Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹47,652
Closing Date
21 Aug 2023, 3:00 pmClosed
EXECUTIVE ENGINEER
H W DIVISION,ARUVIKKARA
JJM CWSS TO VEMBAYAM PROVIDING INTERCONNECTION FROM EXISTING 140MM PVC PIPE AT VEDARUKONAM TO 140 MM PVC PIPE AT SHAUL HAMEED ROAD THROUGH PAZHAKUTTY MANGALAPURAM ROAD PROVIDING INTERCONNECTION AT KONCHIRA JUNCTION INORDER TO IMPROVE WATER SUPPLY
2023_KWA_592831_1
30/2023-24/HWD/JJM
Open Tender
Civil Works - Others
Item Rate
180 days
WORKS
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
Yes
₹47,652
Yes
27 Oct 2023
4 Aug 2023
22 Aug 2023
4 Aug 2023
21 Aug 2023
4 Aug 2023
Amount
Supply of pipes
100.98.238:Supply PVC Pipe, 10kg/cm2, 140mm Dia.
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
100.98.483:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 125mm.
Working charges
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.31.1.3:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 125mm diameter, Class I.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
OD101374/2023-2024:Providing and fixing 125mm GI pipes complete with GI fittings including trenching and refilling etc complete.For external work
OD101412/2023-2024:Taking connection from 160/140/110 /90 to /75/63/50/40/32 mm or nearest size. PVC/GI distribution main to branch line using suitable equal Tee(suitable class),reducer, CID/CIR and reducers including cost of materials labor charge etc complete.
OD101483/2023-2024:Construction of valve chamber of size 0.9x0.9x1.00 inside including conveying supplying and fixing CI manhole cover of dia 560 mm
Booster Pumps
OD108410/2023-2024:Supply, Instalation of variable head booster pump,3 phase,50 Hz. The rate includs,cost of pump,cost of motor,cost of panel board,cost of starter,Aluminium cable from panel board to starter and starter to Motor,cost of Capacitor, suction pipe 10 m length, foot valve,Non return and sluice valve,pipe connection works for suction side and delivery side , suitable Earthing as per IE rule,Errection charges including foundation , base plate, cost of cement sand and metal, trail run and commissioning etc. complete as per the direction of Engineer incharge.
OD108411/2023-2024:Supply, Instalation of variable head booster pump,3 phase,50 Hz. The rate includs,cost of pump,cost of motor,cost of panel board,cost of starter,Aluminium cable from panel board to starter and starter to Motor,cost of Capacitor, suction pipe 10 m length, foot valve,Non return and sluice valve,pipe connection works for suction side and delivery side , suitable Earthing as per IE rule,Errection charges including foundation , base plate, cost of cement sand and metal, trail run and commissioning etc. complete as per the direction of Engineer in charge
OD108412/2023-2024:OYEC amount for taking connection to the Booster pump house including CD, Inspcetion charges etc. complete.
OD108413/2023-2024::Protection cover for Booster pump, KYOSK for placing the energy meter starter and pannel board accessories.
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.17.6:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
OD108414/2023-2024:Construction of valve chamber of size 0.9x0.9x1.00 inside including conveying supplying and fixing CI manhole cover of dia 560 mm
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
OD108655/2023-2024:Taking connection from 160/140/110 /90 to 160/140/110 /9075/63/50/40/32 mm or nearest size. PVC/GI distribution main to branch line using suitable equal Tee(suitable class),reducer, CID/CIR and reducers including cost of materials labor charge etc complete.
Konchira interconnection
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.12.8:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 80mm diameter nominal bore.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
100.52.S.1:Sub Data for providing Earth filled cement bags including cutting of the Earth, filling, conveying and placing in position.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
100.98.481:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 80mm.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
OD108757/2023-2024:Worker engaged for traffic control, bailing out of water from trenches assisting fitter
OD108760/2023-2024:Taking connection from 160/140/110 /90 to 90/75/63/50/40/32 mm or nearest size. PVC/GI distribution main to branch line using suitable equal Tee(suitable class),reducer, CID/CIR and reducers including cost of materials labor charge etc complete.
Manoj S
Bidder Name
Manoj S
NOUSHAD S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_878344.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .