| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC 32 1089 KALAMASSERY CHANGAMPUZHA NAGAR COCHIN ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | ₹3.5 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹3.5 Cr+₹4.7 L (1.37%)Rejected-Finance 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | ₹3.5 Cr+₹4.7 L (1.37%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹3.8 Cr+₹28.5 L (8.21%)Rejected-Finance | ₹3.8 Cr+₹28.5 L (8.21%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹4.3 Cr+₹85.2 L (24.6%)Rejected-Finance | ₹4.3 Cr+₹85.2 L (24.6%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹4.9 Cr+₹1.4 Cr (40.2%)Rejected-Finance | ₹4.9 Cr+₹1.4 Cr (40.2%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹4 Cr
EMD Value
₹8 L
Closing Date
22 Apr 2025, 4:00 pmClosed
Managing Director, CIAL
Managing Director, Cochin International Airport Ltd Nedumbassery Kochi Airport PO 693111
Electrical works for the construction of hospitality and sporting facilities at CIAL Golf Club.
2025_CIAL_748686_1
CIAL/ELE/393/ET09
Open Tender
Electrical Works
Item Rate
365 days
Cochin International Airport Golf Club
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,950
₹8 L
CIAL
17 Jul 2025
11 Mar 2025
23 Apr 2025
11 Mar 2025
22 Apr 2025
28 Mar 2025
11 Mar 2025 - 24 Mar 2025
26 Mar 2025
Amount
SUB HEAD I - HT ELECTRICAL EQUIPMENTS-HT PANELS,TRANSFORMER & DIESEL GENERATOR'S
11KV ,800A,25 KA INDOOR TYPE 4 PANEL VCB BOARD (1 NO. I/C + 3 NOS. O/G) Fabrication and supply of 11KV, 800A, 25kA (3-sec withstand), electrically operated, draw-out Type, 4 panel indoor VCB panel with 800A copper busbars. Enclosure fabricated from 14-gauge CRCA sheet, pre-treated via seven-tank process (degreasing, phosphating, passivation) and powder-coated in approved RAL shade. Incomer- 1 No VCB: 11kV, 800A, 25kA (3 sec withstand) breaking capacity, draw-out type, electrically operated spring mechanism (230V AC) with motorized charging. PT: 11kV/√3 : 110V/√3, 50VA, Class 0.5 CT: 300/5A dual-core:Core 1: 15VA, Class 0.2S .Core 2: 5VA, Class 5P10. Controls: Numerical protection relay with RS485/Modbus communication port, 12-window annunciator, bidirectional TOD meter, Voltmeters and Ammeters, multifunction meter (MFM), TNC switch, L/R switch, indication lamps as required as per technical specification & drawing Outgoings- 3 Nos- VCB: 11kV, 800A, 25 kA (3 sec withstand) breaking capacity, draw-out type, electrically operated spring mechanism (230V AC) with motorized charging. CT- Core 1:100/5A, 15VA Cl. 0.2S Core 2: 100/5, 5P10, 15VA, Controls: Numerical protection relay with RS485/Modbus communication port, 8-window annunciator, bidirectional TOD meter, Voltmeters and Ammeters, multifunction meter (MFM), TNC switch, L/R switch, indication lamps as required as per technical specification & drawing
Installation, Testing and commissioning of the above mentioned 4 panel VCB including transportation, loading/ unloading of panel, fixing, minor civil works, etc as required complete.
Supply of 30V DC Power supply with Suitably rated battery charger, 15 Nos. of 2 Volt, 200 AH, VRLA batteries with battery stand, DCDBs having sufficient outgoings with DC duty DP MCBs, Voltmeter, Ammeter, interconnections etc. as required (refer technical specification)
Erection, testing and commissioning of 30V DC Power supply with battery charger, 15 Nos. of 2 Volt, 200 AH, VRLA batteries with battery stand, DCDBs and all accessories including all interconnections and and termination of cables to various panels and fixing of DB as required.
750 KVA INDOOR TRANSFORMER Installation, testing and commissioning of 11KV/433V Indoor,dry type, Distribution Transformer, 750KVA 3 Phase, with HV cable box suitable for XLPE cable and LV busduct suitable for NCT and REF CT busbar trunking, with WTI, all other standard fittings and accessories conforming to IS 11171/85, IS 2026, IS 2099, IS 3639, IS 1248, and IS 5578. The work includes, loading, transportation and unloading of the transformer at the respective location bolting the units, checking all control and power cabling,calibration of all measuring instruments, precommissioning and all other checks required at the site as necessary
320kVA DIESEL GENERATOR Design, manufacture, assembly, testing at works, supply, erection, testing & commissioning at site as per specifications complete in all respect of DG Set of 320 KVA minimum capacity (prime)with the specifications mentioned below: Brushless type screen protected, 415 Volts, 3 phase 4 Wire, 50 Hz, 1500 RPM AC alternator with revolving field coupled with Radiator Cooled Diesel Engine complete with all accessories, like self starting device, fly wheel coupling with guard, V belts, cooling system, instrument panel comprising of switch with key, standard control panel, starting battery & battery charging device, safety control for lub oil pressure with tripping etc. The alternator insulation shall be class 'H' with temperature rise limited to Class 'F' value suitable to withstand tropical conditions and shall generally comply with BS 5514 and IS 10002. The engine should be turbocharged, air/liquid cooled with over load capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. DG Set shall be enclosed in an acoustic enclosure. The enclosure shall have provision of space required for inspection and minor maintenance. The enclosure hall have suitable number of lights for sufficient illumination, 24 Volt Lead Acid rechargeable battery set of adequate AH rating complete with metal batterystand, battery leads. The governer class shall be G2/A1 as per ISO 8528 part V, Lube oil change period shall not be less than 500 Hrs. Voltage dip shall not exceed 20%.Voltage built up shall not more than 10 sec. Fuel consumption shall be linear after 50% of load. 320 KVA DG Set with acoustic enclosure & standard accessories (For Detail Specifications Kindly See Technical Specifications). Emission rules should be as per CPCB IV+ standards. Further details regarding positioning of components shall be as per the instruction of Engineer In-charge.
Exhaust System for DG- 320KVA(minimum capacity) Suitable extension of exhaust pipe of dia 200mm for 320kVA (minimum capacity) DG, considering the site conditions as per requirement mentioned in the latest regulations of CIE- Kerala & CPCB. The exhaust pipe shall have a gooseneck shaped mechanical vent pipe on top,to prevent rainwater entry inside the generator.The exhaust pipe(conforming to IS:3589, amended up to date) shall be erected and suitably extended with sufficient diameter pipe, SS Bellows with flanges, gaskets, hardwares etc. also providing and fixing thermal insulation of exhaust pipeline of thickness 50 mm x density 100 kg/m3with embedded chicken wire mesh, cladding by 24 SWG aluminium sheets (upto the outerwall of the building) including the bends/ flanges therein, by fixing appropriate size steel screws and washers; cladding to be done in such a manner and workmanship that it shall protect direct entry of rain water into the insulation done; workmanship of work should be good to ensure proper finishing having regular diameter all over. The length of pipe left without thermal insulation shall be suitably painted by 2 coats of high heat resistant paint. Silencers and Horizontal runs shall be supported on spring supports. Vertical runs to have expansion bellows where length exceeds 25 M.
Exhaust System for DG- 320KVA(minimum capacity) Suitable extension of exhaust pipe of dia 250mm for 320kVA (minimum capacity) DG, considering the site conditions as per requirement mentioned in the latest regulations of CIE- Kerala & CPCB. The exhaust pipe shall have a gooseneck shaped mechanical vent pipe on top,to prevent rainwater entry inside the generator.The exhaust pipe(conforming to IS:3589, amended up to date) shall be erected and suitably extended with sufficient diameter pipe, SS Bellows with flanges, gaskets, hardwares etc. also providing and fixing thermal insulation of exhaust pipeline of thickness 50 mm x density 100 kg/m3with embedded chicken wire mesh, cladding by 24 SWG aluminium sheets (upto the outerwall of the building) including the bends/ flanges therein, by fixing appropriate size steel screws and washers; cladding to be done in such a manner and workmanship that it shall protect direct entry of rain water into the insulation done; workmanship of work should be good to ensure proper finishing having regular diameter all over. The length of pipe left without thermal insulation shall be suitably painted by 2 coats of high heat resistant paint. Silencers and Horizontal runs shall be supported on spring supports. Vertical runs to have expansion bellows where length exceeds 25 M.
Supply, installation, testing and commissioning of : Fuel tank fabricated out of MS Steel sheet (wall thickness 5mm)having a capacity of 1000L and having suitable cubical/cuboidal dimension and 30cmx30cm hinged metal cover on top as per site conditions. It shall have a level indicator provided with drain plug for drainage and air vent / breather and inlet and outlet connection with cleaning provision.
SUB HEAD II - BUS BAR TRUNKING SYSTEM
Supply of 1250A ,415V, 50 kA, 50Hz AC TPN Sandwich Aluminium Bus Duct with 100% neutral Bus made out of 14 SWG powder coated and painted extruded Aluminium IP54 enclosure, flexible end termination, fittings & accessories like elbows, offset sections, tees, reducers, adaptor boxes, flanges , flexible connections , expansion joints, ground strips , suitable supporting arrangement with metal suspenders/ brackets provision for fixing 2 runs of 25x6mm Cu earth strip throughout the length of busduct etc. as required complete. (The rate shall be quoted for running meter and the elbows, bends, adaptor boxes are also measured under running meter and the rate shall be inclusive all associated accessories. Refer drawing &Technical specification for more details,(From Transformer to MSB)
Installation, Testing and commissioning of 1250A ,415V, 50 kA, 50Hz AC TPN Sandwich Aluminium Bus Duct with 100% neutral Bus made out of 14 SWG powder coated and painted extruded Aluminium IP54 enclosure, flexible end termination, fittings & accessories like elbows, offset sections, tees, reducers, adaptor boxes, flanges , flexible connections , expansion joints, ground strips , suitable supporting arrangement with metal suspenders/ brackets provision for fixing 2 runs of 25x6mm Cu earth strip throughout the length of busduct etc. as required complete. (The rate shall be quoted for running meter and the elbows, bends, adaptor boxes are also measured under running meter and the rate shall be inclusive all associated accessories. Refer drawing &Technical specification for more details,(From Transformer to MSB)
SUB HEAD III - LT PANEL BOARDS
Installation, Testing and Commissioning of "MSB" including hoisting to the respective location including minor civil works assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "SSB-1" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification. Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "SSB-2" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "SSB-3" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification. Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "COTTAGE PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "RESTAURANT PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "CONVENTION HALL PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "CONVENTION HALL AC PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification. Any minor civil works for panel installation shall also be included.
Installation, Testing and Commissioning of "SPORTS COMPLEX PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "PUMP PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "APFC PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
SUBHEAD IV - HV CABLE JOINTING & END TERMINATION
Supplying and making outdoor cable end termination for 3C 300 sq. mm XLPE insluated aluminium conductor cable of 11 KV grade cable with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and making indoor cable end termination for 3C 300 sq. mm XLPE insluated aluminium conductor cable of 11 KV grade cable with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
SUB HEAD V - UPS
6kVA UPS Supply of 6kVA ups along with batteries and battery rack. The UPS shall comply with the following specifications Backup Time- 30mins , Output PF>0.9, Input voltage range: 140V -280V, with Isolation transformer, Output: 230V, THDi : ≤ 5%, Ambient Temperature: 0-40°C,IP20, Generator Compatibility,Pure sine wave, Battery over charge & under charge cut off, Bypass arrangement Static bypass switch and manual by pass switch, Indications: Digital indications of Input V & A, output V & A, Battery, charge, Temperature, Intelligent interface with LED/LCD LED/LCD Display, EN/IEC 620401, 620402, 620403 complaint Battery banks for the necessary backup time shall be provided with powder coated CRCA cabinet and interconnecting cables. The UPS shall be capable of working in parallel redundant mode,
Installation, Testing and Commissioning of 6kVA UPS System including hoisting to the respective location, assembling of batterys, connection to coupling panel, lining up, bolting the units, checking all the control wirings, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of 2x 6kVA UPS System for parallel operation including hoisting to the respective location, assembling of batterys, connection to coupling panel, lining up, bolting the units, checking all the control wirings, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification. The cost of supporting parallel kit shall be included.
2kVA UPS Supply of 2 x 2kVA ups along with batteries and battery rack. The UPS shall comply with the following specifications Backup Time- 30mins , Output PF>0.9, Input voltage range: 140V -280V, with Isolation transformer, Output: 230V, THDi : ≤ 5%, Ambient Temperature: 0-40°C,IP20, Generator Compatibility,Pure sine wave, Battery over charge & under charge cut off, Bypass arrangement Static bypass switch and manual by pass switch, Indications: Digital indications of Input V & A, output V & A, Battery, charge, Temperature, Intelligent interface with LED/LCD LED/LCD Display, EN/IEC 620401, 620402, 620403 complaint Battery banks for the necessary backup time shall be provided with powder coated CRCA cabinet and interconnecting cables. The UPS shall be compatiable for parallel operation.
Installation, Testing and Commissioning of 2 x 2kVA UPS System for parallel operation including hoisting to the respective location, assembling of batterys, connection to coupling panel, lining up, bolting the units, checking all the control wirings, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification. The cost of supporting parallel kit shall be included.
SUB HEAD VI - CABLES
Supply of 1.1KV grade, 4-core, 25 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 4-core, 16 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 4-core, 10 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 4-core, 6 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 4-core, 4 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1
Supply of 1.1KV grade, 4-core, 2.5 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1)
Supply of 1.1KV grade, 3.5-core, 400 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3.5-core, 300 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3.5-core, 240 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3.5-core, 185 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3.5-core, 120 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1
Supply of 1.1KV grade, 3.5-core, 95 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3.5-core, 70 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1
Supply of 1.1KV grade, 3.5-core, 50 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3.5-core, 35 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 11KV grade, 3-core, 300 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1).
Supply of 1.1KV grade, 3-core, 4 sq.mm aluminum conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1)
Supply of 1.1KV grade, 12-core, 1.5 sq.mm copper conductor, XLPE insulated, PVC sheathed, armoured power cable as per IS:7098 (Part-1)
Supplying of PVC/XLPE insulated and PVC sheathed armoured power cable of 1.1 KV grade of following sizes 12-core, 10 sq.mm. Cu Armoured XLPE insulated cable
SUB HEAD VII - CABLE LAYING
Laying of one number PVC insulated and PVC sheathed armoured power cable Upto 35 sq. mm of 1.1kV grade of the following sizes in ground including excavation, sand cushioning , providing protective covering and refilling the trench etc. as required.
Laying of one number PVC insulated and PVC sheathed armoured power cable Above 35 sq. mm and upto 95 sq. mm of 1.1kV grade of the following sizes in ground including excavation, sand cushioning , providing protective covering and refilling the trench etc. as required.
Laying of one number PVC insulated and PVC sheathed armoured power cable Above 95 sq. mm and upto 185 sq. mm of 1.1kV grade of the following sizes in ground including excavation, sand cushioning, providing protective covering and refilling the trench etc. as required.
Laying of one number PVC insulated and PVC sheathed armoured power cable Above 185 sq. mm and upto 400 sq. mm of 1.1kV grade of the following sizes in ground including excavation, sand cushioning, providing protective covering and refilling the trench etc. as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable Upto 35 sq. mm of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable Above 35 sq. mm and upto 95 sq. mm of 1.1 KV grade direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable Above 95 sq. mm and upto 185 sq. mm of 1.1 KV grade direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable Above 185 sq. mm and upto 400 sq. mm of 1.1 KV grade direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/RCC/Stone Ware/Hume pipe/trench/surface including breaking, grouting, finishing and all necessary civil work as required as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/RCC/Stone Ware/Hume pipe/trench/surface as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/RCC/Stone Ware/Hume pipe/trench/surface including breaking, grouting, finishing and all necessary civil work as required as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/RCC/Stone Ware/Hume pipe/trench/surface including breaking, grouting, finishing and all necessary civil work as required as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of 1.1KV grade PVC/XLPE insulated and PVC sheathed armoured power cable in existing GI/MS cable tray, including breaking, grouting, finishing and all necessary civil work including breaking, grouting, finishing and all necessary civil work as required as required - Up to 35 sq.mm size with 1mm thick saddle clamping.
Laying and fixing of 1.1KV grade PVC/XLPE insulated and PVC sheathed armoured power cable in existing GI/MS cable tray, including breaking, grouting, finishing and all necessary civil work as required - Above 35 sq.mm and up to 95 sq.mm size with 25x3mm MS flat clamp.
Laying and fixing of 1.1KV grade PVC/XLPE insulated and PVC sheathed armoured power cable in existing GI/MS cable tray, including breaking, grouting, finishing and all necessary civil work as required - Above 95 sq.mm and up to 185 sq.mm size with 25/40x3mm MS flat clamp.
Laying and fixing of 1.1KV grade PVC/XLPE insulated and PVC sheathed armoured power cable in existing GI/MS cable tray, including breaking, grouting, finishing and all necessary civil work as required - Above 185 sq.mm and up to 400 sq.mm size with 40x3mm MS flat clamp.
SUB HEAD VIII - MV CABLE END TERMINATIONS
Supply and making end termination of 1.1KV grade, 3.5-core, 35 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 50 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 70 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 95 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 120 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 185 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required
Supply and making end termination of 1.1KV grade, 3.5-core, 240 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 300 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3.5-core, 400 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 4-core, 10 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 4-core, 16 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 4-core, 25 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 4-core, 6 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 3-core, 4 sq.mm aluminum conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and aluminum lugs, as required.
Supply and making end termination of 1.1KV grade, 12-core, 1.5 sq.mm copper conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and copper lugs, as required.
Supply and making end termination of 1.1KV grade, 3-core, 10 sq.mm copper conductor, PVC/XLPE insulated, PVC sheathed, armoured cable with brass compression gland and copper lugs, as required.
SUB HEAD IX - EARTHING
GI PIPE EARTHING STATIONS Providing and making earthing with hot dip galvanized iron pipe 4.5 meter long, 40mm diameter (medium class), including excavation, providing and laying alternate layers of charcoal/coke and salt, construction of inspection chamber in brick masonry with plastering, CI cover with frame of size 300mm x 300mm (medium duty) complete with locking arrangement, and providing GI watering pipe with GI funnel and wire mesh including all required civil works, materials, and accessories as per latest CPWD/IS specifications and standards, as required.
CI PLATE EARTHING STATIONS Supply of all materials and providing plate earth station with 1200 x 1200 x 12.5 mm. C.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, terminal Electrodes etc., excavation in all classes of soil, filling with alternate layers of charcoal and salt and back filling ,construction of Earth pit Inspection Chamber and Heavy duty C.I. Chequered plate for Earth pit Inspection Chamber cover. The Earthing Station should conform to IS 3043/1987.
Cu PLATE EARTHING STATIONS Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
EARTHING CONDUCTORS Supply, installation, testing, and commissioning of 50mm x 6mm GI strip earthing conductor as per IS standards, including straightening, shaping, laying underground/on cable tray/in cement concrete trench, providing necessary support clamps, making joints with required hardwares and accessories, termination to equipment/earthing stations complete as per specifications, as required.
Installation, Testing and commissioning of 50mm x 6mm GI strip earthing conductor as per IS standards, including straightening, shaping, laying underground/on cable tray/in cement concrete trench, providing necessary support clamps, making joints with required hardwares and accessories, termination to equipment/earthing stations complete as per specifications, as required.
Supply, installation, testing, and commissioning of 50mm x 10mm GI strip earthing conductor as per IS standards, including straightening, shaping, laying underground/on cable tray/in cement concrete trench, providing necessary support clamps, making joints with required hardwares and accessories, termination to equipment/earthing stations complete as per specifications, as required.
Installation, Testing and commissioning of 50mm x 10mm GI strip earthing conductor as per IS standards, including straightening, shaping, laying underground/on cable tray/in cement concrete trench, providing necessary support clamps, making joints with required hardwares and accessories, termination to equipment/earthing stations complete as per specifications, as required.
COPPER CONDUCTORS Supply of following sizes of copper conductor. 25X3mm copper flat
Straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc. 25X3mm copper flat
Supply of following sizes of copper/hot dipped galvanized iron conductor. No.10 SWG Cu
Supply of following sizes of copper/hot dipped galvanized iron conductor. No.6 SWG Cu
Supply of following sizes of copper/hot dipped galvanized iron conductor. No.4 SWG Cu
Straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc. No.10 SWG Cu
Straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc. No.6 SWG Cu
Straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc. No.4 SWG Cu
SUB HEAD X - CABLE TRAY
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, including bends, tees etc, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 2 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, including bends, tees etc, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, including bends, tees etc, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2 mm thickness
Supplying and installing following size of Ladder type Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) in convenient sections, joined with connectors, including bends, tees etc, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2 mm thickness
Supply, fabrication. erection and commissioning of chequered plates, vertical and horizontal type cable trays and cable supports fabricated out of MS Angles and MS flats with sufficient width annd spacing between successive cross members and supported at adequate spacing. They shall be painted with two coats of Zinc chromate primer and two coats of enamel. It also includes Tees/ angles/channels etc for fixing in concrete trenches/on floor/ceiling/wall and as required
SUB HEAD XI - SF SP/TP MCB DB's & VDB's
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6- 32A Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6- 32A Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required 40 A DP Isolator
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A FP Isolator
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A FP Isolator
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A FP Isolator
Supplying and fixing of 40 A FP two way with centre off changeover switch for (pumps), 415 V AC, two way with centre off changeover switch in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Installation, Testing and commissioning of 40 A FP two way with centre off changeover switch for (pumps), 415 V AC, two way with centre off changeover switch in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way (4 + 24), Double door
Installation,testing and commissioning of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way (4 + 24), Double door
Supply of following rating, double pole, (single phase and neutral), 240 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 30 mA. 25A 30mA DP RCBO
Installation,testing and commissioning of following rating, double pole, (single phase and neutral), 240 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A 30mA DP RCBO
Supply of following rating, double pole, (single phase and neutral), 240 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 30 mA. 32A 30mA DP RCBO
Installation,testing and commissioning of following rating, double pole, (single phase and neutral), 240 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A 30mA DP RCBO
Supplying of following rating, four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 30 mA. 32A 30mA 4P RCBO (TPN DB's Incomer)
Installation,testing and commissioning of following rating, four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A 30mA 4P RCBO (TPN DB's Incomer)
Supply of following rating, four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 100 mA . 40A 100mA 4P RCBO
Installation,testing and commissioning of following rating, four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A 100mA 4P RCBO
Supplying and fixing of 63A 100mA 4P RCBO (VDB's Incomer) four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Installation, Testing and commissioning of 63A 100mA 4P RCBO (VDB's Incomer) four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying of 3 Module (100x150x96) indoor-polystyrene AK03 Thermoplastic enclosure on surface complete with connections, testing and commissioning etc. as required.
Installation,testing and commissioning of 3 Module (100x150x96) indoor-polystyrene AK03 Thermoplastic enclosure on surface complete with connections, testing and commissioning etc. as required.
Supplying of 5 Module (125x200x122) indoor-polystyrene AK05 Thermoplastic enclosure on surface complete with connections, testing and commissioning etc. as required.
Installation,testing and commissioning of 5 Module (125x200x122) indoor-polystyrene AK05 Thermoplastic enclosure on surface complete with connections, testing and commissioning etc. as required.
Supply of following rating, double pole 240 V Modular contactor in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A 2 NO contactor
Installation,testing and commissioning of rating, double pole 240 V Modular contactor in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A 2 NO contactor
Supply of 16A 230 V AC single phase card operated key fob switch with time delay fixed along with 25A double pole contactor(NO) complete with key fob for rooms.
Installation,testing and commissioning of 16A 230 V AC single phase card operated key fob switch with time delay fixed along with 25A double pole contactor(NO) complete with key fob for rooms.
Supply of DND and MMR indicator internal and external module with bell push in existing metal box ,plate and giving connections as required
Installation,testing and commissioning of DND and MMR indicator internal and external module with bell push in existing metal box ,plate and giving connections as required
SUB HEAD XI - INTERNAL ELECTRICAL INTSTALLATIONS & WIRING
Point wiring in PVC conduit with modular type switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Twin control point wiring in PVC conduit ,with modular type switch: Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium gauge PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium gauge PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium gauge PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying of following modular switch/ socket but excluding modular plate. 5/6 A switch
Supplying of following modular switch/ socket but excluding modular plate. 3 pin 5/6 A socket outlet
Supplying of following modular switch/ socket but excluding modular plate. 15/16 A switch
Supplying of following modular switch/ socket but excluding modular plate. 6 pin 15/16 A socket outlet
Supplying of following modular switch/ socket but excluding modular plate. Telephone socket outlet
Supplying of following modular switch/ socket but excluding modular plate. TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. 4 Module (125mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing type 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connection, painting etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/door etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required.
Wiring for group controlled (looped) light point/fan point/exhaustfan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supply of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. USB charger 3.1A type A & C with Euro sockets-2 Module
Installation,testing and commissioning of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. USB charger 3.1A type A & C with Euro sockets-2 Module
Supply of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Shaver socket 230V/120-230V with earth connector-4 Module
Installation,testing and commissioning of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Shaver socket 230V/120-230V with earth connector-4 Module
Supply of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Information socket-category 6 UTP -2 Module
Installation,testing and commissioning of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Information socket-category 6 UTP -2 Module
Supply of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 20A 1way DP Switch with indicator-2 Module
Fxing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 20A 1way DP Switch with indicator-2 Module
Supplying of following modular switch/ socket but excluding modular plate. 25A Socket-2 Module
Fxing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 25A Socket-2 Module
SUB HEAD XIII - SUPPLY AND INSTALLATION OF INTERNAL LIGHT FITTINGS & FANS
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Installation, testing, and commissioning of recess-mounted LED luminaires, including integration into ceilings/walls with appropriate housing, electrical connections, and alignment to specified standards
Installation, testing, and commissioning of surface-mounted or suspended LED luminaires, including securing to structural supports, electrical connections, and compliance with safety/performance standards.
Installation, testing, and commissioning of LED drivers/power supplies, including surge protection, voltage regulation, and integration with lighting systems as per electrical safety standards.
Installation,testing and commissioning of 5 Watt per meter strip light having burning hours of 50,000 hrs. It should have min 60 LED's per meter. Should work on 24V driver supply.Should have LED efficacy of min 80 lm/w.
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation,testing & commissioning of 1200mm sweep (White) 5 star rated BLDC ceiling fan without regulator including wiring the down rod of std.length ( upto 30cms) with 1.5 Sqmm PVC insulated copper conductor, single core cable etc as required.
SUB HEAD XIV - STREET LIGHTS
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (Feeder pillar outgoings and street light control)
Supply of 60W LED Street light luminaire (IP66- NABL accrediated third party lab test report shall submitted), BIS certified with a flat toughened glass protector (IK08- NABL accrediated third party lab test report shall submitted),body of high pressure die cast aluminium. Several optical options providing excellent photometry to optimally cater to all kinds of road configurations. Overall luminous efficiency of 120lm/W (LM 79 test report from NABL accrediated third party lab test report shall submitted)at correlated colour temperature (CCT) of 3000K , colour rendering index (CRI) 70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV. LM80 test report shall be submitted.
Installation, Testing and commissioning of 60W LED Street light luminaire (IP66- NABL accrediated third party lab test report shall submitted), BIS certified with a flat toughened glass protector (IK08- NABL accrediated third party lab test report shall submitted),body of high pressure die cast aluminium. Several optical options providing excellent photometry to optimally cater to all kinds of road configurations. Overall luminous efficiency of 120lm/W (LM 79 test report from NABL accrediated third party lab test report shall submitted)at correlated colour temperature (CCT) of 3000K , colour rendering index (CRI) 70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV. LM80 test report shall be submitted.
Supply of 6Mtr height decorative pole made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 5000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised. It shall also include the Supply of Hot Dip Galvanised single arm bracket having length 500mm, galvanised to minimum 65micron thereafter treated with two coats of epoxy primer and PU Painted to 100micron, tightned to the pole top with stainless steel grub screws to mount the luminarie
Supply of 6Mtr height decorative pole made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 5000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted)Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised. It shall also include the supply of Hot Dip Galvanised double arm bracket having length 500mm, galvanised to minimum 65micron thereafter treated with two coats of epoxy primer and PU Painted to 100micron, tightned to the pole top with stainless steel grub screws to mount the luminaries.
Installation, Testing and commissioning of 6Mtr height decorative pole (with single arm/double arm bracket) made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 5000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised.
Supply of 30W LED Street light luminaire (IP66- NABL accrediated third party lab test report shall submitted), BIS certified with a flat toughened glass protector (IK08- NABL accrediated third party lab test report shall submitted),body of high pressure die cast aluminium. Several optical options providing excellent photometry to optimally cater to all kinds of road configurations. Overall luminous efficiency of 120lm/W (LM 79 test report from NABL accrediated third party lab test report shall submitted)at correlated colour temperature (CCT) of 3000K , colour rendering index (CRI) 70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV. LM80 test report shall be submitted.
Installation, Testing and commissioning of 30W LED Street light luminaire (IP66- NABL accrediated third party lab test report shall submitted), BIS certified with a flat toughened glass protector (IK08- NABL accrediated third party lab test report shall submitted),body of high pressure die cast aluminium. Several optical options providing excellent photometry to optimally cater to all kinds of road configurations. Overall luminous efficiency of 120lm/W (LM 79 test report from NABL accrediated third party lab test report shall submitted)at correlated colour temperature (CCT) of 3000K , colour rendering index (CRI) 70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV. LM80 test report shall be submitted.
Supply of 5Mtr height decorative pole made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 4000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised. It shall also include the supply of Hot Dip Galvanised single arm bracket having length 500mm, galvanised to minimum 65micron thereafter treated with two coats of epoxy primer and PU Painted to 100micron, tightned to the pole top with stainless steel grub screws to mount the luminaries.
Supply of 5Mtr height decorative pole made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 4000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised. It shall also include the supply of Hot Dip Galvanised double arm bracket having length 500mm, galvanised to minimum 65micron thereafter treated with two coats of epoxy primer and PU Painted to 100micron, tightned to the pole top with stainless steel grub screws to mount the luminaries.
Installation, Testing and commissioning of 5Mtr height decorative pole made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm with double/single arm bracket. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 4000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised.
Supply of 5Mtr height decorative pole suitable for Post top fittings made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 4000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised.
Installation, Testing and commissioning of 5Mtr height decorative pole suitable for post top fittings made of mild steel/steel tube complied with IS1161/IS 3601, minimum thickness of 3mm. The pole shall have two section, base section having base dia of 140mm with a length of 1000mm and upper section having dia of 76mm with 4000mm length. Pole shall be mounted on square base plate of dimensions 240*240*14 mm thickness. The base section of Pole shall have an in-built junction box. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. (Chemical & mechanical test report shall submitted) Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before traeting with primer. After galvanisation structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 100 microns (test report of micron thickness shall submitted). The pole shall be designed as per EN40 for withstand basic wind speed of 169kmph The complete structure should be hot dip galvanised.
Supply of 35W Decorative LED post-top luminaire in tapered form with a body of cast aluminium, canopy of corrosion-resistant aluminium and a diffuser of high impact-resistant clear PMMA (IK07) fixed on to the body, IP65 optical and control gear compartments. Highly efficient UV and temperature-resistant lens systems in 4-fold configurations for symmetric, wide light intensity distribution providing excellent photometry to optimally cater to different applications. Suitable for vertical mounting for 76mm diameter pipe. Overall system efficiency of 100lm/W or 110lm/W at correlated colour temperature (CCT) of 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of4kV and an additional surge protection device (SPD) of 10 kV.
Installation, Testing and commissioning of 35W Decorative LED post-top luminaire in tapered form with a body of cast aluminium, canopy of corrosion-resistant aluminium and a diffuser of high impact-resistant clear PMMA (IK07) fixed on to the body, IP65 optical and control gear compartments. Highly efficient UV and temperature-resistant lens systems in 4-fold configurations for symmetric, wide light intensity distribution providing excellent photometry to optimally cater to different applications. Suitable for vertical mounting for 76mm diameter pipe. Overall system efficiency of 100lm/W or 110lm/W at correlated colour temperature (CCT) of 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of4kV and an additional surge protection device (SPD) of 10 kV.
Supply of 15W Bullet shaped LED Bollard, BIS certified with a pressure die cast aluminium base and a protector made of LDPE (Low Density Polyethylene) having separate IP66 optical & control gear compartments, impact resistance of IK10, suitable for surface mounting. Excellent photometry to maximise the spacing between the bollards. Suitable for on-ground mounting on 3xM10 bolts on 230mm PCD. System power of 15W, correlated colour temperature (CCT) of 4000K (optional 3000K & 5700K), colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV.
Installation, Testing and commissioning of 15W Bullet shaped LED Bollard, BIS certified with a pressure die cast aluminium base and a protector made of LDPE (Low Density Polyethylene) having separate IP66 optical & control gear compartments, impact resistance of IK10, suitable for surface mounting. Excellent photometry to maximise the spacing between the bollards. Suitable for on-ground mounting on 3xM10 bolts on 230mm PCD. System power of 15W, correlated colour temperature (CCT) of 4000K (optional 3000K & 5700K), colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV.
Supply of MCB box with open able door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) - Outdoor / Polystyrene (PS) - Indoor should have Degree of Ingress Protection IP 65 in accordance with IEC 60529. The Junction Box shall have hinged door/cover. The Junction Box shall have pre punched / knock out for cable entry in all the four sides as well as on the back side. Drilling holes at the work site is not permitted. The Junction box shall be suitable to perform under ambient temperature for PS -25 degC up to +40 degC & PC -35 degC up to +80 degC & should be able to resist temperature up to +130 degC. The JB shall be halogen & silicon free. The PC thermoplastic JB shall be fire retardant & self-extinguishing, the combustion behavior shall be in accordance with VDE 0471 / UL 94 for 960degC. The Junction Box shall be UV resistance. The enclosures shall have the minimum dimensions as below. Outdoor Glass Fiber Reinforced Polycarbonate (PC) 250 x 370 x 122 Min 24 module
Installation, Testing and commissioning of MCB box with open able door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) - Outdoor / Polystyrene (PS) - Indoor should have Degree of Ingress Protection IP 65 in accordance with IEC 60529. The Junction Box shall have hinged door/cover. The Junction Box shall have pre punched / knock out for cable entry in all the four sides as well as on the back side. Drilling holes at the work site is not permitted. The Junction box shall be suitable to perform under ambient temperature for PS -25 degC up to +40 degC & PC -35 degC up to +80 degC & should be able to resist temperature up to +130 degC. The JB shall be halogen & silicon free. The PC thermoplastic JB shall be fire retardant & self-extinguishing, the combustion behavior shall be in accordance with VDE 0471 / UL 94 for 960degC. The Junction Box shall be UV resistance. The enclosures shall have the minimum dimensions as below. Outdoor Glass Fiber Reinforced Polycarbonate (PC) 250 x 370 x 122 Min 24 module
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A 100mA 4P RCBO (Feeder pillar Incomer)
Installation, Testing and commissioning of following rating, four pole, (three phase and neutral), 415 V, residual current operated circuit breaker with overcurrent protection (RCBO),having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A 100mA 4P RCBO (Feeder pillar Incomer)
SUB HEAD XV - SAFETY AND TESTING EQUIPMENTS
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) of size 60 cm X 60 cm at the bottom and 50cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. each 530
Supply and installation of 9 liter capacity fire bucket made of galvanized mild steel, painted with fire red color (post office red) with "FIRE" written in white letters on bucket body, complete with wall mounting 'MS' stand having arrangement for 4 buckets holding with sand filling as per standard norms, as required.
Supply and installation of standard first aid box made of steel sheet with powder coated finish, wall mounting type, having lockable front cover,as required.
Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi & English).
One Tool kit comprising 1 set of flat spanner (Taparia / Stanley/Jalan ), 1 set of box spanner, 1 no. Hacksaw frame with 10 no. blades, 1 no. large, medium, small screw drivers, 1 no. insulated plier, 1 no. nose plier, 1 no. hand crimping tool upto 16 sq.mm, 1 no. digital multimeter, 1 no. test lamp and 1 no. tester, Screw driver set for all types of screw heads also to be provided,
PVC Mat Supply and providing ISI grade rubber mat (Synthetic) as per inspectorate standard., 1M x 2.5mm thick, suitable for 1.1 KV , fire retardant,no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity conforming to IS: 15683-2006 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2.5mm thick, suitable for 11 KV , fire retardant,no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
SUB HEAD XVI - EXTERNAL LIGHTNING PROTECTION SYSTEM
Supply, installation, testing and commissioning of 8 mm Aluminum Round Conductor as horizontal air terminal with the required mounting clamps , cross connectors, T connectors ,glue, expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on Terrace/Parappet/Tile.
Supply, installation, testing and commissioning of 8 mm Aluminum Round Conductor as vertical down conductor with the required mounting clamp and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on surface as needed.
Supply, installation, testing and commissioning of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561.
Supply of stand for fang fix system 16 Kg with base and clamp made up of frost resistant concrete and tested up to 100 KA lightning current
Installation, testing and commissioning of stand for fang fix system 16 Kg with base and clamp made up of frost resistant concrete and tested up to 100 KA lightning current .
Supply, installation, testing and commissioning of Test Joint with box, suitable to fix 8 mm Aluminium conductor to 30 X 3 GI strip
Supply, installation, testing and commissioning G.l. tape 30 mm X 3 mm from earth. electrode directly in ground as required with the required cross connectors ,spacer clip, Plastic Corrosion Protection strip
Supply, installation, testing and commissioning of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing Heavy duty FRP earth champer of 5000kg load bearing capacity to ensure the safety of earthing system .
Annual Maintenance Contract Annual maintenance contract for the 320KVA (minimum) capacity DG including replacement of parts/components(as per OEM recommendation), breakdown maintenance, periodical servicing for 5 years after the 2yrDLP period. For the services to be rendered during the AMC period refer Additional Special Conditions of Contract
1st Year
2nd Year
3rd Year
4th Year
5th Year
NATIONAL ELECTRIC COMPANY (BID ID -2199929)
THANNICKAL BROTHERS (BID ID -2185757)
Leela Electricpower Services Pvt.Ltd (BID ID -2189694)
Biju E.M (BID ID -2200125)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tenderdocument.pdf
Tender Documents • 1.91 MB
Tenderdocument.rar
Tender Documents • 16.96 MB
BOQ.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .