Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.1 L+₹1.3 L (9.41%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.3 L+₹1.5 L (10.8%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹14.3 L
EMD Value
₹28,700
Closing Date
13 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS
PROVISION OF BATHROOM AND TOILET WITH ALLIED INF AT HAWS, GULMARG UNDER GE 969 EWS
2020_MES_353225_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Gulmarg
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹28,700
Yes
6 Aug 2020
16 Jun 2020
15 Jul 2020
16 Jun 2020
13 Jul 2020
30 Jun 2020
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,for laying of cable etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-In-Charge.
M&L for plain cement concrete type D2, 1:4:8 (40 mm graded stone aggregate) in foundations filling and mass concrete. Complete all as specified and directed by Engineer-In-Charge.
Returning/ filling in including spreading levelling, watering and well ramming in layers n.exc 25 cm. Complete all as specified and directed by Engineer-In-Charge.
Removing of excavated soil not exceeding 50 m and depositing where directed at a level n.exc 1.50 m above the starting point. Complete all as specified and directed by Engineer-In-Charge.
M&L for walling of random rubble masonry built in cement mortar 1:6 brought up to courses. Complete all as specified and directed by Engineer-In-Charge.
M&L for providing cement concrete Type B-1, 1:2:4 (20 mm graded stone agg) as in copings plinth Courses, bond stones including use of form work. Complete all as specified and directed by Engineer-In-Charge.
M&L for damp proofing course to horizontal surface including necessary formwork in cement mortar 1:2:4, type B-0, 40mm thick complete. Complete all as specified and directed by Engineer-In-Charge.
M&L for brick work with sub class B' (old size) bricks, straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:6. Complete all as specified and directed by Engineer-In-Charge.
M&L for brick work with sub class B' (old size) bricks, straight or curved on plan exceeding 6 m mean radius in half brick thick walls built in CM 1:6 Complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement. Complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15 mm thick on brick work surfaces other than fair faces of brick work in cement mortar 1:6. Complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15 mm thick cement plaster on stone masonary surfaces or surfaces of other than fair faces of brick work or one side of lathing in cement mortar 1:6. Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash. Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer. Complete all as specified and directed by Engineer-In-Charge.
M&L for hard core of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and ramm to true surface. Complete all as specified and directed by Engineer-In-Charge.
M&L for 75 mm thick cement concrete type D2, 1:4:8 (using 40 mm graded stone agg) as in sub base of flooring, Complete all as specified and directed by Engineer-In-Charge.
M&L for 75 mm thick cement concrete type C2, 1:3:6 (using 20 mm graded stone agg) as in plinth protection and similar works including finishing the surface of concrete topping even and fair, without using extra cement. Complete all as specified and directed by Engineer-In-Charge.
M&L for roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (unframed work). Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, Complete all as specified and directed by Engineer-In-Charge.
S&F mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed not less than 0.9 mm dia. Complete all as specified and directed by Engineer-In-Charge.
S&F mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed not less than 0.9 mm dia. Complete all as specified and directed by Engineer-In-Charge.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for fair finished surfaces in any position flat or curved. Complete all as specified and directed by Engineer-In-Charge.
M&L for form work to sides and soffits of floor or roof beam, haunchings, girders, bressumers, lintels, cantilvers etc,also splays between floor and beams, etc, in rough finished surface of concrete.
M&L for RCC ,nominal mix, 1:1.5:3 (20 mm graded stone aggregate) as in foundations, including rafts,footings, foundations beams,plinth beam, bases for columns etc basement slabs, under rammed piles and mass concrete,beams cantilvers, bressummers, lintels over 1.5 m span, Complete all as specified and directed by Engineer-In-Charge.
M&L for RCC ,nominal mix, 1:1.5:3, (20 mm graded stone aggregate) as in beams, cantilvers, brassumers, lintels over 1.50m span and the like Complete all as specified and directed by Engineer-In-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Complete all as specified and directed by Engineer-In-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Complete all as specified and directed by Engineer-In-Charge.
S/F PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing sown in SSR Part II, Complete all as specified and directed by Engineer-In-Charge.
S/F factory made solid PVC moulded door shutter 28 to 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channe having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & and as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in SSR. Complete all as specified and directed by Engineer-In-Charge.
M&L for PCC 1:3:6, type C-1, using (20 mm graded stone agg) for hold fast blocks, including necessary form work for rough finished surfacess etc. Complete all as specified and directed by Engineer-In-Charge.
S&F for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), hold fasts, wall ties hooks and similar artiles conforming to Fe-290 Gde E-165. Complete all as specified and directed by Engineer-In-Charge.
S&F 125 mm long cast type anodised aluminium handles. Complete all as specified and directed by Engineer-In-Charge.
S&F MS butt hinges 100mm medium weight cold rolled etc. Complete all as specified and directed by Engineer-In-Charge.
S&F 200 mm long aluminium anodised barrel tower bolt of extruded section. Complete all as specified and directed by Engineer-In-Charge.
S&F 250 mm long Aluminium alloy sliding bolt with Hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded sections or cast alu alloy. fabricated type, Complete all as specified and directed by Engineer-In-Charge.
S/F 2nd class soft wood small fittings such as brackets of any type , latch and hinge blocks, shaped door and window stops and the like, including all necessary labours, articles n.exc 200 cu.cm each
Cutting holes in brick walls built in cement mortar not exc half brick for inserting hold fast etc and making good dismantled portion in cement mortor 1:3 or cement concrete 1:2:4 Type B1 as required at site.
M&L for providing 25 mm thick cement concrete Type B-1, 1:2:4 (20 mm graded stone agg) including finishing the surface even and rough, Complete all as specified and directed by Engineer-In-Charge.
M&L for non skid coloured ceramic tiles 300x300x6-7 mm thick in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6. Complete all as specified and directed by Engineer-In-Charge.
S&F glazed ceramic coloured tiles in verticles surfaces of size 450x300x7 mm thick set and jointed in neat cement slury and pointed white or coloured cement to match tile surface over and including 10 mm thick plaster in cement and sand mortar 1:4, Complete all as specified and directed by Engineer-In-Charge.
S&F 4 mm thick figured glass pin head type and glazing with oil putty in squares n.exc 0.50 sqm in each pane.
S&F steel ventilators with top hung shutter including hinges steel peg stay,Complete all as specified and directed by Engineer-In-Charge.
S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75 mm bore pipe. Complete all as specified and directed by Engineer-In-Charge.
All as per sr. item no.43 above but 110 mm bore of pipe.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors for 75 mm bore pipe. Complete all as specified and directed by Engineer-In-Charge.
All as per sr. item no.45 above but 110 mm bore of pipe
S&F for PVC (SWR) bend with access door inluding jointing with solvent cement 75 mm bore Complete all as specified and directed by Engineer-In-Charge.
All as per sr item no. 47 above but 110 mm bore.
S&F PVC (SWR) vent cowl, plain including jointing with solvent cement 110 mm bore Complete all as specified and directed by Engineer-In-Charge.
S&F PVC (SWR) floor trap plain with grating including jointing with solvent cement 75 mm bore Complete all as specified and directed by Engineer-In-Charge.
S&F for (SWR) gully trap, plain with grating includingjointing with solvet cement 110 mm bore Complete all as specified and directed by Engineer-In-Charge.
S&F vitreous china squatting pan "Orissa pattern" size 580x440 mm white with integral foot rest(exclding flushing cistern and flush pipe) including connection to trap, etcand to flushing pipe, sntysyponage pipe, etc, complete making good to floor. Complete all as specified and directed by Engineer-In-Charge.
S&F PVC low level flushing cistern , syphonic action type, 10 ltr capacity with inlet ball valve and float and handle and including brackets & PVC bend pipe 90 cm long etc, Complete all as specified and directed by Engineer-In-Charge.
S&F vitreous china wash basin, white, flat back size size 630 x 450 mm including pillar tape, waste fitting chromium plated brass and rubber plug, procelain stopper, a pair of CI brackets, waste pipe and waste cupling of 32 mm dia of PTMT (half or full threaded) (min wt 45 grms) etc. Complete all as specified and directed by Engineer-In-Charge.
S&F tubular towel rail aluminium anodised 20 mm dia D-type 60 cm long betweeen flanges, including brackets and fixed to wall , Complete all as specified and directed by Engineer-In-Charge.
S&F PVC connection 15 mm size, length 450 mm, with PTMT nuts, Complete all as specified and directed by Engineer-In-Charge.
S&F pillar tap, CP fancy type of 15 mm with capstan heads, screwed down, high pressure, with or without lattered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe.
S&F 20 mm bore stop valve fancy type chromium plated high pressure with crutch or butterfly handle, screwed both ends for iron pipe, Complete all as specified and directed by Engineer-In-Charge.
S&F 15 mm bore angle cock, fancy type chromium plated high pressure with crutch or butterfly handle, screwed both ends for iron pipe, Complete all as specified and directed by Engineer-In-Charge.
S&F 1000 ltr capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all all as specified in SSR part -I and directed by Engineer-In-Charge.
S/F 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 25mm-210 gms, Complete all as specified and directed by Engineer-In-Charge.
S&F compound girders and stanchions, lattic girders aerial masts, staging for water tanks and the like including caps, bases, splices etc, built up from two or more beam or channel sections or angles with plates including all lattic bars, stiffensers, gusset plates, etc. conforming to Fe-290(Gde-E-165). Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthtic enamel paint over a coat of red oxide primer. Complete all as specified and directed by Engineer-In-Charge.
S&F 20mm outer dia of 3- layer PPR Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) unstalised and antimicrobial fusion welded having thermal stability for hot or cold water supply including all PPR pain & brass threaded polypropylene random fittings fixed complete to wall, celings or in floors.
S&F 25mm outer dia of 3- layer PPR Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) unstalised and antimicrobial fusion welded having thermal stability for hot or cold water supply including all PPR pain & brass threaded polypropylene random fittings fixed complete to wall, celings or in floors.
S&F brass chromium plated shower roses of 125mm size with or without swivel joints, including fixing to steel pipe or union. Complete all as specified and directed by Engineer-In-Charge.
S&F urinal, full vitreous China , white and full stall type etc. Complete all as specified and directed by Engineer-In-Charge.
M&L for 20 mm thick granite polished in wash basin counter and fixed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed by Engineer-In-Charge.
M&L for 6 mm thick veneered decorative Ply wood, grade 1 (with BWR resin) with decorative face veneers on one face has decorative veneer fixed with nails to timber frame work on ceiling etc.
S & F second class soft wood plain fillets square, rectangular or triangular in section, wrought secured with screws, cross sectional area exceeding 6 sqcm and not exceeding 13 Sq.cm Complete all as specified and directed by Engineer-In-Charge.
Construction of LLDPE Septic tank exc inordinary soil foundation in PCC 1:2:4 brick work in CM 1:4 RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all arround/fiber reiforced cover with angle iron frame vent shaft and sludge chamber etc complete for 20 users complete all as specified and shown in drg No.CESZ/TD-1080/2011 and Complete all as specified and directed by Engineer-In-Charge.
Construction of Soakage well exc in ordinary soil foundation in PCC 1:3:6 well of honey combed and solid in M-25 concrete including intercepting chamber screen chamber brick work in 1:4 cm, RCC cover slab in M-25/RR masonary /filling with brick bats, complete of size 2.40 m dia x 3.00 m deep.complete all as specified and shown in drg No.CESZ/TD-1080/2011 and Complete all as specified and directed by Engineer-In-Charge.
M&l Cutting into existing manholes for connecting new drains pipe making good to pipes rendering cutting out existing benching for & forming branch channel (1/2 round of ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required internal dia of pipe 150 mm dia Complete all as specified and directed by Engineer-In-Charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone agg in foundation and mass concrete Complete all as specified and directed by Engineer-In-Charge.
M & L Brick work with sub class 'B' burnt bricks (old size bricks) straight on curved on plan exc 6 M mean radius built in CM 1:4 Complete all as specified and directed by Engineer-In-Charge.
M&L for 150 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars Complete all as specified and directed by Engineer-In-Charge.
M&L for concrete bed to drain pipes in PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate including packing under haunching against the sides of pipe after they are laid and tested for 150mm dia Complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with WPC, finished even and smooth Complete all as specified and directed by Engineer-In-Charge. (Note: WPC shall be measured and paid separately)
M&L for for rendering 15mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth complete.
Supply only integral water proofing compound Complete all as specified and directed by Engineer-In-Charge.
M&L Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc Complete all as specified and directed by Engineer-In-Charge.
Extra for forming fair faces (finished) drain of channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitered stopped end etc Complete all as specified and directed by Engineer-In-Charge.
Mild steel TMT bars 8 mm dia, quality conforming to Grade 415 MPA cut to length , bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia Complete all as specified and directed by Engineer-In-Charge.
S&F Rolled mild steel in joist channel, angle(size 50x50 x 6 mm th), or tee sections fixed independly, without connecting plates, etc (cut to ordinary length) of Fe 410-W (Gde-E- 250) quality- A Complete all as specified and directed by Engineer-In-Charge.
M & L precast RCC man holes cover in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate Complete all as specified and directed by Engineer-In-Charge.
M&L for Providing cement concrete Type C-1, 1:3:6 (20mm graded crushed stone aggregate) as in surface channel and drain Complete all as specified and directed by Engineer-In-Charge.
Flush pointing to random rubble masonry, uncoursed or brought up to course in cement mortar 1:4 Complete all as specified and directed by Engineer-In-Charge.
M&L for extra stone walling for hammer dressing to faces stone of random rubble walling uncoursed 40 mm lime of sand stone. Complete all as specified and directed by Engineer-In-Charge.
M&L for extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement concrete, incl forms, mould mitred/stopped end etc Complete all as specified and directed by Engineer-In-Charge.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor. Complete all as specified and directed by Engineer-In-Charge.
All as per sel item No. 91 above but One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size Complete all as specified and directed by Engineer-In-Charge.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor Complete all as specified and directed by Engineer-In-Charge.
S & F switch piano, flush type single pole, one way 5/6 Amp Complete all as specified and directed by Engineer-In-Charge.
S&F flush type switch socket combination 16A, 5 in 1 pin, Complete all as specified and directed by Engineer-In-Charge.
S & F ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 10W LED complete all as specified and as directed. Make : Havells/ BAJAJ/PHILIPS/CG
Supply and fixing endura linear leo surface and mounted LED tube light fitting 20W, four feet, extruded aluminium housintg provided for efficient heat dissipation with polycarbonate diffuser & integerated electronic driver complete all as specified and as directed by Engr in Charge. Make Havells/Bajaj/ Philips/CG
Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body Complete all as specified and directed by Engineer-In-Charge.
S&F LED Lamp 10 W Complete all as specified and directed by Engineer-In-Charge. Make : Havells cat No. LHLDERUEML8X010/ Philips / Bajaj/ Crompton
S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting Complete all as specified and directed by Engineer-In-Charge. Make : Anchor / Cona / Bajaj
S&F LED Mirror Light "Eco Smart Linea" 18 Watts made of extruded engineering plastics suitable for surface mounting on a ceiling or wall Complete all as specified and directed by Engineer-In-Charge. Make : Crompton Cat Part No LDESL18-CDL or equivalent in Havells/Philips/Bajaj
S&F Sheet metal enclosure for 4 way DBs when MCB to be used single phase 240 volts, single door Complete all as specified and directed by Engineer-In-Charge.
S&F MCB single pole of capacities 6 to 32 amp, 240 volts Complete all as specified and directed by Engineer-In-Charge.
S & F MCB SPN of capacities 32 Amps, 240 Volts, Gold plus complete all as specified and directed by Engr-incharge.
Supply and fixing ventilating Exhaust fan 200 mm sweep 230 volts, plastic type AC connecting up including provision of cable from ceiling rose/ connector to fan Complete all as specified and directed by Engineer-In-Charge.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc
Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 2 core 6 Sq mm Complete all as specified and directed by Engineer-In-Charge.
Supply and Fixing 25mm dia GI tubing,medium grade,ISI Marked complete with all fittings,Laid in trenches or floors,fixed on wall with and providing clamps etc.Complete all as specified and directed by Engineer-In-Charge.
Cutting of existing GI pipe line of size 25 mm dia and inseting new pipe line including all fittings Complete all as specified and directed by Engineer-In-Charge
S & F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or unions and fixed complete including taking down of old one suitable of 25 mm dia sizes Complete all as specified and directed by Engineer-In-Charge.
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed. (Note: The punned down thickness shall only be measured)
Supply and laying sub class 'B' bricks laid across the cable for cable protection complete Complete all as specified and directed by Engineer-In-Charge.
Javeed And Co
m/s mohd rafiq lone
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .