CM MES
CM MES CONTRACT CELL RCF LTD. TROMBAY
Transformers Oil Leakage and its associated jobs in NAG and Ammonia V Plant at RCF Ltd. Chembur Mumbai
2021_RCFL_660905_1
ET-CC/Transformer Repair/2122-51
Open Tender
Miscellaneous Services
Works
365 days
RCFLtd. Chembur
As per Tender
11 documents required · 11 mandatory
₹0
Exempted
9 Apr 2022
2 Dec 2021
16 Dec 2021
2 Dec 2021
16 Dec 2021
2 Dec 2021
Amount
Complete oil replacement of transformer-1 at site as per the Part-A of Scope of Work
Oil leakage job of transformer-1 & 2 at site as per the Part-B of Scope of Work
Painting of transformer-1 at site as per the Part-C of Scope of Work
H.V. (11kV) Porcelain Insulator (if reqd.)
H.V. (11kV) metal studs (if reqd.)
H.V. (11kV) Palm connector (if reqd.)
L.V. (415 V) Porcelain Insulator ( if reqd)
L.V. (415 V) metal studs ( if reqd)
L.V. (415 V) Palm connector ( if reqd)
Buchholz relay ( if reqd)
Explosion vent diaphragm ( if reqd)
WTI ( if reqd)
OTI ( if reqd)
Flexible Jumper ( if reqd)
Conservator oil level glass indicator ( if reqd)
Marshalling box glass ( if reqd)
Drain Valve ( if reqd)
Silica Gel Breather
Oil leakage job of 11/3.3kV, 9 MVA transformer at site as per the Scope of Work
Oil leakage job of 11/0.415 kV, 2 MVA transformer at site as per the Scope of Work
Oil leakage job of 11/0.440 kV, 1.25 MVA transformer at site as per the Scope of Work
H.V. (11kV) Porcelain Insulator (if reqd)
H.V. (11kV) metal parts ( if reqd)
H.V. (11kV) Palm connector ( if reqd)
H.V. (3.6kV) Porcelain Insulator ( if reqd)
H.V. (3.6kV) metal parts ( if reqd)
H.V. (3.6kV) Palm connector ( if reqd)
L.V. (415 V) Porcelain Insulator ( if reqd)
L.V. (415 V) metal parts ( if reqd)
L.V. (415 V) Palm connector (if reqd)
Buchholz relay (if reqd)
Explosion vent diaphragm
WTI ( if reqd)
OTI ( if reqd)
Rubber seal for LV insulator
Flexible Jumper (if reqd)
Conservator oil level glass indicator (if reqd)
Marshalling box glass (if reqd)
Rubberized cork sheet (3 ft X 3 ft, 6mm thick or 3 ft X 2 ft, 10mm thick)
Drain Valve (if reqd)
Nickel coated MS Connection bolts of requires size. (if reqd)
industrial filtration
Trans Electro
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .