Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.9 LAccepted-AOC | 1 | Accepted-AOC LOWEST QUOTER | |
| 2 | Rejected-Technical D S ELECTRICALS D S MANDIRAM SREEVARAHAM VALLAKADAVU P O TRIVANDRUM | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | - | Rejected-Technical highest |
Tender Value
Refer Docs
EMD Value
₹9,720
Closing Date
12 Aug 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER ELECTRICAL DIVISION TDB
EXECUTIVE ENGINEER OFFICE,ELECTRICAL DIVISION,TRAVANCORE DEVASWOM BOARD,CHENGANNUR
Electrification of the newly constructed dialysis center at Old Danalekshmi bank Nanthancode.
2024_TDB_684955_1
TDB/EEE/ET-58/2024-25
Open Tender
Electrical Works
Item Rate
21 days
NANTHANCODE
Please refer Tender documents.
4 documents required · 4 mandatory
₹917
₹9,720
19 Nov 2024
9 Aug 2024
13 Aug 2024
9 Aug 2024
12 Aug 2024
9 Aug 2024
Amount
APPENDIX A: Electrification of the newly constructed dialysis center at Old Dhanlaxmi bank, Nanthencode
Dismantling and removing the existing old and damaged electrical installations and stacking carefully.-Labour Engaged:Wireman
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
Single Control light point with 6A, plate ceiling rose - Short point
Single control light point without ceiling rose - Short point
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
Independent plug - Short point
Supplying and fixing suitable size GI box with modular plate and cover in FRLS on to surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required:1200 mm 1X20W LED Lamp with box type fixture
Supplying and fixing of Angle/straight batten holder with box, 200 mm PVC shade 12 W LED bulb fixing on and giving connection.
Supply and fixing 24W LED Square Panel Light (Havells/Equivalent) with all accessories including connections etc as required
Supply , installation, testing and commissioning of 400 mm wall mounting fan 5 leaf policab/Equivalent make complete with all accessories including connections etc as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required:25 mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required : 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required: 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Earthing with GI earth pipe 2.5meter long 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe, etc. with charcoal/coke and salt, as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required :3.15 mm copper conductor ( 10 SWG)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) : 4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.:63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supply and fixing 5Amps to 32 Amps rating 240/415V, ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required. Single pole
4 way (8 + 12) double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
APPENDIX B: Installation of 2.0 Ton split Air Conditioner to the newly constructed dialysis center at Old Dhanlaxmi bank, Nanthencode
Supply, installation, testing and commissioning of Split Air-Conditioner and allied accessories with following configuration
Daikin/Blue star/voltas/carrier - 1.8 Ton 5 Star inverter Air Conditioners R32 refrigerant 100% Copper
5 kv Stabilizer working Voltage Range (175V -275V)
Outdoor Unit Stand with anti powder coated type Capacity – 1.0 TR to 2.0 TR
Supply and fixing of 25mm PVC Drain Pipe along with requires accessories
Supply and providing 10mm thick size soft drawn Copper Pipe
Supply and fixing of power cable
Unit Installation Charge
D SURESH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .