Loading…
Loading…
Tender Value
₹100.0 L
EMD Value
₹2.0 L
Closing Date
3 Aug 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SRDEEGTVC
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less where V= advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited , the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure -VI B, along with copies of Audited Balance sheet duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited balance sheet.
For electrical works, the contractor should have a valid electrical contractor license from the concerned statutory authority of any state of India. The electrical license should be in the name of the firm's or in the name of any authorized person of the tenderers firm. It must be ensured that the validity of electrical license should be valid during the entire contract period duly renewing at appropriate time for extending validity. If the tenderer hired the electrical license, authorization of the same should be submitted. 1)In case of other than Company/ Proprietary firm, Annexure - V(A) shall also be submitted by each member of a Partnership Firm/ Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. as the case may be. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested /digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
13 conditions · 1 needing a document upload
All the tenderers/Contractors have to deposit full earnest money and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions of contract , General Instructions and conditions , explanatory notes of schedule of work and Annexures.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of EMD and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Whether GST registration available or not?
The contractor has to submit the EPF Code as per the EPFO Act and also has to submit a statement in this regard before signing the contract agreement.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. The bidding rate is Rs./ unit, the bidder has to quote his rate for the individual item only
Subsequent to the enforcement of GST Act, the modifications to Para-(a),clause 6, part I of Indian Railways Standard General condition of contract, July 2014 vide Railway Board letter No: 2017/CE/CT/4/GST(a) of 23/6/2017 is as detailed below: Clause No.6 - Care in submission of Tenders: (a)(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (ii) Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/ Integrated Goods and Services Tax Act, 2017 (IGST)/Union Territory Goods and Services Tax Act, 2017 (UTGST)/respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to Railway immediately after the award of contract, without which no payment shall be release to the contractor. The contractor shall be responsible for deposition of applicable to the concerned authority. iv) In case the successful tenderer not able to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. The contractor is liable to pay the taxes as stipulated in the GST Act and Rules and also should furnish the details of GST to deduct from the contractor's bill.
Trivandrum: Setting up of quick watering arrangements at TVC for watering trains at PF-1&2,PF 3&4 and at PF 5 - Electrical arrangements
V-EG-OT-13-2026-2027
V-EG-OT-13-2026-2027
Open
Works - General
270 Days
Thiruvananthapuram, Kerala
₹0
₹2.0 L
3 Aug 2026
8 Jul 2026
20 Jul 2026
93 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 99,96,394 | ||
| — | 215.00 | — | — | ||
| "Supply & laying of HDPE pipe of 150/160 mm dia, pressure rating up to 4 PN (Material grade PE 63) conforming to IS 4984 /1995 in the excavated cable trench /Existing trench and threading of LTUG cable and termination at either ends using aluminium socket duly crimped (Cable will be supplied free, departmentally at TVC) " | — | — | — | 2,00,380 | |
| — | 230.00 | — | — | ||
| "Supply & laying of HDPE pipe of 110 mm dia, pressure rating up to 4 PN (Material grade PE 63) conforming to IS 4984 /1995 in the excavated cable trench /Existing trench and threading of LTUG cable and termination at either ends using aluminium socket duly crimped (Cable will be supplied free, departmentally at TVC) " | — | — | — | 1,10,630 | |
| — | 250.00 | — | — | ||
| Supply & laying of HDPE pipe of 50 mm dia, pressure rating up to 4 PN (Material grade PE 63) conforming to IS 4984 /1995 in the excavated cable trench and threading of LTUG cable and termination of either ends with suitable size heat sinc sleeve(Cable will be supplied free, departmentally at TVC and transportaion will be provided by railway. Loaidng and un-loading operation has to be arranged by contractor). | — | — | — | 40,000 | |
| — | 1000.00 | — | — | ||
| Drilling of cable duct under tarred road/railway track (minimum 6M below ground level) by Horizontal Direct Drilling (HDD) Method including only threading of 160mm dia PN-10, PE- 63/PE 80 grade HDPE pipe inside the cable duct made by Horizontal Direct Drilling (HDD) Method (100 M x three ducts ) | — | — | — | 34,81,000 | |
| — | 1000.00 | — | — | ||
| Supply of HDPE pipe 160mm dia PN-10, PE-63/PE 80 grade and threading of cable through the HDPE pipe laid inside the cable duct made by horizontal directional drilling (Cable will be supplied free departmentally at TVC) | — | — | — | 16,89,000 | |
| — | 18.00 | — | — | ||
| Supply and fixing of 'B' class GI pipes for cable leading /protection -150 mm diameter | — | — | — | 19,116 | |
| — | 100.00 | — | — | ||
| Clamping of LTUG cable 4 core x 300 sq. mm along building wall/structure etc complete with 25 x 6 mm GI fixing hardware(Cable will be supplied free, departmentally at TVC). | — | — | — | 24,200 | |
| — | 150.00 | — | — | ||
| Clamping of LTUG cable 4 core x120 sq.mm along PF shelter/ FOB/Cable tray etc complete with 25 x 6 mm GI fixing hardware including termination on looping boxes/Kiyosk/ switch room. (Cable will be supplied free, departmentally | — | — | — | 13,200 | |
| — | 50.00 | — | — | ||
| Clamping of LTUG cable 4 core x 16 sq.mm along PF Shelter /FOB/Building wall complete with 25 x 3 mm GI fixing hardware including termination on looping boxes /Kiyosk/Switch room.(Cable will be supplied free, departmentally at TVC). | — | — | — | 3,250 | |
| — | 10.00 | — | — | ||
| Supply & fixing of cast iron cable route indicator marked with " LT CABLE" including grouting with cement concrete | — | — | — | 5,300 | |
| — | 32.00 | — | — | ||
| Supply And fixing of cable gland suitable for LTUG cable 4 core x 300 sq.mm and termination using aluminium socket duly crimped with suitabe size heat shrinkable sleeve. | — | — | — | 26,496 | |
| — | 4.00 | — | — | ||
| Supply And fixing of cable gland suitable for LTUG cable 4 core x 16 Sq.mm and termination using aluminium socket duly crimped with suitabe size heat shrinkable sleeve. | — | — | — | 1,040 | |
| — | 132.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 1.0 m deep (preferably) in ordinary soil, back filling of the excavated cable trench (After laying of cables) , ramming & consolidation properly | — | — | — | 62,568 | |
| — | 8.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 0.1 m deep (up to the depth of tarr/concrete) in tarred/concreted surface back filling of the excavated cable trench After laying of cables), ramming & consolidation properly. | — | — | — | 15,656 | |
| — | 8.00 | — | — | ||
| Concreting the top portion of the cable trench excavated in tarred/concreted surface to a depth of 10.0 cm, using 1:2:4 mix with M sand | — | — | — | 70,344 | |
| — | 75.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 1.0 m deep under railway tracks (from formation level), duly removing stone ballast, back filling of the excavated cable trench (After laying of cable with HDPE pipe) , ramming & consolidation properly and providing back the removed stone ballasts. | — | — | — | 1,02,450 | |
| — | 2.00 | — | — | ||
| Supply and fixing and commissioning of IS/IEC certified 1 No. 400 A 36 KA 4P MCCB in metal enclosure (for fetching & Termination of supply with 300 sq mm cable) | — | — | — | 1,03,134 | |
| — | 2.00 | — | — | ||
| Supply and fixing and commissioning of IS/IEC certified 1 No. 160 A 36 KA 4P MCCB in metal enclosure (for fetching of supply with 120 sq mm cable) | — | — | — | 45,022 | |
| — | 3.00 | — | — | ||
| Supply and fixing and commissioning of 400 A 4P Off-load Changeover switch | — | — | — | 78,075 | |
| — | 2.00 | — | — | ||
| Fabication, supply, erection and commissioning of in door supply bunk fabricated out of 14 SWG MS sheet powder coated finish and fitted with(1) 630 A 4 P 36 KA MCCB (2) 04 Nos 50 x12 mm aluminium bus bar (appx length 500mm each x 2 layer), door with locking arrangements and with all accessories as per Drg No. V/E.24/2025-26. with wall mounting facility. | — | — | — | 1,67,028 | |
| — | 1.00 | — | — | ||
| Fabication, supply, erection and commissioning of Plinth mounted out door supply bunk (cut Bunk with two partition) fabricated out of 10 SWG MS sheet powder coated finish and fitted with (1) 1 No 400 A 36 KA 4 P MCCB (2) 04 Nos 70 x 12 mm AL Bus bar (appx length 300 mm each (3) 4 Nos. 50 x12 mm Aluminium bus bar (appx length 300 mm each), door with locking arrangements as per drg No. V/E.21/2025-26.(Including construction of concrete plinth as per the direction of Engineer in-charge) | — | — | — | 1,07,329 | |
| — | 1.00 | — | — | ||
| Fabication, supply, erection and commissioning of in door supply bunk fabricated out of 14 SWG CRCA sheet powder coated finish and fitted with (1) 1 No.630 A 4P 36 KA MCCB as in commer (2) 01 Nos 400 A 36 KA 4 P MCCB (3) 03 Nos. 250 A 25 KA 4 P MCCB (3) 01 No.125 A 25 KA 4 P MCCB (4) 04 Nos 70 x12 mm copper bus bar (appx length 1 M each), multi function meter, CT, all accessories,door with locking arrangements etc as per Drg No. V/E.18/CW/2025-26. | — | — | — | 3,44,839 | |
| — | 1.00 | — | — | ||
| Fabication, supply, erection and commissioning of in door supply bunk fabricated out of 14 SWG CRCA sheet powder coated finish and fitted with (1) 1 No.250 A 4P 36 KA MCCB as in commer (2) 06 Nos 100 A 25 KA 4 P MCCB (3) 04 Nos 40 x10 mm copper bus bar (appx length 1 M each),multi function meter, CT, all accessories,door with locking arrangements as per Drg No. V/E.25/2025-26. | — | — | — | 2,29,412 | |
| — | 2.00 | — | — | ||
| Fabication, supply, erection and commissioning of Plinth mounted out door supply bunk fabricated out of 10 SWG MS sheet powder coated finish and fitted with (1) 1 No 160 A 25 KA 4 P MCCB (2) 03 Nos 63 A 25 KA 4P MCC (3) 04 Nos 40 x 06 mm copper Bus bar (appx length 1.2 mm each (appx length 300 mm each),,multi function meter, CT, all accessories,door with locking arrangements as per Drg No. V/E.27/2025-26..(Including construction of concrete plinth as per the direction of Engineer in-charge) | — | — | — | 3,76,802 | |
| — | 2.00 | — | — | ||
| Fabication, supply, erection and commissioning of in door supply bunk fabricated out of 14 SWG CRCA sheet powder coated finish and fitted with (1) 2 Nos.400 A 4P 36 KA MCCB as in commer with mechanical inter lock (2) 01 No 250 A 36 KA 4 P MCCB (3) 03 Nos. 125 A 25 KA 4 P MCCB (3) 03 Nos.63 A 25 KA 4 P MCCB (4) 04 Nos 50 x12 mm copper bus bar (appx length 1.5 M each), multi function meter, CT, all accessories,door with locking arrangements etc as per Drg No. V/E.26/2025-26. | — | — | — | 7,97,600 | |
| — | 2.00 | — | — | ||
| Supply, erection testing and commissioning of MCB( MCCB + MCB out going) 6 Way Vertical Distribution Board , three phase MCCB + 18 Modules IP-43 protected, CRCA sheet enclosure powder coated with suitably rated insulated copper bus bars for phase, with neutral & earth bars,shrouds, cement spill protector,color coded inter-connecting wire sets,cable ties etc as applicable and fitted with the following accessoriesone (1) one No. 125 A 4P 25 KA MCCB Thermal magnetic + electronic earth leakage module as incommer (2) 03 No. 32 A 3 P MCB (3) 9 Nos 10 to 32 A SP MCB ( in a concealed/open manner as required at site. The MCCB/MCBs shall be IS/IEC certified | — | — | — | 1,18,028 | |
| — | 2.00 | — | — | ||
| Supply, erection testing and commissioning of MCB Distribution Board, Single phase 12 way, IP-43 protected, CRCA sheet enclosure powder coated with suitably rated insulated copper bus bar for phase, with neutral & earth bars,shrouds, cement spill protector,color coded inter- connecting wire sets,cable ties etc as applicable and fitted with the following accessories (1) One No. 40 A DP MCB (2) One No. 40 A DP RCCB 30 mA as incommer (3) 8 Nos 6 to 32 A SP MCB in a concealed/open manner as required at site. The MCCB/MCBs shall be IS/IEC certified | — | — | — | 21,456 | |
| — | 40.00 | — | — | ||
| Supply & fixing/concealing of ivory colour ISI marked PVC pipe 32 mm dia x 2/2.5 mm thick conforming to IS 9537 (PART-3), in a open manner complete with bend, Ts, etc with fixing hardware (Clamping to be done at a spacing not more than 75 cm on the building wall/roof) | — | — | — | 6,240 | |
| — | 20.00 | — | — | ||
| Supply & fixing/concealing of ivory colour ISI marked PVC pipe 25 mm dia x 2 mm thick conforming to IS 9537 (PART-3), complete with bend, Ts, Junction box etc with fixing hardware (Clamping to be done at a spacing not more than 75 cm on building wall where ever applicable) | — | — | — | 1,800 | |
| — | 20.00 | — | — | ||
| Supply & drawing of PVC insulated FRLS copper cable of 16.0sq.mm four runs & 16 sq mm one run as earth wire conforming to IS 694, through PVC conduit mentioned including termination in a standard manner as required at site | — | — | — | 13,660 | |
| — | 20.00 | — | — | ||
| Supply & drawing of PVC insulated FRLS copper cable of 4 sq.mm two runs & 4 sq. mm one run(green colour) as earth wire conforming to IS 694, through already erected PVC conduit including termination in a standard manner as required at site | — | — | — | 3,900 | |
| — | 4.00 | — | — | ||
| Supply, errection, testing and commissioning of Vertical open well submersible pump set water cooled & water lubricated and capable of discharging 2200 - 1000 LPM of water at a head range of 18 to 44 M and suitable on operation on 3 Phase 415 volt AC supply of standard make with warranty 1 year (20 HP, 100 mm Outlet) including suitable rope for erection of pump | — | — | — | 4,34,180 | |
| — | 1.00 | — | — | ||
| Supply,erection, testing and commissioning of Automatic Power Factor Correction Pannel 100 KVAR, 415 V, 3 Phase.( Rating of 4 (20 kVAr) + 1 (10 kVAr) + 1 (5 kVAr) + 1 (3 kVAr) + 1 (2 kVAr)) | — | — | — | 2,39,820 | |
| — | 1.00 | — | — | ||
| Supply and fixing and commissioning of IS/IEC certified 1 No. 16/20A DP MCB in metal enclosure (for fetching of supply with 16 sq mm cable LTUG cable for street light) | — | — | — | 1,953 | |
| — | 1.00 | — | — | ||
| Supply & fixing of SMC box of size 350x 270 x 200 mm approx ( Sintex GSJB 3527 or similar) fitted with Two Nos, 16 A 2 pole contactor and one No. mechanical quartz clock timer switch with cycle duration of 24 hrs working in 230 V 50Hz AC supply with testing and commissioning of street lights. | — | — | — | 7,372 | |
| — | 5.00 | — | — | ||
| Supply and errection of 4 M high galvanised octogonal pole as per Specification NoV/E.SPEC/284(R1) with 70 mm top dia, 130 mm bottom dia, 3mm thick sheet and 200 x 200 x 10 mm base plate with 4 Nos. 20mm dia and 450 mm long GI foundation bolts including 1 No. 600 mm long single arm GI bracket | — | — | — | 91,105 | |
| — | 1.25 | — | — | ||
| Design and casting of M-15 RCC foundation with 8mm steel rods reinforcement to octogonal pole complete with materials. | — | — | — | 22,775 | |
| — | 5.00 | — | — | ||
| Supply and fixing of 1 No. 16A fuse unit, 1 No. 20 A 4 way SMC connector in 5 mm thick SMC sheet in side the octagonal pole with suitable fixing hardware | — | — | — | 3,385 | |
| — | 4.00 | — | — | ||
| Supply, errection, testing and commissioning of Vertical open well submersible pump set water cooled & water lubricated and capable of discharging 2200 - 1000 LPM of water at a head range of 18 to 44 M and suitable on operation on 3 Phase 415 volt AC supply of standard make with warranty 1 year (20 HP, 100 mm Outlet) including suitable rope for erection of pump | — | — | — | 4,34,180 | |
| — | 5.00 | — | — | ||
| Supply & fixing of LED street light fitting 36 watts complete with driver assembly, pressure die cast aluminium housing, toughened glass cover conforming to IP 66 protection including supply connection with replacement warranty period of 5 years | — | — | — | 13,500 | |
| — | 5.00 | — | — | ||
| Supply & wiring to /street light luminaire points through octagonal pole with 3 core 1.5 sq. mm PVC insulated Cu wire . | — | — | — | 2,895 | |
| — | 250.00 | — | — | ||
| Supply and laying of 8 SWG GI wire and termination on either end as required at site | — | — | — | 6,000 | |
| — | 2.00 | — | — | ||
| Supply,erection, testing and commissioning of 2 Nos. of plate earthing arrangements including inter connection of the earth susing copper strip. Each earthing arrangement shall be as per Drg. No.V/E/02B/19-20.(Each set consists of 2 Nos. of such earthing arrangements duly interconnected by copper strip) | — | — | — | 1,11,000 | |
| — | 125.00 | — | — | ||
| Supply and laying/fixing of GI earth strip of size 25X3 mm and termination as required at site | — | — | — | 17,500 | |
| — | 22.00 | — | — | ||
| Provision of pipe earthing arrangements as per drg No.V/E.29/2025-26 | — | — | — | 1,36,774 | |
| — | 25.00 | — | — | ||
| Modification of exhaust pipe of DG set by fabrication, supply and installation of 5" MS pipe | — | — | — | 1,95,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument.pdf
ATTACHMENT
Plateearthing.pdf
ATTACHMENT
DrgV-E-29-25-26-LTEARTHING.pdf
ATTACHMENT
Outdoorsupplybunk.pdf
ATTACHMENT
Outdoorsupplybunk160A.pdf
ATTACHMENT
Indoorsupplybunk.pdf
ATTACHMENT
Cubiclepanel.pdf
ATTACHMENT
Cubiclepanelboard250A.pdf
ATTACHMENT
Cubiclepanel630A.pdf
ATTACHMENT
Specification for Octagonal pole
ATTACHMENT
Spec.284R1GALVANISEDOCTAGONALPOLES4M-Copy.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .