Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹17.8 L
EMD Value
₹44,439
Closing Date
15 Oct 2026, 3:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Office of the Executive Engineer, PWD Buildings Di
The Executive Engineer, PWD Buildings Division, Kozhikode
GENERAL Leak rectification and maintenance of various wards at IMCH Govt Medical College Kozhikode Maintenance work General Civil Work
2026_PWD_877961_1
22/EEBK/2026-27
Open Tender
Civil Works - Buildings
Item Rate
240 days
Medical College
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹44,439
Yes
9 Oct 2026
9 Oct 2026
17 Oct 2026
9 Oct 2026
15 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Maintenance work | |||||
| 1.001 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 32.55 | sqm | - | - |
| 1.002 | 5.46.1:Providing and fixing of expansion joint system of approved make and manufactures
for various roof locations as per approved drawings and direction of Engineer-In-
Charge. The joints shall be of extruded aluminum base members with, self aligning
and self centering arragement support plates asper ASTM B221-02. The system
shall be such that it provides watertight roof to roof/roof to corner joint cover
expansion control system that is capable of accommodating multidirectional
seismic movement without stress to its components. System shall consist of metal
profile that incorporates a universal aluminum base member designed to
accommodate various project conditions and roof treatments. The cover plate shall
be designed of width and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing manufacturer’s preengineered
self-centering arrangement that freely rotates / moves in all directions.
The Self centering arrangement shall exhibit circular sphere ends that lock and
slide inside the corresponding aluminum extrusion cavity to allow freedom of
movement and flexure in all directions including vertical displacement. The Joint
System shall resists damage or deterioration from the impact of falling ice, exposure
to UV, airborne contaminants and occasional foot traffic from maintenance
personnel. Provision of Moisture Barrier Membrane in the Joint System to have
water tight joint is mandatory requirement. Material shall confirm to ASTM 6063.Roof Joint of 100 mm gap. | 30 | metre | - | - |
| 1.003 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. | 32.55 | sqm | - | - |
| 1.004 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | 380 | sqm | - | - |
| 1.005 | 50.12.2.1:Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. | 216 | sqm | - | - |
| 1.006 | 14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done . | 435 | sqm | - | - |
| 1.007 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources) | 18.75 | cum | - | - |
| 1.008 | 50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall | 35 | metre | - | - |
| 1.009 | 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow | 10 | no | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
SBD.pdf
Tender Documents • 1.64 MB
BOQ_1492108.xls
BOQ • 0.32 MB
OfficeMemorandum.pdf
Other Document • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .