Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.8 L+₹2.9 L (8.68%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹36.8 L+₹3.8 L (11.5%)Rejected-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹37.9 L+₹5.0 L (15.0%)Rejected-Finance H 45 MAHESH NAGAR AMBALA CANTT 133001 HARYANA | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹39.9 L+₹6.9 L (21.0%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L5 | Rejected-Finance Rejected being |
Tender Value
₹43.4 L
EMD Value
₹86,840
Closing Date
28 Mar 2024, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE(N)AMB-73/2023-24 SPECIAL REPAIR TO BUILDING. NO. P-15, P-16 (UNIT QTR GD, KOTE, AMN STORE, QM STORE AND STORAGE TO INCLUDING STRONG ROOM) AND P-161 (SINGLE OFFRS ACCN) OF CSR (AREN) AND CONSTRUCTION OF FOOTPATH OF 250 METER FROM LIVING
2024_MES_644415_1
GE(N)/AMB-73/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (N) AMBALA CANTT
As per tender doucments
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹86,840
Yes
21 May 2024
28 Feb 2024
30 Mar 2024
28 Feb 2024
28 Mar 2024
14 Mar 2024
28 Feb 2024 - 14 Mar 2024
Amount
Schedule 'A' Part-I (B/R itmes) Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removal the rubbish/ demolished material outside defence land, complete all as specified and directed by the Engineer-in-Charge..
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes or PVC pipe any dia, set in cement mortar including taking out of trenches, if required complete all as specified .
Surface excavation (not exceeding 30cm deep) and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material to a distance not exc. 50m and depositing where directed complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage complete all as specified and as directed by the Engineer-in-Charge.
M&L PCC 1:5:10 type E-2, using 40 mm graded crushed stone aggregate as in filling in sunken floor, rounded or chamfered on edges complete all as specified.as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (design Mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-25 (design mix) using 20mm graded crushed stone aggregates as in chajjas and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork upto height 10m to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc., also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work using old serviceable bricks obtained from serial item No 03 above including removing motar, cleaning the bricks with water, etc. straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L for cutting out concrete blocks, slabs, brickwork or stone masonry (in alternate course), forming toothings and bonding new work in CM 1:4 into old work, including new materials entering old wall PCC 1:2:4 type B1 using 20mm graded aggregate complete all as specified and as directed by the Engineer-in-Charge.
Taking down wooden chowkats or frames area not exceeding 1.50 Square metre each and refixing, resecuring in same opening complete all as specified and as directed by the Engineer-in-Charge
Taking down wooden chowkats or frames area exceeding 1.50 Square metre and not exceeding 4.00 Square metre each and refixing, resecuring in same opening complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing butt hinges 100mm size, type B-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing aluminum anodized,peg stay, 150mm long, ISI marked and fixed to window/ventilator complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel curtain rod 25mm dia having wall thickness 1.6mm fixed with and including stainless steel decorative brackets, two lotto for each road length at both end etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed by the Engineer-in-Charge.
M & L for hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 6 to 8mm dia cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of apertures 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M & L 25 mm thick PCC 1:2:4, type B0 as in sub base of floor (using 12.50mm graded crushed stone aggregate), finished even & fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge. Note- This item shall not be executed in the location, where dismantling of tiles work have been done.
M&L Non Skid coloured ceramic tiles joint free premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/ skirtings/dados of size 300 x 600 x 7 mm thick or nearest size as required , set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour vitrified ceramic light shade tiles, double charged, premium/1st quality 10mm thick (square/rectangular) area of each tile exceeding 0.42 sqm and not exceeding 0.64 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick cement screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour vitrified ceramic light shade tiles premium/1st quality 10mm thick of same description as of floor tiles as in serial item No 39 above but 100mm to 200mm height as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M &L 10mm thick heavy duty, coloured paver tiles of size 300 x 300x 10mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement mortar 1 :4 ,complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 18-20 mm thick Baroda green stone slab (of any type) work, table rubbed and polished in steps, treads, riser, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble over and including 15mm thick rendering in CM 1:4 and round moulding to edges cills, cooking platform, etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L vibratory rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 60 mm thickness, grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on brick or stone walls etc. including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4 including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
Material and labour rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour rendering 05 mm thick on any faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 10 mm thick in cement mortar 1 :4 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for applying water proofing treatment to sunken slab comprising of the following specifications complete all as specified. (i) Cleaning of roof surface with mechanical means i.e. wire brush/air blower etc. and remove all loose /unsound material,dirt,dust etc. (ii) 15mm thick cement plaster on concrete surfaces in cement mortar (1:3) using and including water proofing compound @3% by weight of cement finished even and smooth without using extra cement, (iii) First layer of cement slurry @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm of approved make and allowed layer to air cure for 04 hours. (iv) Second layer of cement slurry @ 0.244 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.126 Kg/Sqm and allowed layer to air cure for 04 hours.. Note :- The water proofing treatment shall be carried out by the manufacturer or his authorised applicators and contractor shall also provide 07 years Guranttee for water proofing treatment carried out in the work. Sunken slab will be tested for 48 hour before carring out other works in sunken floor.
Supply only acrylic base polymer water proofing compound, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of oil bound distemper with painting roller and including 01 mm thick wall care putty white cement based in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over a 1 to 2 mm thick wall care putty white cement based in two or more coats to achieve smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
Dismantling boarding of any type/size as in cup board/wardrobes etc , fixed in any position with nails including hardware, wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified.
S & F 5mm PVC hollow sheet (the thickness of inner wall 0.7 to 1.00mm) wall panelling inclusive of solvent cement and fixing at site with U clip or PVC frame as per specifications and drawing complete all as specified and as directed by the Engineer-in-Charge.
Supplying & Fixing for customised and moulded toughened glass 12 mm thick as in partition , door fixed with patch fittings of stainless steel grade 304 including drilling holes for patch fittings and spider fitting as required with locking arrangement including rubber gasket complete, all as specified and as directed by the Engineer-in-Charge.
Supplying & Fixing for 25 to 30 mm stainless steel channel of grade 304 including cutting in floor as in top to fix or hanging glass as in top inlcuding suspending to channel to hang glass as in partition & fixed along wall with patch fittings of stainless steel to receive glass of any description and embedding the channel for receiving glass and filling silicon, etc., complete, all as specified and as directed by the Engineer-in-Charge.
M&L 12 mm thick pre-laminated particle board interior grade (grade-1) confirming IS 14587 pre-laminated both side with decorative choice lamination and fixed to aluminium frame with glazing clips, rubber and fixed with screw to wooden frame work complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore, ISI marked, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore, ISI marked, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, and making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 (using 20mm size crushed stone aggregate) smooth finished and reforming benching as required of pipe 110 mm dia, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair bib taps 15mm bore fancy type brass chromium plated with long body, SI marked, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F CP brass wall mixer 3-in-1 system with provision for both hand shower and overhead shower complete with 115 mm long bend pipe , connecting legs & wall flange with hand & overhead shower as in repair complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing , chromium plated, stop cock angular type, ISI marked, 15mm dia, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or unions, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing , chromium plated, stop cock, ISI marked, 20mm dia, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or unions, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixed (in repair), stop valves, 15 mm dia pipe, chromium plated, fancy type, ISI marked, screwed down, high pressure with capstan head, (concealed type) with long shank and cup, screwed both ends for iron pipes or for unions, complete all as specified and as directed by the Engineer-in-Charge. (Note : Weight of stop valve shall not be less than 0.575 Kg)
Supply and fixed as in repair fancy type, shower rose 125mm size with shower arm 195mm , brass Chromium plated, revolving type, fixed to existing steel pipe or union 15mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair brass chromium plated WHB mixer for mixing hot & cold water for 15mm bore pipes including all connecting fittings, screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair coloured, vitreous China, box type, toilet paper holder fixed with chromium plated brass screws, complete all as specified and directed .
Single piece water closet wtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern fittings P Trap complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No SLS -WHT-6855S / /CERA Cat part No.S10131095 /Hindware Cat Part No.92099 (S-30)
S & F as in repair vitreous china table top wash hand basin white, of size 565mmx420mmx140mm fixed on and including 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
Supplying & Fixing as in repair for stainless steel plate rack standard size 600mmx750mm x 200mm complete and fixing with rawl plug and steel screws of weight not less than 5 kg each, complete, all as specified and as directed by the Engineer-in-Charge. (Make : Jainko Cat No. KRJ-2 or equivalent model in makes mentioned in Appendix 'B' of tender document )
S & F sinks with drainage board made out of stainless steel 1mm thick sheet for kitchen with plugs, waste pipe, brass chromium plated coupling including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm as in repair complete all as specified and as directed by the Engineer-in-Charge
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws as in repair complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing 110mm dia UPVC, soil waste drain pipe, type ‘B’ , conforming to IS 13592-1992, single socketed, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wall, complete all as specified and directed by the Engineer-in-Charge..(Note- Rubber rings for pipes and fittings shall be confirm to IS 5382-1985)
Supply and fixing 75mm dia UPVC, soil waste drain pipe, type ‘B’ , conforming to IS 13592-1992, single socketed, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wall, complete all as specified and directed by the Engineer-in-Charge.(Note- Rubber rings for pipes and fittings shall be confirm to IS 5382-1985)
Supply and fixing 150mm dia UPVC, soil waste drain pipe, type ‘B’ , conforming to IS 13592-1992, single socketed, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wall, complete all as specified and directed by the Engineer-in-Charge.(Note- Rubber rings for pipes and fittings shall be confirm to IS 5382-1985)
Supply and fixing 150 mm bore UPVC (SWR) plain bend any radius including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 110 mm bore UPVC (SWR) plain bend any radius including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge. (Note- UPVC bends shall be confirm to BS 4515 DIN 19531 and DIN 19534)
Supply and fixing 75 mm bore UPVC (SWR) plain bend any radius including jointing with solvent cement, complete all as specified. (Note- UPVC bends shall be confirm to BS 4515 DIN 19531 and DIN 19534)
Supply and fixing 75 mm bore UPVC (SWR), vent cowls including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
M & L as in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 litre and not exc. 500 litres and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing water storage tank, 500 litre capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm bore high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by the Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for wire brushing and cleaning top surfaces of cement concrete/brick tiles incl roughening surfaces of old concrete by picking, sweeping and washing down with water to remove dust and brushing the surface with neat cement slurry @ 3.00 kg/Square metre, complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in padding, levelling course, etc. and surfaces finished even and smooth without using extra cement including form work where ever required complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC 1:2:4 type B-0 (using 12.5 mm graded mechanical crushed aggregate) for benching, coving, roof kerb shall be 150 mm in radius mixed with acrylic bases polymer water proofing compound, complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 litre /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc. after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L precast cement concrete tiles of size 25cm x 25 cm x 20mm thick machine pressed laid on screed bed and joints grouted flush in CM (1:3) mixed with 5% WPC by weight of cement including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of cement base paint complete all as specified and as directed by the Engineer-in-Charge.
M & L frosted sheet glass 4.8mm thick ordinary quality and glazing with aluminium snap beading, rubber gasket in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) for doors,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/ stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. Note : (a). Glazing shall be measured and paid separately; (b). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (c). The rates quoted shall be inclusive of neoprene beading, glazing clips, jointing clips, screws, etc as required and the same shall not be measured for arriving the weight; (d). The rates shall be inclusive of locking arrangement including complete packing with silicon gel all around contacting surface of aluminium framework and including matching the existing surface area complete all as specified and directed.
Supply and fix 100 mm size mild steel mortice lock, vertical type, 4 levers with duplicate key complete all as specified and as directed by the Engineer-in-Charge.
S&F 20 mm bore Gun–metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair complete all as specified and as directed by the Engineer–in–Charge.
Cutting holes into or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete of size exc 400 sq.cm but n.exc. 0.10 sqm upto height 10 mtr complete all as specified and as directed by the engineer-in-charge
M&L providing precast cement concrete 1: 2:4 type B0 (using 12.50mm thick crushed stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Precast frame shall be measured separately and set in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for stainless steel grade 316 D Type handle of size 325 mm overall length of dia 25 mm including gasket to prevent contact between glass & metal complete all as specified and as directed by the engineer-in-charge
Schedule 'A' Part-II (E/M items) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc. complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting electrical connection, taking down ceiling fans/exhaust fans of any sweep of any make with down rods, blades canopy etc and deposited in AGE E/M store yard safely and after completion of civil works cleaning the fan motor assembly body, blade of ceiling/ exhaust fan, filling the cavity, rubbing with sand paper, taking off old paint with the help of chemicals & painting the ceiling fan/exhaust fans with one coat of superior quality synthetic enamel paint including writing the MES number on the ceiling fans/exhaust fans with synthetic enamel paint, reassembling the ceiling fan/exhaust fans and refixing on the same loction, making electrical connection with 3 core copper condctor flexible cable of size 1.5sqm, testing complete all as specified and as directed by the Engr-in-charge.
Disconnecting electrical connection, taking down single/ three phase electric meter, and deposited in AGE E/M store yard safely and after completion of civil works cleaning the electric meter and refixing on the same location, making electrical connection, testing complete all as specified and as directed by the Engr-in-charge.
Disconnecting the electrical connection, taking down carefully unserviceable sub main wiring along with conduit pipe and all accessories and removal from site complete all as specified and as directed by the Engr-in-charge.
Taking down carefully existing electric water storage heaters of any capacity, description, model and and deposited in AGE E/M store yard safely and after completion of civil works, refixing the same after cleaning, painting with one coat of superior quality synthetic enamel paint including writing the MES number and replacement of defective PVC connection etc complete all as specified and as directed by Engineer-in-Charge
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets, modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No.111 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 111 but for One 3 pin 5 Amps socket outlet controlled by one switch on Same board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per srl item No 111 here-in-before but for one socket outlet 15 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description same all as per srl item No 111 here-in-before but for one socket outlet 15 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 3/3 pin combined (6 pin) , 16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F of electronic Fan regulator modular 120 watt, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
S&F modular bell push 6 Amp, 1 way, 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply & fix as in repair calling bell ding dong 230 volt, single pole, complete all as specified and as directed by the Engineer-in-Charge.
Supply & fix TV socket, single pole, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for medium grade, ISI marked, PVC conduit 20 mm dia with accessories, concealed on wall/ceiling surfaces with one run of coaxial cable suitable for TV socket, etc. complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, aluminium housing, surge protection including driver & LED lamp etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
Material & labour as in repair for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
S&F as in repair mirror light 9/12watt LED wall mounting fixture, one feet , aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 9/12 watt LED light fitting wall mounting fixture (sketch type) including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement indoor decorative LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient PVC housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 35 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-66 protection and other connected accessories including electronic driver, service bracket of mild steel pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge.
S & F LED Bollard 8-10 watt, IP-65 , 6500 K luminaire made of pressure die cast aluminium housing and clear glass , 240 volt, 50HZ, AC supply , complete with all accessories including electronic driver, internally pre wired including connecting with three core flexible copper conductor cable from Electric Supply Source to connector of the light including excavation and PCC 1:3:6 of size 400x400x400mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) with and including MCCB, 4 pole, 63 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door IP-54 protection duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface after removing old Unserviceable MCB DB surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 protection fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB Single pole, 5 to 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB Single pole and neutral, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying, passing through pipe, 1100 Volts grade heavy duty, two core, 6 Sqmm size nominal cross section cable, PVC insulated, aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including removing old unserviceable existing cable complete all as specified and as directed by the Engineer-in-Charge.
M & L as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in steel conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of steel conduit shall be measured and paid as one unit length.
Note:- Amount of credit of Rs. 1,28,441.00 for retrieved materials is mentioned in Schedule of Credit Page No. 41 & 42 (R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
M/s B.S.Jain
Durga Enterprises
dhingra builders
Gupta Enterprises
Saurav Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .