Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.6 LAccepted-AOC 203 B CHAHBAI BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹1.1 Cr+₹12.9 L (13.5%)Rejected-Finance H NO 769 SOUTH CIVIL LINES MUZAFFAR NAGAR UP | MUZAFFARNAGAR | MUZAFFARNAGAR | UTTAR PRADESH | 251001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹1.2 Cr+₹20.2 L (21.2%)Rejected-Finance A 31 RAJENDRA NAGAR BAREILLY UP 243122 | BAREILLY | BAREILLY | UP | 243122 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹1.2 Cr+₹26.1 L (27.4%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L4 | Rejected-Finance Not Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
30 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
HQ CWE (AF) Bareilly-243002
WORK SERVICES FOR WIDENING OF PTT AT AFS BAREILLY
2022_MES_515438_1
81310/E8
Open Tender
Civil Works - Roads
Item Rate
180 days
Bareilly
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Bareilly
₹2.0 L
Yes
23 May 2022
26 Mar 2022
2 May 2022
26 Mar 2022
30 Apr 2022
18 Apr 2022
27 Mar 2022 - 11 Apr 2022
60 days
Amount
Demolition of unreinforced cement concrete (Hardstanding) in ground floors and pavings exc 15cm thickness (below or above ground level) by mechanical tools and removing the debris outside the defence land complete all as specified and directed.
Excavating over areas (manual excavation), n exc 1.5 m deep and getting out in soft & loose soil all as specified and directed.
Removing demolished material (Item No.1) to a distance exc. 1.50 km but n exc. 10 km outside of defence complete all as specified & directed.
Removing surplus excavated soil to a distance exc. 1.50 km but n exc. 5 km and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified & directed.
Rolling and consolidating formation surfaces in cutting with 8 to 10 ton power rollar complete all as specified and directed.
M&L for 150 mm thick (compacted thickness) Hardcore of broken stone or boulders of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 7.5 cm thick each layer, watered and rolled with 8 to 12 ton power roller to a true surface to required gradient and camber complete all as specified and directed.
M&L for 150 mm thick (compacted thickness) PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of road/floor complete all as specified and directed.
M&L for 10 mm thick layer of sand including watering and rolling cpmplete all as specified and directed.
M&L for 400 micron transparent High Density Polyethylene film sheet Grade I conforming to IS-10889 laid over sand layer complete all as specified and directed. Note:-(i) Side lap of 150 mm and end lap of 300 mm shall be provided wherever required. The rate quoted shall be deemed included for the laps. (ii) Clear area only shall be considered for payment purpose and nothing extra shall be allowed for laps.
M&L for 150 mm thick (compacted thickness) PCC M-25 design mix (using 20mm graded crushed stone aggregate) as in pavement/floor including all necessary formwork complete all as specified and directed.
M&L for Finishing the concrete surface by brooming while the concrete is still green complete all as specified and directed.
M&L for Precast reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) as in slabs including formwork and provision of 60 mm opening for hook complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and complete as specified and directed.
M&L for forming 25 mm wide expansion joints to full depth of pavement concrete slab (depth of slab 150 mm) and primed and filled with and including compressible closed cell premoulded high performance joint filler board HD-100 (Sil Flex Dura board HD 100 of Supreme make or any other make as approved by E in C's Branch ) and provision of closed cell polyethylene back up rod 30 mm dia , and top 15 mm primed and sealed with and using polyurethane based sealing compound (Polyurethane joint sealant complying with BS5212 & BS 4254 and EN 141875-2003(for hydrolysis/ water resistance test) with suitable primer as per manufacturer's recommendation complete all as specified and as directed with minimum MAF±30 % (with ten years performance guarantee ) and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied by mechanical means including cutting edge of existing pavements for forming expansion joints between existing and proposed slab,if required with bull nosing of edges front of joint not exceeding 5mm wide complete all as apecified & directed. . Note : (i) Expansion joints shall be provided at spacing not exceeding 30 m as directed by GE. The expansion joints shall be cut to full depth and shall be formed as described here in above at locations as directed by GE, if the slabs are casted for longer lengths. The cost of full depth cutting as required for forming expansion joints at such locations shall also be deemed included in the contractor's quoted rate for above item. (ii) Filling of joints shall be done by a mechanized system. (iii) Quoted rates of above item shall also include the rates of compressible joint filler board.
M & L for forming dummy joint cutting 8mm to 10mm wide and 80mm deep with diamond cutter, two coats of priming and providing a 12 mm dia polyethylene backup rod with debonding tape and top 15 mm primed and sealed with and using polyurethane based sealing compound (polyurethane joint sealant complying with BS5212 & BS 4254 and EN 141875-2003(for hydrolysis/ water resistance test)) including initial 3 mm wide saw cut upto 97 mm depth with suitable primer as per manufacturer's recommendations including minimum MAF ± 30 % (with ten years performance guarantee ) and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied complete all as specified and directed.
M & L for forming construction joint 28 mm deep and 10 mm wide (using diamond cutter ), primed and providing a 12mm dia polyethylene back up rod/debonding strip and top 15mm primed and sealed and using polyurethane based sealing compound complying with BS5212 & BS 4254 and EN 141875-2003(for hydrolysis/ water resistance test) pumping the sides with minimum MAF+ 30 % ( with 10 years performance guarantee) and primer of specified make as per manufacturer's recommendation complete with bullnosing of edges of front of joint not exceeding 5mm wide complete all as specified and as directed..
M&L for Painting lines dashes in arrows on pavement of runway exc 10 cm width adequate Nos of coat of water base paint (3 coats) over a coat of primer incl preperation of surface with mechanical sprayer complete all as specified and directed
M/s Arihant Builders
M/s J P Bhatia
Shikhar ji Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .