus earth
neatly within a lead of 50 m :
With Common burnt clay F.P.S (non modular) bricks of Class
designation 7.5 . Metre 1000.00 56.00 56000.00
15 Providing Circular Cement Concrete pots of specified size, cast with
cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded
stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos
horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per
design, including required form work, finishing with cement punning on
exposed surface, curing for specified period and stacking in required rows
& height, all complete as per direction of Officer-in-charge.
15.1 Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall
thickness of 25.4 mm Each 200.00 246.40 49280.00
15.2 Top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cm with wall
thickness of 25.4 mm Each 200.00 179.20 35840.00
16 Supplying laying 60mm Pavers Blocks including the cost of sand packing &
PCC(1:4:8) below sand filling, in Pathways. Sqm 500.00 952.00 476000.00
Total for HORTICULTURAL WORKS (B) 1369984.00
Item Breif Description of works Unit Qty Rate Amount
C Sinking of Bore well :
Transportation to site of tube well/ Bore well, all boring
equipments,machinaries, tools etc with all accessories, including erection of
1.0 equipments for drilling of bore well, lowering of casing pipes and dismantling
/ removal charges of all equipments and transporting back from the site to
the place of delivery after completion of work. Job 2.00 6272.00 12544.00
Labour charges for drilling / boring of upto 400mm diameter with reverse-
circulation method by means of mechanically driven rotary-drilling system
through any type of soil for sinking / lowering the tube well with 200mm dia
PVC pipe for top enlargement ( up to 40.0metre depth). The quoted rate
should include the hire charges and labour for supplying & lowering of
2.0 suitable diameter casing pipes upto full depth of tubewell, drill-bits, drill pipes
and lowering of tube well assembly including necessary sockets,tools &
plants,staging and making necessary arrangement for boring ,force pumping
set and making arrangement for water required for boring etc, withdrawing
of casing pipes / drill bits etc complete and lowering of pipes, strainers, blank
pipe etc. complete.
2.1 a) From Ground level to 50 mtrs below Ground level.. Mtr 100.00 1756.16 175616.00
2.2 b) From 50 mtrs below GL to 100 mtrs below GL.. Mtr 100.00 1930.45 193045.44
2.3 c) From 100 mtrs below GL to 180 mtrs below GL.. Mtr 160.00 2268.58 362973.18
Providing & laying in position heavy duty PVC water pipe of approved make
conforming ti IS 13592 of SWR quality upto 10kg/sqcm pressure rated, for
permanant casing pipes of bore well to be laid upto 135 meters including all
fittings & fixtures and laid in proper line,level & alignment below ground level.
Providing & laying in position 200mm dia heavy duty PVC rigid pipe "of
3.1 equivalent IS approved make, (ASTM-D-1785, SCHEDULE-80) with heavy
duty GI sockets. Rmtr 80.0 1424.75 113980.16
Providing & laying in position 100mm dia heavy duty PVC rigid pipe (ASTM-
D-1785, SCHEDULE-80) with heavy duty GI sockets. Rmtr 200 1066.24 213248.00
Providing & laying in position100mm dia equivalent IS approved make,
heavy duty PVC ribbed ,Tube well STRAINER, conforming to relevant IS
codes, jointing with 100mm dia. PVC bore well / casing pipe with heavy duty
GI sockets of approved quality. Rmtr 60.00 1317.12 79027.20
Providing & Fixing of following heavy duty PVC / M.S. fittings & fixtures
conforming to relevant IS codes, as described below. :-
5.1 200 mm X 100 dia mm heavy duty PVC reducing socket. No 2.00 564.48 1128.96
5.2 200 mm dia M.S. housing clamps with necessary nut-bolts arrangements. Set 2.00 940.80 1881.60
5.3 200 mm dia heavy duty M.S. Top cap. No 2.00 1191.68 2383.36
100 mm dia heavy duty ( 5 to 6mm thick) M.S. ( C-shaped with minimum
50mm high vertical internally threaded face ) bottom cap. 1630.72
5.6 200mm DIA. x 1' ft long PVC nipple. No 2.00 501.76 1003.52
Providing, laying & filling in layers uniformly grained gravel of size 6mm &
below, surrounding the annular space between the bore well hole and
tappering casing pipe upto a depth of 135 meters or as per site requirement
below ground level including transportation, delivery of material and labour
6.0 for filling up of annular space in layers.
[Mode of Measurement : The gravels will be measured in Cum. Contractor
shall provide stacks of gravel in required size which will be measured to a
nearest centimeter and volume comprising of length x breadth x height,
less 5% (five percent) for voids shall be measured and paid for.
Item Breif Description of works Unit Qty Rate Amount
Surging, Washing and cleaning, rinsing the drilled tube well / borewell by
using desired capacity air compressor with allied accessories for 8 hours a
day including making arrangement for showing yield test at the tube well by
V- notch arrangement.
Mode of Measurement: The log book entries will have to be maintained for
actual hours of using of compressor per day and the payment will be made
by considering a day with minimum 8 ( eight) hours of operation or will be
paid proportionately on the nos. of effective operational hours. Day 6.00 9408.00 56448.00
Carrying out Geophysical investigation of the aquifer by electro logging
8.0 system with all tools and plants as necessary to ascertain the availability /
good yield of water including providing of necessary report. Job 2.00 10035.20 20070.40
Collection of water sample for physical, chemical analysis and
bacteriological analysis by carrying out requisite test from reputed / Govt.
9.0 laboratories /Govt. Engineering collages for potablity of water including for
submission of test report all as directed by the Engineer-in-charge etc
Providing & installing in position three phase 7.5 HP submersible pump
motor set of approved make conforming to relevant IS codes with 50 mtrs.
long 3X6.0 sq.mm. copper cable flat finolex or equivalent approved make
conforming to relevant IS code including providing & fixing control panel ,
starter of approved make including Ammeter, Voltmeter & 32 Amp. SP MCB
including fixing on wall by suitable arrangement all as per direction of EIC
Total for Two nos. Borewell [C-2] 1512328.38
Item Breif Description of works Unit Qty Rate Amount
D DISMANTLING OF EXISTING STRUCTURES.
Non-Schedule Item For Dismantling works :
1 Carefully Dismantling of existing old abandoned single storied & two
storied Building along with the existing Boundary wall by dismantling
manually / mechanically existing Brick walls including from foundations,
RCC Columns including its footings, Beams, Roofing etc., Cutting of
reinforcement including removal of all debris outside the premises and to
vacate the land. All the vacated foundations after removal of Bricks,
Concrete etc, to be filled up by supplying, filling with river sand duly
compacted by watering, ramming all complete. Approximate land area for
dismantling of existing abonded structures is 3000 Sqm. Tenderer may like
to visit the site before quoting.
Total for dismantling works 134400.00
E INTERNAL BITUMINIOUS ROAD
1 Earth work excavation in hard soil or gravelly soil within 50m. Intial lead and
1.5 m. intial lift including rough dressing and breaking clods to maximum
5cm. To 7cm and laying and layers not exceeding 0.3m in depth and as per
direction of the department. CUM 1645.31 172.48 283783.07
2 Supplying, spreading and compacting Sand to required thickness, in layers
not exceeding 150 mm to proper gradient and camber, inundating each layer
by water and packing and ramming layer by layer to achieve desired
compaction, including lighting, guarding, barricading and making adequate
earthen bundh where necessary, curing with water as per direction, mending
cracks and depressions by ramming wherever necessary. (The payment is
to be made on the basis of the finished compacted volume.)
3 Construction of embankment with approved material obtained from borrow
pits with all lifts and leads, transporting to site by mechanical means within a
lead of 5kms, spreading, grading to required slope and compactingto meet
requirement of table 300-2 & Clause 305 of MoSRT&H Specifications for
Road & Bridge works (4th Revision) CUM 351.00 410.12 143952.68
4 Construction of granular sub-base by providing Close graded Granular sub-
base Grading-III material as per table 400-1, spreading in uniform layers
with motor grader on prepared surface, mixing by mix in place method with
rotavator at OMC, and compacting with vibratory roller to achieve the
desired density complete as per Clause 401 of MoSRT&H Specifications for
Road & Bridge works (4th Revision). SQM 263.25 2486.40 654544.80
5 Providing, laying, spreading and compacting stone aggregates of specific
sizes to water bound macadam specification including spreading in uniform
thickness, hand packing, rolling with 3 wheeled steel roller 8-10 tonnes in
stages to proper grade and camber, applying and brooming requisite type of
screening/binding materials to fill up the interstices of coarse aggregate,
watering and compacting to the required density as per Clause 404 of
MoSRT&H Specifications for Road & Bridge works (4th Revision). Grading-
Using Type-B 11.2mm stone screenings. Cum. 526.50 3687.04 1941226.56
6 Providing and applying tack coat with bitumen emulsion using emulsion
pressure distributor at the rate of 0.20 kg per sqm on the prepared
bituminous/granular surface cleaned with mechanical broom as per Clause
503 of MoSRT&H Specifications for Road & Bridge works (4th Revision) On
Item Breif Description of works Unit Qty Rate Amount
7 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone
chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg
and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2
mm size respectively, including a tack coat with hot straight run bitumen,
including consolidation with road roller of 6 to 9 tonne capacity etc. complete
(tack coat to be paid for separately).
With paving Asphalt grade VG - 10 heated and then mixed with solvent at
the rate of 70 grams per kg of asphalt Sqm 2632.50 246.40 648648.00
8 Providing and laying seal coat sealing the voids in a bituminous surface laid
to the specified levels, grade and cross fall using Type-A seal coat with
0.09cum of 6.7mm size chips and 9.80kg. of 60/70 penetration grade of
bitumen for 10sqm as per Clause No. 513 of MoSRT&H specifications for
Road & Bridge works (4th Revision) Sqm 2632.50 97.44 256510.80
9 Providing, laying and making kerb channel 30 cm wide and 50 mm
thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone
aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm
nominal size, well rammed and consolidated and grouted with fine sand,
including finishing the top smooth etc. complete and as per direction of
Engineer-in-charge. Sqm 351.00 480.48 168648.48
10 Providing and laying at or near ground level factory made kerb stone of M-
25 grade cement concrete in position to the required line, level and
curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),
including making joints with or without grooves (thickness of joints except at
sharp curve shall not to more than 5mm), including making drainage
opening wherever required complete etc. as per direction of Engineer-in-
charge (length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Total of E 4895613.35
Total for A+B+C+D+E= 9425103.81
Description Unit Quantity Rate Amount
1.0 Earth work excavation in hard soil or gravelly soil within 50m. Intial
lead and 1.5 m. intial lift including rough dressing and breaking clods
to maximum 5cm. To 7cm and laying and layers not exceeding 0.3m
in depth and as per direction of the department. Cum. 1441.250 172.48 248586.80
2.0 Filling in foundation and plinth with excavated materials, moorum
including watering and ramming as directed by the Engineer-in-
3.0 Providing and Laying plain cement concrete 1: 4: 8 .( 1 cement : 4
sand : 8 stone Aggregate 40mm nominal size ) As levelling course
in foundation and plinth etc. complete all depth and height.
REINFORCED CEMENT CONCRETE WORK
4.0 Providing and Laying reinforce cement concrete M-25Grade, 20 mm
nominal size HBG chips including cost all
materials,labours,T&P,curing etc complete (excluding the cost of
reinforcement) and direction of Engineer-in-charge.
In Ground Floor including Foundation :
(i) For R.C.C. work in 1st floor or any additional floor add 15 per cent
extra labour over and above the rate of next lower floor for lifting of
(v) For R.C.C. and reinforcement works below ground level beyond
1.5m and upto 4.5m depth add 15 per cent extra labour over and
above the rates of the respective items for lowering the materials.
5.0 Centering & Shuttering works :
(i) For centering and shuttering for R.C.C. work (in floor and roof slab,
Landings, Balconies, projecting sunshades, Chajja, Stairs Plinth
band,footings , base of columns, precast slab, beams and columns,
Lintels,R.C.C. Walls and Fins) in first floor and subsequent upper
floors add 20 percent extra to the rate of respective centering and
shuttering items over and above the rates from the next lower floor.
5.1 Rigid and smooth centering and shuttering for R.C.C. works including
false work and dismantling them after casting including cost of
materials complete in ground floor.:
R.C.C. foundation and plinth band, footings, bases of columns, mass
concrete, precast slabs etc. Sqm. 5056.000 113.01 571368.45
5.2 Rigid and smooth centering and shuttering for R.C.C. works including
false work and dismantling them after casting including cost of
materials complete in ground floor.:
(i) R.C.C. Floor roof slabs, landings, balconies, projecting sun-shades
and chajjas upto 4.3m.height. Sqm. 70.000 473.97 33178.10
6.0 Reinforcement works :.
Supplying ,fitting and placing uncoated HYSD bar reinforcement
complete as per drawing and technical specification.
In Ground Floor Qtl. 520.157 9065.34 4715402.10
Description Unit Quantity Rate Amount
Supplying , Laying Single Brick Flat soling below Foundations , Flooring etc.,
7.0 using Clay burnt bricks , including filling gaps with fine sand.
8.0 PLASTERING & POINTING WORK
20 mm cement plaster of mix :
9.0 Neat cement punning Sqm. 3111.000 70.28 218641.08
10.0 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved
steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works Kg 14400.000 114.24 1645056.00
11.0 P/L non-pressure NP2 class (light duty) R.C.C. pipes...jointed with
stiff mixture of CM in the proportion of 1:2 -complete
BOUNDARY WALL AND GATE
EXTERNAL DEVELOPMENT - BOUNDARY WALL
Description Unit Quantity Rate Amount
Earth work excavation in hard soil or gravelly soil within
50m. Intial lead and 1.5 m. intial lift including rough dressing
1.0 and breaking clods to maximum 5cm. To 7cm and laying
and layers not exceeding 0.3m in depth and as per direction
of the department.
1.1 In hard soil or gravelly soil Cum. 748.62 172.48 129121.98
Filling in foundation and plinth with excavated materials
2.0 including watering and ramming as directed by the Engineer- Cum. 421.63 114.99 48483.40
Plain Cement Concrete works :
Providing and Laying plain cement concrete 1: 4: 8 .( 1
cement : 4 sand : 8 stone Aggregate 40mm nominal size )
As levelling course in foundation and plinth etc. complete
all depth and height.
REINFORCED CEMENT CONCRETE WORK
Providing and Laying reinforce cement concrete M-25Grade,
20 mm nominal size HBG chips including cost all
materials,labours,T&P,curing etc complete (excluding the
cost of reinforcement) and direction of Engineer-in-charge.
In Ground Floor including Foundation :
5.0 (i) For R.C.C. work in 1st floor or any additional floor add 15
per cent extra labour over and above the rate of next lower
floor for lifting of concrete etc..
(v) For R.C.C. and reinforcement works below ground level
beyond 1.5m and upto 4.5m depth add 15 per cent extra
labour over and above the rates of the respective items for
lowering the materials.
5.1 In Ground Floor including Foundation : Cum. 374.69 5763.52 2159533.31
Description Unit Quantity Rate Amount
Centering & Shuttering works :
(i) For centering and shuttering for R.C.C. work (in floor and
6.0 Landings, Balconies, projecting sunshades, Chajja, Stairs
Plinth band,footings , base of columns, precast slab, beams
and columns, Lintels,R.C.C. Walls and Fins) in first floor and
subsequent upper floors add 20 percent extra to the rate of
respective centering and shuttering items over and above
the rates from the next lower floor.
Rigid and smooth centering and shuttering for R.C.C. works
including false work and dismantling them after casting
6.1 including cost of materials complete in ground floor.: Sqm. 1834.07 113.01 207264.58
R.C.C. foundation and plinth band, footings, bases of
columns, mass concrete, precast slabs etc.
Rigid and smooth centering and shuttering for R.C.C. works
including false work and dismantling them after casting
including cost of materials complete in ground floor.:
R.C.C. beams, columns, girders and bressmers etc.
Reinforcement works :
7.0 For Reinforcement work in 1st floor or any additional floor
add 5 per cent extra labour over and above the rate of next
Supplying ,fitting and placing uncoated HYSD bar
reinforcement complete as per drawing and technical
In Ground Floor
MASONRY BRICK WORK WITH 25CM. BRICKS :
(i) For brick masonry in superstructure add extra towards
extra labour for scaffolding to the rate in foundation and
plinth. ------- 1 cum 33.00
(ii) For brick masonry in item for 1st floor and subsequent
higher floors add 15 percent extra labour over and above the
rates of next lower floor.
Description Unit Quantity Rate Amount
Brick work with Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm.
size having crushing strength not less than 75 Kg./Cm2 with
dimensional tolerance ± 2 % in cement mortar (1:6) in
foundation and plinth.
Half brick masonry with non modular fly ash bricks of class
designation 75, conformingio IS :12894, in super structure
8.2 above plinth and upto floor V level. Sqm 1689.00 712.32 1203108.48
Cement mortar 1 : 4 (1 cement : 4 coarse sand)
8.3 Supplying , Laying Single Brick Flat soling below Foundations ,
Flooring etc., using Clay burnt bricks , including filling gaps with
Description Unit Quantity Rate Amount
Steel work welded in built up sections/ framed work,
including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer using structural steel
etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works
PLASTERING & POINTING WORK
10.0 Cement Plaster (In Coarse Sand)
Providing & Applying .20mm thick cement plaster (1:4) (1
cement: 4 coarse sand)
Finishing walls with water proofing cement paint of approved
11.0 shade on new work two coats to give an even shade sqm 4501.46 38.08 171415.60
including the cost of cement paint. - In Ground Floor level.
12.0 Applying priming coat :
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound )
With ready mixed pink or grey primer on wood work (hard
and soft wood) having VOC content less than 50 grams/
Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :
13.1 Two or more coats on new work sqm 308.00 82.88 25527.04
NON SCHEDULE ITEMS
Description Unit Quantity Rate Amount
1 SITC of 1000 Kg passenger cum goods lift with machine roomless
Number Of Lifts/Type Of Lift: One Goods Lift
Load / Speed : 1.0 Ton / 1.00 Mtr. Per Second
Drive : MICRO PROCESSOR BASED ACVF - CLOSED LOOP
Travel / PIT / HeadRoom : 4.5 METER / HeadRoom 4500mm
Number Of Floors : 2 (G + 1 UPPER FLOORS)
Number Of Landing Entrances :2 (G + 1 UPPER FLOORS)
Number and Position of Car Entrances : 1 (ONE), IN FRONT ONLY
Position Of Machinery : Machine Room
Size of Lift Well : 2500 mm Width x 2500 mm Depth
Lift Car Inside Size : AS PER NBC 2016
Type or Design of Lift Car Stainless Steel - Hairline Finish -
Car Ceiling - Car Floor : Sleek (Medium Circular Lights) - Ss Hairline Finish
Car Fittings : Bbs 170 Led Light & Axial Flow Fan
Type Of Landing Entrance Protection : Centre Opening Sliding Door - Stainless Steel -
Hairline Finish
Type Of Car Entrance Protection : Power Operated Centre Opening Sliding Door -
Stainless Steel - Hairline Finish
Type Of Landing Frame : Stainless Steel - Hairline Finish
Clear opening of Gates / Doors : 900 X 2000 (MM Wide * MM Height)
Type Of Control: Single car control System Microprocessor Based Full Collective
Control With / Without Attendant
Electric Supply : AC 415 VOLTS, 3 PHASE, 50 CYCLES +10% - 20%
Elevator pit depth : 1650 mm
Signals : All indicator display will be LED
Special features :
1. Automatic Rescue Device with UPS back-up.
2. Battery operated Emergency Light and Alarm.
3. Fireman’s Emergency Operation.
4. Anti-Nuisance Car Call Cancellation.
5. Car Call Cancellation at Terminal Stop.
6. Automatic Operation for Car Light And Fan.
7. Close loop control for main and door drive.
8. Repeated Door Closing in Case Of Lock contact Failure.
9. Voice Announcement System.
10. Over Load Indicator.
11. Phase Failure & phase Reversal Protection.
12. Self-Detection & Indication of Faults.
13. Door System by Light Curtain (81Beam).
14. Car arrival chime
15. Home Landing.
16. VF Door Drive System.
17. Decorative call buttons
18. Braille System
19. Intercom system
20. Necessary fittings for the physically handicapped
21. Traction media will be coated steel belt
NOTE: Contractor should inspect the Site before submitting the offer
All design car size to be in compliance to relevant IS code.
Cost should include following :
i) Builders work, and scaffolding, pit ladder etc.
ii) Cost for providing landing door sills
iii) Cost of structurals to match shaft dimension, if any.
iv) Arrangement for power to cater the demand of constructional load, testing
and commissioning of the lift.
v) Lift pit / shaft lighting.
vi) Landing door frame for landing gate
vii) Unloading at site Nos 1 2032033.81 2032033.81
4 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface / recessed steel conduit,
with piano type switch, phenolic laminated sheet, suitable size MS box and earthing
the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.
5 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the
existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel,
making connections, etc. as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size in the existing masonary open duct as required.
7 Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.
ELECTRICAL SUMMARY
SL.No DESCRIPTION AMOUNT In Rs.
1 SCHEDULED ITEM 7746347.50
2 LOW SIDE ELECTRICAL WORKS (NON-SCHEDULED ITEM) 23602516.52
3 ELECTRICAL HV INSTALLATION WORK (NON-SCHEDULED ITEM) 7073792.28
TOTAL PRIME COST 38422656.30
ELECTRICAL WORK (SCHEDULED ITEM)
Sl. Description Unit Qty. Rate Amount
A. CIRCUIT AND POINT WIRING (SUPPLY, INSTALLATION, TESTING AND
1 Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5
sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with
20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI
marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of
suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand
copper conductor as earth wire including all accesories and connection as per
direction of Engineer in Charge.
2 Recessed wiring for light / power plug with 2 x 4 sq.mm FR PVC insulated single core Meter 585 146.38 85634.64
multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible
conduit alongwith 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper
conductor for loop earthing as required.
3 Circuit / Sub Main wiring in PVC Conduit
Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia
non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR
PVC insulated single core multistrand copper conductor as earth wire as equired.
Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia
non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR
PVC insulated single core multistrand copper conductor as earth wire as equired.
Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand
copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic
heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated
single core multistrand copper conductor as earth wire as equired.
Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia
non-metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 4 sq.mm FR PVC
insulated single core multistrand copper conductor as earth wire as equired.
4 Supplying and fixing of following sizes of Steel conduit along with accessories in
recessed wiring including cutting the wall and making good the same in case of
recessed conduit as required.
5 Supplying and fixing of following sizes of PVC conduit along with accessories in
recessed wiring including cutting the wall and making good the same in case of
recessed conduit as required.
Sl. Description Unit Qty. Rate Amount
6 Supply and drawing of following sizes FR PVC insulated single core multistrand
copper conductor in existing surface / recessed STEEL/PVC conduit as required.
7 Supplying and fixing of following sizes of Metal Box along with accessories in
recessed wiring including cutting the wall and making good the same in case of
recessed conduit as required.
8 Supplying and fixing of metal box of 150 mm x 75 mm x 60 mm deep (nominal size) Each 198 483.95 95822.50
on surface or in recess with suitable size of phenolic laminated sheet cover in front
including providing and fixing 3 pin 5 / 6 amps socket outlet and 5 / 6 amps piano type
switch, connection, painting etc as required.
9.7 Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase Each 4 146.16 584.64
230 volts complete as required.
TOTAL CARRIED TO SUMMARY 5468566.99
B. LV / MV CABLE TRENCHING AND LAYING WITH SAND AND PROTECTIVE
1 MV cable laying up to 25 sq.mm in ground
1.1 Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 Metre 144 222.10 31981.82
KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand
cushing, protective covering and refilling the trench etc. as required.
1.2 MV cable laying exceeding 25 sq.mm to 120 sq.mm in ground Metre 240 230.05 55211.52
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1
KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground
including excavation, sand cushioning, protective covering and refilling the trench etc.
1.3 MV cable laying exceeding 120 sq.mm to 400 sq.mm in ground Metre 30 238.00 7140.00
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1
KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground
including excavation, sand cushioning, protective covering and refilling the trench etc.
2 LALYING OF CABLE ON SURFACE
2.1 MV cable laying up to 25 sq.mm on surface Metre 576 48.38 27869.18
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power
cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required.
2.2 MV cable laying exceeding 25 sq.mm and up to 120 sq.mm on surface Metre 720 73.58 52980.48
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power
cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on
surface as required
TOTAL CARRIED TO SUMMARY 175183.01
C. EARTHING INSTALLATION
1 G.I. Earth Pipe electrode with salt / charcoal Set 48 2884.45 138453.50
Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories
and providing masonary enclosure with cover plate having locking arrangment and
watering pipe etc with charcoal and salt as required
Sl. Description Unit Qty. Rate Amount
2 S/L of 25 mm x 5 mm Copper earth strip in 40 mm dia G.I. pipe Metre 960 707.84 679526.40
Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth
electrode as required.
3 S/L of 25 mm x 5 mm G.I. earth strip in 40 mm dia G.I. pipe from earth electrode as Metre 1800 665.39 1197705.60
4 P/F 6 SWG GI loop earth wire in surface / recess Metre 4000 21.73 86912.00
TOTAL CARRIED TO SUMMARY 2102597.50
ELECTRICAL SUMMARY
Item Description Amount
A. CIRCUIT CUM POINT WIRING (IN RECESSED / SURFACE PVC/ MS CONDUITS) ` 5468566.99
B. CABLES, MAINS AND SUB MAINS ` 175183.01
C. EARTHING INSTALLATION ` 2102597.50
GRAND TOTAL ` 7746347.50
GRAND TOTAL ` 7746347.50
LOW SIDE ELECTRICAL WORKS (NON-SCHEDULED ITEM)
Item Description Unit Qty. Rate Amount
A. CIRCUIT AND POINT WIRING (SUPPLY, INSTALLATION, TESTING AND
1 Wiring for AC point with 4 sq. mm. Insulated copper conductor 1100 volts grade stranded Pt 26.40 1578.64 41676.10
flexible FRLS wires of approved make in concealed minimum 2mm thick FRLS PVC
conduit (as per IS 9537 part 3) including providing and fixing of 20 amps flush mounted
switch at the normal switch level in 1.6 mm thick GI box and 32 amps 3 pin metalclad
socket outlet with ON indicator with lockable acrylic door and earthing of through the
third pin of the socket outlet and GI box with 2.5 sq. mm. PVC insulated copper
conductor flexible FRLS wire.
2 Wiring for Geyger point with 4 sq. mm. Insulated copper conductor 1100 volts grade Pt 5.50 1024.46 5634.55
stranded flexible FRLS wires of approved make in concealed minimum 2 mm thick FRLS
PVC conduit (as per IS 9537 part 3) including providing and fixing of 20 amps SP MCB in
1.6 mm thick GI box and32 amps 3 pin metalclad socket outlet (IP 56) with On indicator
with lockable acrylic door and earthing of through the third pin of the socket outlet and GI
box with 2.5 sq. mm. PVC insulated copper conductor flexible FRLS wire.
3.0 Supply, laying, installation, testing and commissioning of following PVC insulated tinned
copper conductor cable / wires in existing cable tray / GI pipes / conduits.
3.1 10 pair 0.5/0.61 mm armoured cable Meter 394.84 115.14 45460.80
4 Supply and installation, testing and commissioning following size KRONE make
telephone tag block in lockable 16 gauge sheet steel enclosure complete as required.
9.0 Supplying and fixing following modular switch/ socket on the existing modular plate &
switch box including connections but excluding modular plate etc. as required.
9.3 3 pin 5/6 amp socket outlet Each 165.00 115.58 19071.36
9.4 6 pin 15/16 amp socket outlet Each 42.90 224.22 9619.21
9.5 Telephone socket outlet Each 22.00 125.44 2759.68
9.6 TV antenna socket outlet Each 14.30 125.44 1793.79
10 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Meter 100.00 46.82 4681.60
steel/ PVC conduit as required.
11 Supplying and fixing modular blanking plate on the existing modular plate & switch box Each 103.40 32.03 3312.11
excluding modular plate as required.
12 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper
conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC
conduit as required.
TOTAL CARRIED TO SUMMARY 311639.05
B. CABLES, MAINS AND SUB MAINS
The rate shall also include the following :
1 Providing and fixing junction boxes with covers including painting.
2 Effecting adequate and proper connections at terminations.
Item Description Unit Qty. Rate Amount
3 Providing all fixing accessories such as clamping devices nuts, bolts and screws.
4 Excavation laying of cable filling of sand, brick protection, back filling of earth, watering,
ramming and making good.
5 Wherever the cables are of aluminium and bus bars of copper bimetallic lugs shall be
6 All cable shall be laid with one diameter gap.
7 All cables shall be IS approved.
8 Fire retardent paint one meter on both side of wall penetration and at termination as per
specifications.
9 Burried LT cables to be laid atleast 750 mm below ground.
10 All cutouts / Sleeves shall be sealed with fire redardant sealent as per specification.
11 No joints are allowed in the cable.
B. CABLES, MAINS AND SUB MAINS
1.0 Supplying of following 1100 volt grade XLPE insulated PVC sheathed aluminium
conductor armoured cables as per specification.
2.0 Supplying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor
armoured cable as per specification.
3.0 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable
of 1.1 KV grade of following size on cable tray as required.
3.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 6990.00 24.08 168319.20
3.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3 mm MS flat clamp) Metre 1350.00 47.60 64260.00
3.3 Above 95 sq. mm and upto 240 sq. mm (clamped with 25/40x3mm MS flat clamp) Metre 1500.00 59.02 88536.00
4.0 Supplying and making end termination with brass compression gland and aluminium lugs
for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable
of 1.1 KV grade as required.
Item Description Unit Qty. Rate Amount
5.0 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with Each 40.00 428.96 17158.40
inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long
and fixing the same in ground as required.
6.0 Providing, laying and joining in position HDPE pipes conforming to IS:4984-1987
(Material Grade -PE- 80)/ or equivalent international standard and suitable for the
respective working pressures with all fittings and specials,e.g.couplings, tees, bends,
reducers, end plugs etc., jointing by fusion welding method as per manufacturers
recommendations all complete including excavation in all kind of soil and back filling.
This pipes will be used for transferring HV/LV Cables.
7.0 Supply and installation of following RCC (NP-2 class) Hume pipe under paved areas,
including providing 75 mm thick cement concrete all around pipe 1:3:6 (1 cement, 3
coarse sand and 6 crushed stone aggregate).
TOTAL CARRIED TO SUMMARY 5451758.76
C. CABLE TRAYS AND RACEWAYS:
The cable management system shall comprise:
1 Ladder cable trays and supports.
2 Perforated cable trays and supports.
3 Surface mounted wire ducts with brackets/ supports.
4 All cuts/perforations/folded sections where contact with wires/cables in expected shall be
5 Zinc coating shall be 120 gm/ square meter or more. The materials shall conform to
relevant IS/ BS standards for the category/ application specified.
6 The cable tray shall be factory built. Only cutting to achieve assembly system length shall
be permitted at site.
7 Accurate fabrication formed section with tolerances of + 2 mm on width and + 5 mm on
length expected.
8 Dimensional and general arrangement drawing of the system are expected to be
provided by tenderer/ cable tray/ duct supplier.
9 The system shall be designed for installation with a temperature classification of + 60
10 The cable tray/duct systems shall be suitable for against corrosion.
11 Details of fixing supports etc. shall be submitted for approval.
C. CABLE TRAYS AND RACEWAYS:
1.0 Supply and installation of under floor GI raceway with necessary hardware including of
supporting with threaded hitech rods etc. complete,
1.1 200 mm wide x 40 mm deep raceway Metre 80.00 3241.39 259311.58
1.2 150 mm wide x 40 mm deep raceway Metre 200.00 2141.42 428283.78
2.0 Providing and fixing of 250 x 250 x 60 mm deep (Nominal size) junction box including Each 20.00 3344.88 66897.60
providing 3 mm thick GI steel cover required as per specification.
Item Description Unit Qty. Rate Amount
3.0 Providing and fixing of 200 x 200 x 60 mm deep (Nominal size) junction box including Each 40.00 2767.48 110699.01
providing 3 mm thick GI cover required as per specification.
4.0 Supply and fixing of pregalvanized factory fabricated GI ladder (or equivalent wire mesh
as per specification) type cable tays, with radial bends, supports and fixing hardware etc.
with of the following sizes as per specification.
4.2 1000 mm wide
Runners 25 x 100 x 25 x 3 mm
Rungs 20 x 40 x 20 x 3 mm 250 mm C/C
2 No. suspenders 40 x 40 x 5 mm GI angle 1500 mm C/C (1 vertical and 1 horizontal RM 40.00 2,454.76 98,190.42
welded and bolted) with 2 No. GI hangers for support as per site requirement
4.3 750 mm wide
Runners 20 x 75 x 20 x 2.5 mm
Rungs 20 x 30 x 20 x 2.5 mm 250 mm C/C
2 No. suspenders 32 x 32 x 4 mm GI angle 1800 mm C/C (1 vertical and 1 horizontal RM 1200.00 1,714.56 2,057,471.81
welded and bolted) with 2 No. GI hangers for support as per site requirement
5.0 Supply and fixing of perforated type (or equivalent wire mesh type) GI cable trays with
support for hanging from the ceiling of the following sizes as per specification.
TOTAL CARRIED TO SUMMARY 3340870.68
E CONVENTIONAL LIGHTNING PROTECTION SYSTEM
1.0 Supply of Vertical Electrolytic Copper Lighting Arrester of 16 mm dia, 1000 mm long Nos. 55.00 4,162.82 228,954.88
with Gun Metal base plate .
2.0 Supply 8 mm round aluminium conductor for horizontal lightning protection - run in roof. RM 594.00 200.34 118,999.30
3.0 Supply of roof conductor holder for 8 mm round aluminium conductor made of Gun Nos. 599.50 243.26 145,837.10
Metal for horizontal installation. The distance between each holder should be min of 1
4.0 Supply of T connector for connecting of 8 mm Al round conductor . The connector Nos. 57.20 637.43 36,461.06
should be of Gun Metal with SS nuts and bolt.
5.0 Supply of Cross connector for connecting of 8 mm Al round conductor . The connector Nos. 28.60 637.43 18,230.53
should be of Gun Metal with SS nuts and bolt.
6.0 Supply of Expansion piece along with connector to compensate the expansion of round Nos. 68.20 689.47 47,021.61
8 mm Al conductor when temperature variation . Connection should be in every 20 mtr.
7.0 Supply of 8 mm round aluminium conductor as a down conductor mounted in the RM 385.00 200.34 77,129.18
surface of wall which will carry the lightning current to earth pit.
8.0 Supply of Down conductor holder for 8 mm round aluminium conductor of min distance Nos. 385.00 247.17 95,159.37
between the wall to the conductor will be of 85 mm. The distance between each holder
should be min of 1 mtr.
9.0 Supply of straight connector for connecting of 8 mm Al round conductor . The connector Nos. 39.60 637.43 25,242.28
should be of Gun Metal with SS nuts and bolt.
Item Description Unit Qty. Rate Amount
10.0 Supply of 6 digit lightning strike counter. Nos. 2.20 17,561.88 38,636.14
11.0 Supply of Test Joint Point for 8 mm round aluminium conductor, the size should be of Nos. 22.00 6,244.22 137,372.93
25 x 3 x 150 mm copper in ABS boxes.
12.0 Supply of UL approved low carbon high tensile steel rod with copper coating of min 254 Nos. 55.00 18,862.76 1,037,451.80
micron JK Chemrode - 317 CBR the dia should be 17.2 mm with length of 10 feet ( 3000
mm) . The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be
tested from NABL lab for current discharge not less then 46kA peak.
The Chemrode shall be surrounded with 25 kg ( 1 bag) of Earth enhance materiel JK
Reslow according to IEC 62561-7 and the Chemical resistance value shall not increase
more then 0.067 Ωm and same will be tested from NABL lab. along with earth pit
chamber made up polyplastic. Size of -254x330x260 MM
13.0 Providing and fixing G.I. tape 25 mm X 6 mm thick on parapet or surface of wall for RM 550.00 221.15 121,632.28
lightning conductor complete as required.
TOTAL CARRIED TO SUMMARY 2,128,128.45
F SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIGHTING
FIXTURES, CEILING FANS, EXHAUST FANS AND ACCESSORIES
The rates shall include all components that may be required to make the installation
complete in all respects such as :
1 Including All lamps, accessories & electronic ballast unless otherwise specified.
2 Internal wiring between accessories.
3 Earthing terminal.
4 Complete provision for installation.
5 The vendors should select the fixtures according to lux level given in drawings & LPD
shall be maintained below 0.7W/sqft.
6 The vendors should Submit the detailed lux level calculation & LPD calculation.
7 Suitable length of GI down rod, hanger and connecting wires where called for..
8 Wires for connecting the fixtures to the point through connector block.
9 All metal blocks to serve as base of fixtures..
10 Bonding with earth wires.
11 Drilling holes in supports wherever required.
12 Bonding with earth wires.
13 Fixing clamps, GI bolts and nuts, brass screws, saddles, rawl bolts and other fixing
accessories as required.
14 Testing of all fixtures before and after installation.
F SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIGHTING
FIXTURES, CEILING FANS, EXHAUST FANS AND ACCESSORIES
1.0 Supply, Receiving, storing, installation & handling of following lighting fixtures/ Ceiling
Fan/ Exhaust Fan with all fixing accessories etc. as required.
1.1 Wall/ surface mounted T8 light fixture complete with 1X20 W (LED) lamps, ballast and Each 1471.80 1339.52 1971505.54
all accessories as required .
Item Description Unit Qty. Rate Amount
1.2 Wall/ surface mounted T8 light fixture complete with 2X20 W (LED) lamps, ballast and Each 35.20 2163.84 76167.17
all accessories as required.
1.3 Supply of Surface mounted Round 18/20 W LED Downlight fixture complete with all Each 621.50 2009.28 1248767.52
accessories as required.
1.4 Decorative Bracket light with 9W LED lamp Each 15.40 2016.00 31046.40
1.5 Aesthetic Wall Mounted mirror light luminaries suitable 10W 2' LED mirror for higher light Each 36.30 865.54 31418.96
1.7 LED Trackmounted projector light with system lumen of 4000 @ system load of 41W.+ 3 Each 6.00 6182.40 37094.40
nos. 1 mtr. Track
1.8 Bulk Head lighting fixture 10W, 1000 Lumen Each 44.00 875.84 38536.96
1.15 48" dia sweep ceiling fan (BEE 5 star rated) with step type modular fan regulator of Each 273.90 2032.13 556599.86
approved make complete with all accessories.
1.16 Exhaust Fan 225 mm sweep (Heavy duty) . Each 39.60 2483.71 98355.00
TOTAL CARRIED TO SUMMARY 4089491.80
G. SUPPLY, INSTALLATION OF LIGHTING FIXTURES AND SUPPLY &
INSTALLATION OF CABLES FOR EXTERNAL/ LANDSCAPE LIGHTING
1.0 Suplying, Receiving, storing handling, installing, testing and commissioning of the
following lighting fixtures.
1.1 Light fixtures of 80W LED flood light with LED lamp or approved equal in quality and No. 8.00 11849.60 94796.80
1.2 LED type Bollard lighting fixture 7W, with lamp and ballast as per requirement or No. 15.00 8758.40 131376.00
approved equal in quality .
1.3 Street Light fixture of 20 W LED of IP 66 protectioncomplete with lamp, electric ballast No. 16.00 4121.60 65945.60
etc as required.
1.4 7M high MS decorative poles (5.6 M above & 1.4 M below ground) Kesselec Make No. 8.00 20865.60 166924.80
Blenheim model or equivalent
1.5 Supply of 4m Octagonal GI pole with top dia of 70mm, botoom dia 130 mm, base plate No. 16.00 11592.00 185472.00
dimension of 200mmX200mmX12mm; PCD of 225 mm and Sheet thickness of 3mm.
Along with 4 Nos. foundation bolts. Similar to Wipro make 4m Pole or equivalent
Philips/LT Make.
2.0 Providing and fixing of following PVC insulated copper conductor 1100 volts grade
stranded flexible wire in GI conduit including providing and fixing of conduit concealed or
surface mounted as indicated PVC insulated green colour copper stranded flexible wire
for earthing and making connection complete.
2.1 3 x 4 sq.mm wire in 25 mm dia conduit. RM 650.00 322.56 209664.00
2.2 3 x 2.5 sq.mm wire in 25 mm dia conduit. RM 200.00 292.32 58464.00
3.0 Providing, installation, testing and commissioning of 200 x 150 x 125 mm polycarbonate Nos. 34.00 4334.40 147369.60
weather proof (IP-55) junction box recessed in wall or surface mounted as required for
housing of 1 no. 10 amps SPN MCB‟s suitable size of terminal blocks complete.
Suitable length of GI pipe up to junction box shall also be provided for laying of cables.
4.0 Supply, installation, testing and commissioning of following polycarbonate weather proof
(IP-55) junction box suitable for pole mounting / underground complete as required.
TOTAL CARRIED TO SUMMARY 1340287.20
H. SYNCHRONIZATION PANEL/ LT PANELS/ DISTRIBUTION BOARDS AND BUS
Item Description Unit Qty. Rate Amount
The main LT panel cum DG Synchronization panel and APFC panel shall be
designed as per IEC 61439-1 & 2 for Total Type tested Assembly (TTA); IP-42 and
seismic zone protection level-3. The rates for the distribution boards from the breakers
and instruments shall also include the following :
1 Supporting rigid steel framework.
2 Cubicle type, 2 mm CRCA sheet steel enclosed & Type 3b (4b for TTA) modular
3 Complete with interconnections and distribution bus bars along with connector strip.
4 Inert gas fire suppresiion system inside the panel compartments
5 Proper bonding to earth as per standard.
6 Painting/lettering on Breakers and distribution boards, the location they serve, providing
on each panel its circuit diagram.
7 Providing cable clamps / supports within distribution boards cable alley.
8 TPN ACB‟s / MCCB‟s shall mean 3 pole ACB‟s / MCCB‟s with adequate size of neutral
9 All MCB‟s shall be of minimum 10 KA breaking capacity.
10 The breaking capacity of MCCB‟s are mentioned panel wise. The releases of MCCB‟s
shall be as per BOQ, SLD and as per following:
i. MCCB rating upto 250 amps with thermal magnetic releases
ii. MCCB rating above 250 amps with microprocessor based releases.
11 Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-
12 Degree of protection for following type of distribution panel enclosure shall be as per
i. IP 42 for indoor panels.
ii. IP 55 for outdoor panels.
13 All MCCB‟s shall be provided with operating mechanism for door interlock.
14 All main bus bars shall be fabricated out of electrolytic grade copper having current
density of 1.4A/ Sq.mm or aluminium having current density of 0.7A/ Sq.mm as per SLD
and BOQ for design consideration.
15 GI earth bus shall be provided through out the length of each board as per schematic
16 All measuring instruments (Meters) shall be of digital electronic (LED Type) of approved
17 All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
18 All panels shall have provision of the following:
19 Pad locking of MCCB‟s handles in “OFF” Position.
20 All MCB‟s used for protection of resistive and lightly inductive load shall be type “B”
characteristic and inductive (motor) load shall be of type “C” characteristic and discharge
lamps and UPS etc. shall be of type D characteristic.
Item Description Unit Qty. Rate Amount
21 All incoming and outgoing air circuit breakers shall be placed on middle portion of the
vertical in single tier formation.
22 CT‟s shall be properally mounted and clamped. Connection of CT‟s for measuring
instrument / relays shall be done through connector / terminals.
23 Model, current capacity location and frame size of switchgear shall be written inside of
the panel doors with paint / permanent marker as approved shop drawings / site
24 Compliance to the technical specifications.
H MAIN LT PANELS/ DISTRIBUTION BOARDS AND BUS DUCTS
Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading,
shifting to location, inspection, installation, testing and commissioning of M.V.Distribution
Boards suitable for 415V, 3 phase, 4 wire, 50 Hz distribution system (Design verified as
per IS/ IEC: 61439- 1 & 2) fabricated out of 14 gauge CRCA sheet steel in cubicle
formation, compartmentalized, form 4b consutruction, free standing floor mounted, dust
and vermin proof with reinforcement of suitable size angle iron, channel, `T‟ sections
and/ or flats wherever necessary. 16 gauge CRCA sheet steel shall be used for final
distribution panels. 3 mm thick cable gland plates shall be provided on top as well as at
the bottom of the panels. Panels shall be treated with all anticorrosive process before
powder coating as per specifications and final approved shade. The panel shall also
include inbuilt inergent gas based fire suppression system inside the panel.
2 No. earthing terminals shall be provided for all distrtibution panels. Panels shall be
suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be
provided in case of large panels. Approval shall be taken for each panel in the form of
shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be
used in fabrication of panels.
SYNCHRONIZATION PANEL/ MAIN LT PANEL/ OTHER TTA PANELS
Supply, Installation, Testing and Commissioning of cubicle type DG
SYNCHRONIZATION PANEL/ MAIN LT CUM DG CHANGE-OVER PANEL AND
OTHER TTA PANELS as per IEC 61439-1 & 2, IP 42 (Design verified) with seismic
zone protection -3, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system,
tested for 12 kV impulse withstand voltage,form 4b construction, fabricated in
compartmentalized modular design from CRCA sheet steel of 2 mm thick for frame work
and covers, plates i/c cleaning & finishing complete with 7 tank process for powder
coating in approved shade, having TPN electrolytic grade copper bus bars for high
conductivity, SMC bus bar supports,with short circuit withstand capacity of 50 KA for 1
sec, internal arc containment tested IEC 61641 50 kA for 0.3 sec at HBB, VBB & Cable
Chamber, bottom base frame of not less than 75 mm thickness, fabrication shall be done
in transportable sections, entire panel shall have a common earth bar sized for
prospective earth fault , solid / flexible connections from of the engineer-in-charge. The
product performance shall carry guarantee for 10 years against any leakage.
For all surface.val and laying 15 mm thick densified edges calicum silicate ceiling tiles of
approved texture in the grid, including, cutting/ making opening for services like diffusers,
grills, light fittings, fixtures, smoke detectors etc., n all respect and must follow tech
specs & drawings.
1.0 AUTO STARTING, AUTO SYNCHRONIZING, AUTO LOAD SHARING AND LOAD
BUS SECTION - I
Incoming Air Circuit Breaker- (From 400 kVA Transformer 1)
800 amps 4 pole, 50 kA, electrically operated fully draw out type air circuit breaker with
microprocessor release unit (Type 6.0H of Schneider or equivalent), for short circuit,
over current and earth fault protection with adjustable setting as per specification and
with following accessories- 1 set :
Item Description Unit Qty. Rate Amount
i Digital load manager (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-
I with 2 No. 800/5 amps 15VA CTs.
ii Phase indicating lamps protected by 6 amps SP MCB‟s- 3 Set
iii Three Phase Under voltage relay MV12 or equivalent (27) - 1 Set
iv Three Phase Over voltage relay MV 12 or equivalent (59) - 1 Set
v Breaker ON/ OFF/ TRIP indicating lights with control MCB‟s- 1 Set
vi 24 V DC Shunt trip coil. - 1 Set
vii 240 V AC under voltage release. - 1 Set
viii Auto-manual / test selector / switch - 1 Set
ix Breaker control switch - 1 Set
x Auxiliary contacts required for necessary interlocking of breakers.
xi Three phase Voltage sensor relay shall be protected by 2 amps TP MCB‟s-1 Set
xii Transient voltage class B surge supressor (100 kA) (Lines to Neutral) & (Neutral to
Earth) suitable for 3 phases - 1 Set
xiii Digital voltmeter with inbuilt selector switch- 1 set
Incoming Air Circuit Breaker-(From 500 kVA DG)
1000 amps 4 pole, 50 kA, electrically operated fully draw out type air circuit breaker with
microprocessor release unit (Type 6.0P of Schneider make or equivalent), for short
circuit, over current and earth fault protection with adjustable setting as per specification
and with following accessories- 1 Set :
a DG controller with AMF of Cummins / Woodword / DEIF/ DEEP SEA or equivalent make
with following measurement and protection features:
i over speed, under speed, speed/ frequency mismatch, excitation failure protection for
ii Over load, short circuit, reverse power, unbalance load, inst. Over current, event
recorder for Alternator
iii Auto/Manual/OFF mode, soft keys for speed raise lower and frequency raise lower
(required for manual mode). Configurable discrete alarm inputs, configurable discrete
iv Communication protocols such as CAN bus/ RS 485/ other open protocol
b Digital Load manager (conzerve – EM 6400 or equivalent with RS 485 and open protocol
for BMS) of accuracy class-I, with 3 Nos. 1000/5A amps 15VA class 1.0 CTs to measure
and display the following electrical quantities :
i Total active energy (KWH/MWH)
ii Maximum demand (KVA/MVA) (KW/MW)
iii Maximum demand reset count.
iv Instantaneous power factor
v Logging of active energy eight time of a day
Item Description Unit Qty. Rate Amount
viii Frequency / Harmonics
c Battery charger as described in the Specifications and described below:
i AC Input : 230 V + 10% AC 50 Hz single phase.
ii DC Output : To float / boost charge suitable number of batteries and also supply a
continuous load.
iii Current Rating: 40 amps
iv Float Mode: 27.0 V nominal (Adjustable) between 24-28.0 V.
v Boost Mode: 29.0 V nominal (Adjustable) between 24-32.0 V.
vi Voltage Regulation: + 2% for AC input variation of 230 V + 10%. Frequency Variation of
50 Hz + 5% and DC load variation 0-100%
vii Ripple: Less than 5%
d 3 Nos. phase indicating light with 2A control MCB‟s and toggle switches.
e Breaker ON / OFF / TRIP/ Trip circuit healthy indicating lights with control MCB‟s. - 1
f 0-500 volts digital electronic voltmeter with selector switch and control MCB‟s.
g 3 nos. 1000/5A, 5VA line CTS for controller
h 3nos. 415/110V line PTs with control fuses, for feedback to controller.
i Grid supply voltage sensing relay.
j Battery charger voltmeter of range 0-50V and ammeter of range 0-50A for trickle and
boost charging.
k Excitor field DC voltmeter and ammeter.
l Lockable Emergency stop push button.
m Three indicating lamps 'load on set‟, „Load on Mains‟ and 'Set fail to start‟.
n Restricted Earth Fault Relay including all accessories.
o 16 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as
required as per specification.
p Five push buttons – start, stop, reset, test and accept.
q Over voltage and under voltage relays.
r Master trip relay, trip circuit supervision relay and cranking relay.
1000 A TPN electrolytic grade Al bus bar, 50 kA for 1 sec. with colour coded heat
shrinkable insulation sleeve.
i. 400 amps, 50kA, 3 Pole MCCB - 1 No. (For 125 kVAr CAPACITOR PANEL 1)
ii. 400 Amps, 50 kA, 4 Pole MCCB - 1 no.
iv. 250 Amps, 50 kA, 4 Pole MCCB - 1 no.
v. 160 Amps, 50 kA, 4 Pole MCCB - 2 nos.
Item Description Unit Qty. Rate Amount
vi. 63 Amps, 50 kA, 4 Pole MCCB - 3 nos.
Bus Coupler 1 (Between Bus Section I & Bus Section II)
1000 amps, 50 kA, 4 pole electrically operated fully draw out type air circuit breaker
without release unit ,with ON/ OFF/ TRIP indicating lamps with control MCB‟s, breaker
control switch etc - 1 Set.
Incoming Air Circuit Breaker- (From 400 kVA Transformer 2)
800 amps 4 pole, 50 kA, electrically operated fully draw out type air circuit breaker with
microprocessor release unit (Type 6.0H of Schneider or equivalent), for short circuit,
over current and earth fault protection with adjustable setting as per specification and
with following accessories- 1 set :
i Digital load manager (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-
I with 2 No. 800/5 amps 15VA CTs.
ii Phase indicating lamps protected by 6 amps SP MCB‟s- 3 Set
iii Three Phase Under voltage relay MV12 or equivalent (27) - 1 Set
iv Three Phase Over voltage relay MV 12 or equivalent (59) - 1 Set
v Breaker ON/ OFF/ TRIP indicating lights with control MCB‟s- 1 Set
vi 24 V DC Shunt trip coil. - 1 Set
vii 240 V AC under voltage release. - 1 Set
viii Auto-manual / test selector / switch - 1 Set
ix Breaker control switch - 1 Set
x Auxiliary contacts required for necessary interlocking of breakers.
xi Three phase Voltage sensor relay shall be protected by 2 amps TP MCB‟s-1 Set
xii Transient voltage class B surge supressor (100 kA) (Lines to Neutral) & (Neutral to
Earth) suitable for 3 phases - 1 Set
xiii Digital voltmeter with inbuilt selector switch- 1 set
i. 400 amps, 50kA, 3 Pole MCCB - 1 No. (For 125 kVAr CAPACITOR PANEL 1)
ii. 400 Amps, 50 kA, 4 Pole MCCB - 1 no.
iv. 250 Amps, 50 kA, 4 Pole MCCB - 1 no.
v. 160 Amps, 50 kA, 4 Pole MCCB - 2 nos.
vi. 63 Amps, 50 kA, 4 Pole MCCB - 3 nos.
Note on Main LT cum DG Changeover Panel :
All outgoing feeders shall have suitable range of followings:
i. All breakers shall be electrically interlocked as per schematic diagram.
ii. All ACB‟s/ MCCB‟s shall be suitable for 50 KA breaking capacity unless otherwise
Item Description Unit Qty. Rate Amount
iii. PLC for DG and transformer load management and supervision to be provided.
iv. Three phase indicating lamps shall be protected by 6 amps SP MCBs.
v. All outgoing feeders shall be provided with built-in short circuit & earth fault relay module.
vi. All outgoing (except spare feeder) shall have dual Electronic energy meter (EM-6438
with RS-485 or equivalent) with required number of CT's as required.
vii. Wiring and supply, installation of space heater, humidistat and control MCB‟s shall be
provided all vertical sections.
viii. Suitable danger board shall be provided.
ix. All bus bar section/ backside panels shall have pad locking facility and hinged type door.
x. 9 W fitting with CFL lamp, switch shall be provided in each vertical section.
xi. Incoming breakers shall have suitable provision for bus duct connection..
xii. All Electronic Energy meter shall be pre wired for BMS connection up to central point
within the panel with shielded cable.
DG Synchronization cum Changeover Panel as described above. Set 1.00 2,323,552.00 2,323,552.00
2.0 MAIN BUILDING DISTRIBUTION PANEL (MDB - 1.1)
400 Amps 4P MCCB with microprocessor based release and with following accessories:
i Dual source digital electronic energy meter with inbuilt selector switch and 400/5 amps
15 VA, CL 1 CTs . - 1 Set
ii Phase indicating light shall be protected by 2 amps SP MCB's. - 3 Set
500 amps TPN Aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set
i. 200 Amps 4 Pole MCCB with Thermo-magnetic release- 2 Nos.
ii. 100 Amps 4 Pole MCCB with Thermomagnetic release- 3 Nos.
iii 63 Amps 4 Pole MCCB with Thermomagnetic release- 8 Nos.
i. All MCCB's shall be of 25 KA (Ics) breaking capacity.
ii All MCB's shall be of 10 KA breaking capacity.
iii. All the outgoing feeders shall have Direct / CT operated VAF meters of accuracy class-
MDB - 1.1 described as above. Set. 1.00 631635.20 631635.20
3.0 GUEST HOUSE DISTRIBUTION PANEL (MDB 1.2)
Item Description Unit Qty. Rate Amount
160 Amps 4P MCCB with microprocessor based release and with following accessories:
i Dual source digital electronic energy meter with inbuilt selector switch and 160/5 amps
15 VA, CL 1 CTs . - 1 Set
ii Phase indicating light shall be protected by 2 amps SP MCB's. - 3 Set
200 amps TPN Aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set
i. 100 Amps 4 Pole MCCB with Thermomagnetic release- 1 Nos.
ii. 63 Amps 4 Pole MCCB with Thermomagnetic release- 8 Nos.
i. All MCCB's shall be of 25 KA (Ics) breaking capacity.
ii All MCB's shall be of 10 KA breaking capacity.
iii. All the outgoing feeders shall have Direct / CT operated VAF meters of accuracy class-
MDB - 1.2 described as above. Set. 1.00 221793.60 221793.60
4.0 UPS OUTPUT PANEL
A. Incoming (From 30 kVA UPS)
100 Amps, 4 pole, 35 kA MCCB
VAF digital electronic meter with inbuilt selector switch -2 Sets
Phase indicating light shall be protected by 6 Amps SP MCB's - 6 Set
150 Amps TP+2N electrolytic grade Copper bus bars, 35 kA with colour coded heat
shrinkable insulation sleeve. - 1 Set
i. 40 Amps DP MCB - 14 Nos. (6 Nos. for ELDBs, 1 No. for ELV DB and 4 Nos. as
i. All MCCB's shall be of 35 KA (Ics) breaking capacity.
ii. All MCB's shall be of 10 KA breaking capacity.
iii. Frequency and impedance matching between two incomers.
UPS OUTPUT PANEL as described above. Set. 1.00 127,512.00 127,512.00
5.0 EXTERNAL LIGHTING PANEL (IP-55)
A. Incoming (From Emergency panel Bus section II)
Item Description Unit Qty. Rate Amount
One(1) - 80A, TPN, 35 kA MCCB with thermo-magnetic release with following
VAF digital electronic meter with inbuilt selector switch and 100/5 Amps suitable VA, CL
Phase indicating light shall be protected by 6 Amps SP MCB's - 3 Set
150 Amps TPN electrolytic grade Aluminium bus bars, 35 kA with colour coded heat
shrinkable insulation sleeve. - 1 Set
i. 2 Set each having "12 Nos. 16/20/25 amps SP MCB with 3 Nos. 63 amps DP ELCB per
phase as outgoing with 1 No. 0-24 hour timer switch, 1 No. 70 amps TP Contactor and 1
No. 63 amps MCB" as incoming , push button etc complete as required.
ii. 25 Amps 4P MCB + ELCB - 4 Nos. (3 Nos. for utility points and 1 No. as spare).
i. All MCCB's shall be of 35 KA (Ics) breaking capacity.
ii. All MCB's shall be of 10 KA breaking capacity.
iii. All ELCB's shall be of 100 mA sensitiviity.
iv. The External Lighting panel shall be finalized after finalization of area lighting layout.
EXTERNAL LIGHTING PANEL described as above Sets. 2.00 182,187.60 364,375.20
6.0 PLUMBING DISTRIBUTION PANEL (MDB 1.3)
100 amps 4P MCCB with the following accessories:
a. 0-500 volts 96 x 96 mm square ammeter with selector switch shall be protected by 2
amps TP MCB-1 Set
b. 0-100 amps 96 x 96 mm square voltmeter with selector switch and 100/5 amps 10 VA
c. Phase indicating lamps shall be protected by 2 amp SP MCB-3 Sets
150 amps TPN (25 KA) Aluminium bus bar with heat shrinkable insulation sleeves colour
a. 2 Nos. suitable rating MPCB for 2.2 kW each STAR DELTA starter and outgoing
feeder to DOMESTIC Water transfer pumps motor - Main (including 1nos. standby).
Each compartment shall contain auto / manual selector swtich and indicating /
pushbutton lamps with MCB for ON / OFF / TRIP of motor.
b. 2 Nos. suitable rating MPCB for 1.0 kW each direct on line starter and outgoing
feeder to Plumbing Plant Room Sump Pump (including 1 no. standby). Each
compartment shall contain auto/manual selector switch and indicating lamps with MCB‟s
for „ON/OFF/TRIP' status of motor
c. 2 Nos. suitable rating MPCB for Nos. 2.2 kW each direct on line starter and outgoing
feeders to Raw Water Feed pump (including 1 no. standby). Each compartment shall
contain auto/manual selector switch and indicating lamps with MCB for „ON/OFF/TRIP‟
status of motor
Item Description Unit Qty. Rate Amount
All MCCB's to be suitable for motor duty and shall be of 25 KA breaking capacity.
Provision shall be made for providing potential free contacts to all pumps starters for
connection to building automation system.
All motor starter shall be provided with Automatic level controller.
Overflow alarm must be provided at the plant room
Electrical panel must have the Auto announciator to indicate the system failure if any
Plumbing DistributionPanel (MDB 1.4) as described above Set 1.00 76185.20 76185.20
7.0 CAPACITOR BANKS WITH DETUNED FILTER IN AUTOMATIC CONTROL UNITS -
AS PER IEC 61439 DESIGN VERIFIED
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning
of Automatic control panels with low loss mixed dielectric /APP/MPP type capacitors,
fabricated out of 14 gauge CRCA sheet steel in cubicle compartmentised, free
standing, floor mounted, dust and vermin proof with reinforcement of suitable size,
angle iron, channel, „T‟ sections and / or flats wherever necessary. Cable gland plates
shall be provided on top as well as at the bottom of the panels. Panels shall be treated
with all anticorrosive process before powder coating as per specifications and final
approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution
panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting
hooks shall also be provided in case of large panels. Approval shall be taken for each
panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc
passivation shall be used in fabrication of panels.
It shall provide rated 150KVAR . The panel shall also comply with following :
400 Amps TP MCCB incomer with 50KA breaking capacity to be provided :
500 Amps TPN aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set
i. 125 amps TPN MCCB - 1 Set
ii. 100 amps TPN MCCB - 2 Set
iii. 32 amps TPN MCCB - 3 Set
iv. “ON” /”OFF” push buttons and indicating lamps. - 7 Set.
v. 50 kVAR Capacitors,480V with 7% detuned filters- 1 Set.
vi. 25 kVAR Capacitors, 480V with 7% detuned filters- 2Set.
vii. 10 kVAR Capacitors, 480V detuned filters- 2 Set.
viii. 5 kVAR Capacitors, 480V without detuned filters- 1 Set.
Microprocessor APFC controller shall continuously monitor all three phases and displays
various Electrical Parameters like voltage, input current, capacitive current, KVA
demand,KW, Power Factor, self diagnostic error code indication with printout facility of
the above with RS 232C port. Controller should mounted on the front side of the panel.
It shall have data logging for minimum 2 months, it shall provide thyristor output for
maximum 16 stages.
Fast response time of „ON‟ capacitors 20-60 miliseconds.
Super fast electronic fuse and links of the proper rating to be used for grouping the
capacitor banks. Capacitor shall be connected with fast discharge resistances.
Thyristor having suitable capacity to carry expected current continuosly.
Necessary control and firing card with proper wiring and lugs of the required rating to be
Heavy duty exhaust fans to be provided for cooling Thyristors.
Item Description Unit Qty. Rate Amount
LED indication for number of capacitor banks „ON‟.
LED indication of Power Factor lagging or leading.
Auto/manual selector switch with necessary wiring to operate APFC panel in manual
mode bypassing APFC relay.
The APFC system shall be provided with following :
a. Over voltage.
b. Voltage imbalance.
c. Over temperature-system should be in standby mode and automatically restart after
above condition restored.
d. Total Harmonic Distortion
7% of series reactor having linearity as (2.08). €In with L=0.95Ln
Capacitor Units shall have 480 V and rating shall be suitably increased considering
reactors into account.
Capacitor automatic control panel (125 kVAR)
as described above. Set 2.00 607292.00 1,214,584.00
8.0 FINAL DISTRIBUTION BOARDS
Supply, installation, testing and commissioning of the following DB's fabricated out of 1.6
mm thick CRCA sheet steel in cubicle compartmentalized, dust and vermin proof, double
door construction, powder coated with approved shade and partitions to segregate
phases. Approved lockable covers with padlocking arrangement, recessed in wall or
surface mounted final distribution boards of the following description:
4+6+12(36) way TPN DB (PPI), 36 No.10/ 16/ 20 Amps SP MCB‟s as outgoing with 3 Nos. 2.00 28,336.00 56,672.00
No. 40 Amps DP ELCB‟s of 30 mA leakage current and 1 No. 63 Amps 4 pole MCB as
incomer with separate neutral link for each phase.
4+6+8(24) way TPN DB, 24 No.10/ 16/ 20 Amps SP MCB‟s as outgoing with 3 No. 40 Nos. 4.00 22,540.00 90,160.00
Amps DP ELCB‟s of 30 mA leakage current and 1 No. 63 Amps 4 pole MCB as
incomer with separate neutral link for each phase.
4+6+4(12) way TPN DB, 12 No.10/ 16/ 20 Amps SP MCB‟s as outgoing with 3 No. 40 Nos. 4.00 19,320.00 77,280.00
Amps DP ELCB‟s of 30 mA leakage current and 1 No. 63 Amps 4 pole MCB as
incomer with separate neutral link for each phase.
2+12 way SPN DB, 12 No.10/ 16/ 20 Amps 'D' curve SP MCB‟s as outgoing with 1 No. Nos. 6.00 9660.00 57,960.00
25 Amps DP ELCB + MCB as incomer with separate neutral link for each phase.
9.0 Supply, installation, testing and commissioning of 100 amps 4 Pole MCB isolator with in Nos. 2.00 6311.20 12,622.40
sheet steel enclosure of approved make design and painted with approved paint shade.
Item Description Unit Qty. Rate Amount
10.0 Supply, installation, testing and commissioning of 63 amps 4 Pole MCB isolator with in Nos. 4.00 4765.60 19,062.40
sheet steel enclosure of approved make design and painted with approved paint shade.
11.0 Supply, installation, testing and commissioning of 40 amps 4 Pole MCB isolator with in Nos. 2.00 3297.28 6,594.56
sheet steel enclosure of approved make design and painted with approved paint shade.
12.0 Supply, installation, testing and commissioning of 16 amps 4 Pole Metal clad socket with Nos. 2.00 4121.60 8,243.20
MCB protection in Polycarbonate enclosure of approved make design and painted with
approved paint shade. (AC indoor units)
TOTAL CARRIED TO SUMMARY 5288231.76
1.0 Supply, installation, Testing and commissioning of the following UPS SYSTEM as per
specifications and complete in all respects.
1.1 30 KVA modular type UPS with 30 min battery backup of 3 phase input & 3 phase SET 1.00 1228752.00 1,228,752.00
2.0 2.5 kVA stand alone UPS with 30 min. battery backup of 1 phase input & 1 phase output. SET 2.00 122875.20 245,750.40
3.0 Site Acceptance Test (SAT) at full load on site complete with load bank, cabling, tools LOT 1.00 56834.09 56,834.09
and tackles etc.
4.0 Supply and fixing in position 1000 mm wide rubber matting of 1100 volts grade as per RM 10.00 3196.91 31,969.06
electricity rules (exact length rubber mats to be worked out as per site requirement).
Thickness of rubber mats shall be not less than 6 mm.
5.0 Providing and fixing steel structure work for supporting the above 3 sets of UPS & LOT 1.00 88803.27 88,803.27
battery cabinets.
TOTAL CARRIED TO SUMMARY 1652108.83
ELECTRICAL SUMMARY
Item Description Amount
A. CIRCUIT CUM POINT WIRING (IN RECESSED / SURFACE PVC/ MS CONDUITS) ` 311639.05
B. CABLES, MAINS AND SUB MAINS ` 5451758.76
C. CABLE TRAYS AND RACEWAYS: ` 3340870.68
E. LIGHTNING PROTECTION SYSTEM ` 2128128.45
F SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIGHTING ` 4089491.80
FIXTURES AND ACCESSORIES
G. SUPPLY, INSTALLATION OF LIGHTING FIXTURES AND SUPPLY & ` 1340287.20
INSTALLATION OF CABLES FOR EXTERNAL/ LANDSCAPE LIGHTING
H. MAIN LT PANEL, UTILITY PANELS AND DBs ` 5288231.76
I. UPS SYSTEM ` 1652108.83
GRAND TOTAL ` 23602516.52
GRAND TOTAL ` 23602516.52
ELECTRICAL HV INSTALLATION WORK (NON-SCHEDULED ITEM)
SL. DESCRIPTION OF ITEMS UNIT QTY Rate Amount (Rs.)
PART-1: HV INSTALLATION
PART-1: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF SUB-
STATION EQUIPMENT
1 11kV MAIN H.T.PANEL
Supply, installation, testing and commissioning of factory assembled, 11kV,
350MVA, 3phase, 50Hz. fully insulated, indoor type, main HT Panel consisting of
11kV, 17.5 kA symmetrical for 3 sec. as per following specifications and as per
general specifications and technical specification as required complete. The
panel shall be IP4X protection. The configuration of the breaker shall be one (1)
incomer cum outgoing feeder. Power pack of 2.5 kVA with all accessories
complete as required shall be provided inside the panel. The rate shall include all
civil works such as foundation pad, grouting etc.
A. One(1) incoming feeder shall have the following features:
a. HT Breaker Type-
Indoor switchgear with fully interlocked, electrically operated draw out type, trip
free,VCB motor operated spring charged stored energy mechanism circuit
breaker with electrical releases, antipumping relay, complete with instruments,
relays and all associated auxiliaries, and with pad lockable automatic safety
shutters for power disconnect spouts, earth switch with suitable interlock with test
terminal block etc. Closing coil, shunt trip coils and indication ckt shall be suitable
b. Rated continuous current- 630A
c. Rated operational/ insulation voltage- 11/ 12kV
d. Short Circuit interrupting rating-350MVA
c. Rated short circuit level- 21.0 kA symmetrical for three (3) seconds.
d. Rated breaking current- 21.0 kA symmetrical
e. Power frequency withstand voltage - 28 kVp for 1 minute
f. Impulse withstand voltage- 75 kV at 1.2 x 50 microsecond wave crest.
g. Vacuum Bottle short time capacity-26.3 kA
h. Service Life (Designed)- 100 operations at short circuit
i. Electrical/ Mechanical closing / Tripping
j. Anti-pumping relay
k. Trip circuit supervision relay
l. Over current and earth fault self powered IDMT relay with instantaneous high set
element range 50 – 200% for outer poles and 20-80% for middle pole.
m. 110 V DC spring charging motor.
n. Indication for ON/ OFF/ SPRING CHARGED
o. Suitable number of NO/ NC contacts
p. 230V, 50Hz. Space heaters with fuse and ON/OFF toggle switch
q. 3 Nos. Cast resin CTs of dual ratio 60 - 30 / 5-5 Amps CL:1, 5P10, 15 VA.
r. 3 Nos. Cast resin drawout type PTs 11 kV / √3 / 110 √3, class 1, 100 VA
s. Cable termination space to be suitable for 1R (3C x 185) Sq.mm. 11kV armoured
XLPE cable, complete with cable sealing kit, push on type
B. Two (2) Outgoing feeder shall have the following features:
a. HT Breaker Type-
Indoor switchgear with fully interlocked, electrically operated draw out type, trip
free,VCB motor operated spring charged stored energy mechanism circuit
breaker with electrical releases, antipumping relay, complete with instruments,
relays and all associated auxiliaries, and with pad lockable automatic safety
shutters for power disconnect spouts, earth switch with suitable interlock with test
terminal block etc. Closing coil, shunt trip coils and indication ckt shall be suitable
b. Rated continuous current- 630A
c. Rated operational/ insulation voltage- 11/ 12kV
d. Short Circuit interrupting rating-350 MVA
c. Rated short circuit level- 21.0 kA symmetrical for three (3) seconds.
d. Rated breaking current- 21.0 kA symmetrical
e. Power frequency withstand voltage-28 kVp for 1 minute
f. Impulse withstand voltage- 75 kV at 1.2 x 50 microsecond wave crest.
g. Vacuum Bottle short time capacity-26.3 kA
h. Service Life (Designed)- 100 operations at short circuit
SL. DESCRIPTION OF ITEMS UNIT QTY Rate Amount (Rs.)
i. Electrical/ Mechanical closing / Tripping
j. Anti-pumping relay
k. Trip circuit supervision relay
l. Over current and earth fault self powered IDMT relay with instantaneous high set
element range 50 – 200% for outer poles and 20-80% for middle pole.
m. 110 V DC spring charging motor.
n. Indication for ON/OFF/SPRING CHARGED
o. Suitable number of NO/ NC contacts
p. 230V, 50Hz. Space heaters with fuse and ON /OFF toggle switch
q. 3 Nos. Cast resin CTs of dual ratio 40 - 20 / 5-5 Amps CL:1, 5P10, 15 VA.
r. 3 Nos. Cast resin drawout type PTs 11 kV / √3 / 110 √3, class 1, 100 VA
s. Cable termination space to be suitable for 1R (3C x 185) Sq.mm. 11kV armoured
XLPE cable, complete with cable sealing kit, push on type
All CTs & PTs in the incoming and outgoing shall be verified, approved and
calibrated as per the requirement of State Electricity Board.
HT Panel as described above SET 1 1823808.00 1823808.00
2 11kV DRY TYPE TRANSFORMER
1.1 Design, fabrication, assembling, wiring, supply, testing at works, packaging,
forwarding to site and supervising the testing & commissioning of 400 kVA, 3
phase, 11/ 0.433 kV Cast Resin indoor Dry type IP 33/34 Transformer copper
wound with Dyn 11 connection and neutral brought out for earthing as per
following specification and as per general and technical specification as required
complete. The transformer shall be provided with (–) 15% and (+) 5% On load tap
changer on HT side, remote tap changing circuit and inbuilt automatic voltage
regulator. HT side cable termination box shall be suitable for 11 kV, 3 C x 185 sq.
mm XLPE cable and LT side terminal box shall be suitable for termination of
suitable size AL cable. The transformer shall be supplied with all standard fitting
viz thermistors for Alarm and Trip, winding temperature relay unit with Alarm and
trip, lifting lugs, earthing studs and marshlling box, etc. complete in all respect as
required as per specification.
The transformer shall have the following specification:
a Rating: 11/ 0.433kV
b kVA rating: 400kVA
c Percentage impedance: 5.0% (+/-5%)
d Rated Primary system Voltage: 11 kV, 3 phase
e Rated Secondary system voltage (Center tap): 0.433 kV
f Highest Primary system Voltage: 13 kV, 3 phase
g Rated Secondary system voltage (Center tap): 0.459 kV
h Frequency: 50 Hz.
i Vector grouping: Dyn 11
j Cooling: AN cooled
k HT system fault level: 350 MVA(assumed)
l System Neutral Earthing for HV System: Non effectively Earthed
m System Neutral Earthing for LV System: effectively Earthed
n Impulse withstand voltage: For 11 kV: 75 kV
o Power frequency withstand voltage: 28kV
p Tap changing option: On load tap changer on HV side
q Tap changing range: +5% to -15% in steps of 1.25% each
r Transformer terminal box:
i. HV- Cable termination box to be suitable for 1R (3Cx185) Sqmm 11kV
armoured XLPE cable.
ii. LV- Cable termination box to be suitable for appropriate size 1.1kV armoured
400 kVA dry type transformer with OLTC (On Load Tap Changer) as described SET 2 2158172.80 4316345.60
1.2 The transformers as described in item no. 1.1 above shall be provided with
automatic on load tap changer panel suitable for remote operation to change the
transformer tapping in automatic and manual mode as per following specification
and as per general and technical specification as required complete. Automatic
voltage regulating relay to be provided with digital type tap position indicator for
auto operation. The panel shall be IP 54 free standing, floor mounted type. The
control circuit shall be suitable for master-slave operation for working in auto
The RTCC panel shall have the following :
a Digital tap position indicator
b Upper and lower limit indicator
c 433V/110V PT for LV sensing for AVR
SL. DESCRIPTION OF ITEMS UNIT QTY Rate Amount (Rs.)
d 0-500V Digital Voltmeter with selector switch
e 230V, 50Hz. Space heaters with fuse and ON/OFF toggle switch
f Rectfier for DC supply
g Tap changer isolation switch
h Tap changer in progress lamp
i Auto/ manual selector switch
RTCC Panel for 11 kV dry type transformer with OLTC as described above SET 2 182380.80 364761.60
3 Supply and fixing in position the approved “Shock Treatment Charts” written in No. 6 5319.81 31918.86
English and Local Language. These charts shall be framed in teak wood frame
and covered with glass.
4 Supply and fixing in position the fire extinguishers carbon-di-oxide type 4.5 Kgs No. 12 5026.60 60319.26
5 Supply and fixing of in position the fire extinguishers dry chemical power (ABC) 5 No. 12 5361.71 64340.51
6 Supply and fixing of in-position the fire extinguishers dry chemical power (ABC) 2 No. 12 3351.06 40212.75
7 Supply and fixing in position the best quality Danger Boards of approved shape No. 18 2136.30 38453.39
and size as specified by Local Electricity Authorities written in English & Local
8 Supplying of fixing in position 1.8 m length 0.9 m wide & of sufficient thickness, SET 4 4835.59 19342.36
Electrical grade Rubber mats of approved make and as per Electrical rule.
9 Supply of fire buckets 5 No. in each set duly filled with fine sand and fixed on an SET 3 14828.48 44485.43
angle iron frame as per requirement of local authorities. Fire buckets shall be
painted red from outside and white from inside with additional handle at the
bottom and suitable for outdoor installation.
10 Supply and fixing position the approved single line diagram framed in 1000 x 800 No. 6 837.77 5026.63
mm size glass frame and installed in main switch room.
11 Supply of First Aid box of approved make as per specification. No. 3 3351.06 10053.19
12 Supply of tool kit with 1 pair 11 KV rubber hand gloves of approved make. Set 2 3351.06 6702.12
Rate/ amount should include the following
The professional charges for liason work and departmental procedures required
for the above said work .
The work shall include the following:
a. Complete liasoning with Supply Company and electrical inspectorate.
b. Obtaining the feasibility report and spot inspection, etc.
c. Obtaining sanction of H.T. connection of 1000 KVA Transformer.
d. Preparation and submission of all statutory drawings to Supply Company and
electrical inspectorate.
e. Obtaining necessary approvals and submitting to the clients.
f. Arranging for the service from the Supply Company.
g. Any other works related to Supply Company and Electrical inspectorate.
TOTAL CARRIED TO SUMMARY 6825769.68
PART-2: HV CABLES
1 Supplying and laying following size 11 kV grade XLPE (E) aluminium conductor
armoured cables laid over MS supports in existing trenches.
a. 3 C x 185 sq.mm 11 kV XLPE (E) cable RM 80 2050.85 164,068.26
2 Supplying and making cable end terminations for the following size of 11 kV
grade, XLPE (E) aluminium conductor armoured cable including termination kit
complete heat shrinkable sleeve etc.
a. 3 C x 185 sq.mm 11 kV XLPE (E) cable No. 6 2891.97 17,351.83
3 Supplying, laying GI sleeves of following sizes:
SL. DESCRIPTION OF ITEMS UNIT QTY Rate Amount (Rs.)
4 Supplying and laying of following 1100 volts grade PVC insulated sheathed
copper conductor armoured control cables in existing trenches cables trays,
clamped on wall with suitable saddles, fixing bolts, including testing and
a. 7 Core 2.5 sq mm PVC insulated copper conductor armoured control cables RM 50 663.51 33,175.52
5 Cable end termination of the following PVC insulated sheathed aluminium
conductor armoured cables of 1100 volt grade including supplying and fixing of
crimping lugs. Double compression glands, cable sockets etc as required.
a. 7 Core 2.5 sq.mm Control cable No. 6 418.88 2,513.28
TOTAL CARRIED TO SUMMARY 248022.60
TOTAL (PART 1 + 2) 7073792.28
AC SYSTEM (HVAC WORKS)
SL.NO DESCRIPTION UNIT TOTAL RATE AMOUNT
NON SCHEDULE ITEMS
A. Supply of Split type AC Uint with Filter Clean Indicator, Super fine
Mesh Filter, Stepless Compressor Control, Penta sensor, 100%
Cooling capacity at 43°C
1TR 3 Star Inverter
Tropical Rotary Compressor, 230 V, 425 CFM Air Flow 4 38,768.80 155,075.20
1.5TR 3 Star Inverter
Tropical Rotary Compressor, 230 V, 530 CFM Air Flow 4 44,551.92 178,207.68
2.0 TR 3 Star Inverter
Tropical Twin Rotary Compressor, 230 V, 620 CFM Air Flow 16 57,290.24 916,643.84
4 Installation and Commissioning charge for Split AC Nos. 24 2,992.02 71,808.58
7 Copper Cable Rmt 288 200.93 57,867.26
Supply and installation of Readymade Angels and Brackets with
corrosion resistance paint 1,114.12 26,738.88
FIRE MANAGEMENT SYSTEM
Sl. No. Description Unit Quantity Rate Amount
(NON SCHEDULE ITEMS)
A FIRE DETECTION AND ALARM SYSTEM
FIRE DETECTION AND ALARM SYSTEM - ANALOG ADDRESSABLE SYSTEM
1 MANUAL CALL POINT
Supply, installing, testing & commissioning of addressable Manual
call point (Pull station-double action).
2 FAULT ISOLATOR
Supply, installing, testing and commissioning of addressable type
Fault Isolators for isolating shorted, de wired and loose circuits
between two successive fault isolators with automatic resetting
3 RELAY CONTROL MODULES
Supply, installing, testing and commissioning of addressable and
automatic commandable Relay control modules.
4 CONTROL MODULES
Supply, installing, testing and commissioning of addressable and
automatic commandable control modules.
5 MONITOR MODULES
Supply, Installation, testing and commissioning of Addressable
Monitor modules.
6 RESPONSE INDICATOR
Supply, installation, fixing, testing and commissioning of Response
Indicator cum lamp assembly mounted on walls/ partitions, surface/
recessed etc. in dust tight enclosure, including chase cutting
complete as required.
7 STROBES CUM HOOTERS
Supply, installation, testing and commissioning of Strobes cum Dual
tone hooters with minimum of 110cd and 93 db complete as Nos. 8.00 3198.10 25584.83
8 FIRE ALARM CONTROL PANEL
Supply, installting, testing and commissioning of Microprocessor
based intelligent and electronically addressable, modular,
expandable, networkable, loops as given below (each loop consist of
159 detector & 159 devices or as per the approved OEM) Fire Alarm
Control Panel with minimum 6 inch/ 640 character LCD display,
multiple access levels, event history file in non-volatile memory
(EEPROM). The panel shall support programmable relays controlled Nos. 1.00 638903.38 638903.38
by powerful Boolean logic equation. The panel shall have 240 volts
AC power supply, automatic battery charger, 24 volts, sealed lead
acid maintenance free batteries sufficient for 24 hours normal
working and then be capable of operating the system for 60 minutes
during emergency condition. The panel shall be UL listed 9th Edition
(With Networking Card Compatible to Fiber Optic Cable)
2 Loop Fire alarm control panel
Sl. No. Description Unit Quantity Rate Amount
9 WIRES IN CONDUITS:
Supply & laying of, 2x1.5 sq.mm 450/ 750V grade FR-LSH PVC
insulated, un-sheathed copper conductor wire including
a. terminations, connections & all labour and material etc.complete as Meter 350.00 57.96 20286.00
required (For fire detection signal, for fire loop, for speakers, for tele
Providing and fixing in position of MS conduit including bends,
junction boxes, pull boxes, GI pull wire including necessary civil work
c. such as chase cutting, chipping, making good for recessed conduiting
or clamping on surface with saddles, clamps etc. for surface
B. FIRE FIGHTING SYSTEM
1 Providing, laying, testing & commissioning of 'C' class heavy duty MS
pipe conforming to IS 3589/IS 1239 including Welding, fittings like
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the
pipe on the wall/ceiling with suitable clamp/support frame and
painting with two or more coats of synthetic enamel paint of required
shade complete as required :
2 Providing, installation, testing and commissioning of non-return valve
of following sizes confirming to IS: 5312 complete with rubber gasket,
GI bolts, nuts, washers etc.as required :
3 Supplying, fixing, testing and commissioning of butterfly valve of PN
1.6 rating with bronze/gunmetal seat duly ISI marked complete with
nuts, bolts, washers, gaskets conforming to IS 13095 of following
sizes as required :
4 Providing, installation, testing and commissioning of stainless steel Y-
strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,
sheet with 3 mm dia holes with stainless steel flange.
5 Supplying and fixing first-aid Hose Reel with MS construction spray
painted in post office red, conforming to IS 884 complete with the
following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve &
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal
valve & M.S. Pipe and socket.
Sl. No. Description Unit Quantity Rate Amount
6 Supplying, installation, testing and commissioning of electric driven
terrace pump suitable for automatic operation and consisting of
following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast
iron body & bronze impeller with stainless steel shaft, mechanical
confirming to IS : 1520
b) Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of
protection for enclosure, horiziontal foot mounted type with Class-'F'
insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard,
foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti
vibration pads.
7 Providing & fixing of pressure switch in M.S. pipe line including
connection etc. as required. 4 6,755.82
8 Providing & fixing swinging type hose reel drum fabricated from 14
SWG CRCA sheets painted with red color stove paint 2 coats over 1
coat of primer with 30 m long 20 mm dia rubber hose pipe with 10kg /
sqcm working pressure with GM shut – off nozzle of 5 mm outlet
fixed on wall with dash fasteners, 25 mm dia valve etc.as required
9 Providing and Fixing M.S. hose box with lockable arrangements to
accommodate 2 RRL hose of 15 m length and one branch pipe
painted white inside and red outside with one key.
Capacity 4.5 kg. ISI marked Each 20 8561.34 171,226.72
10 Providing and fixing mechanical foam type ( ISI marked ) fire
extinguisher consisting of welded MS cylindrical body, squeeze, lever
discharge valve, high pressure discharge hose, discharge nozzle,
suspension bracket ISI marked finished externally with red enamel
paint and fixed to wall with brackets with internal charger .
Capacity 9 liters Each 20 3399.35 67,987.08
11 Providing & fixing water Co2 ( ISI marked ) extinguisher including all
accessories with wall bracket with rawl plug.
Capacity 9 liters. Each 10 3155.60 31,556.00
12 Providing & fixing dry powder extinguisher consisting of welded MS
cylindrical body, with discharge valve, nozzle and CO2 cartige and
hanging arrangement complete
Capacity 5 kg. ISI marked Each 10 3735.20 37,352.00
DESIGN, drawing and SITC OF SIGNAGE
NO. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
(NON SCHEDULE ITEMS)
1 Sign Typology for EXTERNAL SIGNAGE
1.1 TS - Totem Signs at Main entry Gate (18'6" x 4'6") 1 Nos. 360640.00 360640.00
Providing, Fixing & Preparing Graphics and Artworks for Tri-lingual Single Sided
Totem Sign of size 18'-6" x 4'-6" at gates. The existing structure between the two
column shall be modified as per design i.e. brick wall raised by 4'-6" and shall be
clad in 20mm thk. black granite. All graphics etched and coulour-filled as per
approved artworks, with transportation and installation at site complete.
Providing, Fixing & Preparing Graphics and Artworks for Single Sided Bilingual Site
Map of size 3' x 7', fabricated as per approved drawing, using 304 grade SS
channels, 3" x 2" x 2mm thk., of size 35" width x 8'-6" height, embedded 18" verticaly
into ground with proper foundation in cement concrete in 1:2:4, with sign panels in
20mm thick Black Granite, (with approved artworks and graphics etched and color
filled) bolted over SS framework with necessary hardware and tools required for
proper fixing for the same in position, with transportation and installation at site
2 Sign Typology for INTERNAL SIGNAGE
2.1 DF - Fixed Door Signs (16" x 8") 15 Nos. 5987.52 89812.80
Providing, Fixing & Preparing Graphics & Artworks for Trilingual ID-2 Signs of size
14" x 6", in 5mm thk. Clear Acrylic, laser cut to appropriate size and shape, with all
graphics 'flat-bed' printed directly onto acrylic surface in reverse as per approved
artworks, fixed to existing surface using studs/spacers/ brackets or 3M double sided
tapes whichever appropriate as per site conditions, using necessary hardware and
tools, with transportation and installation at site complete.
eg. Seminar room, Museum, Cafeteria, office Room, Lift No. & name, Library,
Electrical Room, AHU etc.
2.2 WF - Wayfinding Signs (48" x 12") 12 Nos. 27167.84 326014.08
Providing, Fixing & Preparing Graphics & Artworks for tri-lingual Suspended
Directional Signs of size 48" x 12", in 5mm thk. Clear Acrylic, laser cut to appropriate
size and shape, with all graphics 'flat-bed' printed directly onto acrylic surface in
reverse as per approved artworks, fixed to existing surface using studs/ spacers/
brackets/ suspension mechanisms or 3M double sided tapes whichever appropriate
as per site conditions, using necessary hardware and tools, with transportation and
installation at site complete.
Mostly in Corridors
TOTAL FOR SIGNAGE 1245298.88
SITC OF EQUIPMENT
Description Unit Quantity Rate Amount
Equipment (COCOON TO YARN)
Solar Unnati Tasar (4 spindle) Machine &
Solar Unnati Tasar (2 spindle) Machine &
3.0 Re-reeling charkha 8 ends & installation Nos. 10.00 48737.92 487379.20
4.0 Spinning / Deflossing (pedal) & installation Nos. 10.00 12570.88 125708.80
5.0 Bobbin winding (32 spindle) & installation Nos. 2.00 146574.40 293148.80
6.0 Twisting (80 Spindle) & installation Nos. 1.00 273056.00 273056.00
7.0 Re-reeling + twisting (20 spindle) & installation Nos. 2.00 144771.20 289542.40
8.0 Cone making machine & installation Nos. 1.00 1003352.00 1003352.00
9.0 Book machine (yarn) & installation Nos. 10.00 6780.03 67800.32
10.0 Boiler & installation Nos. 1.00 407008.00 407008.00
Hot Chamber with Conveyor system 2T
Equipment Post Yarn (YARN TO WEAVING)
Sun Kharga- Solar operated Loom with
Installation, Testing and commissioning
Handlooms with accessories with
Installation, Testing and commissioning
15.0 Dobby attachment & installation Nos. 1.00 13833.12 13833.12
16.0 Jacquara (400 Hooks) & installation Nos. 1.00 58990.40 58990.40
17.0 Warping machine & installation Nos. 2.00 276662.40 553324.80
Digital Printing machine & Accessories with
Installation, Testing and commissioning
Padding process with Installation, Testing and
Description Unit Quantity Rate Amount
Steamer with Installation, Testing and
Industrial washing machine with Installation,
Testing and commissioning
Rinsing machine with Installation, Testing and
Drying machine with Installation, Testing and
Ironing machine with Installation, Testing and
Other Equipment
26.0 Desktop Computer (all in one type)
9th Generation Intel® Core™ i7 processor
Windows 10 Pro 64
16 GB DDR4-2666 SDRAM (1 X 16 GB)
1 TB PCIe® NVMe™ SSD
Intel® UHD Graphics 630
Min screen size 60. 45 cm
Note: Cost for all Items are inclusive of 5 years AMC (including defect liability period) with spare and Labour,
imparting necessary training to Owner's personnel and supply of opearational manuals in triplicate from
SUPPLY AND INSTALLATION OF FURNITURE WORKS
SNO. PARTICULARS QTY UNIT RATE AMOUNT
HOSTEL CUM GUEST HOUSE
SINGLE BED 7' x 3' in 18/19 mm THICK CALIBRATED BWP PLY & 0.8 mm LAMINATE,
1 SIDE TABLE SIZE 500 w 400 d 450 h & WARDROBE 18/19 mm THICK CALIBRATED BWP 4 SET 83720.00 334880.00
PLY & 0.8 mm LAMINATE OF SIZE 800 w 600 d 2100 h
MEDIUM BACK CHAIRS REVOLVING AND TILTING WORKING POSITION LOCK HYDRALIC
2 GASLIFT , 5 PRONGED NYLON BASE NON SAGGED PU FOAM UPHOSTERED PLY SEAT 4 PCS 6440.00 25760.00
ERGONOMIC MESH BACK REST IN POWDER COATED METAL FRAME .
WROUGHT IRON DOUBLE DECK BED MADE OF 50 mm x 50 mm ,50 mm x 25 mm 19mm (
ROUND ) & 25m X 35mm CRCA MS 1.6mm PIPE .60 MICRON POWDER COATING BED
3 SIZE H 1950 mm W 900 mm L 1950mm HEAD SIDE & LEG SIDE GROUND OF THE BED 300 40 PCS 45080.00 1803200.00
mm HEIGHT BETWEEN 2 COTS 1050 mm STAIR WIDTH 300 mm WITH BONDED FOAM
METAL POWDER COATED STORAGE 2 DRAWER SIZE 300mm x 450 mm x 600 mm 18
4 GUAGE CRCA MS SHEET EPOXY POLYSTER 50 MICRONS POWDER COATED
DINING HALL – 6 SEATER TABLE SIZE 5' x 2'6" IN MS FRAME 60 MICRON POWDER
COATING AND WOODEN TOP WITH ABS CAFE CHAIRS
CRECHE - 4 MESH WORK CHAIRS REVOLVING AND TILTING WITH 3 SEATER LEATHERITE
COMMON ROOM - 2 SINGLE LEATHERITE SEATER SOFA WITH 1 No GLASS CENTRE
7 TABLE 3' X 2'
5 Pcs REVOLVING AND TILTING MESH CHAIRS & ARROW BASE GLASS TOP TABLE 1.5 M
MEDIUM BACK CHAIRS REVOLVING AND TILTING WORKING POSITION LOCK HYDRALIC
9 GASLIFT , 5 PRONGED NYLON BASE NON SAGGED PU FOAM UPHOSTERED PLY SEAT 12 PCS 6440.00 77280.00
ERGONOMIC MESH BACK REST IN POWDER COATED METAL FRAME .
WORK DESK IN 25 MM THICK PRE LAMINATED PARTICLE BOARD 17 MM MODESTY 4' X
10 2' TOP WITH 3 DRAWERS 400 MM W X 450 D 680 H 3 PCS 19320.00 57960.00
DESIGN AND TRAINING CENTRE
RECEPTION - 2 +1+1 SEATER SOFA IN WOODEN FRAME WITH BELTS AND FOAM PU
11 LEATHERITE UPHOLSTERED AND WOODEN TEAK WOOD CENTRE TABLE AS PER 2 SET 103040.00 206080.00
CAFETERIA – 6 SEATER TABLE 6' x 3' IN MAHOGANY WOODEN FRAME 18 mm PLY
CALIBRATED BWP PLY AND 5mm THICK VENEER TOP WITH MAHOGANY WOOD
12 DINNING CHAIRS UPHOLSTRY IN 40 DENSITY FOAM IN SEAT 28 DENSITY IN BACK & 5 SET 103040.00 515200.00
MEETING ROOM – 5 Pcs REVOLVING AND TILTING MESH CHAIRS & CHROME FINISH
13 ARROW BASE 1.5M DIA 8 mm THICK GLASS TOP TABLE 1 SET 39928.00 39928.00
MEDIUM BACK CHAIRS REVOLVING AND TILTING WORKING POSITION LOCK HYDRALIC
14 GASLIFT , 5 PRONGED NYLON BASE NON SAGGED PU FOAM UPHOSTERED PLY SEAT 12 PCS 6440.00 77280.00
ERGONOMIC MESH BACK REST IN POWDER COATED METAL FRAME .
OFFICE - WORK DESK IN 25 MM THICK PRE LAMINATED PARTICLE BOARD 17 MM
15 MODESTY 4' X 2' TOP WITH 3 DRAWERS 400 MM W X 450 D 680 H 3 PCS 19320.00 57960.00
TRAINING ROOM – 10 Pcs REVOLVING AND TILTING MESH CHAIRS & ARROW BASE
16 GLASS TOP TABLE 4.0 M X 2.0M 1 SET 39928.00 39928.00
MEETING ROOM – 5 Pcs REVOLVING AND TILTING MESH CHAIRS & CHROME FINISH
17 ARROW BASE, 8 mm THICK GLASS TOP TABLE SIZE 6' X 6' 1 SET 39928.00 39928.00
LABOUR REST ROOM - 2 +1+1 SEATER SOFA IN WOODEN FRAME WITH BELTS AND
18 FOAM PU LEATHERITE UPHOLSTERED AND WOODEN TEAK WOOD CENTRE TABLE AS 1 SET 103040.00 103040.00
NOTE: SHOP DRAWINGS FOR ALL FURNITURE PREPARED BY MANUFACTURER (AS PER LIST OF APPROVED
MAKES) TO BE SUBMITTED FOR APPROVAL OF EMPLOYER. COLOUR / SHADE OPTIONS WILL BE AS PER
CHOICE OF EMPLOYER.
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Notice Inviting Tender-Tasar.pdf
Tender Document
CS_cover_2_BOQ008NBCCBBSR2021-TASAR.xlsx
Tender Document
GCC Contracting 2019 with Amendment 1to5.pdf
Tender Document
Approved Makelist-TASAR.pdf
Tender Document
Drawings_compressed.pdf
Tender Document
Special Conditions of Contract-Tasar.pdf
Tender Document
07-Technical Specifications.pdf
Tender Document
08-Annexure-I A-Physical Milestone.pdf
Tender Document
09-Integrity Pact-Tasar.pdf
Tender Document
10-Instruction to Bidder.pdf
Tender Document
BOQ-TASAR-REV-merged.pdf
Tender Document
corrigendum-102-OpeningofPrice BidNIT008.pdf
pdf • 0.06 MB
addendum-d0f9de43b881-Corrigendum-Addendum02-NIT-008.pdf
pdf • 0.17 MB
addendum-05e477d97727-Corrigendum-Addendum01-NIT-008.pdf
pdf • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .