Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L1 | Accepted-AOC Being L1 and contract awarded | |
| 2 | L2₹3.6 L+₹42 (0.01%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹3.6 L+₹2,860 (0.80%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
18 Oct 2024, 6:00 pmClosed
AGE (I) R and D Haldwani
AGE (I) R and D Haldwani PO Arjunpur UK 263139
REPAIR / MAINTENANCE OF DG SETS, SECURITY LIGHT, STREET LIGHT AND OTHER MISC E/M WORKS AT DIBER FD STATION PITHORAGARH
2024_MES_675867_1
AGE(I)/RandD/HLD-35 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
DIBER FD STN PITHORAGARH
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) R and D Haldwani
₹8,000
Yes
28 Oct 2024
21 Sept 2024
21 Oct 2024
21 Sept 2024
18 Oct 2024
5 Oct 2024
Amount
Contract Details
Supply, fixing and testing LT cable jointing kit straight through heat shrinkable type suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5/4 core 16 to 50 sqmm complete all as directed.
Dismantling / taking down in repairs the street light / security lights of any capacity & description from existing LT pole/walls at any height and refixing the fittings in existing / another location after repair work all as directed by Engg-in-charge. Note:- (i) Replacement of defective parts / accessories shall be measured and paid separately under relevant items. (ii) Transport and T & P i.e. Ladder, safety items, or any other equipment for repair of street light shall be provided by Contractor and cost for the same deemed to be incl in respective items.
S&F in repair service wire 1100 volts grade PVC insulated PVC unsheathed cable multi stranded copper conductor of size 3 core 1.0 sqmm complete all as specified.
S&F in repair service wire 1100 volts grade PVC insulated PVC sheathed cable weather proof multi stranded with aluminum conductor of size 6.0 sqmm 2 core complete all as specified.
S&F in repair service wire 1100 volts grade PVC insulated PVC sheathed cable weather proof multi stranded with aluminum conductor of size 10 sqmm 2 corecomplete all as specified.
Material & Labour for fixing LED flood light luminaries of cap 120 watt, 230 volt AC,outdoor type with high Pressure die cast Aluminium housing and heat resistant complete with with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, IP 67 protection complete with accessories, pre wired up to a terminal block and mounting attachment complete all as specified. Make :-SYSKA CAT PART No SSK-BLS-CF-120WAT or equivalent Bajaj/Crompton/Havells etc.
M&L in repair existing post top lantern of any type and watage with replacement of new integral LED post top lantern for 20 watt LED luminaries IP65 aluminium encloser all as specified and directed.
Supply and fixing in repair integral LED street light luminaries comprising of epoxy powder coated housing, enclosed with glass cover in frame of capacity 70/72 watt, Ingress protection IP 65 protection including connected wire, Suitable for 40mm dia pipe, with complete accessories to be fixed on pole/wall including connecting the fitting to over head ACSR/bus bar box at the bottom of pole with using 1.00 Sqmm three core PVC insulated and unsheathed copper conductor cable complete all as specified and directed.
Supply and fix light fitting batten type complete with accessories inverter LED batten with opal diffuser, IP20, battery backup prewired and connection complete with cat part No LED INVERTER BATTEN HLB-08-10-CW-INV of capacity 10watt of make Halonix or equivalent complete all as specified and directed.
Supply and fix inverter LED bulb in B-22 cap and with opal diffuser IP20, battery back up and functioning complete all specified and directed Code No LED INVERTER LIGHT 10W B22 CW IP of 10 watt of make Halonix or equivalent complete all as specified and directed.
S&F in repair LED driver 72W/120W 2600mA suitable for LED light fitting completed all as specified and directed.
Trimming of tree branches touching to over head lines, up to 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearance of HT/LT pole and sub station premises all as directed Note: (i) Trimming of all branches of trees falling under one span between two pole shall be considered as one span only. (ii) Contractor have to arrange all T&P, safety equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishappening occurred due to negligence of safety aspects.
Dismantling and opening of air cooled DG set of 10 KVA 415 v 1500 RPM 50 HZ capacity including coupled alternator with the engine unit for repair, Maintenance and servicing mechanically and electrically, incl cleaning, oiling/greasing, removing & replacement of defective unserviceable parts with new parts, ie ‘O’ rings/diesel filter /oil filter /Air filter /fan belt / hose/ Engine Oil etc as required at site and manufacturer's instructions and checking of valves & nozzles etc, reassembling the DG set ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site on full load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed.Notes:- (i) The quoted rates of the contractor includes replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. The new replaced parts shall be measured and paid for separately under appropriate item of Sch 'A’ (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge (iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Supply only” and shall be measured and paid separately under appropriate item of Sch ‘A’. Its cost of filling is deemed to be included under the rates quoted by the contractor for above item.
All as per item No 14 above but 30 KVA.
All as per item No 14 above but 35 KVA.
Supply and fix Fuel filter primary/secondary element complete with sealing ring and copper washer suitable for 10 KVA to 35KVA DG set complete all as directed.
Supply and fix lubricating oil filter complete with seal ring suitable for 10 KVA to 35KVA DG set complete all as directed.
Supply and fix fuel pipe from feed pump to fuel filter suitable for 10 KVA to 35KVA DG set complete all as directed.
Supply and fix fuel pipe from fuel filter to fuel pump suitable for 10 KVA to 35KVA DG set complete all as directed.
Supply and fix Gasket for cylinder head suitable for 10 KVA to 35KVA DG set complete all as directed.
Supply and fix V belt suitable for 10 KVA to 35KVA DG set complete all as directed.
Supply and fll Engine oil castrol 15 W- 40 grade complete all as directed.
M&L for cleaning outer body of DG set incl oil tank of DG sets of various capacity by collecting the fuel in cleaned barrels and removing sludge deposited/ accumulated inside the tank including replacement of fuel tank locking arrangement and fuel hose pipe with new and one coat painting outer body of DG set and fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
M&L for checking the serviceableaty of the electric wiring system the components/ parts of alternator repair and replacement of brushes, diods, self exiter and battery terminals, terminal clamps incl varnishing of alternator winding, etc, re-assembling the parts and making the component serviceable and its testing on installation complete all as specified and directed.
S&F automatic battery charger 12 volt auto cut reverse protection of output voltage 12 volt with copper winding complete all as specified and directed.
Supply & fixing battery 150 AH 12 Volt of complete all as specified and directed. Make EXIDE GOLD /AMARON/ LUMINIOUS.
Supply & fixing battery 80 AH 12 Volt of complete all as specified and directed. Make EXIDE GOLD /AMARON/ LUMINIOUS. .
Material and labour for repair/replacement of burnt winding of Dynoma/ alternator of 10-35 KVA DG Set opening it from DG Set taking it to the workshop for repair, after repairing fixing it to the proper place in DG set and testing it after running the DG set weather the alternator is charging battery properly, complete all as specified and as directed by Engr-in-Charge.
Servicing and calibration of FIP (Fuel injection pump) & nozzles incl replacement of minor parts like nuts, bolts, washers etc for DG set of capacity 10 to 30 KVA.
S&F in replacement Solenoid Switch for 10 KVA to 30 KVA DG set and testing complete for proper functioning.
S&F in replacement of Ignition Switch of DG Sets & complete all as directed.
S&F in replacement of AVR suitable for 10 KVA to 35 KVA DG Sets complete all as directed.
S&F Self Starter suitable for 10 to 35 KVA DG Set 12 Volt Make: Lucas/AutoLak.
Supply and install, testing off load type changeover switch four pole, AC 415 volts 50 HZ of capacity 63 Amps 4 pole with enclosure, side handle operated conforming to IS:13947 incl fixing on wall/panel complete all as directed.
Note :-Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/s Dhapola Elevator and Engineering (BID ID -3136438)
shivam builders (BID ID -3143332)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .