Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC 3RD FLOOR BNCCI HOUSE 23 R N MUKHERJEE ROAD KOLKATA 1 | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC Due to lowest. | |
| 2 | L2₹3.9 L+₹9,000 (2.33%)Rejected-Finance | L2 | Rejected-Finance Due to 2nd lowest. | |
| 3 | L3₹4.0 L+₹12,250 (3.18%)Rejected-Finance | L3 | Rejected-Finance Due to 3rd lowest. |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
8 Dec 2020, 6:00 pmClosed
EE_PED_PWD
RANCHI ROAD_PURULIA
Supply _Installation_ testing and Commissioning of 3 phase 25 KVA DG set for emergency power supply at Ajodhya Youth Hostel under Baghmundi Block in the District of Purulia
2020_WBPWD_306310_1
WBPWD/EE/PED/NIQ35_2nd Call /2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,000
11 Mar 2021
25 Nov 2020
11 Dec 2020
26 Nov 2020
8 Dec 2020
26 Nov 2020
Amount
SUB-HEAD 1--SUPPLY,DELIVERY,COMMISIONING & TESTING OF DG SET Supply,delivery at site on foundation,commissioning and testing of 25KVA,415 V,50 Hz,3 phase new DG set, comprising of Engine,alternator,separate AMF panel,base frame,Fuel tank,Battery,CPCB-II approved Engine & Acoustic Enclosure having following specifications:-
Engine
Make-Ashok Leyland/Kirloskar/Cummins
Engine type:-4 Stroke Diesel Engine
Rated Output:34.2 BHP or Higher
Duty: Prime
Cooling: Liquid Cooled(EG Compleat 50:50)
Cylinder: 2(In line)
Aspiration:-Turbocharged,Charge Air cooled
Type of Governer: Electronic
Fuel Tank Capacity: Minimum Capacity 75 ltr
Fuel Consumption at 75 % rated Load with Radiator or fan: 4.8 Ltr/Hr or less
Fuel Consumption at 100 % rated Load with Radiator or fan: 5.5Ltr/Hr or less
Overload Capacity :10% overload for one hour for every 12 hours continuious running running at full load or better
Engine instrument panel : Consisting of starting switch with key,Lube oil indicator,RPM indicator and hour meter.
Safety Controls:Emergency Stop,Low Lube oil pressure warning/shutdown, Warning /Shutdown,sensor failure indicator,Engine overspeed indicator,Battery charging and low battery indicator.Exhaust Silencer:Residential type
Starting system:12 V starting system complete with starter motor,charging alternator with rectifier and Cut out as per manufacturer standard.
Battery:Lead Acid,Low maintenance or SMF and conforming to relevant IS Specification with low/high battery voltage and weak Battery warning.
ALTERNATOR
Make:Stamford(CGT)/Leroy Somer/Ashok Leyland/Kirloskar/Cummins
Rating:415 V,3 phase,50Hz, 25 KVA,1500 rpm
Type:-Brushless,screen protected,Revolving field ,self excited and self regulated
Insulation: Class H
Protection: screen protected drip proof with Min IP-23 degree of protection
Voltage regulation (Max):+1 %
Winding connection:-Stator-double layer lap, Rotor-Dynamically Balanced
Total Distortion factor: No load<1.5 %, Non distoring balanced linear load<5%
Total Harmonic distortion in output waveform:No load<1.5 %, Non distoring balanced linear load<5%
AMF PANEL
Cubical type floor mounted AMF panel made 16 SWG sheet steel,duly pretrated,powder coated painted and acsthetically finished ,suitable for controlling of 25 KVA DG set having following specifications/features.
i)_____A, EDO type ACB with O/L,S/C,E/F protection and microproceessor based protection release,U/V release etc.--2sets
ii) In Built By-Pass switch for rated capacity
iii)On-delay timer for load change over
iv)On-delay timer for engine shut OFF.
v)Engine On-OFF switch(Push Button type)
vii)Minimum five number indicating lamps to indicate "mains ON", "load on mains","set running","load ion DG sets" and "battery charger On".
viii)Audio Visual alarm for "Low Lubricating oil pressure","High water temperatur",Start failure, and "DG overload"
x)Microprocessor based relay with composite meter for digital display of following.
Generator Voltage/AC Mains voltage:415 V
Generator current in all phases:35 A
Frequency:50 Hz
Power factor: 0.8(lagging)
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals,service due indications.
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load of DG within 15(fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator ,mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
i) Rate should be quoted inclusive of all applicable taxes and duty etc.
ii) All materials,equipments & aceessories must conform to relevent IS/IEC specifications.The DG set to be supplied must be from the authorized OEM of the respective Engine manufacturer.
iii)Necessary manufacturer's test certificate for Deisel Engine,Alternator etc. will have to submit in triplicate copy during delivery of the equipment.
iv) Copy of "type approval certificate " and Certificate of "COP" must be produced at the time of delivery issued from competant Authority(as per CPCB-II).
v)Circuit diagram for AMF panel must be submitted from the Manufacturer/OEM.
vi) Efficiency not less than 90%
vii) The entire set must be warranted atleast 18 months from the date of Delivery/12 months/5000 Hrs from the date of Commissioning whichever is earlier.However Engine & Alternator should be warranted of 2 year/5000 hrs whichever is earlier.
Mega Enterprise
D. D. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .