Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹28.8 L+₹4.4 L (17.9%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹33.8 L+₹9.3 L (38.1%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Nov 2023, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
MAINTENANCE / REPAIR AND REPLACEMENT OF STREET LIGHTS WITH CONNECTED ITEMS / MISC E/M WORKS OF ALL SUB STATIONS / MAINT / REPAIRS OF LIFTS IN TECH AREA AT AIR FORCE STATION BIDAR
2023_MES_624991_1
85605/E8
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF BIDAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AF BIDAR
₹80,000
Yes
19 Dec 2023
26 Oct 2023
2 Dec 2023
26 Oct 2023
30 Nov 2023
11 Nov 2023
26 Oct 2023 - 6 Nov 2023
Amount
Comprehensive maintenance of electrically operated Passenger lift No 1 at Left side of staircase of New ATC building of capacity (8 persons), 544 Kgs, Door opening 800mm of Make USHA complete all as specified and as per Notes below and as directed by the Engineer-in-Charge.
Comprehensive maintenance of electrically operated Passenger lift No 2 at Right side of staircase of New ATC building of capacity (8 persons), 544 Kgs , Door opening 800mm of Make USHA complete all as specified and as per Notes below and as directed by the Engineer-in-Charge. Notes for Sl item No 1.00 & 2.00 as below to be carried out by OEM only :- (a) Regularly & systematically examine, adjust lubricate as per standard operating procedure including testing yearly once and judgement conditions warrant the same repair / replace machine controller parts motor trust bearings, brake windings, contacts, coils, resistance for operating motor circuits and other mechanical parts. (b) To renew all wire ropes of equipment and to take reasonable care to maintain the equipment in proper and safe operating condition. (c) Examine periodically of all safety devices, governors and safety tests to be carried out as per OEM . (d) Repair replacement of misc worn out parts due to normal wear and tear.
(e) The servicing will be carried out once in 30 days by OEM technicians or his representative and service completed report shall be got signed from the User/ MES authority. (f) All responsible steps shall be taken to maintain the equipment in proper operating condition. (g) The contractor shall employ well-qualified and well-experienced supervisory personnel who have minimum qualification of ITI certification in the trade to perform the maintenance services. (h) Services shall be conducted during normal working hours at regular intervals as frequently as the company thinks necessary, having regard to the age, complaint, nature and condition and problem in operation of the elevator. (j) Technician should be systematically inspect, adjust and lubricate the parts of the elevator to the extent necessary to maintain the elevator in satisfactory working condition. k) During the break down/ failure in the elevator, a technician must respond quickly to carry out the necessary repairs in order to restore the elevator functioning immediately. (l) Parts which are not covered in routine maintenance work like ARD Batteries, car panels, door parts will be measured and paid separetely.
RECOVERY NOTE for Sl item No 1 & 2 as below : - (a) Delay in making the lift serviceable for minor complaints more than 24 hours after lodging the complaint through telephone/ SMS will attract recovery @ Rs 500/- per day (irrespective of full day or part thereof) (b) Delay in making the lift serviceable for major complaints more than the time fixed by the Accepting officer will attract recovery @ Rs 1000/- per day (irrespective of full day or part thereof) (c) Any minor spares required for making the lift serviceable shall be deemed to be included in the rate quoted.
M&L for door operator drives 230 V input/110 V output including with R&F relay 24 V, 120 pin micro IC complete all as specified and as directed.
M&L for LOP & COP switches 24V, seven segment display, pcb mount NO switch complete all as specified and as directed.
M & L in replacement of the full Length door Sensor as per existing specification complete all as specified and as directed.
M & L in replacement of the Electrical Harness complete set with card speaker accessories as per existing specification complete all as specified and as directed.
M & L in replacement of the Car Operating Panel Landing Operating Panel suitable with existing system complete all as specified and as directed.
M & L in replacement of the Automatic rescue device with battery back up suitable with existing specification complete all as specified and as directed.
M & L in replacement of the S.S hairline finish landing car door complete all as specified and as directed.
M & L in replacement of the cabin light LED ceiling light of 1 Watt with suitable driver for existing ceiling complete all as specified and as directed.
M & L in replacement of the Emergency alarm complete with card, speaker, connected accessories and battery complete all as specified and as directed.
M & L in replacement of Gear oil with new oil complete all as specified and as directed. Note for Sl item Nos 3 to 12 :- The make of parts to be replaced will be as recommended by OEM.
Disconnection and removing carefully the unserviceable lift motor of capacity 12.5 HP from the shaft and rewinding the same with single strand fine enamel bared copper conductor of same guage, weight and turns and keeping the windings into hot air oven till the moisture evaporates and refixing the same in its original position after completion of repairs including connecting the cables and all the accessories testing and commissioning complete all as specified and as directed.
Taking down unserviceable light fittings and S&F high efficient LED street light fitting of 45 W 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete all as specified and as directed. Make :- Havells (ENDURASUNDOWNSL45WLED765PASYBOPC) / Philips / Crompton Greaves
Taking down unserviceable light fittings'and S&F high efficient LED street light fitting of 70 W 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete all as specified and as directed. Make :- Havells ENDURASUNDOWNSL70WLED765PASYBOTG) or equivalent in Philips / Crompton Greaves
Taking down unserviceable light fittings and S & F of 120 Watt LED flood light fittings integral type, with die cast housing with lens IP 66 complete all as specified and as directed. Make : - Havells (JETAIRISFL120WLED757APWBLTG ) / Philips / Crompton Greaves
S & F of 100 Watt LED flood light fittings integral type, with die cast housing with lens IP 66 including taking down unserviceable light fittings complete all as specified and as directed. Make :- Havells (JETAIRISFL100WLED757APWBLTG) /Philips / CG
S & F of 70 Watt LED flood light fittings integral type, with die cast housing with lens IP 66 including taking down unserviceable light fittings complete all as specified and as directed. Make : - Philips / CG / Havells (JETAALBAFLOODLIGHT70W ) /Philips / Crompton Greaves
S&F LED post top lantern 70 W with die cast aluminium spigot, spun aluminium powder coated top cover, aluminium powder coated heat sink, opal PC diffuser and clear acrlic, IP 65 including taking down unserviceable light fittings complete all as specified and as directed. Make : - Havells (CORALMAXIPT70WLED757PSYMTOPC) / Philips / Crompton Greaves
S&F LED post top lantern 25 W with die cast aluminium spigot, spun aluminium powder coated top cover, aluminium powder coated heat sink, opal PC diffuser and clear acrlic, IP 65 including taking down unserviceable light fittings' complete all as specified and as directed. Make :- Philips / CG / Havells Cat No :- CORALPT25WLED757PSYMTOPC or equivalent)
S&F 3 core, 2.5 sqmm PVC insulated PVC sheathed multistranded flexible copper conductor cable drawn through existing conduit / pipe from junction box to fitting including taking down unserviceable cable complete all as specified and as directed.
S&F ready made junction box made from FRP sheet of size 250 mm x 200 mm x 100 mm having 100 Amps capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB SP 6 Amp 10 kA 240 V - 01 No. fixed to pole / wall with MS clamp 25 mm x 5 mm duly painted with one coat of red oxide and two coats of enamel / silver paint to MS clamp including taking down existing unserviceable junction boxes complete all as specified and as directed.
Supply and Fixing MCB TPN 16-32 Amps including disconnection and removing the unserviceable MCB complete all as specified and as directed.
Supply and Fixing MCB TPN 40-100 Amps including disconnection and removing the unserviceable MCB complete all as specified and as directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long, single swan neck type inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces including takin down the unserviceable steel tubular swaged poles complete all as specified and directed by the Engineer-in-Charg. The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161complete all as specified and as directed. Note :- Earth work and PCC foundation shall be measured and paid separately.
M&L for PCC 1:4:8, type D-2 mix (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel poles complete all as specified and as directed.
M&L for PCC 1:2:4, type B-1 mix (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified and as directed.
S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint including takin down the unserviceable cross arms and complete all as specified and as directed.
S&F Digital time switch Astro suitable for switching on/ off light and other elcric devices according to the rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/or fixed preset times and also suitable for daily astronomicaal calculation of the sunrise/ sunset time based on the entered locaton or loation coordinates . Model No : Cat No 4126 54 Make Legrand AlphaRex3 D21 astro, 1 channel and equivalent Make in the existing panel including taking down unserviceable timer switch complete all as specified and as directed.
M&L for painting to PCC pole/ Steel tubular poles with two coats of cement base paint of approved colour shade and writing Pole numbers with white paint having black background enamel paint suitable for outdoor, including cleaning of poles, removing creeper etc from pole complete all as specified and as directed.
M&L for checking the serviceability of street light/flood light fitting of any capacity from pole/bldg and refixing the same after all repair work including wiring from OH LT line complete all as specified and as directed.
Supply and fixing aviation obstruction light fitting including lamp and connecting with suitable size cable including taking down old unserviceable one complete all as specified and as directed.
M&L for street light bracket made out of 40 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding, drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc including disconnection & taking down the unserviceable GI bracket of size 40 mm dia from the pole / building complete all as specified and as directed.
M&L for street light bracket made out of 25 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc including disconnection & taking down the unserviceable GI bracket of size 25 mm dia from the pole / building complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor 6 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Checking/ identifying the faulty precisely pin pointing of HT (11 KV) cable using cable fault locator machine of most advanced system with multi level safety, quickely and rectify the defects with necessary excavation, removing of defective portion, adding essential size of cable in required length (min 5 RM), meggering & re-stortion of electric supply of HT external electric feeder complete all as specified and as directed by the Engr-in-charge for any length of cable (approx 1 Km) Notes :- (i) Cable fault locator machine with all T&P required for identifying the faulty point will be arrange by contractor which cost is included in unit rate. (ii) Straight through joint will be measured & paid seperately under relevant item. (iii) upto 03 Nos faults in one length span of cable is measured in one Job. More than will measure add-on cumulatively. (iv) on cable fault tracing obstructions like bush/grass/plants/soil dunes cleaning deemed to include in the quoted rates.
Supply & fixing Pin type,Polymer insulator 11 KV 320 cd 5 kn for 11000 volts grade complete including all accessories yoke,clamps,nuts,bolts etc complete all as specified and as directed.
Supply & fixing Disc type,Polymer insulator 11 KV 320 cd 45 kn for 11000 volts grade including all accessories yoke,clamps,nuts,bolts etc complete all as specified and as directed.
Supply & fixing ACSR conductor in OH lines conductor (Squirrel / Weasel / Rabbit) including binding with aluminium wire including taking down unserviceable conductor complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 50 kA, 400 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 35 kA, 250 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 35 kA, 200 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 16 kA, 125 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 16 kA, 100 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 16 kA, 63 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply and fixing new interior unit with sheet metal enclosure on load change over switch Conforms to IEC 60947-3, IS/IEC 60947-3 , 630 A ,4 P, 415 volts , 65 KA including disconnection and removing unserviceable on load change over switch front operated with metal enclosure along with cable connections complete all as specified and as directed.
Description all as per item No.47 above but of capacity 400 Amps, 4 P, 415 V, 50 KA complete all as specified and as directed.
Description all as per item No.47 above but of capacity 200 A,4 P 415 V , 35 KA complete all as specified and as directed.
Description all as per item No.47 above but of capacity 100 A,4 P 415 V , 25 KA complete all as specified and as directed.
M&L for Cleaning of outdoor Electric substation / Four pole structure / Two pole structure area free of vegetation and creepers by cutting vegetation / grass and cleaning the substation in side & upto 3 meter outside the fencing area including removal of cut vegetation and dumping at out side MD land and applyiing weedicide alongwith periphery for one meter width by the grass cutting machine complete all as specified and as directed. Note :- (i) Each Electric substation / Four pole structure / Two pole structure will be considered for one Job.
Repairs to Panel boards / busbar of any size by removing of incomer /out going cables and connecting with same size of new lugs , nut, bolts & welded the damgaged / broken portion making all doors to freely operatable by using grease and painting with one coat of synthetic enamel paint on metal surface of panels / busbar surface area etc.complete all as specified and as directed.
Taking down of HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches along complete all as specified and as directed.
Relaying of old serviceable HT XLPE/ PVC UG cable 11000 Volts grade ,3 core of any size/dia up to 240 Sqmm in the trenches complete all as specified and as directed.
Supply , lay and testing HT XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,3 core, 11000 volts, grade of the size 240 Sqmm complete all as specified and as directed.
Description all as per item No 55 here in above but of size 185 Sqmm complete all as specified and as directed.
Description all as per item no 55 here in above but of size 120 Sqmm complete all as specified and as directed.
Description all as per item no 55 here in above but of size 95 Sqmm complete all as specified and as directed.
M & L for indoor type jointing kit heat shrinakable for 11 KV grade UG cable end termination with 3 core Aliminium conductor of size 240 Sqmm along with jointing material and accessories complete all as specified and as directed.
Description all as per item No 59 here in above but of size 120 to 185 Sqmm complete all as specified and as directed.
Description all as per item no 59 here in above but of size 95 Sqmm complete all as specified and as directed.
M & L for outdoor type ,jointing kit,heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor of size 240 Sqmm along with jointing material complete all as specified and as directed.
Description all as per item No 62 here in above but of size 120 to185 Sqmm complete all as specified and as directed.
Description all as per item No 62 here in above but of size 95 Sqmm complete all as specified and as directed.
M & L for outdoor type Straight through ,jointing kit,heat shrinakable for 11KV grade UG cable with 3 core Aliminium conductor of size 240 Sqmm along with jointing material complete all as specified and as directed.
Description all as per item No 65 here in above but of size120 to 185 Sqmm complete all as specified and as directed.
Description all as per item No 65 here in above but of size 95 Sqmm complete all as specified and as directed.
Taking down LT XLPE / PVC UG cable 1100 V grade 10 Sqmm to 70 Sqmm 3.5 core connected from LT OH line to MCB DB, between the poles, transformer to LT Panels complete all as specified and as directed. Note : - Excavation and Earth work will be measured and paid seperately under the respective items
Supply, lay, connect, test and commisioning of LT XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor multistranded 70 Sqmm 3.5 core, 1100 volts grade including connecting the cable ends to the LT Panel/ Transformer /LT OH lines and distribution board complete all as specified and as directed. Note :- (i) The rates quoted shall be deemed to be inclusive of necessary end terminations connecting materials such as lugs, nut bolt washers, aluminium jumper wire to suits the existing system. (ii) Excavation, RFR, Removal of soil, PCC Cover, Sand for cable protection will be measured and paid seperately under the respective items of BOQ
Description all as per Item No. 69 here in before but of size 50 sq.mm 3.5 core complete all as specified and as directed.
Description all as per Item No. 69 here in before but of size 35 sq.mm 3.5 core complete all as specified and as directed.
Description all as per Item No.69 here in before but of size 25 sq.mm 3.5 core complete all as specified and as directed.
Description all as per Item No. 69 here in before but of size 16 sq.mm 4 core complete all as specified and as directed.
Description all as per Item No. 69 here in before but of size 10 sq.mm 4 core complete all as specified and as directed.
Description all as per Item No. 69 here in before but of size 10 sq.mm 2 core complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil etc. complete all as specified and as directed.
Supply and spreading fine river sand in trenches for cushioning of under ground cables complete all as specified and as directed. Note :- Only punned thickness 18 cm will be measured and paid .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cms complete all as specified and as directed. .
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and laying unreinforced pre cast concrete cable cover class HVP type 1 of flat size 300 mm x 180 mm x 40 mm for cable protection complete all as specified and as directed.
Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250 mm x 150 mm x 40 mm for cable protection complete all as specified and as directed.
Mr Madhusudhan Kotarki
RAVINDRA BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .